SERIES 2 DATA SHEET
Adaptec 3Gb/s SATA & SAS RAID Family
with Intelligent Power Management
2045, 2405, 2805
Entry-level Unied Serial®(SATA/SAS) RAID Controllers
Deliver Performance and Energy Efciency
Product Highlights
3Gb/s throughput at each port
800MHz Dual Core RAID on
Chip (ROC)
– High-performance RAID 0, 1,
1E, 10 and JBOD
– 128MB DDR2 cache
Low-profile MD2 form factor
Supports up to 128 SATA/SAS
devices using SAS expanders
Supports SATA and SAS
tape drives
x8 PCI Express host interface
Enclosure management support
via LED header and SES2/
SGPIO
Intelligent Power Management
– Reduces power and cooling
costs by as much as 70%
Hybrid RAID 1 & 10: SSD +
HDD for Maximum Performance
and Reliability
>
Adaptec Series 2 Unied Serial RAID controllers
are designed to support hardware RAID 0, 1, 10
and JBOD while oering direct I/O connectivity
for SATA/SAS tape devices and hard disk drives.
Equipped with an industry-leading dual core
RAID on Chip (ROC), this family oers 128MB
of DDR2 533MHz write cache and supports up
to 128 devices using SAS expanders. ey
oer an x8 PCI Express host interface bus
connection in a low-prole MD2 form factor.
Series 2 controllers oers high bandwidth for I/O
applications and at the same time basic hardware
RAID functionality that is fully independent of
the host and operating system and compatible
with other Adaptec RAID controller families.
Hybrid RAID
With Hybrid RAID 1 & 10 the Series 2 controllers
oer maximum performance and reliability
by combining Solid State Drives (SSDs) and
Hard Disk Drives (HDDs) in a single array.
By performing read operations from the faster
SSD and write operations on both the SSDs and
HDDs the result is tremendous performance
gains over standard HDD RAID arrays. Hybrid
RAID oers the benets of both technologies
and allows a better cost per GB ratio than
comparable SSD-only RAID arrays.
The Case for Cache
e fastest way for a RAID controller to fulll
a read or write request is to serve data out of its
cache. Enabling the RAID controller cache oers
signicant performance benets, such as reduced
latency in I/O requests, bandwidth and queue
depths that surpass soware application limits,
and on-the-y parity calculations on sequential
writes.
Intelligent Power Management
e power required by disks is a primary
ongoing storage cost. Full power is maintained
to every disk whether it is actively being used or
not, which also increases cooling costs. Adaptec
Intelligent Power Management slashes power
and cooling costs by spinning down idle disks
and providing a lower power mode for active
disks.
One-view Storage Management
Adaptec Storage Manager™, a one-view tool
centralizes management of all Adaptec RAID
products.
Broad Operating System Support
Extensive operating system support includes
all major soware releases, such as Windows,
Linux, FreeBSD, and UNIX variants.
Compatibility, Reliability, and Support
e Series 2 family has been extensively tested
with third-party components to deliver the
utmost in compatibility. e cards are backed
by a 3-year warranty and the company’s
legendary technical support.
™
SERIES 2 DATA SHEET
Adaptec SATA & SAS RAID Family (2045, 2405, 2805)
PMC-Sierra, Inc.
1380 Bordeaux Drive
Sunnyvale, CA 94089 USA
Tel: +1 (408) 239-8000
© Copyright PMC-Sierra, Inc. 2011. All rights reserved. PMC, PMC-SIERRA and Adaptec are registered trademarks of PMC-Sierra, Inc. “Adaptec by PMC” is a trademark of PMC-Sierra, Inc.
Other product and company names mentioned herein may be trademarks of their respective owners. For a complete list of PMC-Sierra trademarks, see www.pmc-sierra.com/legal.
DS_Series2_111811_US Information subject to change without notice.
World Wide Web: www.adaptec.com
Pre-Sales Support: US and Canada: 1 (800) 442-7274 or (408) 957-7274 or [email protected]
UK: +44 1276 854 528 or [email protected]
Australia: +61-2-95031555
Singapore: +65-92351044
Adaptec Unified Serial Controller Family
Why to buy? Delivers a new price/performance level and enhanced reliability for entry-level applications
Customer Needs The better reliability offered by hardware RAID, and a feature set designed for the latest applications, including Linux open source driv-
ers and external connectivity, without needing to step up to the cost of a more sophisticated controller for their entry-level applications.
Intelligent Power Management Automated customer-configurable feature that reduces disk drive energy use by up to 70% without compromising application
performance. Two configurable modes supported:
Standby mode – low-power mode; drive rotates at reduced RPM when not in use (requires that the drive support Advanced Power
Management specification). See Adaptec compatibility report for a list of supported disk drives.
Power-off mode – Spin down drives when not in use.
RAID Features — Supports up to 128 SATA or SAS devices using SAS expanders
— RAID levels 0, 1, 1E, 10 and JBOD
— Quick initialization
— Online Capacity Expansion
— Copyback Hot Spare
— Dynamic caching algorithm
— Native Command Queuing (NCQ)
— Background initialization
— Hot-plug drive support
— RAID Level Migration
— Hot spares – global, dedicated, and pooled
— Automatic/manual rebuild of hot spares
— SAF-TE enclosure management
— Configurable stripe size
— S.M.A.R.T. support
— Multiple arrays per disk drive
— Dynamic sector repair
— Staggered drive spin-up
— Bootable array support
— Optimized Disk Utilization
Management Utilities Adaptec Storage Manager™ (ASM)
— Java-based GUI Management Utility
— Remote configuration, monitoring and notification
— ASM OS Support: Windows, Linux, SCO, Solaris
— Microsoft VDS Support
— SNMP, SMTP
— Remote firmware updates
ARCCONF
— Command Line Interface
Adaptec BIOS Configuration Utility (ACU)
— BIOS level configuration utility
— Flashable BIOS support
Operating System Windows 7, Windows XP, Server 2003/2008, Vista, Red Hat Enterprise Linux (RHEL), SUSE Linux Enterprise Server (SLES),
SCO OpenServer, UnixWare, Sun Solaris 10 x86, FreeBSD. The latest drivers are available at www.adaptec.com/support.
Physical Dimensions 2045/2405/2805 — 2.5”H x 6.6”L (167mm x 64mm)
Operating Temperature* 0°C to 55°C (with 200 LFM airflow)
Operating Voltage 0.42A @ 3.3VDC, 0.83A @ 12VDC
Regulatory Certification CE, FCC, UL, C-tick, VCCI
MTBF 2045: 1,425,898 hours @ 40°C, 2405: 1,415,623 @ 40°C, 2805: 1,134,890 hours @ 40°C
Warranty 3 years
Accessories No battery option
Adaptec RAID 2045 2405 2805
Order Part Number 2260300-R (single) 2260100-R (kit)
2260200-R (single)
2269600-R (kit)
2269500-R (single)
Form Factor MD2 - Low Profile MD2 - Low Profile MD2 - Low Profile
Ports 4 external 4 internal 8 internal
Connectors 1 SFF-8088 (ext.) 1 SFF-8087 (int.) 2 SFF-8087 (int.)
Bus Interface 8-Lane PCIe Gen1.1 8-Lane PCIe Gen1.1 8-Lane PCIe Gen1.1
Processor 800MHz 800MHz 800MHz
Cache 128MB 128MB 128MB
Fanout Cable/s (kits only) None (Single only) mSASx4 to 4xSATA w/sideband (0.5M) x1 mSASx4 to 4xSATA w/sideband (0.5M) x2
™
*Note: This Adaptec card contains a powerful RAID processor which requires adequate airflow to operate reliably. Please install this card only into server or PC chassis with recommended airflow (200 LFM).
Ambient temperature measured 1” away from the RAID processor.

Other manuals for 2045

2

This manual suits for next models

2

Other Adaptec Computer Hardware manuals

Adaptec RAID 5405 User manual

Adaptec

Adaptec RAID 5405 User manual

Adaptec Series 6 Reference guide

Adaptec

Adaptec Series 6 Reference guide

Adaptec SATA RAID FOR ADAPTEC User manual

Adaptec

Adaptec SATA RAID FOR ADAPTEC User manual

Adaptec PM1564U3 User manual

Adaptec

Adaptec PM1564U3 User manual

Adaptec ACB-2010A User manual

Adaptec

Adaptec ACB-2010A User manual

Adaptec SCSI 58300 User manual

Adaptec

Adaptec SCSI 58300 User manual

Adaptec 9110G User manual

Adaptec

Adaptec 9110G User manual

Adaptec RAID 2405Q User manual

Adaptec

Adaptec RAID 2405Q User manual

Adaptec 7210S Use and care manual

Adaptec

Adaptec 7210S Use and care manual

Adaptec PM3332UW User manual

Adaptec

Adaptec PM3332UW User manual

Adaptec ICP 5045BL User manual

Adaptec

Adaptec ICP 5045BL User manual

Adaptec 2100S - SCSI RAID Controller Safety guide

Adaptec

Adaptec 2100S - SCSI RAID Controller Safety guide

Adaptec 4000SAS User manual

Adaptec

Adaptec 4000SAS User manual

Adaptec Serial Attached SCSI (SAS) Expander Card User manual

Adaptec

Adaptec Serial Attached SCSI (SAS) Expander Card User manual

Adaptec 2045 User manual

Adaptec

Adaptec 2045 User manual

Adaptec M3093GX Operating and maintenance manual

Adaptec

Adaptec M3093GX Operating and maintenance manual

Adaptec ASA-7211C User manual

Adaptec

Adaptec ASA-7211C User manual

Adaptec GDT8114RZ User manual

Adaptec

Adaptec GDT8114RZ User manual

Adaptec 2010S - SCSI RAID Storage Controller User manual

Adaptec

Adaptec 2010S - SCSI RAID Storage Controller User manual

Adaptec RAID 5405Z User manual

Adaptec

Adaptec RAID 5405Z User manual

Adaptec DuraStor 7200S User manual

Adaptec

Adaptec DuraStor 7200S User manual

Adaptec ACB-5500 User manual

Adaptec

Adaptec ACB-5500 User manual

Adaptec RAID 2405 User manual

Adaptec

Adaptec RAID 2405 User manual

Adaptec PowerDomain 29160 User manual

Adaptec

Adaptec PowerDomain 29160 User manual

Popular Computer Hardware manuals by other brands

Panasonic PAW-FC Installation and maintenance manual

Panasonic

Panasonic PAW-FC Installation and maintenance manual

Intel ATX 3.0 Design guide

Intel

Intel ATX 3.0 Design guide

Harmonic Electra 9200 Component replacement guide

Harmonic

Harmonic Electra 9200 Component replacement guide

abaco systems FMC168 user manual

abaco systems

abaco systems FMC168 user manual

ST STM32F405 Series Reference manual

ST

ST STM32F405 Series Reference manual

AXIOMTEK eBOX660-872-FL Quick installation guide

AXIOMTEK

AXIOMTEK eBOX660-872-FL Quick installation guide

Renesas M16C/26 Series Reference book

Renesas

Renesas M16C/26 Series Reference book

ADLINK Technology SMARC NXP LEC-IMX8M user guide

ADLINK Technology

ADLINK Technology SMARC NXP LEC-IMX8M user guide

Silicon Laboratories UG507: xG23B user guide

Silicon Laboratories

Silicon Laboratories UG507: xG23B user guide

HighPoint RocketCache 3240X8 user guide

HighPoint

HighPoint RocketCache 3240X8 user guide

ST X-NUCLEO-S2868A2 user manual

ST

ST X-NUCLEO-S2868A2 user manual

Texas Instruments AM1808 Technical reference manual

Texas Instruments

Texas Instruments AM1808 Technical reference manual

Thermalright Silver Arrow ITX-R instruction manual

Thermalright

Thermalright Silver Arrow ITX-R instruction manual

Dell Latitude E4200 System Board Replacement

Dell

Dell Latitude E4200 System Board Replacement

Noctua NH-U9DO A3 installation manual

Noctua

Noctua NH-U9DO A3 installation manual

ekwb 115 Series user guide

ekwb

ekwb 115 Series user guide

ADLINK Technology NuPRO-840 DV user guide

ADLINK Technology

ADLINK Technology NuPRO-840 DV user guide

Advantech MIO-5377 user manual

Advantech

Advantech MIO-5377 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.