4.1 Ground Fault Circuit Interrupter
WARNING
When using electrical products, basic precautions
should always be followed, including the following:
• DANGER: RISK OF ELECTRIC SHOCK
WHICH CAN RESULT IN SERIOUS INJURY
OR DEATH. Before attempting installation or
service, ensure that all power to the device is
disconnected/turned off at the circuit breaker.
Connect only to a circuit protected by a residual
current device (RCD) with a rated residual
operating current not exceeding 30mA.
• Grounding is required. The unit should be
installed by a licensed electrician and should be
properly grounded and bonded.
• Install to permit access for servicing.
• Please read all cautions and safety instructions in
the Important Safety Instructions section. Before
attempting any electrical wiring, be sure to
read and follow safety instructions. Wiring
should only be attempted by a licensed
electrician.
Section 5. Extra Low Voltage
Wiring
All extra low voltage wiring should be run through
the rubber grommet fittings in the extra low voltage
compartment (right side of controller enclosure). Slice
through the rubber with a box cutter knife in order to
feed low voltage wires into the cabinet. See Figure 4.
IMPORTANT
Never run mains voltage and extra low voltage
in the same conduit.
(underside of controller enclosure)
Figure 4. Grommets for exta low voltage wiring
5.1 Wire the Temperature Sensors
Wire the temperature sensors on the 10-pin green
connector (see Figure 2. Wiring Diagram). The air
temperature sensor is factory-installed on the 10-pin
green connector (pins 7,8). The water temperature
sensor and necessary installation hardware is included.
5.1.1 Install the Water Temperature Sensor
1. Drill a hole for mounting the water temperature
sensor line in the pipe between the pump and the
lter(beforetheheater).
2. Install the O-ring on the sensor and insert the
sensor into the hole. Wrap and tighten metal clamp
around the pipe to secure sensor.
3. Feed the sensor wire through the black extra low
voltage wiring grommet.
4. Strip 5mm of insulation and separate the wires.
5. Connect sensor wires to pins 5, 6 of the 10-pin
green connector.
5.1.2 Install a Solar Sensor (if applicable)
If there is a solar heating system in the equipment
configuration, wire the solar heater temperature sensor
to the 10-pin green connector. The solar sensor should
be installed adjacent to the solar panel so it will sense
the same temperature as the solar panels. Do not install
in the pipe.
1. Feed the sensor wire through the black extra low
voltage wiring grommet.
2. Strip 5mm of insulation and separate the wires.
3. Connect sensor wires to pins 3, 4.
5.1.3 Install Additional Extra Low Voltage
Equipment (if applicable)
If there is additional extra low voltage equipment
installed, such as extra low voltage heating, wire
temperature sensor to to pins 1, 2 on the 10-pin green
connector (see Figure 2. Wiring Diagram).