EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Zephyr
  6. •
  7. Ventilation Hood
  8. •
  9. Zephyr Siena ZSI-E30AS Installation guide

Zephyr Siena ZSI-E30AS Installation guide

Other manuals for Siena ZSI-E30AS

1

This manual suits for next models

3

Other Zephyr Ventilation Hood manuals

Zephyr Luce ZLU-E30BS Installation guide

Zephyr

Zephyr Luce ZLU-E30BS Installation guide

Zephyr EAL-E42ASX User manual

Zephyr

Zephyr EAL-E42ASX User manual

Zephyr elica Optica EOP-E42ASX Installation guide

Zephyr

Zephyr elica Optica EOP-E42ASX Installation guide

Zephyr Okeanito COK-E36BSX Installation guide

Zephyr

Zephyr Okeanito COK-E36BSX Installation guide

Zephyr AK9134B Installation guide

Zephyr

Zephyr AK9134B Installation guide

Zephyr ZML-M90BG Installation guide

Zephyr

Zephyr ZML-M90BG Installation guide

Zephyr ZVE-E30DS Installation guide

Zephyr

Zephyr ZVE-E30DS Installation guide

Zephyr Venezia ZVE-E30BS Installation guide

Zephyr

Zephyr Venezia ZVE-E30BS Installation guide

Zephyr AK8000CS Installation guide

Zephyr

Zephyr AK8000CS Installation guide

Zephyr AK7036BS Installation guide

Zephyr

Zephyr AK7036BS Installation guide

Zephyr Pisa ZPI-E24AG290 Installation guide

Zephyr

Zephyr Pisa ZPI-E24AG290 Installation guide

Zephyr LAYERS WALL DLA-E42ASSX User manual

Zephyr

Zephyr LAYERS WALL DLA-E42ASSX User manual

Zephyr AK9358BS Installation guide

Zephyr

Zephyr AK9358BS Installation guide

Zephyr Lux ALU-E43CSX Installation guide

Zephyr

Zephyr Lux ALU-E43CSX Installation guide

Zephyr Tempest AK0714 Installation guide

Zephyr

Zephyr Tempest AK0714 Installation guide

Zephyr AK7000AS Installation guide

Zephyr

Zephyr AK7000AS Installation guide

Zephyr Siena ZSI-E30CS User manual

Zephyr

Zephyr Siena ZSI-E30CS User manual

Zephyr Monsoon I Installation guide

Zephyr

Zephyr Monsoon I Installation guide

Zephyr AK7000 Installation guide

Zephyr

Zephyr AK7000 Installation guide

Zephyr AK6500 series Use Installation guide

Zephyr

Zephyr AK6500 series Use Installation guide

Zephyr Siena ZSI-E30AS Installation guide

Zephyr

Zephyr Siena ZSI-E30AS Installation guide

Zephyr AK9234AS Installation guide

Zephyr

Zephyr AK9234AS Installation guide

Zephyr ARC AHZ-M90ABX User manual

Zephyr

Zephyr ARC AHZ-M90ABX User manual

Zephyr Tempest II AK7500CS Installation guide

Zephyr

Zephyr Tempest II AK7500CS Installation guide

Popular Ventilation Hood manuals by other brands

Haier CXW-219-D67 null

Haier

Haier CXW-219-D67 null

emmeti RECUPA MED A-140 Installation and use manual

emmeti

emmeti RECUPA MED A-140 Installation and use manual

Nibe F135 user manual

Nibe

Nibe F135 user manual

Kuppersberg INTRO 60 Technical Passport

Kuppersberg

Kuppersberg INTRO 60 Technical Passport

Hisense MH6INBG manual

Hisense

Hisense MH6INBG manual

Miele DA 1255 Operating and installation instructions

Miele

Miele DA 1255 Operating and installation instructions

Broan 46000 Specification sheet

Broan

Broan 46000 Specification sheet

GE Profile PV977 Owner's Manual & Installation Instructions

GE

GE Profile PV977 Owner's Manual & Installation Instructions

FALMEC FFRIA24W5FS Instruction booklet

FALMEC

FALMEC FFRIA24W5FS Instruction booklet

Whirlpool RH2600XL-1 SERIES installation instructions

Whirlpool

Whirlpool RH2600XL-1 SERIES installation instructions

ETNA AV360RVS Instructions for use

ETNA

ETNA AV360RVS Instructions for use

JUNO JDF603E6 installation manual

JUNO

JUNO JDF603E6 installation manual

Miele DA 6708 D Operating and installation instructions

Miele

Miele DA 6708 D Operating and installation instructions

Tricity Bendix LE 150 Installation & operating instructions

Tricity Bendix

Tricity Bendix LE 150 Installation & operating instructions

AEG X68163BV1 user manual

AEG

AEG X68163BV1 user manual

AEG 125 D operating instructions

AEG

AEG 125 D operating instructions

Smeg KSEV97X instruction manual

Smeg

Smeg KSEV97X instruction manual

Nibe S Series Installer manual

Nibe

Nibe S Series Installer manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
SEP15.0301 © 2015 Zephyr Ventilation LLC.
Siena
ZSI-E30AS
ZSI-E36AS
ZSI-E30AS-ES
ZSI-E36AS-ES
ZSI-E30AS-ES
ZSI-E36AS-ES
5
Duct pieces To t a l
Equivalent number
length x used =
3-1/4” x 10”
Rect.,
straight
1 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.to
6” round
transition
5 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.to
6” round
transition
900 elbow
20 Ft. x ( ) = Ft.
6”, 7”, 8”, 10”
Round,
900
15 Ft.
x ( ) = Ft.
6”, 7”, 8”, 10”
Round,
450
9 Ft. x ( ) = Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) = Ft.
Subtotal column1 =
Duct pieces To t a l
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) = Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) = Ft.
Subtotal column2 =
Subtotal column1 =
Total ductwork =
MaximumDuct Length:For satisfactory air movement,
the total duct length
should not exceed 100 equivalent feet.
6” roundto
3-1/4” x 10”
rect.
transition
1 Ft. x ( ) = Ft.
6” roundto
3-1/4” x 10”
rect.
transition
900 elbow
16 Ft. x ( ) = Ft.
7” roundto
3 1/4” x 10”
rect.
transition
8 Ft. x ( ) = Ft.
7” roundto
3-1/4” x 10”
rect.
transition
900 elbow
23 Ft. x ( ) = Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.900
elbow
15 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.450
elbow
9 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.900
flat elbow
24 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.
wallcap
with damper
30 Ft. x ( ) = Ft.
Ft. x ( ) = Ft.
15
6”, 7“, 8”
Round
in-line
damper
Installation – Ducting Calculation Sheet
Installation – Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 8” round duct is recommended to
PDLQWDLQPD[LPXPDLUÀRZHI¿FLHQF\
Always use rigid type metal ducts only. Flexible
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
Use calculation worksheet on page 5 to compute
total duct work.
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 8” to 10”.
If turns or transitions are required: Install as far
away from opening and as far apart, between 2,
as possible.
Minimum mount height between range top to hood
bottom should be no less than 26”.
Maximum mount height should be no higher than
34”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will
ORRVHLWVSHUIRUPDQFHDQGHI¿FLHQF\
If available, also refer to range manufacturer’s
height clearance requirements and recommended
hood mounting height above range. Always check
your local codes for any differences.
Duct cover extension kit available for ceiling
heights up to 12 feet. Turn to page 17 for part
number and ordering information.
DAMAGE-SHIPMENT / INSTALLATION:
 3OHDVHIXOO\LQVSHFWXQLWIRUGDPDJHEHIRUH
installation.
 ,IWKHXQLWLVGDPDJHGLQVKLSPHQWUHWXUQWKH
unit to the store in which it was bought for
repair or replacement.
 ,IWKHXQLWLVGDPDJHGE\WKHFXVWRPHUUHSDLU
or replacement is the responsibility of the
customer.
 ,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHULIRWKHU
WKDQWKHFXVWRPHUUHSDLURIUHSODFHPHQWPXVW
be made by arrangement between customer
and installer.
26” min.
34” max.
min. A
min. B
max. C
min. D
min. E
max. F
Standard Extension
Hood Heights Duct Cover Duct Cover
minimum ducted (A) 27-1/2” 46-1/2“
minimum recirculating (B) 32” 50-1/2“
maximum (C) 42” 79”
Ceiling Heights
minimum ducted (D) 89-1/2” (7’5-1/2”) 108-1/2“ (9‘ 1/2”)
minimum recirculating (E) 94” (7’ 10”) 112-1/2“ (9‘ 4-1/2”)
maximum (F) 112” (9’ 4“ ) 149” (12’ 5”)
36”
7
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside, unless using the recirculating option.
Use single wall rigid Metal ductwork only.
)DVWHQDOOFRQQHFWLRQVZLWKVKHHWPHWDOVFUHZVDQGWDSHDOOMRLQWVZFHUWL¿HG6LOYHU7DSHRU'XFW7DSH
Some Ducting Options
Installation – Ducting Options
side wall cap
w/ gravity damper
Soffit or crawl space
Roof Pitch w/
Flashing & Cap
side wall cap
w/ gravity damper
8
www.zephyronline.com
Installation – +RRG6SHFL¿FDWLRQV
Top of Hood
Side of HoodFront of Hood
AC In
C/L
10 1/2”
29 15/16”, 35 7/8”
12 3/8”
STANDARD
min. ducted - 27 1/2”
min. recirc. - 32”
max. - 42”
Z1C-00SI
min. ducted - 46 1/2”
min. recirc. - 50 1/2”
max. - 79”
8 7/16”
21 15/16”
1 9/16”
4 1/4”
7 3/4”
5/8”
4 3/8”
9
1. Measure from range top to hood bottom and mark line A.
´PLQLPXPIURPUDQJHWRS
2. Plum and mark center line.
 0DUNPRXQWLQJKHLJKWOLQH%´IURPOLQH$
0DUNPRXQWLQJKHLJKWOLQH&´IURPOLQH$
5. Mark mounting spread from C/L on line B 12-3/4”
6. Mark mounting spread from C/L on line C 9-7/16”
 )DVWHQ0[´VFUHZVLQWRVWXGVRQOLQH&'RQRW
fasten screws all the way. Note: wood blocking may need
to be added behind the drywall if no studs are present.
Wall anchors may also be used but check local codes
for compliance. Failure to use suitable wall anchors
and screws to hold the weight of the hood could result
in personal injury or damage to cooking surface or
counter.
8. Install 8” round duct collar with backdraft damper to top of
ERG\RIKRRGE\0[ÀDWVFUHZV
 +DQJKRRGRQWRVFUHZVDQGKDQGWLJKWHQ),*$8VH
0[´VFUHZVWRIXUWKHUVHFXUHWKHKRRGWRWKHZDOO
from inside the hood on line B.
10. Center and attach duct cover bracket to wall below ceiling
RUVRI¿WXVLQJ0[´VFUHZV
11. Install electrical.
12. *Install duct work and duct tape.
13. Power up hood and check for leaks around duct tape.
14. Place telescopic duct covers onto hood and extend inner
WRSGXFWFRYHUXSZDUGVDQGVHFXUHWRGXFWFRYHUEUDFNHW
XVLQJ0[VFUHZV
AB
C/L
13-1/8"
9-7/ 16"
C/L
26" min
Duct Cover
Bracket
C
12-3/ 4"
1-5/ 16"
C
B
CAUTION: At least two installers are
required due to the weight and size of the
hood.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!
Installation – Mounting the Hood
FIG. A
The ducting from this fan to the outside of the building has a strong effect on the
DLUÀRZQRLVHDQGHQHUJ\XVHRIWKHIDQ8VHWKHVKRUWHVWVWUDLJKWHVWGXFWURXWLQJ
possible for best performance, and avoid installing the fan with smaller ducts than
recommended. Insulation around the ducts can reduce energy loss and inhibit mold
JURZWK)DQVLQVWDOOHGZLWKH[LVWLQJGXFWVPD\QRWDFKLHYHWKHLUUDWHGDLUÀRZ
10
www.zephyronline.com
Installation – Ductless Recirculating
FOR MODELS ZSI-E30AS and ZSI-E36AS ONLY
Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
IURPFRRNLQJDUHGUDZQDQG¿OWHUHGE\DVHWRIRSWLRQDOFKDUFRDO¿OWHUV7KHDLULVWKHQSXUL¿HGDQGUH
circulated back within the home.
We recommend toALWAYS exhaust air outside of the home by employing existing or installing new duct
ZRUNLISRVVLEOH7KHKRRGLVPRVWHIIHFWLYHDQGHI¿FLHQWDVDQH[KDXVWKRRG2QO\ZKHQWKHH[KDXVWRSWLRQ
is not possible should you recourse to converting the hood into a recirculating hood.
:KHQFRQYHUWHGWREHDUHFLUFXODWLQJKRRGDVHWRIFKDUFRDO¿OWHUVDUHUHTXLUHGRQWRSRILWVVWDQGDUG%DIÀH
)LOWHUVHW2UGHUDFFRUGLQJWRLWV3DUWQXPEHUEHORZ7KHVWDQGDUG%DIÀH)LOWHUVDUHLQWHQGHGWRFDSWXUH
UHVLGXHIURPFRRNLQJDQGWKHRSWLRQDOFKDUFRDO¿OWHUVKHOSWRSXULI\IXPHVH[KDXVWHGIURPFRRNLQJIRUUH
circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
.LWLQFOXGHVFKDUFRDO¿OWHUVFKDUFRDO¿OWHUEUDFNHWVDQGDLUGLYHUWHUSODWH
Hood Model Part No. Filters in Pkg.
ZSI-E30AS ZRC-00SI 2
ZSI-E36AS ZRC-00SI 2
1. Secure air diverter plate to wall below duct cover wall bracket.
 5HPRYHEDIÀH¿OWHUVIURPKRRG3ODFHFKDUFRDO¿OWHURYHUWKHEDFNVLGH
RIEDIÀH¿OWHU
6HFXUHFKDUFRDO¿OWHUVWREDFNVLGHRIEDIÀH¿OWHUVE\IRXUFOLSVIRUHDFK
¿OWHU
 5HLQVWDOOEDIÀH¿OWHUV
 7XUQRQFKDUFRDO¿OWHUFKDQJHLQGLFDWRURQFRQWUROSDQHO
UHIHUWRGHWDLOVRQSDJH7KHPLFURSURFHVVRULQWKHFRQWUROVZLOO
LQGLFDWHWKHQHHGWRFKDQJHWKHFKDUFRDO¿OWHUVDIWHUKRXUVRI
FRQWLQXRXVXVH2UGHUUHSODFHPHQWFKDUFRDO¿OWHUVSHUWKHOLVWEHORZ
NOTE: See manual included with recirculating kit for more detailed
instructions.
Charcoal Filter Replacements
Hood Model Part No. Qty to Order
ZSI-E30AS Z0F-C091 2
ZSI-E36AS Z0F-C091 2
'2127:$6+&+$5&2$/),/7(56&KDUFRDO¿OWHUVPD\QHHG