manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Zephyr
  6. •
  7. Ventilation Hood
  8. •
  9. Zephyr Siena ZSI-E30AS Installation guide

Zephyr Siena ZSI-E30AS Installation guide

Other manuals for Siena ZSI-E30AS

1

This manual suits for next models

3

Other Zephyr Ventilation Hood manuals

Zephyr Tornado II AK8200AS Installation guide

Zephyr

Zephyr Tornado II AK8200AS Installation guide

Zephyr ALU-E43BSX Installation guide

Zephyr

Zephyr ALU-E43BSX Installation guide

Zephyr ZPY-E30AB Installation guide

Zephyr

Zephyr ZPY-E30AB Installation guide

Zephyr ZMI-M90G Installation guide

Zephyr

Zephyr ZMI-M90G Installation guide

Zephyr ZRC-7000C User manual

Zephyr

Zephyr ZRC-7000C User manual

Zephyr Venezia ZVE-E30BS Installation guide

Zephyr

Zephyr Venezia ZVE-E30BS Installation guide

Zephyr CACHE CCA-E36ASX Use Installation guide

Zephyr

Zephyr CACHE CCA-E36ASX Use Installation guide

Zephyr Z1C-00TI User manual

Zephyr

Zephyr Z1C-00TI User manual

Zephyr Venezia ZVE-E30AS User manual

Zephyr

Zephyr Venezia ZVE-E30AS User manual

Zephyr Shade CSH -E42SX Installation guide

Zephyr

Zephyr Shade CSH -E42SX Installation guide

Zephyr Pyramid Installation guide

Zephyr

Zephyr Pyramid Installation guide

Zephyr ZMD-M90BS Installation guide

Zephyr

Zephyr ZMD-M90BS Installation guide

Zephyr Siena Pro Island ZSL-E42AS Installation guide

Zephyr

Zephyr Siena Pro Island ZSL-E42AS Installation guide

Zephyr Monsoon Mini II Installation guide

Zephyr

Zephyr Monsoon Mini II Installation guide

Zephyr ZML-M90BG Installation guide

Zephyr

Zephyr ZML-M90BG Installation guide

Zephyr monsoon mini AK9128AS Installation guide

Zephyr

Zephyr monsoon mini AK9128AS Installation guide

Zephyr Roma ZRO-E36AS Use Installation guide

Zephyr

Zephyr Roma ZRO-E36AS Use Installation guide

Zephyr Siena Pro ZSP-E48BS Installation guide

Zephyr

Zephyr Siena Pro ZSP-E48BS Installation guide

Zephyr Titan AK7636AS Installation guide

Zephyr

Zephyr Titan AK7636AS Installation guide

Zephyr Ombra ZOM-E30BS Installation guide

Zephyr

Zephyr Ombra ZOM-E30BS Installation guide

Zephyr AK7500BS Installation guide

Zephyr

Zephyr AK7500BS Installation guide

Zephyr ZVE-E30DS Installation guide

Zephyr

Zephyr ZVE-E30DS Installation guide

Zephyr Bogart EBO-E42ASX Installation guide

Zephyr

Zephyr Bogart EBO-E42ASX Installation guide

Zephyr Tempest II AK7500ASX Installation guide

Zephyr

Zephyr Tempest II AK7500ASX Installation guide

Popular Ventilation Hood manuals by other brands

Gorenje S3 IHGC963S4X manual

Gorenje

Gorenje S3 IHGC963S4X manual

KOBE ISX2136SQB-1 Installation instructions and operation manual

KOBE

KOBE ISX2136SQB-1 Installation instructions and operation manual

U.S. Products ADVANTAGE-100H Information & operating instructions

U.S. Products

U.S. Products ADVANTAGE-100H Information & operating instructions

Kuppersberg DUDL 4 LX Technical Passport

Kuppersberg

Kuppersberg DUDL 4 LX Technical Passport

Framtid HW280 manual

Framtid

Framtid HW280 manual

Thermador HGEW 36 FS installation manual

Thermador

Thermador HGEW 36 FS installation manual

Electrolux LFT769X user manual

Electrolux

Electrolux LFT769X user manual

AEG X69453MVO UK user manual

AEG

AEG X69453MVO UK user manual

Broan B5836SS manual

Broan

Broan B5836SS manual

Heinner HDCH-6060RGBK quick start guide

Heinner

Heinner HDCH-6060RGBK quick start guide

Baumatic AS35SS instruction manual

Baumatic

Baumatic AS35SS instruction manual

Franke FTF 604 XS V2 Instructions for use and installation

Franke

Franke FTF 604 XS V2 Instructions for use and installation

Best UCB3I30SBW installation instructions

Best

Best UCB3I30SBW installation instructions

Gram EFU 503-90 X instruction manual

Gram

Gram EFU 503-90 X instruction manual

CIARRA CBCS6803 Installation and user manual

CIARRA

CIARRA CBCS6803 Installation and user manual

sauter SHG501 Instructions for installation and use

sauter

sauter SHG501 Instructions for installation and use

Franke 392-17 User instructions

Franke

Franke 392-17 User instructions

FALMEC Polar Black 35 Instruction booklet

FALMEC

FALMEC Polar Black 35 Instruction booklet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
SEP15.0301 © 2015 Zephyr Ventilation LLC.
Siena
ZSI-E30AS
ZSI-E36AS
ZSI-E30AS-ES
ZSI-E36AS-ES
ZSI-E30AS-ES
ZSI-E36AS-ES
5
Duct pieces To t a l
Equivalent number
length x used =
3-1/4” x 10”
Rect.,
straight
1 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.to
6” round
transition
5 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.to
6” round
transition
900 elbow
20 Ft. x ( ) = Ft.
6”, 7”, 8”, 10”
Round,
900
15 Ft.
x ( ) = Ft.
6”, 7”, 8”, 10”
Round,
450
9 Ft. x ( ) = Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) = Ft.
Subtotal column1 =
Duct pieces To t a l
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) = Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) = Ft.
Subtotal column2 =
Subtotal column1 =
Total ductwork =
MaximumDuct Length:For satisfactory air movement,
the total duct length
should not exceed 100 equivalent feet.
6” roundto
3-1/4” x 10”
rect.
transition
1 Ft. x ( ) = Ft.
6” roundto
3-1/4” x 10”
rect.
transition
900 elbow
16 Ft. x ( ) = Ft.
7” roundto
3 1/4” x 10”
rect.
transition
8 Ft. x ( ) = Ft.
7” roundto
3-1/4” x 10”
rect.
transition
900 elbow
23 Ft. x ( ) = Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.900
elbow
15 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.450
elbow
9 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.900
flat elbow
24 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.
wallcap
with damper
30 Ft. x ( ) = Ft.
Ft. x ( ) = Ft.
15
6”, 7“, 8”
Round
in-line
damper
Installation – Ducting Calculation Sheet
Installation – Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 8” round duct is recommended to
PDLQWDLQPD[LPXPDLUÀRZHI¿FLHQF\
Always use rigid type metal ducts only. Flexible
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
Use calculation worksheet on page 5 to compute
total duct work.
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 8” to 10”.
If turns or transitions are required: Install as far
away from opening and as far apart, between 2,
as possible.
Minimum mount height between range top to hood
bottom should be no less than 26”.
Maximum mount height should be no higher than
34”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will
ORRVHLWVSHUIRUPDQFHDQGHI¿FLHQF\
If available, also refer to range manufacturer’s
height clearance requirements and recommended
hood mounting height above range. Always check
your local codes for any differences.
Duct cover extension kit available for ceiling
heights up to 12 feet. Turn to page 17 for part
number and ordering information.
DAMAGE-SHIPMENT / INSTALLATION:
 3OHDVHIXOO\LQVSHFWXQLWIRUGDPDJHEHIRUH
installation.
 ,IWKHXQLWLVGDPDJHGLQVKLSPHQWUHWXUQWKH
unit to the store in which it was bought for
repair or replacement.
 ,IWKHXQLWLVGDPDJHGE\WKHFXVWRPHUUHSDLU
or replacement is the responsibility of the
customer.
 ,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHULIRWKHU
WKDQWKHFXVWRPHUUHSDLURIUHSODFHPHQWPXVW
be made by arrangement between customer
and installer.
26” min.
34” max.
min. A
min. B
max. C
min. D
min. E
max. F
Standard Extension
Hood Heights Duct Cover Duct Cover
minimum ducted (A) 27-1/2” 46-1/2“
minimum recirculating (B) 32” 50-1/2“
maximum (C) 42” 79”
Ceiling Heights
minimum ducted (D) 89-1/2” (7’5-1/2”) 108-1/2“ (9‘ 1/2”)
minimum recirculating (E) 94” (7’ 10”) 112-1/2“ (9‘ 4-1/2”)
maximum (F) 112” (9’ 4“ ) 149” (12’ 5”)
36”
7
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside, unless using the recirculating option.
Use single wall rigid Metal ductwork only.
)DVWHQDOOFRQQHFWLRQVZLWKVKHHWPHWDOVFUHZVDQGWDSHDOOMRLQWVZFHUWL¿HG6LOYHU7DSHRU'XFW7DSH
Some Ducting Options
Installation – Ducting Options
side wall cap
w/ gravity damper
Soffit or crawl space
Roof Pitch w/
Flashing & Cap
side wall cap
w/ gravity damper
8
www.zephyronline.com
Installation – +RRG6SHFL¿FDWLRQV
Top of Hood
Side of HoodFront of Hood
AC In
C/L
10 1/2”
29 15/16”, 35 7/8”
12 3/8”
STANDARD
min. ducted - 27 1/2”
min. recirc. - 32”
max. - 42”
Z1C-00SI
min. ducted - 46 1/2”
min. recirc. - 50 1/2”
max. - 79”
8 7/16”
21 15/16”
1 9/16”
4 1/4”
7 3/4”
5/8”
4 3/8”
9
1. Measure from range top to hood bottom and mark line A.
´PLQLPXPIURPUDQJHWRS
2. Plum and mark center line.
 0DUNPRXQWLQJKHLJKWOLQH%´IURPOLQH$
0DUNPRXQWLQJKHLJKWOLQH&´IURPOLQH$
5. Mark mounting spread from C/L on line B 12-3/4”
6. Mark mounting spread from C/L on line C 9-7/16”
 )DVWHQ0[´VFUHZVLQWRVWXGVRQOLQH&'RQRW
fasten screws all the way. Note: wood blocking may need
to be added behind the drywall if no studs are present.
Wall anchors may also be used but check local codes
for compliance. Failure to use suitable wall anchors
and screws to hold the weight of the hood could result
in personal injury or damage to cooking surface or
counter.
8. Install 8” round duct collar with backdraft damper to top of
ERG\RIKRRGE\0[ÀDWVFUHZV
 +DQJKRRGRQWRVFUHZVDQGKDQGWLJKWHQ),*$8VH
0[´VFUHZVWRIXUWKHUVHFXUHWKHKRRGWRWKHZDOO
from inside the hood on line B.
10. Center and attach duct cover bracket to wall below ceiling
RUVRI¿WXVLQJ0[´VFUHZV
11. Install electrical.
12. *Install duct work and duct tape.
13. Power up hood and check for leaks around duct tape.
14. Place telescopic duct covers onto hood and extend inner
WRSGXFWFRYHUXSZDUGVDQGVHFXUHWRGXFWFRYHUEUDFNHW
XVLQJ0[VFUHZV
AB
C/L
13-1/8"
9-7/ 16"
C/L
26" min
Duct Cover
Bracket
C
12-3/ 4"
1-5/ 16"
C
B
CAUTION: At least two installers are
required due to the weight and size of the
hood.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!
Installation – Mounting the Hood
FIG. A
The ducting from this fan to the outside of the building has a strong effect on the
DLUÀRZQRLVHDQGHQHUJ\XVHRIWKHIDQ8VHWKHVKRUWHVWVWUDLJKWHVWGXFWURXWLQJ
possible for best performance, and avoid installing the fan with smaller ducts than
recommended. Insulation around the ducts can reduce energy loss and inhibit mold
JURZWK)DQVLQVWDOOHGZLWKH[LVWLQJGXFWVPD\QRWDFKLHYHWKHLUUDWHGDLUÀRZ
10
www.zephyronline.com
Installation – Ductless Recirculating
FOR MODELS ZSI-E30AS and ZSI-E36AS ONLY
Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
IURPFRRNLQJDUHGUDZQDQG¿OWHUHGE\DVHWRIRSWLRQDOFKDUFRDO¿OWHUV7KHDLULVWKHQSXUL¿HGDQGUH
circulated back within the home.
We recommend toALWAYS exhaust air outside of the home by employing existing or installing new duct
ZRUNLISRVVLEOH7KHKRRGLVPRVWHIIHFWLYHDQGHI¿FLHQWDVDQH[KDXVWKRRG2QO\ZKHQWKHH[KDXVWRSWLRQ
is not possible should you recourse to converting the hood into a recirculating hood.
:KHQFRQYHUWHGWREHDUHFLUFXODWLQJKRRGDVHWRIFKDUFRDO¿OWHUVDUHUHTXLUHGRQWRSRILWVVWDQGDUG%DIÀH
)LOWHUVHW2UGHUDFFRUGLQJWRLWV3DUWQXPEHUEHORZ7KHVWDQGDUG%DIÀH)LOWHUVDUHLQWHQGHGWRFDSWXUH
UHVLGXHIURPFRRNLQJDQGWKHRSWLRQDOFKDUFRDO¿OWHUVKHOSWRSXULI\IXPHVH[KDXVWHGIURPFRRNLQJIRUUH
circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
.LWLQFOXGHVFKDUFRDO¿OWHUVFKDUFRDO¿OWHUEUDFNHWVDQGDLUGLYHUWHUSODWH
Hood Model Part No. Filters in Pkg.
ZSI-E30AS ZRC-00SI 2
ZSI-E36AS ZRC-00SI 2
1. Secure air diverter plate to wall below duct cover wall bracket.
 5HPRYHEDIÀH¿OWHUVIURPKRRG3ODFHFKDUFRDO¿OWHURYHUWKHEDFNVLGH
RIEDIÀH¿OWHU
6HFXUHFKDUFRDO¿OWHUVWREDFNVLGHRIEDIÀH¿OWHUVE\IRXUFOLSVIRUHDFK
¿OWHU
 5HLQVWDOOEDIÀH¿OWHUV
 7XUQRQFKDUFRDO¿OWHUFKDQJHLQGLFDWRURQFRQWUROSDQHO
UHIHUWRGHWDLOVRQSDJH7KHPLFURSURFHVVRULQWKHFRQWUROVZLOO
LQGLFDWHWKHQHHGWRFKDQJHWKHFKDUFRDO¿OWHUVDIWHUKRXUVRI
FRQWLQXRXVXVH2UGHUUHSODFHPHQWFKDUFRDO¿OWHUVSHUWKHOLVWEHORZ
NOTE: See manual included with recirculating kit for more detailed
instructions.
Charcoal Filter Replacements
Hood Model Part No. Qty to Order
ZSI-E30AS Z0F-C091 2
ZSI-E36AS Z0F-C091 2
'2127:$6+&+$5&2$/),/7(56&KDUFRDO¿OWHUVPD\QHHG
to be changed more often depending on cooking habits.