TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Little or no
discharge
1. Casing not initially lled with water 1. Fill pump casing
2. Suction lift too high, or too long 2. Move pump closer to water source
3. Hole or air leak in suction line 3. Repair or replace. Use pipe tape and
pipe sealing compound
4. Foot valve too small 4. Match foot valve to piping or install
one size larger foot valve.
5. Foot valve or suction line not
submerged deep enough in water
5. Submerge lower in water
6. Motor wired incorrectly 6. Check wiring diagram
7. Casing gasket leaking 7. Replace
8. Suction or discharge line valves
closed
8. Open
Pump will not
deliver water
or develop
pressure
1. No priming water in casing 1. Fill pump casing
2. Leak in suction line 2. Repair or replace
3. Discharge line is closed and priming
air has nowhere to go
3. Open ball valve
4. Suction line (or valve) is closed 4. Open
5. Foot valve is leaking 5. Replace foot valve
6. Suction screen clogged 6. Clean or replace
Loss of suction 1. Air leak in suction line 1. Repair or replace
2. Suction lift too high 2. Lower suction lift, install foot valve
and prime
3. Insucient inlet pressure or suction
head
3. Increase inlet pressure by adding
more water to tank or increasing back
pressure
4. Clogged foot valve or strainer 4. Unclog
Pump vibrates
and/or makes
excessive
noise
1. Mounting plate or foundation not rigid
enough
1. Reinforce
2. Foreign material in pump 2. Disassemble pump and clean
3. Impeller damaged 3. Replace
4. Worn motor bearings 4. Replace
Pump will not
start or run
1. Improperly wired 1. Check wiring diagram on motor
2. Blown fuse or open circuit breaker 2. Replace fuse or close circuit breaker
3. Loose or broken wiring 3. Tighten connections, replace broken
wiring
4. Stone or foreign object lodged in
impeller
4. Disassemble pump and remove
foreign object
5. Motor shorted out 5. Replace
6. Thermal overload has opened circuit 6. Allow unit to cool, restart after reason
for overload has been determined
Please review the following troubleshooting questions before returning a pump as defective.
If you have any questions, please call Customer Service at (800) 584-8089.
MODEL LIQUID PUMP
LR90197
US
REV
DATE CODE:/CÓDIGO DE FECHA
Made in USA • Hecho en EE.UU.
Kendallville, IN 46755 • USA
QUICK TROUBLE-SHOOTING CHECKLIST
RESET
RESET
TEST
TEST
IL1381
LR90197
UL Std. No. 778
ENCLOSURE 3
starwatersystems.com
Pump: ES05S Rev: B
Motor: 98L105
HP: 1/2 PH 1Hz 60
Volts 115/230 S.F. 1.2 Amps 6.4/3.2
S.F. Amps: 8.6/4.3 RPM 3450 Type C
Duty: Cont. Temp 65C KVA Code G
Frame 56L Ins Class B
Factory prewired for 115V Thermally protected automatic
Check voltage of power source Use copper conductors only
ELECTRICAL HAZARD
Improper installation may result in re, explosion, electrical short or injury. Replace all covers
before operating. Ground motor in accordance with local and national electrical codes.
Disconnect power source before touching internal parts. Motors equipped with automatic
protection may restart without warning.
See instruction manual for proper installation procedure.
Se reporter au manuel d’instructions pour suivre la procédure adéquate d’installation.
Consulte el instructive para conocer el procedimiento de instalación correcto.
L1
L2A B
L1
L2A B
IL0180
YELLOW
115 VOLT
SINGLE PHASE
LINE
230 VOLT
SINGLE PHASE
LINE
WHITE
GRAY
RED
TAN
YELLOW
WHITE
GRAY
RED
TAN
DATE CODE: 0218* Made in USA
1. Check date code to make sure pump is within
warranty period. Date code is the month and the
year.
(Example: 0318 is March of 2018. Date Code is
found on the top of the pump.)
2. Make certain that the power source matches
the pump requirements. This pump has a dual
voltage motor and can run on 115 V or 230 V.
This pump is pre-wired at the factory to run on
115 V.
3. If pump does not run, check the GFI or breaker
panel switch to make it is in full operation.
4. If the pump runs all the time, make sure the
pump has been primed correctly. If pump is not
holding the prime, inspect check valve, foot
valve, and piping, then re-prime.
5. If the pump runs but won’t shut off, check
pressure switch.