PROVISIONING (CONTINUED)
5Once the H2TU-C is successfully installed and provisioned, access the Monitor or
Performance menus to clear the Performance and Alarm History screens to ensure
useful data.
LOOPBACK TESTING
Initiate loopback testing from the HiGain maintenance terminal screen or use the MODE
and LBK pushbuttons. The inband codes below (except COLB and RULB) can also be sent
by a test set.
Copies of this publication or the technical practice (LTPH-UM-1049-xx) can be
downloaded from the ADC website at www.adc.com. To order a hard copy, please contact
your sales representative.
GNLB Loopback Commands
Loopback Inband Code Description
NLOC 1111000 DSX-1 signal is looped back to the network at the H2TU-C.
NREM 1110000 DSX-1 signal is looped back to the network at the H2TU-R.
SMJK 11000 DSX-1 signal is looped back to the network at the H2TU-R SmartJack module.
CREM 1111110 DS1 signal from customer is looped back to the customer at the H2TU-C.
CLOC 1111100 DS1 signal from customer is looped back to the customer at the H2TU-R.
Loopdown 11100 Deactivates any of the above loopbacks.
Front-Panel Alarm Messages(a)
(a) Front-panel alarm messages are listed in order of priority. ALRM displays prior to any alarm message.
Pressing the SEL button initiates an Alarm Cutoff (ACO) message.
Message Description
PWR FEED SHRT (b)
(b) Message displays repeatedly as long as the alarm condition exists and is not included in the priority order.
A short between the Tip and Ring of the HDSL2 pair.
PWR FEED GND (b) The HDSL2 loop is grounded.
PWR FEED OPEN (b) A line-power open condition.
LOSW The HDSL2 loop has lost synchronization. The span closest to the network has highest
priority.
MTA Indicates that the H2TU-C is in a metallic test access state.
LLOS No signal is detected at the DSX-1 input to the H2TU-C.
RLOS No signal is detected at the DS1 input to the H2TU-R.
LAIS (c)
(c) Does not activate the alarm relay access pin H.
Line Alarm Indication Signal.
RAIS (c) Remote Alarm Indication Signal.
TRCI (c) An RAI alarm (yellow LED) from the Customer Premises Equipment (CPE) with an
error-free signal from the line unit or network.
RRAI(c) An RAI alarm (yellow LED) from the CPE with errors from the line unit or network.
xxx-DBER (c) A system DS1 Bit Error Rate (BER) alarm. (xxx denotes either TUC or TUR.)
PRMF (c) H2TU-R Performance Report Messaging BER threshold exceeded at far end.
PRMN (c) H2TU-R Performance Report Messaging BER threshold exceeded at near end.
xxx-HBER A system HDSL2 Block Error Rate (BER) alarm. (xxx denotes either TUC or TUR.)
xxx-MAL The margin on the HDSL2 loop has dropped below the threshold setting. (xxx denotes
either TUC or TUR.)
xxx-LA The attenuation on the HDSL2 loop has exceeded the maximum threshold value. (xxx
denotes either TUC or TUR.)
To comply with the intrabuilding wiring requirements of GR-1089
CORE, Section 4.5.9, the shields of the ABAM-type cables that
connect the H2TU-C-319 List 4E DSX-1 output ports to the
cross-connect panel must be grounded at both ends.
Network
Customer
Premises
H2TU-C H2TU-R
TLOS*
NLOC CREM CLOC
1111000 NREM
1110000 1111100
1111110
11000
SMJK
When enabled,TLOS is an automatic loopback
that occurs with an LOS at the remote DS1 input.
*
DS1DSX-1
Front Panel Diagnostic Messages
Message Description (normal operating messages in bold)
A=xx The loop attenuation of the longest (maximum loss) span, measured in dB.
ACQ The multiplexers of the H2TU-C and H2TU-R are trying to establish synchronization.
ARM Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT? The H2TU-C is not receiving a response from the H2TU-R.
FERR A framing bit error occurred at H2TU-C DSX-1 input.
FLDL Flash download of firmware updates. (Contact Customer Service for update procedures.)
HES H2TU-C HDSL2 loop cyclical redundancy check (CRC) error.
LBPV A local bipolar violation has been received at the DSX-1 input to the H2TU-C.
M=xx Indicates the power of the received HDSL2 signal relative to noise (S/N with respect to
21.5 dB). Any value of 6 dB or greater is adequate for reliable system operation.
MNGD The H2TU-C is under control of the HMU-319 network management unit.
PWR FEED OFF HDSL2 span power is turned off.
PWR FEED ON Indicates that the HDSL2 span power is turned on and the loop is not grounded or shorted.
SIG The transceiversof the H2TU-C and H2TU-R are trying to establish contact with each other
on Span 1 of the HDSL2 loop.
Front-Panel Read-Only Settings Using MODE (a)
(a) Front-panel codes scroll in the order listed. The configured selections follow each code.
Message Description (default selections in bold)
VER x.xx Software version number of the H2TU-C-319.
LIST xx List number of the H2TU-C-319.
FRM xxxx Frame pattern received from the DSX-1 (SF, ESF, UNFR).
CODE xxxx Line code (AMI or B8ZS).
LATT xx Loop Attenuation threshold setting (38).
MARG xx Margin threshold setting (4).
EQL Indicates DSX-1 Equalizer setting: 0(0 to 132 ft.), 133 (133 to 265 ft.), 266 (266 to 398 ft.),
399 (399 to 532 ft.), or 533 (533 to 655 ft.).
RLBO Indicates H2TU-R line buildout setting: 0 dB, -7.5 dB, or -15 dB.
LPBK SmartJack loopback commands enabled (ENA) or disabled (DIS).
SPLB xxxx System configured for generic (GNLB) or special inband loopback commands (A1LB, A2LB, A3LB, A4LB,
A5LB).
PWRF HDSL2 line power disabled (OFF) or -180 Vdc (ON).
HBER 1E-6 or 1E-7 = indicates HDSL2 BER alarm threshold setting. NONE = no generation of a system
alarm due to BER.
DBER 24-hour DSX-1 BER alarm threshold enabled (ENA) or disabled (DIS).
LBTO Loopback timeout = NONE, 20, 60, 120 minutes, 8-hour, 24-hour.
DS1 DSX-1 line code = Bipolar with 8-Zero Substitution (B8ZS), Alternate Mark Inversion (AMI).
CONV H2TU-R frame format conversion = OFF (framing determined by the DS1 FRMG option),
ACON (autodetection of framing and potential frame conversion at the H2TU-R), or
FCON (autodetection of framing and forced frame format conversion at the H2TU-R).
FRMG DS1 frame formatting = AUTO (auto framing mode) or UNFR (unframed mode),
RDA Alarm indications due to remote DS1 LOS at H2TU-R input are enabled (ENA) or disabled (DIS).
ALMP Alarm pattern = Alarm Indication Signal (AIS) or Loss of Signal (LOS).
BPVT Bipolar Violation Transparency (BPVT) enabled (ENA) or disabled (DIS).
NLBP H2TU-R transmits either AIS or LOS towards CI for any network loopback.
TLOS Logic loopback at the H2TU-R is either enabled (ENA) or disabled (DIS) when an LOS occurs at its
DS1 input.
PRM Performance Report Messaging = OFF (no enhanced Performance Report Messaging), SPRM
(Supplemental PRM), NPRM (Network PRM), AUTO (H2TU-R generates both SPRMs and NPRMs
whenever possible).
NAIS If ALMP is set to AIS, indicates which pattern is sent to the network when a remote LOS or AIS
occurs. CI = AIS-CI sent to the network; AIS = AIS sent to the network.
ROVR Conversion of an ESF DS1 payload from the network with an embedded RAI pattern to an SF-RAI
pattern toward the CI at the H2TU-R is enabled (ENA) or disabled (DIS). CONV option must be set
to FCON or ACON.
RACI Conversion of a DS1 SF-RAI signal (yellow alarm) received by the H2TU-R to an SF-RAI-CI signal
toward the network is enabled (ENA) or disabled (DIS).
PBOC Indicates the power output levels of the H2TU-R customer unit toward the network. Default (DEF)
or enhanced (ENH).
PBON Indicates the power output levels of the H2TU-C network unit toward the customer. Default (DEF)
or enhanced (ENH).
Front-Panel System Information Messages (Scroll Mode)(a)
(a) To scroll through system information messages, press the MODE button for 3 or more seconds.
Code Description Code Description
CODE xxxx Line code setting (AMI or B8ZS). LIST xx List number of the H2TU-C.
FRM xxxx Frame pattern received from the
DSX-1 (SF, ESF, or UNFR). MARG xx Margin threshold (0 to 15 dB).
Default is 5.
LATT xx Loop attenuation threshold setting
(0 to 40 dB). Default is 32.VER x.xx Software version number.
Four-character display
System option pushbuttons
DSX-1 test access jacks
List number
Status LED
Displays status, provisioning, and
alarm messages. See table below
for a list of message descriptions.
Connect standard test equipment.
Craft port provisioning
To access all system maintenance, provisioning
and performance screens, connect a standard
9-pin terminal cable between the serial port on a PC
and the H2TU-C craft port.
LINE Provides splitting jack access to
(IN) and from (OUT) the HDSL2 span
at the DSX-1 interface.
BRG Provides non-intrusive bridging jack
access to (IN) and from (OUT) the
HDSL2 span at the DSX-1 interface.
Allows monitoring of the T1 payloads.
MaintenanceTerminal Modem Settings
9600 baud
8 data bits
No parity
1 stop bit
Hardware flow control:OFF
Terminal emulation software:VT100
S
E
L
M
O
D
E
O
U
T
I
N
B
R
G
B
R
G
L
I
N
E
L
I
N
E
H
2
T
U
*
C
3
1
9
R
S
2
3
2
SETUP
STATUS
Front panel
A Customer Remote (CREM)
loopback or a Network Local
(NLOC) loopback is in effect.
Green LED Normal operation.
HDSL2 acquisition or
system alarm.
Red LED Fuse alarm.
Flashing Red LED
Yellow LED
FlashingYellow LED System is in Armed (ARM)
mode.
Off Line power is off.
HiGain
HDSL2
L
DCE
Use the MODE and pushbuttons to review all system
parameters, including user-configured settings, and to
activate loopbacks.
SEL
To display system parameters: Press the MODE pushbutton
for at least 3 seconds to place the front-panel display in Scroll
mode.When it has finished scrolling through all the system
parameters, the display returns to its normal mode.
To initiate a dual loopback: Press the SEL pushbutton for
more than 3 seconds to activate both the NLOC and CREM
loopbacks.If a loopback condition already exists, this will
loop down all existing loopbacks.Press the LBK pushbutton
again for more than 3 seconds to reactivate the dual loopback.
To initiate a manual loopback:
1Press both the MODE and SEL pushbuttons for at least
5 seconds.The following message appears:
2 Press the SEL pushbutton to activate the NLOC loopback
or press MODE to advance to the next loopback selection.
MAN LBK NLO?
Card handle
(CLEI code and ECI bar code label on outside of handle)
3
4
5
6
C
D
E
F
H7
8
J
9
K
10
L
GND
HDSL2SpanTip HDSL2SpanRing
System alarm Management bus
Frame ground -48V BAT
Fusealarm*
Factory useonly
1
A
(IN)DSX-1Tip DSX-1Ring(IN)
2
B
(OUT)DSX-1 Tip1 DSX-1Ring1(OUT)
* Fuse alarm is normally floating
and at -48 Vdc when activated.
1
19
(IN)DSX-1Tip DSX-1Ring(IN)
2
20
(OUT)DSX-1 Tip1 DSX-1Ring1(OUT)
13
14
31
32
33 15
16
34
17
35
18
36
{
MUXPort
{
AUXPort
{
MUXPort
{
AUXPort
(OUT)MTAF Tip
(IN) TipMTAF
{
Metallic MTAF (OUT)Ring
MTAF Ring(IN)
{
Access
(TB6) Metallic Access
(TB6)
Segment2
Segment1
Segment3
Card-edge connector
4E