ZKaccess C3-200 User manual

www.zkteco.com

Safety Precautions
Product Contents
Product
PIN Diagram
LED
indicators
Product Dimension
Installation of Panel with Casing
Wire Legend
Power
Wiring Diagram
WEIGAND Connection
Exit button Connection
Lock connection
Door
Sensor Connection
Aux. Input Connection
Aux. Output Connection
Ethernet Connection
RS485 Connection
DIP switch settings
Electrical
Specifications
Troubleshooting
Specification
s
1
02
04
06
06
07
08
09
10
11
11
12
12
14
14
15
16
17
18
19
20

1
2
Safety Precautions
Do not install the device in a
place subject to direct sun light,
humidity, dust or soot.
Do not place a magnet near the
product. Magnetic objects such as
magnet, CRT, TV, monitor or speaker
may damage the device.
Do not place the device next to
heating equipment
Be careful not to let liquid like
water, drinks or chemicals leak
inside the device.
Clean the device often to remove
dust on it
01 02 03
04 05 06
Do not let children touch the
device without supervision.
The list below is to keep user’s safety and prevent any loss. Please read carefully before installation.

3
Safety Precautions
The list below is to keep user’s safety and prevent any loss. Please read carefully before installation.
Do not drop the device. Do not use the device for any
other purpose than specified.
Do not disassemble, repair or
alter the device.
07 08
In cleaning, do not splash water
on the device but wipe it out with
smooth cloth or towel.
09
Contact your nearest dealer in
case of a problem.
Do not damage the device
10 11 12

4
Product Contents
Basic Contents
C3-200
Wall mounting screws –2 pcs. Wall Plugs–2 pcs. Surge Suppressing Diode–4 pcs.
screw driver –2 pcs. Software CD C3 installation guide

5
Product Contents
Optional accessories
Weigand Card Reader Prox Card
Card enroller
Door Sensor
K1-1 Exit Button
Alarm C3 Metal Case
RS485 convertor

6
Product PIN Diagram
#2 Door Card
Reader 2
#2 Door Card
Reader 1
#1 Door Card
Reader1
#1 Door Exit
Button
Aux Input 4
Aux Input 1
SD Card Slot
LINK LED
ACT LED
Ethernet Port
DIP Switch
PC RS485 Port
Aux Output 1
Aux Output 2
Lock Power
C3 Power
LED indicators
LINK
(Green)
LED solid green indicates
TCP/IP communication is
normal
ACT
(Yellow)
Flashing LED indicates data
communication is in
progress
PC RS485
(Yellow &
Green)
Flashing LED is sending or
data in communication
progress
POWER
(Red)
Flashing LED indicates the
panel is powered on.
RUN
(Green)
Flashing LED indicates that
panel is in normal working
state
CARD
(Yellow)
Flashing LED indicates that
the card is read by the panel.
Reserved
485 LED
Status LED
#1 Lock Sensor
#1 Door Lock
#2 Lock Sensor
#1 Door Lock
#1 Door Card
Reader2
#2 Door Exit
Button

7
C3-200
Product Dimension
Dimension(L*W):203.2×106 (mm)
6.30 ×4.17(inches)
160mm
(6.30in.)
106mm
(4.17in.)
C3-Casing
400mm
(15.7in.)
330mm
(13.0in.)
330mm
(13.0in.)
90.5mm
(3.56in.) Dimensions(L*W*H): 400 *90.5*330(mm)
15.7× 13.0× 3.56(inches)

8
Installation of Panel & Case
Metal Case
Heat dissipation
Hole
Cable Conduit
Box Lock Hole Power Supply
Backup Battery
C3 Panel
Thread Hole
Wires need to be passed through
this conduit
Mounting the case on the wall

Wire Legend
9
Detector Infrared sensors #1Exit Switch #1Card Reader #2 K1-1 Exit Switch #2 Card Reader
12V
Power Supply
Normal Close Lock
Normal Open Lock
Alarm
RS485 Convertor
LAN Cable
Floodlight
12V DC
Power
DC

Power wiring diagram
10
AC
AC
Switching power supply
C3-200
AC
AC
Switching power supply
C3-200
Backup Battery
+
-
Without
Backup Battery
With
Backup Battery
110-220V
110-220V

Weigand Connection
11
Weigand Card Reader
Exit Button Connection
Beeper
Green LED
Weigand D1
Weigand D0
GND
DC+(6-14V)
BUT
GND
DV12V(+)
DV12V(-)
NO
COM
NC
separate power supply
Notice:
ZK ABK Exit Button
K1-1 Exit Switch

12
Lock Connection
Built-in Power Supply
Built-in Power Supply
Sensor
Sensor
GND
12V DC
12V DC
GND
Sensor
Sensor
GND
12V DC
12V DC
GND
FR107
FR107
For Normally Open Lock
For Normally Close Lock

Lock Connection
13
Switching Wet Contact to Dry Contact
Important Notes:
C3-200 is set to supply lock power by default from
external power supply , If you want to use built-in
power supply , you must do the following:
1. Select the wanted lock relay and find its
jumpers
2. Take off the jumpers and change to
3. Connect the lock as shown in the diagram below
Steps:
C3-200 Select one Relay
FR107
GND
12V DC
SEN SEN GND 12V DC
4 Lock Relays
Default setting
1
5
Take off jumpers
JumpersPlug Jumpers
Changed setting
5 1
Connecting a lock with external power supply

14
Aux. I/O connection
Aux. Input Connection
Aux. output Connection
COM
NO
NC
GND
12V DC
COM
NO
NC
GND
12V DC

15
Ethernet Connection
Direct connection
Important Notes:
1. Both 10Base-T and 100Base-T
are supported
2. This cable distance must be less
than 100 meters or 330 ft.
3. For cables length of more than
100m. use HUB to amplify the
signal
TCP/IP
CR10 Card Issuer
The CR10 is connected to the server using USB
connection.
To connect C3-200 with a PC directly, connect both devices with a straight network cable. As the C3-200 supports auto MDI/MDIX , it
is not necessary to use a crossover type cable.
CR10 Card Issuer
C3-200 C3-200

16
RS485 Connection
Important Notes
#1 C3-200
#63 C3-200
RS485-
RS485+
GND
1. RS485 communication wires should be shielded or twisted pair calble.
RS485 communication wires should be connected in a bus cascade instead
of in a star form, to achieve a better shielding effect by reducing signal
reflection during communications.
2. A single 485 bus can be connected with 63 access control panels at the
most, but preferably less than 32 panels should be connected.
3. To eliminate signal attenuation in communication cables and suppress
interference, if the bus is longer than 200 meters, set the number 8 DIP
switch to the ON position. This is equivalent to a parallel connection of one
120ohm resistance between the 485+ and 485- lines.
Distance
More than 200 meters
#1 C3-200 #* C3-200
Do's and Dont's for RS 485 connection

17
DIP Switch Setting
Introduction RS485 Address
1. Number 1-6 are reserved to set the device number for RS485
communication. The code is binary, and the numbering starts from left to
right. When the switch is set to ON position, it indicates 1 (on); when the
switch is set downwards, it indicates 0 (off). For example, to set a device
number 39=1+2+4+32, which corresponds to the binary code 111001, put
number 1, 2, 3, and 6 to ON position, as illustrated below.
2. For more details, please check the table at the end of this document
Restore factory setting
1. If you forget the C3 IP address or the device does not work
normally, you can use the number 7 terminal to restore C3-200 to
factory default settings. The parameters which gets reset are
device IP address, communication password ,gateway ,subnet mask.
2. The switch is OFF by default. When it is moved upwards and
downwards for three times within 10 seconds and finally returned
to OFF position, the factory settings will be restored after the
access control panel is restarted.
1 times 2 times 3 times OFF
Terminal Resistance
1. Number 8 is for setting the RS485 termination resistance. Putting the
switch to ON position is equivalent to parallel connection of a 120ohm
termination resistance between 485+ and 485-
2. For more information please read RS485 connection - important notes
120ohm

Electrical Specifications
18
Min. Typ. Max. Notes
Working power supply
Voltage(V) 9.6 12 14.4 Use regulated DC power adaptor only
Current(A) 2
Electronic lock relay output
Switching voltage(V) 36V Use regulated DC power adaptor only
Switching Current(A) 2
Auxiliary relay output
Switching voltage(V) 36V Use regulated DC power adaptor only
Switching Current(A) 1.25
Switch Aux. input
VIH (V) TBD
VIL (V) TBD
Pull-up resistance (Ω) 4.7k The input ports are pulled up with 4.7k resistors
WIEGAND Input
Voltage(V) 10.8 12 13.5
Current(mA) 500
ZK Electronic lock
Voltage(V) 10.8 12 13.2
Current(mA) 500

Troubleshooting
19
1. How to switch four door one way to two door to way.
Connect four readers from reader 1 to reader 4.
Connect two door locks , one connect LOCK1 ,another connect LOCK3.
Switch on software then reader 1-Indoor, reader 2-Outdoor.
2. How many WEIGAND formats are supported ?
The panel is set to read 26 bit by default.
However there are 9 other bit formats which can be selected from the software. In addition you
can also define your custom bit format.
3. How many verification mode can be support.
Card only
Password only
Card plus password
4. Can we integrate IP Camera and NVR
Currently ZKACCESS software supports ZKAccess’ IP Cameras and NVR
You can associate a camera to the door and setup a linkage for the same.
5. Can C3 panel support FR1200 fingerprint reader ?
No , Only Inbio series can support FR1200 fingerprint reader
Diagram:
Table of contents
Other ZKaccess Control Panel manuals
Popular Control Panel manuals by other brands

Menvier Security
Menvier Security TS790+ Installation and programming manual

Rosslare
Rosslare AC-425-B Hardware installation and user's guide

Pego
Pego ECP300 EXPERT VD Series Use and maintenance manual

Texecom
Texecom Premier 888 user manual

AGS
AGS Parksafe Control Panel Installation operation & maintenance

GE
GE NX-1308E - Caddx 8 Zone LED Keypad Installation and startup guide