manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Network Card
  8. •
  9. ADTRAN HRE/T200 User manual

ADTRAN HRE/T200 User manual

Other ADTRAN Network Card manuals

ADTRAN 900 Series User manual

ADTRAN

ADTRAN 900 Series User manual

ADTRAN 239 T1 HDSL4 Instruction Manual

ADTRAN

ADTRAN 239 T1 HDSL4 Instruction Manual

ADTRAN NetVanta Internet-Based WAN Backup User manual

ADTRAN

ADTRAN NetVanta Internet-Based WAN Backup User manual

ADTRAN TRACER Protection Switch User manual

ADTRAN

ADTRAN TRACER Protection Switch User manual

ADTRAN DDM+ H2TU-C Instruction Manual

ADTRAN

ADTRAN DDM+ H2TU-C Instruction Manual

ADTRAN 239 H4R User manual

ADTRAN

ADTRAN 239 H4R User manual

ADTRAN 5000 Series Operating manual

ADTRAN

ADTRAN 5000 Series Operating manual

ADTRAN ATLAS 800 Series Module Nx56/64 Bonding User manual

ADTRAN

ADTRAN ATLAS 800 Series Module Nx56/64 Bonding User manual

ADTRAN NetVanta 1000R Series Operating manual

ADTRAN

ADTRAN NetVanta 1000R Series Operating manual

ADTRAN 20 Ohm Adapter User manual

ADTRAN

ADTRAN 20 Ohm Adapter User manual

ADTRAN Type 400 Instruction Manual

ADTRAN

ADTRAN Type 400 Instruction Manual

ADTRAN TRACER 6000 SERIES User guide

ADTRAN

ADTRAN TRACER 6000 SERIES User guide

ADTRAN AHDSL2 Instruction Manual

ADTRAN

ADTRAN AHDSL2 Instruction Manual

ADTRAN 3000 HTU-C User manual

ADTRAN

ADTRAN 3000 HTU-C User manual

ADTRAN ATLAS 550 User manual

ADTRAN

ADTRAN ATLAS 550 User manual

ADTRAN DS3 User manual

ADTRAN

ADTRAN DS3 User manual

ADTRAN ATLAS 800PLUS User manual

ADTRAN

ADTRAN ATLAS 800PLUS User manual

ADTRAN TOTAL ACCESS OPTI-T200 User manual

ADTRAN

ADTRAN TOTAL ACCESS OPTI-T200 User manual

ADTRAN AHT1U User manual

ADTRAN

ADTRAN AHT1U User manual

ADTRAN ATLAS 800 Series Module QUAD E1 User manual

ADTRAN

ADTRAN ATLAS 800 Series Module QUAD E1 User manual

ADTRAN U-BR1TE User manual

ADTRAN

ADTRAN U-BR1TE User manual

ADTRAN 850 DSX-1 User manual

ADTRAN

ADTRAN 850 DSX-1 User manual

ADTRAN OPTI-6100 LMX User manual

ADTRAN

ADTRAN OPTI-6100 LMX User manual

ADTRAN NIU3 Instruction Manual

ADTRAN

ADTRAN NIU3 Instruction Manual

Popular Network Card manuals by other brands

Belkin F6D301 user manual

Belkin

Belkin F6D301 user manual

FirstComm OBiWiFi5G Setup guide

FirstComm

FirstComm OBiWiFi5G Setup guide

TRENDnet TU2-ETG user guide

TRENDnet

TRENDnet TU2-ETG user guide

YASKAWA SI-EN3 Technical manual

YASKAWA

YASKAWA SI-EN3 Technical manual

Paradyne BitStorm 2600 IP DSLAM installation guide

Paradyne

Paradyne BitStorm 2600 IP DSLAM installation guide

Belkin F5D7050 user manual

Belkin

Belkin F5D7050 user manual

3Com EtherLink 3C509B quick guide

3Com

3Com EtherLink 3C509B quick guide

TRENDnet TEG-PCITX user guide

TRENDnet

TRENDnet TEG-PCITX user guide

Cisco MC16E installation guide

Cisco

Cisco MC16E installation guide

Delta Electronics Braking Modules VFDB Series instruction sheet

Delta Electronics

Delta Electronics Braking Modules VFDB Series instruction sheet

TwinMOS Booming user manual

TwinMOS

TwinMOS Booming user manual

Dialogic Media Board DM/V1200BTEPEQ installation guide

Dialogic

Dialogic Media Board DM/V1200BTEPEQ installation guide

Buffalo AirStation WLI-PCM-L11GP user manual

Buffalo

Buffalo AirStation WLI-PCM-L11GP user manual

TRENDnet TEG-PCITXR user guide

TRENDnet

TRENDnet TEG-PCITXR user guide

Sun Microsystems Interface Adapter user guide

Sun Microsystems

Sun Microsystems Interface Adapter user guide

D-Link DHP?P309AV Setup guide

D-Link

D-Link DHP?P309AV Setup guide

Extollo LANPlug 2000 Product guide

Extollo

Extollo LANPlug 2000 Product guide

LG-Ericsson PCI-1020 user manual

LG-Ericsson

LG-Ericsson PCI-1020 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

HRE T200
HRE / T200
CLEI: T1R6DTTD_ _
JOBAID
STATUS LEDs
PWR ●●OFF No span power is present
●GREEN Span power is present
NET LP1/NET LP2 ●●OFF No sync with the HTU-C on NET LP1/LP2
●GREEN Sync with good signal quality
●YELLOW Sync with marginal signal quality
●RED Sync with poor signal quality
CUST LP1/CUST LP2 ●●OFF No sync with the HTU-R on CUST LP1/LP2
●GREEN Sync with good signal quality
●YELLOW Sync with marginal signal quality
●RED Sync with poor signal quality
LL/RL ●YELLOW HRE network loopback is active
●GREEN HRE customer loopback is active
LOOPBACK
■During a loopback toward the network all NET and CUST LP1/LP2
LEDs remain solid. LBK LED is solid yellow.
■During a loopback toward the customer all NET and CUST LP1/LP2
LEDs remain solid. LBK LED is GREEN. The DSI LED on the HTU-R
flashes during this loopback.
CARD EDGE PIN ASSIGNMENTS
1 Chassis Ground
5 HDSL Loop 1 Tip (Customer)
7 HDSL Loop 1 Tip (Network)
11 Chassis Ground
13 HDSL Loop 1 Ring (Network)
15 HDSL Loop 1 Ring (Customer)
17 –48 V Return (Ground)
27 Chassis Ground
41 HDSL Loop 2 Tip (Network)
47 HDSL Loop 2 Ring (Network)
49 HDSL Loop 2 Ring (Customer)
55 HDSL Loop 2 Tip (Customer)
WIRING DIAGRAM FOR HDSL TECHNOLOGY
CP1 Circuit Pack Cable / Color For HDSL / HRE
/Pin # Wire Housing T400 / T200
5-15 Blue White Customer, Loop 1
7-13 Orange Red Network, Loop 1
41-47 Orange White Network, Loop 2
49-55 Green Red Customer, Loop 2
CP2
5-15 Green White Customer, Loop 1
7-13 Brown Red Network, Loop 1
41-47 Brown White Network, Loop 2
49-55 Slate Red Customer, Loop 2
CP3
5-15 Blue Red Customer, Loop 1
7-13 Blue Black Network, Loop 1
41-47 Orange Black Network, Loop 2
49-55 Blue Yellow Customer, Loop 2
CP4
5-15 Green Black Customer, Loop 1
7-13 Yellow Orange Network, Loop 1
41-47 Brown Black Network, Loop 2
49-55 Slate Black Customer, Loop 2
Order Wires Slate White
Spare Pair Green Yellow
Note: Wiring information is for housing 1150043L1, L2 (L1– aircore cable, L2– gel-filled core cable).
ADTRAN T200/T400 REPEATER HOUSINGS
Part # Description HRE Capacity CLEI CODE* Material
1150090L1 24-slot Pad Mount Gel Stub 24 T1MJ4U0MRA Aluminum
1150090L2 24-slot Pole Mount Gel Stub 24 T1MJ5UOMRA Aluminum
1150043L1 4-slot Air Stub 4 DDMOAD01MA Stainless Steel Dome
1150043L2 4-slot Gel Stub 4 DDMOBD01MA Stainless Steel Dome
61246041L1-22A
0002
■ For a complete Installation and Maintenance Practice faxback: (877) 457-5007, Document 453. Please have your fax number available. ■
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.923.8726
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61246041L1-22A
T200 HRE TURN-UP GUIDE
LOOP BACK
LOOP THRU
SHORT
OPEN
LOOP 1
LOOP 2
P7 T
P13 R
P41 T
P47 R
TP5
R P15
T P55
R P49
CUST
NET
LOOP 1
LOOP 2
P7 T
P13 R
P41 T
P47 R
TP5
R P15
T P55
R P49
CUST
NET
LOOP 1
LOOP 2
P7 T
P13 R
P41 T
P47 R
TP5
R P15
T P55
R P49
CUST
NET
LOOP 1
LOOP 2
P7 P5
T
NET CUST
P13 P15
R
T
R
LOOP
BACK
LOOP
THRU
SHORT
OPEN
SW1
P41 P55
T
NET CUST
P47 P49
R
T
R
P17 P1/P11
FRM
GND
-48
RET
P35
-48V
1996 5244.065-1D
c
LOOP 1
LOOP 2
P7 T
P13 R
P41 T
P47 R
TP5
R P15
T P55
R P49
CUST
NET
INSERTING THE TAC
For test access using the TAC, insert the TAC into the repeater housing as follows.
Hold card with the index finger through the finger hole viewing the edge of the card
so that SW1 is facing to the right. The edge of the card being viewed corresponds to
the faceplate of the HRE. Insert card into the slot with the same orientation as the
T200 HRE. Test Access Card (TAC), part number 1244065L1, or Test Access Module
(TAM), part number 1245065L1, can be used for testing the slot.
TESTING THE CO PAIRS
LOOPBACK
1. To loopback the circuit put SW1 in the LOOPBACK position. This loops the circuit
back to the CO and to the field.
LOOPTHRU
2. To loopthru the CO pairs to the field pairs put SW1 in the LOOPTHRU position.
This bridges the circuit pairs.
SHORT
3. To short the CO pairs put SW1 in the SHORT position. This connects transmit to
receive on each loop.
OPEN
4. To open the circuit put SW1 in the OPEN position. This allows for a voltage
measurement across pairs.
AVAILABLE ACCESS
Label Description
P7 LOOP1 Transmit towards NET
P13 LOOP 1 Receive towards CUST
P5 LOOP 1 Transmit towards CUST
P15 LOOP 1 Receive towards CUST
P41 LOOP 2 Transmit towards NET
P47 LOOP 2 Receive towards NET
P55 LOOP 2 Transmit towards CUST
P49 LOOP 2 Receive towards CUST
P17 –48RET
P1 Frame Ground
P11 Frame Ground
P35 –48 volts
WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s
order for use in the U.S. is ten (10) years. For a complete faxback copy of ADTRAN’s U.S. and
Canada Carrier Networks Equipment Warranty: (877) 457-5007, Document 414.
COMPLIANCE
This product complies with UL 1950, third edition. It is
intended for installation in restricted access locations only and
in equipment with a Type “B”’ or “E” installation code. Ensure
chassis ground is properly connected.
Code Input Output
Power Code (PC) C C
Telecommunication Code (TC) X X
Installation Code (IC) A –