ACTpro 4200 Operating and Installation Manual Rev 1.0
Features
This product consists of a 4-door controller housed inside a metal cabinet, complete with a monitored power supply.
The assembly as supplied provides the following features:
•ACTpro 4000 2 Door controller.
•ACTpro 200 2 Door controller door station.
•Up to 60,000 Users.
•Connection to PC over TCP/IP, USB or RS232/RS485.
•3 Amp Regulated Power Supply with battery backup provision.
•Steel Cabinet (thickness 1.2mm) with hinged lid.
•Space for two 7Ahr batteries (not included).
•Monitored power supply with automatic battery test.
•2 fused outputs for door locks.
•PSU status (AC fault, battery low) reported to controller and to The ACTWin pro software.
•Deep-Discharge protection of batteries.
•20mm ‘knockouts’ provided for external wiring at top and sides.
•40mm holes in the back of the cabinet for rear wiring entry.
Product Specification
Mains Supply
Mains Voltage 230 VAC + 10% / -15%
Frequency 50 Hz
Main Fuse 630 mA
Output Voltage (Output 1 and Output 2) 12 V DC fused at 1.25 Amp
Installation Notes
•On receipt the unit should be unpacked and inspected to ensure that no transit damage has occurred.
•Mount the ACTpro 4200 directly to the wall with the supplied screws.
•The unit must be mounted in a well-ventilated area that allows for accessibility after installation and must not
be adjacent to combustible materials or in an area that exceeds temperatures of 45°C. Adequate ventilation
should be provided to keep the unit cool and the ventilation slots around the cabinet should not be covered.
•Mains power should be connected to the ACTpro 4200 by a licensed electrician in accordance with local and
national codes.
•For continued protection against fire hazard, replace fuses with the same type and rating.
•A protective EARTH must be provided for safety in accordance with EN61010 Part 1 : 1993 : Clause 6.5.1.
•An appropriate Mains Isolation switch (Mains on/off) should be fitted between the AC input of the unit and the
equipment electrical supply plug to allow equipment servicing.
•Before any maintenance of the product, ensure mains is disconnected.
Ordering Information
Model Description Part Number
ACTpro 4200 4 door controller & 12 V DC 3amp power supply ACTpro 4200
2