ABB NE801 User manual

800xA Networks
NE801
User Manual
Power and productivity
for a better worldTM


800xA Networks
NE801
User Manual

NOTICE
This document contains information about one or more ABB products and may include a
description of or a reference to one or more standards that may be generally relevant to
the ABB products. The presence of any such description of a standard or reference to a
standard is not a representation that all of the ABB products referenced in this document
support all of the features of the described or referenced standard. In order to determine
the specic features supported by a particular ABB product, the reader should consult the
product specications for the particular ABB product.
ABB may have one or more patents or pending patent applications protecting the
intellectual property in the ABB products described in this document.
The information in this document is subject to change without notice and should not be
construed as a commitment by ABB. ABB assumes no responsibility for any errors that
may appear in this document.
In no event shall ABB be liable for direct, indirect, special, incidental or consequential
damages of any nature or kind arising from the use of this document, nor shall ABB be
liable for incidental or consequential damages arising from use of any software or hard-
ware described in this document.
This document and parts thereof must not be reproduced or copied without written
permission from ABB, and the contents thereof must not be imparted to a third party nor
used for any unauthorized purpose.
The software or hardware described in this document is furnished under a license and
may be used, copied, or disclosed only in accordance with the terms of such license.
This product meets the requirements specied in EMC Directive 2014/30/EU and in Low
Voltage Directive 2014/35/EU.
TRADEMARKS
All rights to copyrights, registered trademarks, and trademarks reside with their respective
owners.
Copyright © 2003-2017 by ABB.
All rights reserved.
Release: November 2017
Document number: 3BSE080637 C

Table of Contents
Safety
Warning ...........................................................................................................................................7
Licensing Information .....................................................................................................................7
Section 1 - Industrial Ethernet 5-port Switch
Features............................................................................................................................................9
Example of Applications .................................................................................................................9
Section 2 - Interface specications
Connections ...................................................................................................................................12
Power ............................................................................................................................................13
TX ............................................................................................................................................13
FX LC Multi- or Single Mode (Optional) ......................................................................................14
LED Indicators ..............................................................................................................................15
DIP Switch Settings NE801...........................................................................................................16
Section 3 - Installation
Mounting .......................................................................................................................................19
Removal...........................................................................................................................................21
FibreOpticHandling.......................................................................................................................21
Maintenance .......................................................................................................................21
Cleaning of the Optical Connectors ..............................................................................................21
Agency Approvals and Standards Compliance .............................................................................22
Type Tests and Environmental Conditions ....................................................................................22
3BSE080637 C 5

Table of Contents
6 3BSE080637 C

Safety
Warning
Do not look directly into bre optical bre port or any connected bre although
this unit is designed to meet the Class 1 Laser regulations.
To reduce the risk of re, use on No. 26 AWG or larger telecommunication line
cord.
Licensing Information
This device contains public available software which is under the GPL license. For
more information see legal.pdf included with all rmware releases. This product
includes software developed by the OpenSSL Project for use in the OpenSSL
Toolkit- http://www.openssl.org.
3BSE080637 C 7

Licensing Information Safety
8 3BSE080637 C

Section 1 Industrial Ethernet 5-port Switch
Section 1 Industrial Ethernet 5-port Switch
The NE801 is an Industrial Ethernet 5-port switch. All ports support auto-negotiation,
but DIP-switches also allow speed and duplex conguration of any individual TX
port. It is also possible to set up one port to monitor trafc to/from the switch. The
NE801 has been designed to meet high industrial specications, providing very high
dependability in harsh environmental conditions.
Features
• TX shields individually isolated
• Wide DC power range 12 – 48 VDC
• Wide temperature range
• Automatic MDI/MDI-X crossover
• LED indicators for Power, Speed, Duplex, Link and Trafc
• Port monitoring
• 35 mm DIN rail mounting
• Enable or disable of ow control
Example of Applications
• 5-port Switch
• Ethernet isolator, for STP networks
3BSE080637 C 9

Section 1 Industrial Ethernet 5-port Switch
10 3BSE080637 C

Section 2 Interface specications
Section 2 Interface Specications
3BSE080637 C 11
Power NE801
Rated Voltage 12 –48 VDC, polarity protected
Operating voltage 9.6 – 57.6 VDC
Rated Current 350 mA @12
Rated frequency DC
Startup current* 2 x Rated current
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm2(AWG
24 – 12)
Ethernet TX
Electrical
specication
IEEE std 802.3. 2000 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual
or auto
Duplex Full or half, manual or auto
Connection RJ-45
Circuit type SELV
Transmission
range
100m

Connections
Figure 1. Connections
Section 2 Interface specications
12 3BSE080637 C
Ethernet FX
Electrical
specication
IEEE std 802.3. 2003 Edition
Data rate 100 Mbit/s
Duplex Full or half, manual or auto
Transmission
range
2km
Connection LC
Circuit type Optical
Number of ports 1

Section 2 Interface specications
Power
TX
The NE801 supports redundant power connection. The positive input are +VA and
+VB, the negative input for both supplies are COM. The power is drawn from the
input with the highest voltage. Figure 2 shows the screw terminal.
Figure 2. Screw Terminal
Ethernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover as
shown in Figure 3.
3BSE080637 C 13

Figure 3. Ethernet TX Connection
Section 2 Interface specications
CAT 5 cable is recommended. Unshielded (UTP) or shielded (STP) connector
might be used.
FX LC Multi- or Single Mode (Optional)
Figure 4 shows the 1310nm multimode bre transceiver with LC-connector, and
indicated range 2km. The dust protection plug shall be mounted when no bre is
connected.
14 3BSE080637 C

Section 2 Interface specications
Figure 4. Ethernet FX connection
LED Indicators
At power on the PWR ashes during initializing.
3BSE080637 C 15
Indicators (LED) Power (PWR)
Link (LINK) of every port
Speed (SPD) and duplex (DPX) of TX ports
LED Status Indication
PWR ON Internal power, initializing OK
Slow
ash
Initialization progressing
Fast ash Initialization error
LINK OFF No Ethernet link
ON Good Ethernet link
FLASH Ethernet data is transmitted or received,
trafc indication
SPD OFF 10 Mbit/s
(TX only) ON 100 Mbit/s
DPX OFF Half duplex
(TX only) ON Full duplex

16 3BSE080637 C
Section 2 Interface specications
DIP Switch Settings NE801
DIP-switches are accessible under the lid on top of the unit as shown in Figure 5.
DIP-switches are used to congure the unit.
Figure 5. DIP Switch Settings
Prevent damage to internal electronics from electrostatic discharges (ESD) by
discharging your body to a grounding point (e.g. use of wrist strap), before the lid
on top/front of the unit is removed.
Do not open the connected equipment. Prevent access to hazardous voltages
by disconnecting the unit from AC/DC mains supply and all other electrical
connections.
When conguration via DIP-switches, the settings of DIP-switches congure the
unit only after a reboot (power off/on).
To be observe when the DIP-switches will be congured,
• speed and duplex setting only valid when auto-negotiation is disabled.
• when monitoring selected all outgoing packets from the switch is also copied to
the port 1.
• speed and duplex switch settings are ignored for FX ports.
• If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X
conguration.

Port 3 settings
ON
1 2 3 4 5 6 7 8
S1 Auto-negotiation and
auto MDI/MDI-X disabled
ON
1 2 3 4 5 6 7 8
S1 Auto-negotiation and
auto MDI/MDI-X enabled
ON
1 2 3 4 5 6 7 8
S1 10 Mbit/s speed selected
ON
1 2 3 4 5 6 7 8
S1 100 Mbit/s speed selected
ON
1 2 3 4 5 6 7 8
S2 Half duplex selected
ON
1 2 3 4 5 6 7 8
S2 Full duplex selected
Port 1 settings
ON
1 2 3 4 5 6 7 8
S1 Auto-negotiation and
auto MDI/MDI-X disabled
ON
1 2 3 4 5 6 7 8
S1 Auto-negotiation and
auto MDI/MDI-X enabled
ON
1 2 3 4 5 6 7 8
S1 10 Mbit/s speed selected
ON
1 2 3 4 5 6 7 8
S1 100 Mbit/s speed selected
ON
1 2 3 4 5 6 7 8
S1 Half duplex selected
ON
1 2 3 4 5 6 7 8
S1 Full duplex selected
Port 2 settings
ON
1 2 3 4 5 6 7 8
S1 Auto-negotiation and
auto MDI/MDI-X disabled
ON
1 2 3 4 5 6 7 8
S1 Auto-negotiation and
auto MDI/MDI-X enabled
ON
1 2 3 4 5 6 7 8
S1 10 Mbit/s speed selected
ON
1 2 3 4 5 6 7 8
S1 100 Mbit/s speed selected
ON
1 2 3 4 5 6 7 8
S1 Half duplex selected
ON
1 2 3 4 5 6 7 8
S1 Full duplex selected
Port 4 settings
ON
1 2 3 4 5 6 7 8
S2 Auto-negotiation and
auto MDI/MDI-X disabled
ON
1 2 3 4 5 6 7 8
S2 Auto-negotiation and
auto MDI/MDI-X enabled
ON
1 2 3 4 5 6 7 8
S2 10 Mbit/s speed selected
ON
1 2 3 4 5 6 7 8
S2 100 Mbit/s speed selected
ON
1 2 3 4 5 6 7 8
S2 Half duplex selected
ON
1 2 3 4 5 6 7 8
S2 Full duplex selected
Port 5 settings
ON
1 2 3 4 5 6 7 8
S2 Auto-negotiation and
auto MDI/MDI-X disabled
ON
1 2 3 4 5 6 7 8
S2 Auto-negotiation and
auto MDI/MDI-X enabled
ON
1 2 3 4 5 6 7 8
S2 10 Mbit/s speed selected
ON
1 2 3 4 5 6 7 8
S2 100 Mbit/s speed selected
ON
1 2 3 4 5 6 7 8
S2 Half duplex selected
ON
1 2 3 4 5 6 7 8
S2 Full duplex selected
Port mirroring settings
S2 No monitoring selected
S2 Monitoring selected
Factory settings
S1
S2
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5
ON
1 2 3 4 5
ON
1 2 3 4 5
Port 5 settings
ON
1 2 3 4 5 6 7 8
S2 Auto-negotiation and
auto MDI/MDI-X disabled
ON
1 2 3 4 5 6 7 8
S2 Auto-negotiation and
auto MDI/MDI-X enabled
ON
1 2 3 4 5 6 7 8
S2 10 Mbit/s speed selected
ON
1 2 3 4 5 6 7 8
S2 100 Mbit/s speed selected
ON
1 2 3 4 5 6 7 8
S2 Half duplex selected
ON
1 2 3 4 5 6 7 8
S2 Full duplex selected
Port mirroring settings
S2 No monitoring selected
S2 Monitoring selected
Factory settings
S1
S2
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5
ON
1 2 3 4 5
ON
1 2 3 4 5
3BSE080637 C 17
Section 2 Interface specications

Section 2 Interface specications
18 3BSE080637 C

Section 3 Installation
Section 3 Installation
Before mounting or removing the unit: Prevent damage to internal electronics from
electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use
of wrist strap). Prevent access to hazardous voltages by disconnecting the unit from
AC/DC mains supply and all other electrical connections.
Mounting
This subsection describes on how to mount and remove the device.
Mounting
This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a
wall or cabinet backplate as shown in Figure 6.
Figure 6. Mounting the Device
This unit uses convection cooling. To avoid obstructing the airow around the unit,
use the following spacing rules. Recommended spacing 25 mm (1.0 inch)
3BSE080637 C 19
Table of contents
Other ABB Switch manuals

ABB
ABB FAP 1011 User manual

ABB
ABB ATS-16 A User manual

ABB
ABB Sense7 Series User manual

ABB
ABB EOHU Series Training manual

ABB
ABB InLine II ZHBM-ITS Series User manual

ABB
ABB Zenith ZTG Series User manual

ABB
ABB LineStrong2 Series User manual

ABB
ABB OTM C 21D User manual

ABB
ABB ABB-free@home LS-1.1 User manual

ABB
ABB 3299H-A02182 Guide

ABB
ABB OTM C Series User manual

ABB
ABB NE802 User manual

ABB
ABB UniSec SDS Operating and maintenance instructions

ABB
ABB VUBB User manual

ABB
ABB SACE Tmax XT User manual

ABB
ABB ATS021 User manual

ABB
ABB 3299E-A32100 User manual

ABB
ABB EDS500 Series User manual

ABB
ABB JSTD20 User manual

ABB
ABB OTM C 21D User manual