Quick Start Guide
Relion® 630 series
Display Default view can be selected from e.g. single line diagram (SLD), measurement, events
Self-supervision and
protection indicator LEDs
Ready-LED steady: OK, Ready-LED flashing: Internal Relay Fault (IRF), Start-LED steady: protection started,
Start-LED flashing: protection function blocked, Trip-LED: protection operated
Programmable LEDs Can be programmed for alarming and indication with latching and/or flashing features in 3 colors
Function buttons Can be configured either as menu shortcuts or control buttons
Object control buttons Press open/close and confirm by pressing enter. If there is more than one controllable object select the object
first with navigation buttons. Note: R/L button has to be in Local mode.
Escape / Cancel Used for canceling actions and leaving setting mode without saving the values. Returns back to menu.

Navigation buttons Left = go back, Right = go further, Up = scroll up, Down = scroll down. Up/down can also be used when
selecting controllable objects like breakers and switches in single line diagram.
Enter Entering to parameter setting mode and confirming new values or selection in dialogs
Authorization If authorization is used you can log in or log out using this button
 Clear Clearing events and indications, see next page for further details
 LED text view Multipage programmable LED text view. Press to see the 3 sets of 15 LED texts.
 Menu Switch views in between the main menu and default view
 Remote / Lemote Changes the control between Local/Remote
 Help View help menu
 Front communication port RJ-45 connection











2QUICK START GUIDE RELION® 630 SERIES
—
Using the local HMI
Accessing main menu
Press to navigate between main menu and default screen.
Controlling circuit breakers and disconnectors
The primary equipment can be controlled via the LHMI with
the Open and Close buttons when the IED is set to local control
mode and the user is authorized to access control operations.
Select  and the SLD will display all
controllable objects. Select the object with or .
Currently selected object is indicated with a square border.
Press to open or to close the object.
Changing the display contrast
Hold and press or to change the display contrast.
To store a selected contrast, change the ContrastLevel
parameter via .
Changing the language
 and press . Change the language
using or . Press to confirm the selection. Commit
the changes. All languages that are available in the firmware
version loaded are visible. Most of the IED‘s parameters
can be changed in the same way as language.
Changing the default view
The default view of the display is Main menu unless set
otherwise.
Select 
DefaultScreen and press to confirm the selection.
Change the default view with or and press to
confirm the selection.
Clearing events and indications
Go to clear menu by pressing or selecting Clear from
the main menu. Then select what you want to clear with
and keys. Press , select OK to confirm the selection or
Cancel to cancel the selection and press .
Changing the overcurrent start value
The IED contains only one setting group by default. The number
of setting groups can be selected from 1 to 4.
 select setting group,
1 and press 
.
Press and change the value by using or or
or keys. Press when the setting value is correct.
You can change all settings in the same way. The most
common function block names are described at the end
of this document.
Saving settings
After making changes to parameters they have to be saved
to get them into use. Save the settings by going back to main
menu by pressing or using the key. When IED asks
confirmation to save setting, answer “Yes“. Settings will be
effective as soon as you accept the “yes“ except from some
parameters marked with a ! require the IED to be rebooted
before the changes can be taken into use.
Monitoring alarm data
Active alarms are indicated by the alarm LEDs and the LED in
the Multipage button. The alarms are configured with PCM600.
The alarm type and information depend on the application
configuration. Press to open the alarm view. Press or
to move between the active alarms in the current page,
or press to switch between the three alarm pages.
Press to open a dialog box that shows more detailed
information about the selected alarm.
Checking the value of currents and voltages of the last fault


Checking IED order code, serial number, production date
and product version

Checking IED status
The IED self-supervision handles internal run-time fault
situations. The main indication of an internal fault is a flashing
green Ready LED. More detailed information can be found from

Rebooting the IED
Reboot the IED by switching the auxiliary power off and
then back on.
Using the function buttons
The function buttons can be configured either as menu
shortcuts or control buttons. Configurations can be made
with PCM600. The buttons are functional only when the
function button panel is visible.
Press any function button to open the function button panel,
no other actions will happen on the first press. After the panel
is open press the wanted button to either jump to a certain
menu item or hold it for at least half a second to initiate a
control signal. Press to close the function button panel.
Complete customer documentation is available in the product
pages that can be accessed through abb.com/relion.
QUICK START GUIDE RELION® 630 SERIES 3
—
Most common function blocks
Function  
Protection
Three-phase non-directional overcurrent, low stage PHLPTOC 3I>
Three-phase non-directional overcurrent, high stage PHHPTOC 3I>>
Three-phase non-directional overcurrent, instantaneous stage PHIPTOC 3I>>>
Three-phase directional overcurrent, low stage DPHLPDOC 3I> →
Three-phase directional overcurrent, high stage DPHHPDOC 3I>> →
Automatic switch-onto-fault logic CVRSOF CVRSOF
Autoreclosing DARREC O → I
Non-directional earth-fault, low stage EFLPTOC Io>
Non-directional earth-fault, high stage EFHPTOC Io>>
Non-directional earth-fault, instantaneous EFIPTOC Io>>>
Directional earth-fault, low stage DEFLPDEF Io> →
Directional earth-fault, high stage DEFHPDEF Io>> →
Transient/intermittent earth-fault INTRPTEF Io> → IEF
Admittance-based earth-fault protection EFPADM Yo> →
Wattmetric earth-fault protection WPWDE Po> →
Rotor earth-fault protection MREFPTOC Io>R
Motor stall protection JAMPTOC Ist>
Three-phase thermal overload protection for motors MPTTR 3Ith>M
Loss of load protection LOFLPTUC 3I<
Three-phase thermal overload protection for feeder T1PTTR 3lth>
Phase discontinuity PDNSPTOC I2/I1>
Three-phase current inrush detection INRPHAR 3I2f>
Three-phase overvoltage PHPTOV 3U>
Three-phase undervoltage PHPTUV 3U<
Positive-sequence overvoltage PSPTOV U1>
Positive-sequence undervoltage PSPTUV U1<
Negative-sequence overvoltage NSPTOV U2>
Residual overvoltage ROVPTOV Uo>
Frequency gradient DAPFRC df/dt>
Overfrequency DAPTOF f >
Underfrequency DAPTUF f <
Load shedding LSHDPFRQ f<, df/dt<
Circuit-breaker failure CCBRBRF 3I>/Io>BF
Tripping logic TRPPTRC I → O
Multipurpose analog protection MAPGAPC MAP
Transformer differential protection for two-winding transformers TR2PTDF 3 d I >T
Optional functions
Tap changer control with voltage regulator OLATCC COLTC
Distance protection DSTPDIS Z<
Fault Location SCEFRFLO FLOC
Synchrocheck SYNCRSYN SYNC
The most common function blocks are listed below, please refer to the 620 series Technical Manual for
the full list. The available function blocks varies depending on the selected IED and configuration used.
1MRS757577 REV B EN 02-2019
—
We reserve the right to make technical changes or modify the contents
of this document without prior notice. With regard to purchase orders,
the agreed particulars shall prevail. ABB does not accept any responsibility
whatsoever for potential errors or possible lack of information in this
document.
We reserve all rights in this document and in the subject matter and
illustrations contained therein. Any reproduction, disclosure to third
parties or utilization of its
contents – in whole or in parts – is forbidden
without prior written consent of ABB.
Copyright© 2019 ABB. All rights reserved.
—
For more information, please contact
ABB Distribution Solutions
P.O. Box 699
FI-65101 Vaasa, Finland
Phone: + 358 10 22 11
abb.com/substationautomation

This manual suits for next models

2

Other ABB Control System manuals

ABB Relion 670 series User manual

ABB

ABB Relion 670 series User manual

ABB SafeGear MCC User manual

ABB

ABB SafeGear MCC User manual

ABB LVS Digital FC610 User manual

ABB

ABB LVS Digital FC610 User manual

ABB Relion REC670 User manual

ABB

ABB Relion REC670 User manual

ABB MicroSCADA Pro SYS 600C 2.93 User manual

ABB

ABB MicroSCADA Pro SYS 600C 2.93 User manual

ABB ACSM1 Series User manual

ABB

ABB ACSM1 Series User manual

ABB ABILITY SSC600 User manual

ABB

ABB ABILITY SSC600 User manual

ABB Relion 615 series User manual

ABB

ABB Relion 615 series User manual

ABB Ability 800xA Series User manual

ABB

ABB Ability 800xA Series User manual

ABB Relion 670 series User guide

ABB

ABB Relion 670 series User guide

ABB MNS iS Specification sheet

ABB

ABB MNS iS Specification sheet

ABB Advant AC500 User manual

ABB

ABB Advant AC500 User manual

ABB MOD 30ML User manual

ABB

ABB MOD 30ML User manual

ABB 620 Series ANSI User manual

ABB

ABB 620 Series ANSI User manual

ABB Relion 620 Series User manual

ABB

ABB Relion 620 Series User manual

ABB Ability 800xA Series Instruction Manual

ABB

ABB Ability 800xA Series Instruction Manual

ABB Ability 800xA Series Instruction Manual

ABB

ABB Ability 800xA Series Instruction Manual

ABB Ability 800xA Series Instruction Manual

ABB

ABB Ability 800xA Series Instruction Manual

ABB C581 User manual

ABB

ABB C581 User manual

ABB Relion 615 series Datasheet

ABB

ABB Relion 615 series Datasheet

ABB Relion REC670 User manual

ABB

ABB Relion REC670 User manual

ABB AC500 Series Installation instructions

ABB

ABB AC500 Series Installation instructions

ABB REC670 2.1 IEC User manual

ABB

ABB REC670 2.1 IEC User manual

ABB ACS800-02 User manual

ABB

ABB ACS800-02 User manual

Popular Control System manuals by other brands

Siemens SINUMERIK 840D sl operating manual

Siemens

Siemens SINUMERIK 840D sl operating manual

Stahl 8146/5 Series operating instructions

Stahl

Stahl 8146/5 Series operating instructions

Idex Hale Sam Technical manual

Idex

Idex Hale Sam Technical manual

Hitachi RET670 Commissioning manual

Hitachi

Hitachi RET670 Commissioning manual

HERA ZigBee Assembly and operating instructions

HERA

HERA ZigBee Assembly and operating instructions

Dual Inventive ZKL 3000 RC manual

Dual Inventive

Dual Inventive ZKL 3000 RC manual

Tigo TS4-A-O quick start guide

Tigo

Tigo TS4-A-O quick start guide

Rosenbauer LCS 2.0 Operation manual

Rosenbauer

Rosenbauer LCS 2.0 Operation manual

American DJ DMX Operator II user manual

American DJ

American DJ DMX Operator II user manual

Solar SR530C8Q operating instructions

Solar

Solar SR530C8Q operating instructions

Recalart Electronic MultiFun instruction manual

Recalart Electronic

Recalart Electronic MultiFun instruction manual

TouchTronics POWERTouch P1555 Series Service manual

TouchTronics

TouchTronics POWERTouch P1555 Series Service manual

Automatic Systems RSB 76E Technical manual

Automatic Systems

Automatic Systems RSB 76E Technical manual

GE Lighting DALI 64668 operating instructions

GE Lighting

GE Lighting DALI 64668 operating instructions

Radionics D2412 installation manual

Radionics

Radionics D2412 installation manual

Nuvation Energy NUVSSG-1250-100 product manual

Nuvation Energy

Nuvation Energy NUVSSG-1250-100 product manual

Zodiac iAqualink IQ904-P quick start guide

Zodiac

Zodiac iAqualink IQ904-P quick start guide

Nordson Eclipse EPC-30 Series instruction sheet

Nordson

Nordson Eclipse EPC-30 Series instruction sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.