Contents
Dear Customers.................................................................... 2
Preliminary Remarks ............................................................. 2
Precautions........................................................................... 2
Parts Identification................................................................ 5
Symbols................................................................................ 6
Operation Mode.................................................................... 8
Using the Monitor ................................................................. 9
Installing / Changing the Batteries ................................... 9
Connecting the Air Hose ................................................ 10
Connecting the AC Adapter............................................ 10
Selecting the Correct Cuff Size ....................................... 11
Applying the Arm Cuff ................................................... 11
How to Take Accurate Measurements............................. 13
Measurement................................................................. 13
After Measurement ........................................................ 13
Measurements .................................................................... 14
Normal Measurement..................................................... 14
Measurement with the Desired Systolic Pressure ............ 15
Notes for Accurate Measurement ................................... 15
Recalling the Memory Data ................................................. 16
What Is The IHB/AFib Indicator? .......................................... 17
What Is The AFib? ............................................................... 17
%IHB/AFib.......................................................................... 17
Pressure Bar Indicator ......................................................... 18
WHO Classification Indicator ............................................... 18
About Blood Pressure.......................................................... 18
What is Blood Pressure? ................................................. 18
What is Hypertension and How is it Controlled?.............. 19
Why Measure Blood Pressure at Home?........................... 19
WHO Blood Pressure Classification ................................. 19
Blood Pressure Variations............................................... 19
Troubleshooting ................................................................. 20
Maintenance ....................................................................... 21
Technical Data.................................................................... 21

English 2
Dear Customers
Congratulations on purchasing a state-of-the-art A&D blood pressure
monitor. Designed for ease of use and accuracy, this device will facilitate
your daily blood pressure regimen.
We recommend that you read through this manual carefully before
using the device for the first time.
Preliminary Remarks
This device conforms to the European Directive 93/42 EEC for Medical
Products. This is made evident by the mark of conformity. (0123:
The reference number to the involved notified body)
The device is designed for use on adults, not newborns or infants.
Environment for use. The device is for use to operate by yourself in the
home healthcare environment.
This device is designed to measure blood pressure and pulse rate of
people for diagnosis.
Precautions
Precision components are used in the construction of this device. Extremes
in temperature, humidity, direct sunlight, shock or dust should be avoided.
Clean the device and cuff with a dry, soft cloth or a cloth dampened with
water and a neutral detergent. Never use alcohol, benzene, thinner or
other harsh chemicals to clean the device or cuff.
Avoid tightly folding the cuff or storing the hose tightly twisted for long
periods, as such treatment may shorten the life of the components.
Take care to avoid accidental strangulation of babies or infants with the hose
and cable.
Do not twist the air hose during measurement. This may cause injury due
to continuous cuff pressure.
The device and cuff are not water resistant. Prevent rain, sweat and water
from soiling the device and cuff.
Measurements may be distorted if the device is used close to televisions,
microwave ovens, cellular telephones, X-ray or other devices with strong
electrical fields.
Wireless communication devices, such as home networking devices, mobile
phones, cordless phones and their base stations, walkie-talkies can affect
this blood pressure monitor.
Therefore, a minimum distance of 30 cm should be kept from such devices.
When reusing the device, confirm that the device is clean.

English 3
Used equipment, parts and batteries are not treated as ordinary
household waste, and must be disposed of according to the applicable
local regulations.
When the AC adapter is used, make sure that the AC adapter can be
readily removed from the electrical outlet when necessary.
Do not modify the device. It may cause accidents or damage to the device.
To measure blood pressure, the arm must be squeezed by the cuff hard
enough to temporarily stop blood flow through the artery. This may cause
pain, numbness or a temporary red mark to the arm. This condition will
appear especially when measurement is repeated successively. Any pain,
numbness, or red marks will disappear with time.
Measuring blood pressure too frequently may cause harm due to blood flow
interference. Check that the operation of the device does not result in
prolonged impairment of blood circulation, when using the device
repeatedly.
If you have had a mastectomy, please consult a doctor before using the device.
Do not let children use the device by themselves and do not use the device
in a place within the reach of infants. It may cause accidents or damage.
There are small parts that may cause a choking hazard if swallowed by
mistake by infants.
Unplug the AC adapter when not in use during the measurement.
Use of accessories not detailed in this manual may compromise safety.
Should the battery short-circuit, it may become hot and potentially cause
burns.
Allow the device to adapt to the surrounding environment before use (about
one hour).
Clinical testing has not been conducted on newborn infants and pregnant
woman. Do not use on newborn infants or pregnant woman.
Do not touch the batteries, the DC jack, and the patient at the same time.
That may result in electrical shock.
Do not inflate without wrapping the cuff around the upper arm.
Contraindications
The following are precautions for proper use of the device.
Do not apply the cuff on an arm with another medical electrical equipment
attached. The equipment may not function properly.
People who have a severe circulatory deficit in the arm must consult a
doctor before using the device, to avoid medical problems.
Do not self-diagnose the measurement results and start treatment by
yourself. Always consult your doctor for evaluation of the results and
treatment.
Do not apply the cuff on an arm with an unhealed wound.
Do not apply the cuff on an arm receiving an intravenous drip or blood
transfusion. It may cause injury or accidents.
Other manuals for UA-767S-W
1
Table of contents
Languages:
Other A&D Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Getinge
Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics
Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care
Pressalit Care R1100 Mounting instruction

Denas MS
Denas MS DENAS-T operating manual

bort medical
bort medical ActiveColor quick guide

AccuVein
AccuVein AV400 user manual