Zenitel TEIV+ User manual

1
EN
A100K12201
v1.5
TEIV+
Mounting & Installation Manual
Turbine Extended IP Video Station

2 3
This document serves as a mounting and installation guide
for the TEIV+ Turbine Extended IP Video Stations.
For more information and instructions on configuration of the
TEIV-1+ and TEIV-4+ go to: wiki.zenitel.com/wiki/Main_Page.
The TEIV+ series consists of the following components:
About
Item Number Item Name Description
1008317110 TEIV-1+ Turbine Extended IP Video
Intercom with Keypad and Display
1008318240 TEIV-4+ Turbine Extended IP Video with
RFID Card Reader Space
1008140330 TA-33 Turbine Extended On-wall Backbox
1008140340 TA-34 Turbine Extended Flushmount
Backbox
Safety information
This manual contains important instructions that must be followed.
These instructions are intended to ensure that the product is
mounted and installed correctly to avoid equipment damage or
property loss.
A note symbol indicates that extra care must be taken.
Damage to equipment can occur, or it may not function as
intended. Please read all warnings before installing this
product.
The station should be installed by a competent person in
accordance with national and local regulations. Zenitel takes no
responsibility for damages caused by improper or inadequate
installation.
Description
TEIV-1+
123
456
7 8 9
0
Item Description
1Camera
2Speaker
3LCD
4Standard Keypad
5Navigation Keys
6Confirmation/Call Key
7Cancel Key
8Microphone
3
4
1
2
5
6
7
8
Item Description
1Camera
2Speaker
3Call Key
4Card Reader
5Microphone
3
4
1
2
5
TEIV-4+

4 5
COM
NO
NC
+5V
1
2
3
4
5
6
I/O
+
_
+
_
+
_
24VDC
+-
COM
NO
NC
+5V
1
2
3
4
5
6
I/O
+
_
+
_
+
_
24VDC
+-
1
2
3
4
5
6
7
8
9
10
11
12
Item Description Comment
1CPU Module
2Card Reader Slot Only in use for TEIV-4+
3Card Reader Bracket
4Relay
Double Throw relay contact with 60W
switching power. COM, NO, NC contacts are
provided. Max: 250VAC/220VDC, 2A, 60W.
5I/O interface
6 general purpose I/Os.. Each I/O can be
configured as either input, output, or LED
driver.
6Line Output A balanced 600 ohm audio line out with
induction loop signal.
7Speaker Input Connect an external speaker rated for 8 Ohm
8Microphone input Electret mic input
9Power Input Optional 24VDC power input from external
power supply
10 LAN Port 10/100/1000Mbps RJ-45 port connecting to
Ethernet. PoE/PoE+ is supported.
11 SD-card Slot
12 USB-C Port Used during production process and for
recovery
Installation
TEIV-1+/TEIV-4+ can be powered by PoE. This is done by connecting an Ethernet cable to the LAN port of the station and a PoE switch.
NB! If PoE is used, the station must be installed using a shielded Ethernet cable with grounding at the switch end.
The included Snap On Ferrite (EMKOB99123.0100) must be attached to the Ethernet cable near the LAN port inside the backbox.
If the switch does not support PoE, a 24VDC power supply can be connected to the stations Power Input.
Mounting
Mounting considerations
Ensure there is enough clearance under the station so
that the microphone aperture is NOT smothered.
To achieve an optimal field of view, the station should be
mounted so that the lens is placed at a height of approx.
120 cm.
145°
50 cm
190 cm
50 cm
120 cm
109°
Vertical Angle Horizontal Angle
50 cm
320 cm

6 7
Mounting card readers
The TEIV-4+ has a card reader slot, fitting either HID Signo 20 ReaderTerminal Strip or TWN4 Palon Compact LEGIC PCB. Do the following
when mounting the card readers.
HID Signo 20 ReaderTerminal Strip
12
Unscrew the Card Reader Bracket. Make sure the
Self-Clinching Standos are facing outwards.
Remove the back lid from the card reader, and
fasten the lid to the Card Reader Bracket. Then
reattach the card reader to the lid.
Fasten the Card Reader bracket to the TEIV-4+.
Make sure to use the U-notches on the bracket
when fastening.
Connect the card reader to the local door controller
as part of the access system.
1
2
3
TWN4 Palon Compact LEGIC PCB
Unscrew the Card Reader Bracket. Make sure the
Self-Clinching Standos are facing inwards.
Separate the two parts of the card reader and
attach the part with screw holes to the Card Reader
Bracket. Then reassemble the card reader.
Fasten the Card Reader bracket to the TEIV-4+.
Make sure to use the U-notches on the bracket
when fastening.
Connect the card reader to the local door controller
as part of the access system.
1
2
3
1
2
3
44
4
4
3

8 9
Insert the TA-34 Backbox into designated slot in the wall.
Fasten the back box to the wall.
Plug the Ethernet cable into LAN port on the station. If the
switch does not support PoE, a 24VDC Power Supply can be
connected to the stations Power Input.
Mount the Turbine Extended Station onto the Backbox
with the M5 fasteners provided. Apply 1.5 Nm torque.
2
3
1
2
3
4
4
1
34 23 177 23
90
6
4,5
80
Ø 20
Flush mounting
For flush mounting the Turbine Extended, use the TA-34
Turbine Extended Flushmount Backbox.
60
120
308

10 11
Mount the TA-33 Backbox onto the wall using A4 socket
head screws
Plug the Ethernet cable into LAN port on the station. If the switch
does not support PoE, a 24VDC Power Supply can be connected
to the stations Power Input.
Mount the Turbine station onto the back box with the M5
fasteners provided. Apply 5 Nm torque.
1
2
3
1
2
3
To ensure the IP-66 rating, use the grommets and M20
cable gland provided for the cable holes on the back
box.
On-wall mounting
For mounting the Turbine Extenden on the
wall, use the TA-33 Turbine Extended On-
wall Backbox.
• Mounting holes are to be drilled as
shown in the figure.
• Max. recommended screw diameter:
ISO M6 or ANSI 1/4”.
• Screw length must be greater than 25
mm or 1”.
• A4 stainless steel socket head
screws/bolts are recommended. Max.
screw head diameter: 9.5 mm or 3/8”.
76
275
Ø 20
61
120
305
25
Ø 6,5
Ø 9,5

12 13
Get started
When the Turbine Extended Station is connected to the
network, its IP address is automatically obtained from a DHCP
server or an IP adress in the range 169.254.xx will be assigned.
To make the station speak its IP address, press the Call Key on
the station.
The Turbine Extended can operate in two dierent modes,
Edge and SIP, depending on what kind of server it is registered
to. Enter the link or scan the QR-code below to go to Zenitel
Wiki for configuration instructions.
Zenitel Wiki: wiki.zenitel.com/wiki/Main_Page.
Technical specifications Value
Weight TEIV-1+: 1.08kg
TEIV-4+: 1.05kg
Dimensions (HxWxD) 305 x 120 x 72,5mm
IP Rating IP 66
IK Rating IK08
Relative humidity < 95% not condensing
Operating temperature range -40° to 70° C / -40° to 158 ° F
Encapsulation material Aluminium
Power Options PoE, PoE+, 24VDC PSU
PoE (power over Ethernet) IEEE 802.3af standard, IEEE 802.3at
Power consumption Idle 3.5W, max 12W (depending on
volume)
Contact Information
Visit zenitel.com to find your country’s contact information.
Specifications

14
The WEEE Directive does not legislate that Zenitel, as a ‘producer’,
shall collect ‘end of life’ WEEE.
This ‘end of life’ WEEE should be recycled appropriately by the owner
who should use proper treatment and recycling measures. It should
not be disposed to landfill.
Many electrical items that we throw away can be repaired
or recycled. Recycling items helps to save our natural finite
resources and also reduces the environmental and health risks
associated with sending electrical goods to landfill.
Under the WEEE Regulations, all new electrical goods should
now be marked with the crossed-out wheeled bin symbol
shown.
Goods are marked with this symbol to show that they were
produced after 13th August 2005, and should be disposed of
separately from normal household waste so that they can be
recycled.

DOC. NO.
Zenitel and its subsidiaries assume no responsibility for any errors that may appear in this publication, or for damages arising from the information therein. Zenitel, Vingtor-Stentofon and Phontech products are developed
and marketed by Zenitel. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001. Zenitel reserves the right to modify designs and alter specifications without notice. ZENITEL
PROPRIETARY. This document and its supplementing elements contain Zenitel or third-party information which is proprietary and confidential. Any disclosure, copying, distribution or use is prohibited, if not otherwise explicitly
agreed in writing with Zenitel. Any authorized reproduction, in part or in whole, must include this legend: Zenitel – All rights reserved.
sales@zenitel.com
A100K12201v1.5
This manual suits for next models
2
Table of contents
Other Zenitel Intercom System manuals

Zenitel
Zenitel VR3G-1 Guide

Zenitel
Zenitel TCIS-1 Guide

Zenitel
Zenitel VINGTOR STENTOFON ECP-AA1 Quick guide

Zenitel
Zenitel EAPFX-1-V2 Instruction Manual

Zenitel
Zenitel Phontech CIS 3100 Instruction Manual

Zenitel
Zenitel Vingtor Stentofon ITSV-3 User manual

Zenitel
Zenitel ITSV-2 User manual

Zenitel
Zenitel IPDM-V2_P User manual

Zenitel
Zenitel Turbine Compact IP + Guide

Zenitel
Zenitel VINGTOR STENTOFON ITSV-1 User manual