4 5
COM
NO
NC
+5V
1
2
3
4
5
6
I/O
+
_
+
_
+
_
24VDC
+-
COM
NO
NC
+5V
1
2
3
4
5
6
I/O
+
_
+
_
+
_
24VDC
+-
1
2
3
4
5
6
7
8
9
10
11
12
Item Description Comment
1CPU Module
2Card Reader Slot Only in use for TEIV-4+
3Card Reader Bracket
4Relay
Double Throw relay contact with 60W
switching power. COM, NO, NC contacts are
provided. Max: 250VAC/220VDC, 2A, 60W.
5I/O interface
6 general purpose I/Os.. Each I/O can be
configured as either input, output, or LED
driver.
6Line Output A balanced 600 ohm audio line out with
induction loop signal.
7Speaker Input Connect an external speaker rated for 8 Ohm
8Microphone input Electret mic input
9Power Input Optional 24VDC power input from external
power supply
10 LAN Port 10/100/1000Mbps RJ-45 port connecting to
Ethernet. PoE/PoE+ is supported.
11 SD-card Slot
12 USB-C Port Used during production process and for
recovery
Installation
TEIV-1+/TEIV-4+ can be powered by PoE. This is done by connecting an Ethernet cable to the LAN port of the station and a PoE switch.
NB! If PoE is used, the station must be installed using a shielded Ethernet cable with grounding at the switch end.
The included Snap On Ferrite (EMKOB99123.0100) must be attached to the Ethernet cable near the LAN port inside the backbox.
If the switch does not support PoE, a 24VDC power supply can be connected to the stations Power Input.
Mounting
Mounting considerations
Ensure there is enough clearance under the station so
that the microphone aperture is NOT smothered.
To achieve an optimal field of view, the station should be
mounted so that the lens is placed at a height of approx.
120 cm.
145°
50 cm
190 cm
50 cm
120 cm
109°
Vertical Angle Horizontal Angle
50 cm
320 cm