ZKaccess C3-100 User manual

InstructionsforInstallationandUseof
theC3100/200/400ControlPanel
Version:1.0.1
Date: Oct. 2010
AboutThisManual
ThismanualisaguidetoinstallationandconnectionoftheC3100/200/400access
controloperatorpanel.Forhowtousethesoftwareoftheproduct,seeZKAccess4.0
UserManual.

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
I
Contents
1ImportantSecurityInstructions.......................................................................1
1.1Important SecurityInstructions.................................................................1
1.2InstallationCautions.................................................................................2
2Introduction......................................................................................................5
2.1SystemFunctionParameters.....................................................................5
2.2ProductTechnicalParameters ...................................................................5
2.3ControlOperatorPanelIndicators.............................................................6
3ConnectionandInstallation..............................................................................8
3.1CaseInstallation.......................................................................................8
3.2InstallationofAccessControlOperatorPanelWires..................................9
3.3ControlOperatorPanelSystemInstallation .............................................10
3.4ControlOperatorPanelConnectionTerminals.........................................12
3.5ConnectionwithDoorSensors,ExitSwitches,andAuxiliaryInputDevices
...................................................................................................................16
3.6ConnectionwithWiegandReaders..........................................................18
3.7RelayOutputConnection........................................................................20
3.8AccessControlOperatorPanelSystemPowerSupplyStructure...............25
4AccessControlOperatorPanelSystemNetworking ......................................27
4.1AccessControlNetworkingWiresandWiring.........................................27
4.2TCP/IPNetworkCommunication............................................................29
4.3RS485NetworkCommunication ............................................................29

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
II
4.4 DIP Switch Setting (485 Address Setting, Factory Setting, and Terminal
ResistanceSetting).......................................................................................31

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
1
1ImportantSecurityInstructions
1.1ImportantSecurityInstructions
1. Read,followandkeepinstructions:Beforeoperatingtheequipment,readand
follow strictly all security and operation instructions. Please keep the
instructionsingoodconditionforfuturereference.
2. Accessories: Pleaseusetheaccessories recommendedbythemanufactureror
deliveredwiththeproduct. Anyotherrelated productisnotrecommendedas
the major alarming or monitoringsystem. The majoralarming ormonitoring
system should comply with the local applicable fireprevention and security
standards.
3. Installationcautions:Donotplacethisequipmentonanyunstabletable,tripod
mount, support or base, lest the equipmentshouldfall and get damaged, and
more undesirably cause severe personal injuries.Therefore, it isimportant to
installtheequipmentasinstructedbythemanufacturer.
4. Allperipheraldevicesmustbegrounded.
5. No external connection wirescan be exposed. All connectionsand idle wire
endsmustbewrappedwithinsulatingtapestopreventaccidentalcontactwith
exposedwiresfromdamagingtheequipment.
6. Repair:Donotattemptunauthorizedrepairoftheequipment.Disassemblyor
detachment is likely to cause shock or other risks. All repair jobs should be
donebyqualifiedrepairpersonnel.
7. Damagesinneed ofrepair:Inanyofthefollowingcases,firstdisconnectthe
AC/DC power supply from the equipment and notify qualified repair
personnel forrepairs:
Thepowercordorconnectorisdamaged.
Thereisentryofliquidoranyotherforeignobjectintotheequipment.
Theequipmentiswettedorexposedtobadweather(rain,snow,etc.).

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
2
If the equipment cannot work normally even though operated as
instructed,pleasebesuretoadjustonlythecontrolcomponentsspecified
in the operation instructions. Incorrect adjustment of other control
components may cause damage to the equipment, and add to
troubleshootingworkloadofthequalifiedtechnicians.
Theequipmentfallsdownoritsperformancechangesobviously.
8. Replacing components: If it is necessary to replace a component, the repair
personnelmustuseonlythesubstitutesspecifiedbythemanufacturer.
9. Security inspection: After the equipmentis repaired,the repair personnel are
supposed to conduct security inspection to ensure the equipment can work
normally.
10. Power supply: Operate the equipment with only the type of power supply
indicatedonthelabel.Contacttheoperatorforanyuncertaintyaboutthetype
ofpowersupply.
1.2InstallationCautions
1. Allwiresmustrunthroughcasingpipes,forexamplePVCorgalvanizedpipes,to
prevent failure causedby rodent damage.Although a control panel is designed
with good antistatic, lightningproof, andleakageproof functions, ensureits
chassisand the AC ground wireare connected properly and theAC ground
wireisgroundedphysically.

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
3
2. It is recommended not to plug/unplug connectionterminals frequently when
the system is energized. Be sure to unplug the connection terminals before
startinganyrelevantweldingjob.
3. Do not detach or replace any control panel chip withoutpermission, because
unprofessionaloperationmaycausedamagetothecontrolpanel.
4. It is recommended not to connect any other auxiliary devices without
permission. All nonroutine operations must be communicated to our
engineersinadvance.
5. A control panel should not share one power socket with any other
largecurrentdevice.
6. Itispreferabletoinstallcardreadersandbuttonsatheightsof1.41.5m above
the ground, but the heights are subject to proper adjustment according to
customers’usualpractice.
7. It is advised to install control panels at places easy of maintenance, like a
weakelectricwell.
8. It is strongly recommended that the exposed part of any connection terminal
shouldnotbelongerthan4mm,andspecializedclampingtoolsmaybeused
to avoid shortcircuit or communication failure resulting from accidental
contactwithexcessiveexposedwires.
9. To save access control event records, read data periodically from control
panels.
10. Get prepared countermeasures according to application scenarios for
unexpectedpowerfailure,like selectingpowersupplywithUPS.
11. The connection between a card reader and a control panel should not be
longerthan100m.
12. The connection between a PC and a control panel should be shorter than
1200mforRS485communications.Alengthwithin600m isrecommendedto
makecommunicationsmorestable.

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
4
13. To protect the access control system against the selfinduced electromotive
force generated by an electronic lock at the instant of switching off/on, it is
necessaryto connectadiodeinparallel (pleaseusetheFR107deliveredwith
thesystem) with theelectronic lockto releasethe selfinduced electromotive
forceduringonsiteconnectionforapplicationoftheaccesscontrolsystem.
14. It is recommended that an electronic lock and a control panel should use
respectivepowersupplies.
15. It isrecommended to usethe power supply delivered with the system asthe
controlpanelpowersupply.
16. Inaplacewithstrongmagneticinterference,galvanizedsteelpipesorshielded
cables arerecommended, andpropergroundingisrequired.

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
5
2Introduction
Theaccesscontrolmanagementsystemisanewmodernizedsecuritymanagement
system,whichisaneffectivemeasureforsecurityandprotectionmanagement.Itis
mainlyusedtomanageentrancesandexitsofimportantplaces, suchas banks,hotels,
equipmentrooms,offices,smartcommunities,andfactories.
2.1SystemFunctionParameters
Highspeed32bit400MHzCPU,32MRAM,and256MFlash.
EmbeddedLINUXoperatingsystem.
Onedoor/twodoortwowayaccessorfourdooronewayaccess.
Amaximumof30,000cardholdersand100,000offlineeventrecords.
SupportofmultipleWiegandcardformatsandapasswordkeypad,compatible
withvarioustypesofcards.
Use of dual communication technologies: the Ethernet plus the RS485
industrialbus,forreliablecommunications.
Withawatchdog(hardware)builtin thecontrolpaneltopreventcrash.
Overcurrent, overvoltage, and inversevoltage protection for input of power
supplyto the controlpanel.
Overcurrentprotectionforthepowersupplytocardreaders.
Instantovervoltageprotectionforallinput/outputports.
Instantovervoltageprotectionforcommunicationports.
2.2ProductTechnicalParameters
Workingpowersupply:ratedvoltage12V(±20%)DC;ratedcurrent≤0.5A.
Workingenvironment:temperature0°C55°C;humidity10%80%.

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
6
Outputload:workingvoltageAC≤30V,ratedcurrent≤8A;DC≤36V,rated
current≤5A.
Ctype electronic lock relay output terminal: 10A contact current, 12V DC,
withLEDstatusindications.
Outputterminaloftheauxiliaryrelay:2Acontactcurrent,30VDC,withLED
statusindications.
Withdetachableconnectionterminalsmadeofalloysteelnonmagneticflange
materials.
OutlinedimensionsofthecontrolPCB:160mm(length)×106mm(width)for
C3100/200;218mm(length)×106mm(width)forC3400.
MountingholedimensionsofthecontrolPCB:147.32mm(length)×91.44mm
(width)forC3100/200;203.2mm(length)×106mm(width)forC3400.
External boxdimensions:345mm×275mm×70mm.
2.3ControlOperatorPanelIndicators
WhentheC3100/200/400ispoweredon,normallythePOWERindicator(red)islit
constantly,theRUNindicator(green)flashes(indicatingthesystemisnormal),and
otherindicatorsarealloff.
Exceptthecasesasfollows:
1. LINK indicator (green): indicates proper TCP/IP connection if it is lit
constantly;
2. ACTindicator(yellow):indicatestransmissionofTCP/IPdataifitflashes;
3. TXindicator(yellow):indicatessendingof485dataifitflashes;
4. RXindicator(green):indicatesreceivingof485dataifitflashes;
5. Lock indicator (green): indicates unlocking if it is lit constantly (if the
auxiliary output indicator is lit in green constantly, it indicates the auxiliary
deviceisenabled);
6. CARDindicator(yellow):indicatesinputofWiegandsignalifitislit.

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
7
SeetheC4indicatorsinthefollowingfigure:
Figure21IndicatorsintheC3400

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
8
3ConnectionandInstallation
3.1CaseInstallation

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
9
3.2InstallationofAccessControlOperatorPanel
Wires
Figure31 AccessControl OperatorPanelWireInstallationDiagram
Notes:
1. Before connection, make sure the power supply is disconnected, because
connectionwithpowerconnectedwillcauseseveredamagetotheequipment.
2. The access control wires must be separated according to heavy and light
current; the control panel wires, electronic lock wires, and exit button wires
mustrunthroughtheir respectivecasingpipes.

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
10
3.3ControlOperator PanelSystemInstallation
TCP/IPEthernet Hub
Managementhost
Printer
Cardissuer
C3400 controloperatorpanel
Internal
button
Cardreader 1 Cardreader2 Cardreader3 Cardreader 4
Controllingonewayentry/exitoffourdoors
Controllingtwowayentry/exitoftwodoors
Door1 Door2 Door3 Door4
Door1 Door2
Internal
button
Internal
button
Internal
button
Figure32 SchematicDiagramofC3400SystemInstallation

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
11
Note: The diagram above takes the C3400 for example. By contrast, only
onedoor twoway access isapplicable tothe C3100 system; only twodoor
onewayortwodoortwoway accessisapplicabletotheC3200system.
The access control management system consists of two parts: management
workstation (PC) and control operator panel. They communicate via TCP/IP and
RS485 networks. On a 485 bus, each management workstation can be connected
with up to 63 C3 control operator panels (preferably fewer than 32). The
communication wires should be kept away from highvoltage wires as far as
possible,andshouldbe neitherroutedinparallelwithnorbundledwithpowerwires.
A management workstation isactually a PC connectedto the network. By running
the access control management software installed in the PC, access control
management personnel can remotely perform various management functions, like
adding/deleting a user, viewing event records, opening/closing doors, and
monitoringstatusofeachdoorinrealtime.

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
12
3.4ControlOperator PanelConnectionTerminals
C3100terminalconnectiondiagram

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
13
C3200terminalconnectiondiagram

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
14
C3400terminalconnectiondiagram

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
15
Descriptionsoftheterminals:
1. The auxiliary input may be connected to infrared body detectors, fire
alarms,smokedetectors,etc.
2. The auxiliary output may be connectedto alarms, cameras, door bells,
etc.
3. Alltheterminalsmentionedabovearesetthroughrelevantaccesscontrol
software.Pleaseseetherespectivesoftwareinstructionsfordetails.
PortsontheC3control operator panel:
No. FunctionalPort
C3100
(OneDoor
TwoWay)
C3200
(TwoDoor
TwoWay)
C3400
(FourDoor
OneWay/TwoD
oorTwoWay)
1 Wiegand card reader
interface2 4 4
2 Exitbutton1 2 4
3 Controllockrelay1 2 4
4 Doorsensor1 2 4
5 Extensioninput× 2 4
6 Extensionoutput1 2 4
7 RS485 & PC
communication√ √ √
8 RS485 extension
communication× √ √
9 TCP/IP√ √ √

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
16
3.5ConnectionwithDoorSensors,ExitSwitches,and
AuxiliaryInputDevices
Doorsensor
A door sensorisusedtosensetheopen/closedstatusofadoor.Withadoor sensor
switch,anaccesscontrolpanelcandetectillegalopeningofadoor,andwilltrigger
an output of alarm. Moreover, if a door isnot closed within a specified period of
time after it is opened, the door control panel will also prompt an alarm. It is
recommendedtoselecttwocorewireswitha gauge over0.22mm
2
. Adoorsensormaybe
omittedifitisunnecessarytomonitoronlinetheopen/closedstatusofadoor,giveoutan
alarm whenthedoorisnot closed for a longtime orthere isillegal access, and use the
interlockfunction.
Exitswitch
Anexitswitchisaswitchinstalledindoorstoopenadoor.Whenitisswitchedon,
thedoorwillbeopened.Anexitbuttonisfixedataheightofabout1.4mabovethe
ground.Ensureitislocatedintherightpositionwithoutslant,anditsconnectionis
correct and secure.(Cut off the exposed end of any unused wireand wrap it with
insulating tape.) Note to guard against electromagnetic interference (such as light
switches and computers). Itisrecommended to usetwocorewireswith agaugeover
0.3mm
2astheconnectionwirebetweenanexitswitchandacontrolpanel.
Auxiliaryinput
C3100 provides no auxiliary input interface; C3200 provides two, and C3400
providesfour,whichareconnectedtoinfraredbodydetectors,smokedetectors,gas
detectors,windowmagneticalarms,wirelessexitswitches,etc.Auxiliaryinputsare
set through relevant access control software. For details, please see ZKAccess4.0
UserManual.

InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
17
Figure33ConnectionsbetweenC3400andDoorSensors,ExitSwitches,and
AuxiliaryInputDevices
This manual suits for next models
4
Other ZKaccess Control Panel manuals
Popular Control Panel manuals by other brands

Sony
Sony RCP-3100 operating instructions

DMP Electronics
DMP Electronics XT Series Installation & quick start guide

Honeywell
Honeywell MB-Secure 1000 installation instructions

CAME
CAME ZE5 V.7 installation manual

Risco
Risco LightSYS Quick user guide

SILENTRON
SILENTRON 4001 Centrale Sil-Bus 4A instruction manual