Zodiac AquaLink TRi User manual

H0391100 REV B
INSTALLATION MANUAL
FOR YOUR SAFETY - This product must be installed and serviced by a licensed electrician in
accordance with AS/NZ 3000 - 2007 and any other local regulations. Before installing this product,
read and follow all warning notices and instructions that accompany this product. Failure to follow
warning notices and instructions may result in property damage, personal injury, or death. Improper
installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause serious
injury, property damage, or death.
WARNING
AquaLink®TRI®
Controller
Power Alert
!

Page 3
AquaLink®TRi®Controller | Installation Manual
Page 2 AquaLink®TRi®Controller | Installation Manual
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL HORSEPOWER
FILTER MODEL
CONTROL PANEL MODEL SERIAL NUMBER
NOTES:
EQUIPMENT INFORMATION RECORD

Page 3
AquaLink®TRi®Controller | Installation Manual
Page 2 AquaLink®TRi®Controller | Installation Manual
Table of Contents
Section 1. Important Safety Instructions....... 4
Section 2. System Overview ........................... 6
2.1 Package Contents.........................................................6
2.2 Electrical Specifications.................................................6
2.3 Materials and Tools ....................................................... 7
Section 3. Install Controller Box..................... 7
3.1 Mount the Controller Enclosure.....................................7
3.2 Mount the User Interface for Remote Access................ 8
Section 4. Mains Voltage Wiring..................... 8
4.1 Ground Fault Circuit Interrupter...................................10
Section 5. Extra Low Voltage Wiring ........... 10
5.1 Wire the Temperature Sensors....................................10
5.2 Install iAquaLink™(if applicable).................................. 11
5.3 Install Jandy Valve®Actuators (JVAs) (if applicable) ... 11
Section 6. System Setup, Programming
and Testing ................................... 12
6.1 Basic Navigation..........................................................12
6.2 Set the System Type ...................................................12
6.3 Set the Clock...............................................................12
6.4 Define Equipment ON/OFF Schedules ....................... 13
6.5 Test the AquaLink TRI .................................................13
Section 7. Install Settings............................... 14
7.1 Freeze Protect.............................................................15
7.2 Units ............................................................................16
7.3 Languages...................................................................16
7.4 Clear Memory..............................................................16
7.5 Pump...........................................................................16
7.6 Color Lights .................................................................17
7.7 Label Auxiliary Functions.............................................17
7.8 Temp Calibrate ............................................................18
7.9 Solar Priority (if applicable) ......................................... 18
7.10 Assign JVA ..................................................................18
7.11 Assign Hotkeys............................................................19
7.12 Ext. SWC Power..........................................................19
7.13 Diagnostics..................................................................19
Section 8. Service Mode................................ 20
Section 9. Pool/Spa System Menu
Flow Diagrams ............................. 21
9.1 Main Menu...................................................................21
9.2 Install Settings Menu...................................................22
Section 10. Pool Only System Menu
Flow Diagrams ............................. 23
10.1 Main Menu...................................................................23
10.2 Install Settings Menu...................................................24
Section 11. Glossaries..................................... 25
11.1 Glossary of Safety Delays and Lockouts..................... 25
11.2 Glossary of Alert Messages......................................... 25

Page 5
AquaLink®TRi®Controller | Installation Manual
Page 4 AquaLink®TRi®Controller | Installation Manual
Section 1. Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including
the following:
WARNING
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature
of the body reaches a level several degrees above the normal body temperature of 37°C (98.6°F) . The symptoms
of hyperthermia include dizziness, fainting, drowsiness, lethargy, and an increase in the internal temperature of
the body. The effects of hyperthermia include: 1) unawareness of impending danger; 2) failure to perceive heat;
3) failure to recognize the need to exit spa; 4) physical inability to exit spa; 5) fetal damage in pregnant women; 6)
unconsciousness resulting in a danger of drowning.
DANGER
To reduce the risk of severe injury or death, do not remove the suction fittings of your spa or hot tub. Never operate
a spa or hot tub if the suction fittings are broken or missing. Never replace a suction fitting with one rated less than
the flow rate marked on the equipment assembly.
WARNING
To Reduce the Risk of Injury -
a) The water in a spa should never exceed 40°C (104°F). Water temperatures should remain between 38°C
(100°F) and 40°C (104°F). The water in a spa should never exceed 40°C (104°F). Water temperatures
between 38°C (100°F) and 40°C (104°F) are considered safe for a healthy adult. Lower water temperatures
are recommended for young children and when spa use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of
pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 38°C (100°F). Before
entering a spa or hot tub, the user should measure the water temperature with an accurate thermometer since
the tolerance of water temperature-regulating devices varies.
d) The use of alcohol, drugs, or medication before or during spa or hot tub use may lead to unconsciousness with
the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system
problems, or diabetes should consult a physician before using a spa.
f) Persons using medication should consult a physician before using a spa or hot tub since some medication
may induce drowsines while other medication may affect heart rate, blood pressure, and circulation.
WARNING
Risk of electric shock - Install the controller at least 3.5 metres from the inside wall of the pool and/or hot tub
using non-metallic plumbing.
Children should not use spas or hot tubs without adult supervision.
Do not use spas or hot tubs unless all suction guards are installed to prevent body and hair entrapment.
People using medications and/or having an adverse medical history should consult a physician before using a spa
or hot tub.
WARNING
To avoid injury ensure that you use this control system to control only packaged pool/spa heaters which have built-
in operating and high limit controls to limit water temperature for pool/spa applications. This device should not be
relied upon as a safety limit control.

Page 5
AquaLink®TRi®Controller | Installation Manual
Page 4 AquaLink®TRi®Controller | Installation Manual
CAUTION
Power to the Aqualink TRI should be supplied by an isolating transformer or through a residual current device
(RCD) with a rated residual operating current not exceeding 30mA.
SAVE THESE INSTRUCTIONS
WARNING
People with infectious diseases should not use a spa or hot tub.
To avoid injury, exercise care when entering or exiting the spa or hot tub.
Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible
drowning.
Before entering a spa or hot tub, measure the water temperature with an accurate thermometer.
Do not use a spa or hot tub immediately following strenuous exercise.
Prolonged immersion in a spa or hot tub may be injurious to your health.
Do not permit any electric appliance (such as a light, telephone, radio, or television) within 3.5 metres of a spa or
hot tub.
The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.
Water temperature in excess of 38°C (100°F) may be hazardous to your health.
Attention Installer: Install to provide drainage of compartment for electrical components.
WARNING
A terminal bar marked "GROUND" is provided within the controller. To reduce the risk of electrical shock which can
cause serious injury or death, connect this terminal bar to the grounding terminal of your electric service or supply
panel with a continuous copper conductor having green insulation and one that is equivalent in size to the circuit
conductors supplying this equipment in accordance with AS/NZ 3000 - 2007. In addition, where required, bonding
should be extended in accordance with AS/NZ 3000 - 2007 to any metal ladders, water pipes, or other metal within
3.5 m of the pool/spa.

Page 7
AquaLink®TRi®Controller | Installation Manual
Page 6 AquaLink®TRi®Controller | Installation Manual
Section 2. System Overview
2.1 Package Contents
Package contents will vary depending on which
AquaLink TRI configuration you are installing.
AquaLink TRI PSi AquaLink TRI PS
• Four Function Controller with removeable
User Interface (UI)
• iAquaLink™
• Jandy Valve®Actuators (2)
• Water Temperature Sensor Kit
• Mounting Hardware
• Mounting Bracket
• Mounting Bracket for remotely installing UI
• Cover plate for UI housing
• Installation Manual/ Owner’s Manual
• Four Function Controller with removeable
User Interface (UI)
• Jandy Valve Actuators (2)
• Water Temperature Sensor Kit
• Mounting Hardware
• Mounting bracket
• Mounting Bracket for remotely installing UI
• Cover plate for UI housing
• Installation Manual/ Owner’s Manual
AquaLink TRI Pi AquaLink TRI P
• Four Function Controller with removeable
User Interface (UI)
• iAquaLink™
• Water Temperature Sensor Kit
• Mounting Hardware
• Mounting bracket
• Mounting Bracket for remotely installing UI
• Cover plate for UI housing
• Installation Manual/ Owner’s Manual
• Four Function Controller with removeable
User Interface (UI)
• Water Temperature Sensor Kit
• Mounting Hardware
• Mounting bracket
• Mounting Bracket for remotely installing UI
• Cover plate for UI housing
• Installation Manual/ Owner’s Manual
2.2 Electrical Specifications
Power Supply 240 VAC; 50 Hz; 2.5 A
Contact Rating Mains Voltage - 25 A;
3HP @ 240 VAC
1500 Watts Incandescent
Extra Low Voltage - Class 2,
1 A @ 24 VAC

Page 7
AquaLink®TRi®Controller | Installation Manual
Page 6 AquaLink®TRi®Controller | Installation Manual
2.3 Materials and Tools
Installation Materials Furnished
• Screw Set (includes Plastic Anchors)
• Metal Mounting Bracket
Tools Needed for Installation
• Power Drill
• 3/16” Drill Bit - Hammer Drill Bit (only necessary to drill into brick or concrete)
• Conduit Fittings
• Wire Nuts
• Wire Crimping Pliers
• Pencil or Marking Pen
• Flat Head Screwdriver
• Phillips Head Screwdriver
• Small Flathead or Slotted Screwdriver
Section 3. Install Controller Box
WARNING
FOR YOUR SAFETY: This product must be
serviced by a professional pool/spa service
technician as described on the front cover of this
manual. The procedures in this manual must be
followed exactly. Failure to follow warning notices
and instructions may result in property damage,
serious injury, or death. Improper installation and/or
operation will void the warranty.
When mounting the controller box in the equipment
pad, instructions must be followed exactly. Read
through the Important Safety Information section
completely before beginning installation and before
operating the equipment.
Before you begin installation, make sure you have the
necessary tools and a suitable location to install the
AquaLink TRI.
NOTE The controller should be located at or near the
equipment pad.
Locate the controller at least 3.5 metres or more away
from pool/spa and 1.5 metres off the ground. All
national, state, and local codes are applicable.
3.1 Mount the Controller Enclosure
1. Usingaatscrewdriver,rotatedoortumblersone
half turn counter-clockwise to unlock the front
cover of the controller.
2. Open the front cover door and remove the
mounting hardware kit taped on the inside of the
controller enclosure. Unpack the metal mounting
bracket.
3. Using the holes in the bracket as a guide, mark four
(4) dots on the surface where the controller will be
mounted. The four (4) mounting holes are 10 cm
(3-15/16″)apartcentertocenter.Usealevelto
check position before drilling to ensure accuracy.
NOTE Make sure to mark out the four (4) holes as
accurately as possible.
4. Drill four (4) holes in the mounting surface.
5. Pressthefour(4)plasticanchorsrmlyintoholes.
6. Screw the mounting bracket onto the mounting
surface with the four (4) screws provided.

Page 9
AquaLink®TRi®Controller | Installation Manual
Page 8 AquaLink®TRi®Controller | Installation Manual
CAUTION
Make sure to perform the following step BEFORE
mounting the enclosure onto the mounting bracket,
otherwise, damage to the threaded hole of the
mounting bracket may occur.
7. Open the front cover of the controller and locate
the fastening hole under the ground bar. Use a drill
size 3/16” to drill through the plastic enclosure.
This is the fastening hole aligned with the threaded
hole of mounting bracket.
8. Line up the slot in the controller enclosure with
the guide in the mounting bracket and hook on to
mount.
9. Secure the controller enclosure to the mounting
bracketwiththesinglenethreadPhillipsscrew
provided.
Mounting
Bracket
Anchors (4)
Screw
Screws (4)
Controller
Drill a 3/16” hole before
mounting onto the bracket
Figure 1. Mounting the Controller Enclosure
3.2 Mount the User Interface for Remote
Access
For ease of use, you may remove the user interface (UI)
from the controller enclosure and install it in a location
away from the equipment pad.
NOTE: To set up the UI this way, use the provided
5 metre length of cable. If a longer length is
required this can be purchased from most
leading electronics retailers (common phone
cable with RJ11 jacks should be used).
WARNING
When installing the UI for remote use, UI must be
located where a service professional may access it
and the blanking panel (provided) must be installed
in place on the controller door.
1. Using the holes in the metal bracket as a guide,
drill two (2) holes on the surface where the UI will
be mounted.
2. Screw the bracket to the surface using two (2)
screws.
3. Remove the UI from the front of the controller
enclosure and attach magnetically to the mounting
plate.
4. Use the plastic face plate provided to cover the UI
housing when UI is removed. Attach face plate to
enclosure door with two screws retained from UI
removal.
Section 4. Mains Voltage Wiring
WARNING
Potentially high voltages in the AquaLink TRI
controller can create dangerous electrical hazards,
possibly causing death, serious injury or property
damage. Turn off power at the main circuit feeding
the AquaLink TRI controller to disconnect the power
center from the system.
WARNING
Zodiac Group Australia PTY LTD advises that
any procedure requiring potential contact with live
electrical wiring and/or parts other than cords and
plugs connected to electrical outlets, be completed
by a licensed electrical contractor qualified in pool
equipment as described on the front of this manual.
Failure to follow warning notices and instructions
may result in property damage, serious injury, or
death.
All mains voltage wiring must be done by a licensed
electrical contractor.
NOTE: See Figure 2. AquaLink TRI Electrical Wiring
Diagram for specic wire locations and
connections.

Page 9
AquaLink®TRi®Controller | Installation Manual
Page 8 AquaLink®TRi®Controller | Installation Manual
Figure 2. AquaLink TRI Controller Electrical Wiring Diagram
Ground wire for main
MAINS VOLTAGE
EXTRA LOW VOLTAGE
240VAC
24VAC
1 2 3 4 5 6 7 8 9 10
AQUALINK TRi
POWER
TRANSFORMER
BLU
BRW
AUX 1 AUX 2
GROUND BAR
FILTER AUX 3
PUMP
Input Power:
240 VAC,
1.67A,
50 Hz
Water Temp Sensor
Air Temp Sensor
Solar Temp Sensor
F. Pump
Aux 1
Aux 2
Aux 3
Relay Sockets
(24 VDC output)
JVA Sockets
(24 VAC output)
Intake
Return
Solar
Not Used
Low Voltage
Heater
Green Terminal Bar
RS485 Network
(Red Terminal Bar)
RJ Connector
(Black Modular
Connector)
24 VAC Power Plug from
transformer connects into a
3-pin terminal on the back
Power Controller Board.
Power Controller Board
iAQUALINK™ J-BOX
Select
Back
Power Alert
ZODIAC
12:40PM
Pool Mode O
Pool Heater 80°F
Spa Mode O
Spa Heater O
Settings >
Devices >
Service Mode >
®
AQUALINK TRI
USER INTERFACE

Page 11
AquaLink®TRi®Controller | Installation Manual
Page 10 AquaLink®TRi®Controller | Installation Manual
4.1 Ground Fault Circuit Interrupter
WARNING
When using electrical products, basic precautions
should always be followed, including the following:
• DANGER: RISK OF ELECTRIC SHOCK
WHICH CAN RESULT IN SERIOUS INJURY
OR DEATH. Before attempting installation or
service, ensure that all power to the device is
disconnected/turned off at the circuit breaker.
Connect only to a circuit protected by a residual
current device (RCD) with a rated residual
operating current not exceeding 30mA.
• Grounding is required. The unit should be
installed by a licensed electrician and should be
properly grounded and bonded.
• Install to permit access for servicing.
• Please read all cautions and safety instructions in
the Important Safety Instructions section. Before
attempting any electrical wiring, be sure to
read and follow safety instructions. Wiring
should only be attempted by a licensed
electrician.
Section 5. Extra Low Voltage
Wiring
All extra low voltage wiring should be run through
the rubber grommet fittings in the extra low voltage
compartment (right side of controller enclosure). Slice
through the rubber with a box cutter knife in order to
feed low voltage wires into the cabinet. See Figure 4.
IMPORTANT
Never run mains voltage and extra low voltage
in the same conduit.
(underside of controller enclosure)
Figure 4. Grommets for exta low voltage wiring
5.1 Wire the Temperature Sensors
Wire the temperature sensors on the 10-pin green
connector (see Figure 2. Wiring Diagram). The air
temperature sensor is factory-installed on the 10-pin
green connector (pins 7,8). The water temperature
sensor and necessary installation hardware is included.
5.1.1 Install the Water Temperature Sensor
1. Drill a hole for mounting the water temperature
sensor line in the pipe between the pump and the
lter(beforetheheater).
2. Install the O-ring on the sensor and insert the
sensor into the hole. Wrap and tighten metal clamp
around the pipe to secure sensor.
3. Feed the sensor wire through the black extra low
voltage wiring grommet.
4. Strip 5mm of insulation and separate the wires.
5. Connect sensor wires to pins 5, 6 of the 10-pin
green connector.
5.1.2 Install a Solar Sensor (if applicable)
If there is a solar heating system in the equipment
configuration, wire the solar heater temperature sensor
to the 10-pin green connector. The solar sensor should
be installed adjacent to the solar panel so it will sense
the same temperature as the solar panels. Do not install
in the pipe.
1. Feed the sensor wire through the black extra low
voltage wiring grommet.
2. Strip 5mm of insulation and separate the wires.
3. Connect sensor wires to pins 3, 4.
5.1.3 Install Additional Extra Low Voltage
Equipment (if applicable)
If there is additional extra low voltage equipment
installed, such as extra low voltage heating, wire
temperature sensor to to pins 1, 2 on the 10-pin green
connector (see Figure 2. Wiring Diagram).

Page 11
AquaLink®TRi®Controller | Installation Manual
Page 10 AquaLink®TRi®Controller | Installation Manual
5.2 Install iAquaLink™(if applicable)
iAquaLink is included in PSi and Pi kits only.
NOTE: For complete intructions and safety information,
refer to the iAquaLink Quick Start Guide
(included in the iAquaLink packaging), or the
full iAquaLink manual (found online at
www. zodiac.com.au).
5.2.1 Mount the iAquaLink Device
Mount the iAquaLink at least 2 metres off the ground
and at least 2.5 metres from any motors, such as a
blower.
1. Mark and drill two (2) holes in the selected surface.
2. Presstwo(2)plasticanchorsrmlyintoholes.
3. Screw the device onto the mounting surface with
the two (2) screws provided.
5.2.2 Wiring in RS485 Communication
Devices
Compatible RS485 devices (e.g., Zodiac TRi saltwater
chlorinator,ZodiacePumpvariablespeedlterpump,
or iAquaLink) must be connected through the RS485
red pin terminal bar. For further installation instructions
consulttheownersmanualofthespecicproduct.
Connection of Zodiac TRi–
Using 4 core cable (WCABLE) wire a suitable length
into the TRi Green terminal bar onto the appropriate
contacts as follows,
1-Green wire (0V) to ‘0V’ terminal on the TRi
2-Red wire to the (+V) ‘POS’ terminal on the TRi
3-Yellow/White (B) wire to ‘B’ terminal on TRi
4-Black wire (A) to ‘A’ terminal on TRi
Once these connections are in place, follow the wiring
instructions to connect to the AquaLink TRi.
Connection of Zodiac ePump–
Remove the rear motor cover and ensure all 4 dip
switches are in the OFF position. The ePump already
hasa4corecablettedtothepump.Howeveryou
will need to cut off the red 4 pin bar from the cable and
follow the wiring instructions below to connect to the
AquaLink TRi.
Connection of iAquaLink–
Follow the wiring instructions to connect to the
AquaLink TRi.
Wiring Instructions for connecting to AquaLink TRi–
Steps 1-3 below show connecting devices into the
RS485 port in AquaLink TRi.
1. Feed wire through the black extra low voltage
wiring grommet.
2. Strip1/4″ofinsulationandseparatethewires.
3. Connect four (4) separate wires to each terminal
(Figure 5).
3 Yellow
1 Red
2 Black
4 Green
Red 4-Pin Terminal Bar
Figure 5. RS-485 Wiring
NOTE: Wire only two (2) devices (e.g, the iAquaLink™
and one additional device) to the RS-485
connector. If you have more than one additional
device in your equipment conguration, use a
multiplex board. This can be ordered from your
Zodiac Stockist (part number W6584).
5.3 Install Jandy Valve®Actuators (JVAs)
(if applicable)
You may wire up to three JVAs on the AquaLink TRI.
Two (2) JVAs are included in PSi and PS (Pool/Spa
combo) kits. An additional JVA may be required on a
pool/spa combination configuration to control a water
feature or solar heater, for example.
NOTE: Read and follow complete installation intructions
and safety information in the Jandy Valve
Actuator owner’s manual (included in the JVA
packaging).
1. Install intake JVA and return JVA on equipment
lines according to installation instructions in the
owner’s manual.
2. Feed intake JVA wire through the black extra low
voltage wiring grommet.
3. Plug JVAs in as shown in Figure 2. Wiring
Diagram.
4. Feed return JVA wire through the black extra low
voltage wiring grommet.
5. Plug return JVA connection into the center socket.

Page 13
AquaLink®TRi®Controller | Installation Manual
Page 12 AquaLink®TRi®Controller | Installation Manual
Section 6. System Setup,
Programming and Testing
All system programming and installation setup is
performed through the AquaLink TRI user interface UI
(even when connected to iAquaLink which only allows
for basic programming and functionality).
NOTE: For a complete list of all menu commands and
functions, refer to the Owner’s Manual.
Select
Back
More
Back Button
Power Light
Select Button
Alert Light
Power Button
Menu Screen
Up/Down (Scroll)
Arrows
Power Alert
Zodiac
12:40PM
Pool Mode O
Pool Heater 74°F
Spa Mode O
Spa Heater O
Settings >
Devices >
Service Mode >
®
Figure 6. User Interface
6.1 Basic Navigation
Use the following buttons on the user interface to access
and select all menus and commands:
More
®
On/Off
Turn user interface power on/off.
Up/Down
Scroll up/down within current menu to
More
®
highlight a specific menu command.
More
®
Back
Go back to previous menu. To return to Main
menu, press Back button repeatedly.
More
®
Select
Select current highlighted menu command.
Display the next menu or activate the
selected function.
6.2 Set the System Type
MAIN > SETTINGS > SYSTEM TYPE MENU
NOTE This option is only available on AquaLink TRI
PS and PSi congurations.
Define the system type (Pool/Spa or Pool only) through
the Service Menu. The System Type Menu is hidden.
• HighlightSETTINGS,thenpressandholdSelect
for ten (10) seconds.
Zodiac
12:40PM
Pool Mode On
Pool Heater 26°C
Aux1 O
Aux2 O
Settings >
Devices >
Settings
Clock
Schedules
Zodiac
12:40PM
Pool Mode On
Pool Heater 26°C
Aux1 O
Aux2 O
Settings >
Devices >
Settings
Clock
Schedules
SYSTEM TYPE
Pool Only
Pool/Spa Combo
SERVICE MENU
Service Mode >
System Type >
6.3 Set the Clock
MAIN > SETTINGS > CLOCK
Set the current day of the week and time. This setting is
the basis for defining schedules for the filter pump.
SET CLOCK
Monday
1:04AM
Settings
Clock
Schedule
SET CLOCK
Monday
1:04AM
Settings
Clock
Schedule
1. HighlightCLOCKandpressSelecttwice.
Currentprogrammeddayashes.
2. Scroll up/down to display desired Day, then Select.
3. Scroll down to display current programmed time.
PressSelect.Currentprogrammedhourashes.
4. Scroll up/down to display desired hour, then Select.
Currentprogrammedminutesash.
5. Scroll up/down to display desired minutes, then
Select.

Page 13
AquaLink®TRi®Controller | Installation Manual
Page 12 AquaLink®TRi®Controller | Installation Manual
6.4 Define Equipment ON/OFF Schedules
MAIN > SETTINGS > SCHEDULES
DefineautomaticONandOFFtimesforequipment.
You may set different schedules for any single day,
weekdays, weekends, or all days for any of the
following equipment:
• Filter Pump
• Variable Speed Pump Preset (if applicable)
• PoolHeater
• SpaHeater(ifapplicable)
• SolarHeater(ifapplicable)
• Aux1, Aux2, and Aux3 (as applicable)
Set a maximum of ten programs per piece of equipment.
6.4.1 Define Filter Pump Schedule
MAIN > SETTINGS > SCHEDULES > FILTER PUMP
NOTE: The procedure to dene or change ON and OFF
times for all additional equipment is identical to
dening Filter Pump schedule.
SCHEDULE
Filter Pump
No programs
entered
MORE
SCHEDULES
NEW >
Filter Pump >
Spa >
Pool Heat >
Spa Heat >
Solar Heat >
SCHEDULE
Filter Pump
No programs
entered
MORE
SCHEDULES
NEW >
Filter Pump >
Spa >
Pool Heat >
Spa Heat >
Solar Heat >
1. HighlightFILTERPUMPandpressSelect.
Noprogramiscurrentlyentered.
2. HighlightNEWandpressSelect.
CurrentONtimeisdisplayed.
3. Use Up/Down arrow keys to program hours and
minutesfordesiredONtime.
4. Repeat the steps to program hour and minutes for
OFF time.
5. Repeat the steps to program desired DAYS.
Default setting is ALL DAYS.
Filter Pump
NEW SCHEDULE
ON: 12:00AM
OFF: 12:00PM
DAYS: OFF
Filter Pump
NEW SCHEDULE
ON: 10:30AM
OFF: 7:45PM
DAYS: Weekday
SAVE
Filter Pump
NEW SCHEDULE
ON: 12:00AM
OFF: 12:00PM
DAYS: OFF
Filter Pump
NEW SCHEDULE
ON: 10:30AM
OFF: 7:45PM
DAYS: Weekday
SAVE
6. Scroll down to SAVE. Press Select.
6.5 Test the AquaLink TRI
Perform a basic installation test to make sure the
controller turns on the filter pump, the pool heater,
and spa pump and spa heater (if applicable). Test the
controller installation using the Manual Control menu to
turnspecificequipmentON/OFFmanually.
6.5.1 Test Filter Pump ON/OFF
MAIN > DEVICES > FILTER PUMP
Zodiac
12:40PM
Pool Mode On
Pool Heater 80°F
Spa Mode >
Spa Heater >
Aux1 O
Aux2 O
Settings >
Devices >
Devices
Filter Pump O
Spa Pump O
Pool Heat O
Spa Heat O
Solar Heat O
Zodiac
12:40PM
Pool Mode On
Pool Heater 26°C
Spa Mode O
Spa Heater O
Settings >
Devices >
Service Mode >
Devices
Filter Pump On
Spa Pump O
Pool Heat O
Spa heat O
Solar Heat O
More
• HighlightFILTERPUMPandpressSelecttoturn
thelterpumpON.
After a couple of minutes, you should hear the
lterpumpgoon.
6.5.2 Test Spa Pump ON/OFF
(if applicable)
MAIN > DEVICES > SPA PUMP
Zodiac
12:40PM
Pool Mode On
Pool Heater 26°C
Spa Mode O
Spa Heater O
Settings >
Devices >
Service Mode >
Devices
Filter Pump O
Spa Pump On
Pool Heat O
Spa heat O
Solar Heat O
More
Zodiac
12:40PM
Pool Mode On
Pool Heater 26°C
Spa Mode O
Spa Heater O
Settings >
Devices >
Service Mode >
Devices
Filter Pump O
Spa Pump On
Pool Heat O
Spa heat O
Solar Heat O
More
• HighlightSPAPUMPandpressSelecttoturnthe
spapumpON.
After a couple of minutes, you should hear the spa
pump go on.

Page 15
AquaLink®TRi®Controller | Installation Manual
Page 14 AquaLink®TRi®Controller | Installation Manual
6.5.3 Test Pool Heater ON/OFF
MAIN > DEVICES > POOL HEATER
1. HighlightPOOLHEATERandpressSelect.
2. Scroll up/down to set temperature then press
Select. After a couple of minutes, you should hear
the pool heater go on.
Zodiac
12:40PM
Pool Mode O
Pool Heater 26°F
Spa Mode O
Spa Heater O
Settings >
Devices >
Zodiac
12:40PM
Pool Mode O
Pool Heater O
Spa Mode O
Spa Heater O
Settings >
Devices >
Filter Pump
Aux1
Aux2
POOL HEAT
Enabled
Set to: 28°F
Devices
Filter Pump O
Spa O
Pool Heat O
Spa Heat O
Solar Heat O
More
Pool Heat
Enabled
Set to: 80°F
6.5.4 Test Spa Heater ON/OFF
(if applicable)
NOTE: To test the spa heater installation, rst turn on
the auxiliary JVA associated with the spa (see
Section 7.10 Assign JVA) and wait 35 seconds
before turning on the spa heater through the UI.
MAIN > DEVICES > SPA HEATER
Zodiac
12:40PM
Pool Mode On
Pool Heater 26°C
Spa Mode O
Spa Heater O
AUX1 >
AUX2 >
Settings >
Devices >
Devices
Filter Pump O
Spa Pump O
Pool Heat O
Spa Heat On
Solar Heat O
More
Manual Control
Filter Pump O
Spa O
Pool Heat O
Spa Heat O
Solar Heat O
More
Spa Heat
Enabled
Set to: 38°C
1. HighlightSPAHEATERandpressSelect.
2. Scroll up/down to set temperature then press
Select. After a couple of minutes, you should hear
the spa heater go on.
Section 7. Install Settings
Install Settings is a hidden menu, mostly used for setup
and reference purposes.
Settings available through this menu:
• Freeze Protect
Automatically turn specific equipment on to protect
against freezing temperatures.
• Units
Change units of measurement displayed on the User
Interface (temperature and time format).
• Language
Change language displayed on the User Interface.
• Clear Memory
Clear all programmed data in the controller for all
equipment.
• Pump
Assign a one-speed, two-speed pump or variable-speed
pump to the controller.
• Color Lights
Only available if specific lights are installed in your
configuration.
• Label Aux
Assign custom labels to auxiliary equipment, such as an
air blower, cleaner, solar pump, etc.
• Temp Calibrate
Adjust temperature displayed on the User Interface up or
down by four (4) degrees.
• Solar Priority
Only available if solar heating is installed in your system.
• Assign JVA
Assign Jandy Valve®Actuators (JVAs) to specific AUX
relays, as intake or return in Pool Only mode.
• Ext. SWC Power
Only available if a compatible salt water chlorinator
(SWC) is installed in your configurations.
• Assign Hotkeys
Only available if AquaPalm™is installed with your
configuration.
• Diagnostics
Display software revision information and alerts for
troubleshooting purposes.

Page 15
AquaLink®TRi®Controller | Installation Manual
Page 14 AquaLink®TRi®Controller | Installation Manual
To access the Install Settings Menu:
• Press and hold Up/Down arrow keys at the same
time for about 5 seconds.
Zodiac
12:40PM
Pool Mode On
Pool Heater 26°C
Aux1 O
Aux2 O
Settings >
Devices >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
INSTALL SETTINGS
Color Light >
Label Aux >
Temp Calibrate >
Solar Priority >
Assign JVA >
Assign Hotkeys >
INSTALL SETTINGS
Diagnostics >
Zodiac
12:40PM
Pool Mode On
Pool Heater 26°C
Aux1 O
Aux2 O
Settings >
Devices >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
INSTALL SETTINGS
Color Light >
Label Aux >
Temp Calibrate >
Solar Priority >
Assign JVA >
Assign Hotkeys >
INSTALL SETTINGS
Diagnostics >
7.1 Freeze Protect
NOTE By factory default the lter pump circuit is freeze
protected. During freeze protection, the lter
pump cannot be turned off.
IMPORTANT
Freeze protection is intended to protect equipment
and plumbing for short periods of freezing only.
It does this by activating the filtration pump and
circulating the water to prevent freeze inside
equipment or plumbing. Freeze protection does
not guarantee that equipment will not be damaged
by extended periods of freezing temperatures or
power outages. In these conditions, the pool and
spa should be shut down completely (e.g. drained of
water and closed for the winter) until warmer weather
exists.
CAUTION
Activating the spa during freezing conditions will
override freeze protection. This means that if you are
using your spa when freezing conditions exist, freeze
protection will not circulate water to non-spa related
equipment that you may have freeze protected
(e.g. pool cleaner, booster pump.) Under these
circumstances, the potential for equipment damage
may exist.
Set Temperature:
INSTALL SETTINGS > FREEZE PROTECT >
SET TEMP
Set outside temperature at which freeze protect function
is activated. Activation temperature can be adjusted
between 2°C and 5°C Default freeze protection
activation temperature is 3ºC. The freeze protected
equipment will turn off when the temperature increases
1° C above the activation temperature.
MORE
INSTALL SETTINGS
Freeze Protect >
Units
>
Language >
Clear Memory >
Pump
>
FREEZE PROTECT
Set Temp >
Equipment >
MORE
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
FREEZE PROTECT
Set Temp >
Equipment >
FREEZE PROTECT
TEMPERATURE
Temp: 3˚C
MORE
FREEZE PROTECT
Set Temp >
Equipment >
Select Equipment:
INSTALL SETTINGS > FREEZE PROTECT >
EqUIPMENT
Assign freeze protection to a selected piece of
equipment.
FREEZE PROTECT
EQUIPMENT
Filter Pump
Aux1
Aux2
Aux3
FREEZE PROTECT
Set Temp >
Equipment >
FREEZE PROTECT
EQUIPMENT
Filter Pump
Aux1
Aux2
Aux3
FREEZE PROTECT
Set Temp >
Equipment >

Page 17
AquaLink®TRi®Controller | Installation Manual
Page 16 AquaLink®TRi®Controller | Installation Manual
7.2 Units
INSTALL SETTINGS>UNITS
Change the temperature units (Fahrenheit - Celcius) and
time format (12-hour AM/PM or 24-hour clock).
SET UNITS
˚F/˚C
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
AM/PM 24H
SET UNITS
˚F/˚C
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
AM/PM 24H
7.3 Languages
MAIN/STATUS>MENU>SYSTEM SETUP>LANGUAGE
Change the language displayed on the user interface.
Languages available are:
• English •Francais
• Espanol •Italiano
• Deutsch •Portuguese
• Nederlands •Afrikaans
SET LANGUAGE
English
Français
Espanol
Italiano
Deutsch
More
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
SET LANGUAGE
English
Français
Espanol
Italiano
Deutsch
More
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
7.4 Clear Memory
INSTALL SETTINGS>CLEAR MEMORY
Clear all stored values (e.g., auxiliary labels, programs,
remote settings, and thermostat settings) from the
AquaLink TRI memory. All settings will be reset to
default factory settings. Time and date is not cleared.
CLEAR MEMORY
Clear?
No
Yes
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
CLEAR MEMORY
Clear?
Are you sure you
want to clear?
Cancel
Yes
CLEAR MEMORY
Clear?
No
Yes
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
CLEAR MEMORY
Clear?
Are you sure you
want to clear?
Cancel
Yes
CLEAR MEMORY
Clear?
No
Yes
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
CLEAR MEMORY
Clear?
Are you sure you
want to clear?
Cancel
Yes
• The system asks you to verify you are sure you
want to clear memory.
• There is a 15-second delay and *MEMORY
CLEARED* message is displayed.
7.5 Pump
Assign the pump type currently installed in your system,
either one or two-speed, or variable speed.
Select 1-Speed or 2-Speed Pump:
INSTALL SETTINGS > PUMP > 1-SPEED / 2-SPEED
Assign either one-speed or two-speed pump On/Off.
SET PUMP TYPE
1-Speed >
2-Speed >
VSP
VSP Setup >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
VSP SETUP
Model >
Assign Speeds >
Prime
Min/Max >
Freeze >
VSP SETUP
Model >
Assign Speeds >
Prime
Min/Max >
Freeze >
SET PUMP TYPE
1-Speed >
2-Speed >
VSP
VSP Setup >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
SET PUMP TYPE
1-Speed >
2-Speed >
VSP
VSP Setup >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
VSP SETUP
Model >
Assign Speeds >
Prime
Min/Max >
Freeze >
VSP SETUP
Model >
Assign Speeds >
Prime
Min/Max >
Freeze >
SET PUMP TYPE
1-Speed >
2-Speed >
VSP
VSP Setup >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
• A check mark next to the pump name indicates it is
currently selected.

Page 17
AquaLink®TRi®Controller | Installation Manual
Page 16 AquaLink®TRi®Controller | Installation Manual
Select Variable Speed Pump (VSP):
INSTALL SETTINGS > PUMP > VSP > VSP SETUP
Select the variable speed pump type installed and
select the various pump speed settings and minimum/
maximum speed limits.
SET PUMP TYPE
1-Speed >
2-Speed >
VSP
VSP Setup >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
VSP SETUP
Model >
Assign Speeds >
Prime
Min/Max >
Freeze >
VSP SETUP
Model >
Assign Speeds >
Prime
Min/Max >
Freeze >
SET PUMP TYPE
1-Speed >
2-Speed >
VSP
VSP Setup >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
SET PUMP TYPE
1-Speed >
2-Speed >
VSP
VSP Setup >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
VSP SETUP
Model >
Assign Speeds >
Prime
Min/Max >
Freeze >
VSP SETUP
Model >
Assign Speeds >
Prime
Min/Max >
Freeze >
SET PUMP TYPE
1-Speed >
2-Speed >
VSP
VSP Setup >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
SET PUMP TYPE
1-Speed >
2-Speed >
VSP
VSP Setup >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
VSP SETUP
Model >
Assign Speeds >
Prime
Min/Max >
Freeze >
VSP SETUP
Model >
Assign Speeds >
Prime
Min/Max >
Freeze >
SET PUMP TYPE
1-Speed >
2-Speed >
VSP
VSP Setup >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory >
Pump >
More
• For any Jandy brand pump, select Jandy/Zodiac.
• For other branded variable speed pumps, check the
manufacturer’s details for compatibility.
7.6 Color Lights
INSTALL SETTINGS > COLOR LIGHTS
NOTE You will only see this option if colored lights are
installed in your system.
Select type of light installed (e.g., Jandy®ColorsTM or
Jandy®LED Light ) and assign the light to an available
auxiliary relay. Please noteforAustraliaPacicregion
all Jandy and/or Zodiac lights use the same setting.
Select Light Type:
SELECT LIGHT
Jandy Color
Jandy LED
More
INSTALL SETTINGS
Color Lights >
Label Aux >
Temp Calibrate >
Solar Priority >
Assign JVA >
>
Assign Selected Light to an Auxiliary:
SELECT LIGHT
Jandy Color
Jandy LED
ASSIGN TO AUX
Jandy Color
Aux1 JC
Aux2
Aux3
SELECT LIGHT
Jandy Color
Jandy LED
ASSIGN TO AUX
Jandy Color
Aux1 JC
Aux2
Aux3
• JC is displayed next to AUX if a Jandy Colors light
has been assigned.
• JL is displayed next to AUX if a Jandy LED Light
has been assigned.
• Press Select button with JC or JL highlighted to
toggle control by the auxiliary on or off.
7.7 Label Auxiliary Functions
INSTALL SETTINGS>LABEL AUX
Assign labels to auxiliary equipment to display text in
the user interface instead of AUX 1, 2, or 3.
LABEL AUX
Aux1 >
Aux2 >
Aux3 >
Label = Aux2
<Default>
Aerator
Air Blower
Backwash
Chlorinator
More
Label = Aux2
Swim Jet
Valve(s)
Wtr Feature
Waterfalls
Whirlpool
More
More
INSTALL SETTINGS
Color Lights >
Label Aux >
Temp Calibrate >
Solar Priority >
Assign JVA >
>
LABEL AUX
Aux1 >
Aux2 >
Aux3 >
Label = Aux2
<Default>
Aerator
Air Blower
Backwash
Chlorinator
More
Label = Aux2
Swim Jet
Valve(s)
Wtr Feature
Waterfalls
Whirlpool
More
More
INSTALL SETTINGS
Color Lights >
Label Aux >
Temp Calibrate >
Solar Priority >
Assign JVA >
>
LABEL AUX
Aux1 >
Aux2 >
Aux3 >
Label = Aux2
<Default>
Aerator
Air Blower
Backwash
Chlorinator
More
Label = Aux2
Swim Jet
Valve(s)
Wtr Feature
Waterfalls
Whirlpool
More
More
INSTALL SETTINGS
Color Lights >
Label Aux >
Temp Calibrate >
Solar Priority >
Assign JVA >
>
LABEL AUX
Aux1 >
Aux2 >
Aux3 >
Label = Aux2
<Default>
Aerator
Air Blower
Backwash
Chlorinator
More
Label = Aux2
Swim Jet
Valve(s)
Wtr Feature
Waterfalls
Whirlpool
More
More
INSTALL SETTINGS
Color Lights >
Label Aux >
Temp Calibrate >
Solar Priority >
Assign JVA >
>
A-Z
• Choose from labels listed A-Z on each screen.
NOTE “SPILLOVER” assigns AUX to invoke Spillover
Mode only in AquaLink TRI PS or PSi
congurations.

Page 19
AquaLink®TRi®Controller | Installation Manual
Page 18 AquaLink®TRi®Controller | Installation Manual
7.8 Temp Calibrate
INSTALL SETTINGS>TEMP CALIBRATE
Adjust temperature displayed on the AquaLink TRI up
or down by 2 degrees.
NOTE If the temperature is off by more than two
(2) degrees, contact your local service
representative.
TEMPERATURE
CALIBRATE
Water: 26°C
More
SYSTEM SETUP
Label Aux
>
Temp Calibrate >
Solar Priority >
Assign JVA
>
Color Light
>
TEMPERATURE
CALIBRATE
Water: 26°C
More
SYSTEM SETUP
Label Aux >
Temp Calibrate >
Solar Priority >
Assign JVA >
Color Light >
• Use Up/Down arrows to set new temperature value.
7.9 Solar Priority (if applicable)
INSTALL SETTINGS>SOLAR PRIORITY
NOTE: You will only see this option if solar heating is
installed in your system.
Enable the system to use solar heat first, when available.
If solar heat is no longer available, the system will
automatically switch to the alternate heat source.
SOLAR PRIORITY
Enable
Disable
More
INSTALL SETTINGS
Color Lights >
Label Aux >
Temp Calibrate >
Solar Priority >
Assign JVA >
>
• When solar and heater are enabled the solar will
heat the water until either the thermostat setting has
been reached or solar heat is no longer available.
• If the solar panel is not hot enough, solar heat will
shut off and the other heat source (usually gas
heater) will take over to bring the water up to the
thermostat setting.
7.10 Assign JVA
INSTALL SETTINGS>ASSIGN JVA
NOTE: If the system is a pool/spa combination, without
solar, only the solar JVA is assignable. If the
system is a pool or spa only system, without
solar, all three JVAs are assignable. The
example shown is for a pool or spa only system
without solar.
Allow Jandy®Valve Actuators (JVAs) to be assigned
to any auxiliary on the AquaLink TRI controller, so
that when you select this auxiliary, the valve turns.
Assigning JVAs lets the pool owner control certain
features like diverting water to a waterfall or bank of
spa jets. Multiple JVAs can be assigned to one auxiliary
without extra hardware.
ASSIGN JVA
Intake Free
Return Free
Solar Free
ASSIGN JVA
Intake/Return/Solar
None
Aux1
Aux2
Aux3
More
INSTALL SETTINGS
Color Lights >
Label Aux >
Temp Calibrate >
Solar Priority >
Assign JVA >
>
ASSIGN JVA
Intake Free
Return Free
Solar Free
ASSIGN JVA
Intake/Return/Solar
None
Aux1
Aux2
Aux3
More
INSTALL SETTINGS
Color Lights >
Label Aux >
Temp Calibrate >
Solar Priority >
Assign JVA >
>

Page 19
AquaLink®TRi®Controller | Installation Manual
Page 18 AquaLink®TRi®Controller | Installation Manual
7.11 Assign Hotkeys
INSTALL SETTINGS>ASSIGN HOTKEYS
NOTE: You will only see this option if the AquaPalm™
is installed in your system and is turned on.
Assign buttons 1 and 2 on the AquaPalm handheld
remote to any piece of equipment connected to a circuit
or relay for immediate and dedicated control of that
equipment.
Assign Hotkeys
1 Aux1
2 Aux2
INSTALL SETTINGS
Assign Hotkeys >
Hotkey 1
Aux1
Aux2
Aux3
Filter Pump
Pool Heat
Solar Heat
Assign Hotkeys
1 Aux1
2 Aux2
INSTALL SETTINGS
Assign Hotkeys >
Hotkey 1
Aux1
Aux2
Aux3
Filter Pump
Pool Heat
Solar Heat
Assign Hotkeys
1 Aux1
2 Aux2
INSTALL SETTINGS
Assign Hotkeys >
Hotkey 1
Aux1
Aux2
Aux3
Filter Pump
Pool Heat
Solar Heat
7.12 Ext. SWC Power
INSTALL SETTINGS>EXT. SWC POWER
NOTE: You will only see this menu if SWC is connected
to your system.
Route saltwater chlorinator system (SWC) power
through one of the auxiliary relays.
EXT. SWC POWER
None
Aux 1
Aux 2
Aux 3
Filter Pump
More
INSTALL SETTINGS
Ext. SWC Power >
Diagnostics >
EXT. SWC POWER
None
Aux 1
Aux 2
Aux 3
Filter Pump
More
INSTALL SETTINGS
Ext. SWC Power >
Diagnostics >
7.13 Diagnostics
INSTALL SETTINGS>DIAGNOSTICS
For troubleshooting purposes, view diagnostic
information relating to current firmware revisions,
system alerts or error messages, and status of devices
connected to the RS-485 controller.
View Revision Number:
INSTALL SETTINGS>DIAGNOSTICS>REVISIONS
View your system firmware revision number for
troubleshooting.
DIAGNOSTICS
Revisions >
Alerts >
RS-485 Devices >
More
INSTALL SETTINGS
Diagnostics >
RS-485 DEVICES
AQP: 100%
FFC: 100%
iAL: 100%
SWC: 100%
VSP: 100%
REVISIONS
UI: 1.3
Bootloader: 0.26
SWC:
FFC: 0.18
iAquaLink: 2.1.4
View Alert Messages
INSTALL SETTINGS>DIAGNOSTICS>ALERTS
View alerts or error messages. See Section 10.
Glossaries for a complete list and explanation of all
system messages.
Select
Back Select
Back
CURRENT ALERTS
[BLANK UNTIL AN
ALERT OCURS]
More
DIAGNOSTICS
Revisions >
Alerts >
DIAGNOSTICS
Revisions >
Alerts >
RS-485 Devices >
• Screen is blank if the controller has no errors to
report.
View RS-485 Device Status:
INSTALL SETTINGS>DIAGNOSTICS>RS-485 DEVICES
View status of devices connected to the RS-485
controller. Depending on your equipment configuration,
any combination of the following equipment may be
displayed:
• FFC - AquaLink TRI Controller
• iAL - iAquaLink
• SWC - Salt Water Chlorinator
• VSP - Variable Speed Pump

Page 21
AquaLink®TRi®Controller | Installation Manual
Page 20 AquaLink®TRi®Controller | Installation Manual Page 21
AquaLink®TRi®Controller | Installation Manual
Page 20 AquaLink®TRi®Controller | Installation Manual
RS-485 DEVICES
AQP: 100%
FFC: 100%
iAL: 100%
SWC: 100%
VSP: 100%
DIAGNOSTICS
Revisions >
Alerts >
RS-485 Devices >
Section 8. Service Mode
MAIN>SERVICE MODE
Service Mode is used for safety purposes to shut
off power to all equipment during service or
troubleshooting.
Settings available through this menu:
• Auto
Indicates that equipment is turned on and running
according to system programming.
• Service
Indicates that all equipment is turned off until system is
manually turned to Auto by service technician.
• Timeout
Indicates that all equipment will remain turned off for
three (3) hours and then resume running according to
system programming after that time period.
Zodiac
12:40PM
Pool Mode O
Pool Heater 26°C
Spa Mode O
Spa Heater O
Settings >
Devices >
Service Menu >
SERVICE MENU
Auto
Service
Timeout
Zodiac
12:40PM
Pool Mode O
Pool Heater 26°C
Spa Mode O
Spa Heater O
Settings >
Devices >
Service Menu >
SERVICE MENU
Auto
Service
Timeout
Other manuals for AquaLink TRi
2
Table of contents
Other Zodiac Controllers manuals