Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
SEP15.0301 © 2015 Zephyr Ventilation LLC.
Siena
ZSI-E30AS
ZSI-E36AS
ZSI-E30AS-ES
ZSI-E36AS-ES
ZSI-E30AS-ES
ZSI-E36AS-ES
5
Duct pieces To t a l
Equivalent number
length x used =
3-1/4” x 10”
Rect.,
straight
1 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.to
6” round
transition
5 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.to
6” round
transition
900 elbow
20 Ft. x ( ) = Ft.
6”, 7”, 8”, 10”
Round,
900
15 Ft.
x ( ) = Ft.
6”, 7”, 8”, 10”
Round,
450
9 Ft. x ( ) = Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) = Ft.
Subtotal column1 =
Duct pieces To t a l
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) = Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) = Ft.
Subtotal column2 =
Subtotal column1 =
Total ductwork =
MaximumDuct Length:For satisfactory air movement,
the total duct length
should not exceed 100 equivalent feet.
6” roundto
3-1/4” x 10”
rect.
transition
1 Ft. x ( ) = Ft.
6” roundto
3-1/4” x 10”
rect.
transition
900 elbow
16 Ft. x ( ) = Ft.
7” roundto
3 1/4” x 10”
rect.
transition
8 Ft. x ( ) = Ft.
7” roundto
3-1/4” x 10”
rect.
transition
900 elbow
23 Ft. x ( ) = Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.900
elbow
15 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.450
elbow
9 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.900
flat elbow
24 Ft. x ( ) = Ft.
3-1/4” x 10”
Rect.
wallcap
with damper
30 Ft. x ( ) = Ft.
Ft. x ( ) = Ft.
15
6”, 7“, 8”
Round
in-line
damper
Installation – Ducting Calculation Sheet
Installation – Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 8” round duct is recommended to
PDLQWDLQPD[LPXPDLUÀRZHI¿FLHQF\
Always use rigid type metal ducts only. Flexible
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
Use calculation worksheet on page 5 to compute
total duct work.
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 8” to 10”.
If turns or transitions are required: Install as far
away from opening and as far apart, between 2,
as possible.
Minimum mount height between range top to hood
bottom should be no less than 26”.
Maximum mount height should be no higher than
34”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will
ORRVHLWVSHUIRUPDQFHDQGHI¿FLHQF\
If available, also refer to range manufacturer’s
height clearance requirements and recommended
hood mounting height above range. Always check
your local codes for any differences.
Duct cover extension kit available for ceiling
heights up to 12 feet. Turn to page 17 for part
number and ordering information.
DAMAGE-SHIPMENT / INSTALLATION:
 3OHDVHIXOO\LQVSHFWXQLWIRUGDPDJHEHIRUH
installation.
 ,IWKHXQLWLVGDPDJHGLQVKLSPHQWUHWXUQWKH
unit to the store in which it was bought for
repair or replacement.
 ,IWKHXQLWLVGDPDJHGE\WKHFXVWRPHUUHSDLU
or replacement is the responsibility of the
customer.
 ,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHULIRWKHU
WKDQWKHFXVWRPHUUHSDLURIUHSODFHPHQWPXVW
be made by arrangement between customer
and installer.
26” min.
34” max.
min. A
min. B
max. C
min. D
min. E
max. F
Standard Extension
Hood Heights Duct Cover Duct Cover
minimum ducted (A) 27-1/2” 46-1/2“
minimum recirculating (B) 32” 50-1/2“
maximum (C) 42” 79”
Ceiling Heights
minimum ducted (D) 89-1/2” (7’5-1/2”) 108-1/2“ (9‘ 1/2”)
minimum recirculating (E) 94” (7’ 10”) 112-1/2“ (9‘ 4-1/2”)
maximum (F) 112” (9’ 4“ ) 149” (12’ 5”)
36”
7
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside, unless using the recirculating option.
Use single wall rigid Metal ductwork only.
)DVWHQDOOFRQQHFWLRQVZLWKVKHHWPHWDOVFUHZVDQGWDSHDOOMRLQWVZFHUWL¿HG6LOYHU7DSHRU'XFW7DSH
Some Ducting Options
Installation – Ducting Options
side wall cap
w/ gravity damper
Soffit or crawl space
Roof Pitch w/
Flashing & Cap
side wall cap
w/ gravity damper
8
www.zephyronline.com
Installation – +RRG6SHFL¿FDWLRQV
Top of Hood
Side of HoodFront of Hood
AC In
C/L
10 1/2”
29 15/16”, 35 7/8”
12 3/8”
STANDARD
min. ducted - 27 1/2”
min. recirc. - 32”
max. - 42”
Z1C-00SI
min. ducted - 46 1/2”
min. recirc. - 50 1/2”
max. - 79”
8 7/16”
21 15/16”
1 9/16”
4 1/4”
7 3/4”
5/8”
4 3/8”
9
1. Measure from range top to hood bottom and mark line A.
´PLQLPXPIURPUDQJHWRS
2. Plum and mark center line.
 0DUNPRXQWLQJKHLJKWOLQH%´IURPOLQH$
0DUNPRXQWLQJKHLJKWOLQH&´IURPOLQH$
5. Mark mounting spread from C/L on line B 12-3/4”
6. Mark mounting spread from C/L on line C 9-7/16”
 )DVWHQ0[´VFUHZVLQWRVWXGVRQOLQH&'RQRW
fasten screws all the way. Note: wood blocking may need
to be added behind the drywall if no studs are present.
Wall anchors may also be used but check local codes
for compliance. Failure to use suitable wall anchors
and screws to hold the weight of the hood could result
in personal injury or damage to cooking surface or
counter.
8. Install 8” round duct collar with backdraft damper to top of
ERG\RIKRRGE\0[ÀDWVFUHZV
 +DQJKRRGRQWRVFUHZVDQGKDQGWLJKWHQ),*$8VH
0[´VFUHZVWRIXUWKHUVHFXUHWKHKRRGWRWKHZDOO
from inside the hood on line B.
10. Center and attach duct cover bracket to wall below ceiling
RUVRI¿WXVLQJ0[´VFUHZV
11. Install electrical.
12. *Install duct work and duct tape.
13. Power up hood and check for leaks around duct tape.
14. Place telescopic duct covers onto hood and extend inner
WRSGXFWFRYHUXSZDUGVDQGVHFXUHWRGXFWFRYHUEUDFNHW
XVLQJ0[VFUHZV
AB
C/L
13-1/8"
9-7/ 16"
C/L
26" min
Duct Cover
Bracket
C
12-3/ 4"
1-5/ 16"
C
B
CAUTION: At least two installers are
required due to the weight and size of the
hood.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!
Installation – Mounting the Hood
FIG. A
The ducting from this fan to the outside of the building has a strong effect on the
DLUÀRZQRLVHDQGHQHUJ\XVHRIWKHIDQ8VHWKHVKRUWHVWVWUDLJKWHVWGXFWURXWLQJ
possible for best performance, and avoid installing the fan with smaller ducts than
recommended. Insulation around the ducts can reduce energy loss and inhibit mold
JURZWK)DQVLQVWDOOHGZLWKH[LVWLQJGXFWVPD\QRWDFKLHYHWKHLUUDWHGDLUÀRZ
10
www.zephyronline.com
Installation – Ductless Recirculating
FOR MODELS ZSI-E30AS and ZSI-E36AS ONLY
Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
IURPFRRNLQJDUHGUDZQDQG¿OWHUHGE\DVHWRIRSWLRQDOFKDUFRDO¿OWHUV7KHDLULVWKHQSXUL¿HGDQGUH
circulated back within the home.
We recommend toALWAYS exhaust air outside of the home by employing existing or installing new duct
ZRUNLISRVVLEOH7KHKRRGLVPRVWHIIHFWLYHDQGHI¿FLHQWDVDQH[KDXVWKRRG2QO\ZKHQWKHH[KDXVWRSWLRQ
is not possible should you recourse to converting the hood into a recirculating hood.
:KHQFRQYHUWHGWREHDUHFLUFXODWLQJKRRGDVHWRIFKDUFRDO¿OWHUVDUHUHTXLUHGRQWRSRILWVVWDQGDUG%DIÀH
)LOWHUVHW2UGHUDFFRUGLQJWRLWV3DUWQXPEHUEHORZ7KHVWDQGDUG%DIÀH)LOWHUVDUHLQWHQGHGWRFDSWXUH
UHVLGXHIURPFRRNLQJDQGWKHRSWLRQDOFKDUFRDO¿OWHUVKHOSWRSXULI\IXPHVH[KDXVWHGIURPFRRNLQJIRUUH
circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
.LWLQFOXGHVFKDUFRDO¿OWHUVFKDUFRDO¿OWHUEUDFNHWVDQGDLUGLYHUWHUSODWH
Hood Model Part No. Filters in Pkg.
ZSI-E30AS ZRC-00SI 2
ZSI-E36AS ZRC-00SI 2
1. Secure air diverter plate to wall below duct cover wall bracket.
 5HPRYHEDIÀH¿OWHUVIURPKRRG3ODFHFKDUFRDO¿OWHURYHUWKHEDFNVLGH
RIEDIÀH¿OWHU
6HFXUHFKDUFRDO¿OWHUVWREDFNVLGHRIEDIÀH¿OWHUVE\IRXUFOLSVIRUHDFK
¿OWHU
 5HLQVWDOOEDIÀH¿OWHUV
 7XUQRQFKDUFRDO¿OWHUFKDQJHLQGLFDWRURQFRQWUROSDQHO
UHIHUWRGHWDLOVRQSDJH7KHPLFURSURFHVVRULQWKHFRQWUROVZLOO
LQGLFDWHWKHQHHGWRFKDQJHWKHFKDUFRDO¿OWHUVDIWHUKRXUVRI
FRQWLQXRXVXVH2UGHUUHSODFHPHQWFKDUFRDO¿OWHUVSHUWKHOLVWEHORZ
NOTE: See manual included with recirculating kit for more detailed
instructions.
Charcoal Filter Replacements
Hood Model Part No. Qty to Order
ZSI-E30AS Z0F-C091 2
ZSI-E36AS Z0F-C091 2
'2127:$6+&+$5&2$/),/7(56&KDUFRDO¿OWHUVPD\QHHG
to be changed more often depending on cooking habits.

Other manuals for Siena ZSI-E30AS

1

This manual suits for next models

3

Other Zephyr Ventilation Hood manuals

Zephyr ZTR-M90S Installation guide

Zephyr

Zephyr ZTR-M90S Installation guide

Zephyr Pisa ZPI-E24BG Installation guide

Zephyr

Zephyr Pisa ZPI-E24BG Installation guide

Zephyr ALL-E42ABX User manual

Zephyr

Zephyr ALL-E42ABX User manual

Zephyr Venezia ZVE-E30AS User manual

Zephyr

Zephyr Venezia ZVE-E30AS User manual

Zephyr Monsoon I Installation guide

Zephyr

Zephyr Monsoon I Installation guide

Zephyr Siena Pro Island ZSL-E42AS Installation guide

Zephyr

Zephyr Siena Pro Island ZSL-E42AS Installation guide

Zephyr AK7036BS Installation guide

Zephyr

Zephyr AK7036BS Installation guide

Zephyr AK0710 Installation guide

Zephyr

Zephyr AK0710 Installation guide

Zephyr ES1-E30AB Installation guide

Zephyr

Zephyr ES1-E30AB Installation guide

Zephyr ZSL-E48BS Installation guide

Zephyr

Zephyr ZSL-E48BS Installation guide

Zephyr Pisa ZPI-E24BG Installation guide

Zephyr

Zephyr Pisa ZPI-E24BG Installation guide

Zephyr CACHE CCA-E36ASX Use Installation guide

Zephyr

Zephyr CACHE CCA-E36ASX Use Installation guide

Zephyr Ravenna ZRV-E30AGC Installation guide

Zephyr

Zephyr Ravenna ZRV-E30AGC Installation guide

Zephyr SAVONA ZSA-E30AS Installation guide

Zephyr

Zephyr SAVONA ZSA-E30AS Installation guide

Zephyr Z1C-00SU User manual

Zephyr

Zephyr Z1C-00SU User manual

Zephyr Duo Wall ADU - M90ASX User manual

Zephyr

Zephyr Duo Wall ADU - M90ASX User manual

Zephyr ALA-M90BBX Product manual

Zephyr

Zephyr ALA-M90BBX Product manual

Zephyr Willow AK8800AG Technical manual

Zephyr

Zephyr Willow AK8800AG Technical manual

Zephyr AK08 S Series User manual

Zephyr

Zephyr AK08 S Series User manual

Zephyr Typhoon AK2100 Installation guide

Zephyr

Zephyr Typhoon AK2100 Installation guide

Zephyr elica Glide Installation guide

Zephyr

Zephyr elica Glide Installation guide

Zephyr Pyramid ZPY-E30S Installation guide

Zephyr

Zephyr Pyramid ZPY-E30S Installation guide

Zephyr AK6536 Installation guide

Zephyr

Zephyr AK6536 Installation guide

Zephyr Titan AK7636AS Installation guide

Zephyr

Zephyr Titan AK7636AS Installation guide

Popular Ventilation Hood manuals by other brands

ROBLIN Tiroir 612 instruction manual

ROBLIN

ROBLIN Tiroir 612 instruction manual

AEG DE 6261 user manual

AEG

AEG DE 6261 user manual

DeDietrich DHD497XE1 Instructions for installation and use

DeDietrich

DeDietrich DHD497XE1 Instructions for installation and use

Dacor DHI361 use and care manual

Dacor

Dacor DHI361 use and care manual

Faber Chloe Installation instructions; use and care information

Faber

Faber Chloe Installation instructions; use and care information

Artusi CAID64X Operation manual

Artusi

Artusi CAID64X Operation manual

Faber DAISY + BK A80/2 manual

Faber

Faber DAISY + BK A80/2 manual

Atag WU7111HM Instructions for use

Atag

Atag WU7111HM Instructions for use

NuTone RLX6100 Series instructions

NuTone

NuTone RLX6100 Series instructions

Electrolux EFP 6446 Installation and operating instructions

Electrolux

Electrolux EFP 6446 Installation and operating instructions

Bosch DWB06W452B installation instructions

Bosch

Bosch DWB06W452B installation instructions

Accurex XB Installation, operation and maintenance manual

Accurex

Accurex XB Installation, operation and maintenance manual

AIRLUX XHD541A-C-H User instructions

AIRLUX

AIRLUX XHD541A-C-H User instructions

GE ZV900SLSS user manual

GE

GE ZV900SLSS user manual

Mx Onda MX-CDP2682 User and installation manual

Mx Onda

Mx Onda MX-CDP2682 User and installation manual

ETNA AO561WIT Instructions for use

ETNA

ETNA AO561WIT Instructions for use

Zanussi ZHS92450XA user manual

Zanussi

Zanussi ZHS92450XA user manual

Kenmore 233.52052 owner's manual

Kenmore

Kenmore 233.52052 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.