manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Network Hardware
  8. •
  9. ADTRAN 1442703PG2 User manual

ADTRAN 1442703PG2 User manual

jobAid
DESCRIPTION
TheOC‐12SmallForm‐FactorPluggableCWDM1491nm(SFP
OC‐12)plugsintoADTRANOC‐12equipmentdesignedtoaccept
SmallForm‐factorPluggables(SFPs).
Installedintoanappropriatehostunit,theSFPOC‐12providesan
OC‐12CWDMinterfacetothesupportingsystem.
NOTE
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheSFPOC‐12:
♦SONETOC‐12compatible(622.08Mb/s)1491nm,
longreach,single‐mode,2‐fiberoperation
♦80kmmaximumopticalspan
CAUTION
!
Duetocompliancecertificationrequirements,useonlySFPs
suppliedbyADTRANwiththehostmodule.ADTRANcannot
certifysystemintegritywithotherSFPs.
SPECIFICATIONS
♦OpticalSpecifications:
◊Opticaltransmitlevel:–3dBmto+5dBm
◊Opticalreceivelevel:–28dBmto–8dBm
◊Powerpenalty:–1dB
◊Opticalbudget:24(±1)dBm
◊Minimumspanattenuation:13dB
◊Opticalconnectors:LC
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–40°Cto+65°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto95%,noncondensing
OC-12 Small Form-Factor Pluggable
CWDM 1491 nm
INSTALLATION
ToinstalltheSFPOC‐12intoanappropriatemodule,complete
thefollowingsteps:
1. InspecttheSFPOC‐12.Ifdamaged,fileaclaimwiththecar‐
rierandthencontactADTRANCustomerSupport.
CAUTION
!
DonotremovetheprotectiveendcapfromtheSFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheSFPOC‐12intotheSFPcageonthemodule.
Ensurethatthemanufacturer’slabelontheSFPisfacing
upwardforcorrectinstallation.
3. SlidetheSFPOC‐12allthewayintothereceptacleuntil
thereisanaudible“click”.
NOTE
ThelatchontheSFPisusedtoremovetheSFPfromthecageon
thecircuitcard.
PROVISIONING
The SFPOC‐12 is not directly provisionable. To provision the
SFPOC‐12, access the menu system of the host module.
Refer to the “Provisioning” section of the Job Aid or I&M
provided with the host module for provisioning details.
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccomponents.Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
workingonmodules,alwaysplacethemonanapproved
antistaticmatthatiselectricallygrounded.
TheSFPOC‐12isNRTLListedtotheapplicableULstandards.
TheSFPOC‐12meetsorexceedsalltheapplicablerequirements
ofNEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSIEN
300368.
TheSFPOC‐12isintendedfordeploymentinCentralOfficetype
facilities,EEEs,EECs,andlocationswheretheNECapplies(for
example,CustomerPremises).TheSFPOC‐12istobeinstalledin
ADTRANproductsinRestrictedAccessLocationsonly,and
installedbytrainedservicepersonnel.
CLEI: SOOTAKNJ_ _
Product P/N: 1442703PG2
Issue Date: December 2010
Document P/N: 61442703PG2-22B
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442703PG2-22B*
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CAUTION
C
TheSFPOC‐12containsaClass1laserthatcomplieswiththe
LaserSafetyrequirementsofFDA21CFR1040.10and1040.11,
andEN60825‐1,and‐2.TheSFPOC‐12isNRTLListedandCB
CertifiedtoallapplicableAmericanandEuropeansafety
standards.
CAUTION
!
♦ PerGR‐1089‐CORESection9,theSFPOC‐12 does not have
an internal DC connection between battery return and
frame ground.
♦ TheADTRANsystemthattheSFPOC‐12isbeingdeployedin
isdesignedandintendedforinstallationaspartofaCommon
BondingNetwork(CBN),orIsolatedBondingnetwork(IBN).
♦ TheSFPOC‐12canbeinstalledinaDC‐I(isolated)orDC‐C
(common)configuration.Forinstallationswhereothercards
orthehostsystemhaveinternalconnectionsbetweenbattery
returnandframeground,thesystemwouldbeintendedfor
deploymentonlyinaDC‐Cconfiguration.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheSFPOC‐12isproperlygroundedviathe
backplaneconnector.
NOTE
♦ TheOC‐12port(s)areopticalandthereforearenotclassifiedas
anytypeofportasdefinedinAppendixBofGR‐1089‐CORE
Issue5.
♦ ThisSFPOC‐12iscompliantwithSFF‐8472“Digital
DiagnosticsMonitoringInterfaceforOpticalTransceivers,”
Revision9.3.
♦ ThisSFPOC‐12iscompliantwiththeSmallForm‐Factor
Pluggable(SFP)Multi‐SourceAgreement(MSA).
♦ ThisproductisdesignedtobedeployedinGR‐3108‐CORE
environmentclass1or2asdefinedinGR‐3108‐COREissue2.
TheSFPOC‐12isdesignedtomeetthefollowingenvironmental
classes:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Thisproducthasbeenevlauatedtointernationalsafetystandards
EN60950‐1,AS/NZS60950.1,andIEC60950‐1.Thisproduct
meetstherequirementsforCEmarkingundertheEMCDirective
andLowVoltageDirective.Standardsusedtodemonstrate
ComplianceareEN300386andEN60950.
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
ThisproductmeetsEURoHSDirective2002/95/ECand/orappli‐
cableexemptions.Refertowww.adtran.comforfurtherinfor‐
mationonRoHS/WEEE.

This manual suits for next models

1

Other ADTRAN Network Hardware manuals

ADTRAN NETVANTA UNIFIED COMMUNICATIONS DEMO KIT User manual

ADTRAN

ADTRAN NETVANTA UNIFIED COMMUNICATIONS DEMO KIT User manual

ADTRAN DS3 NIU3 PM Instruction Manual

ADTRAN

ADTRAN DS3 NIU3 PM Instruction Manual

ADTRAN IQ 310 User manual

ADTRAN

ADTRAN IQ 310 User manual

ADTRAN Total Access 372 Product manual

ADTRAN

ADTRAN Total Access 372 Product manual

ADTRAN jobAid NetVanta 838T User manual

ADTRAN

ADTRAN jobAid NetVanta 838T User manual

ADTRAN NetVanta 2000 Series User manual

ADTRAN

ADTRAN NetVanta 2000 Series User manual

ADTRAN Express 6500 Series Instruction Manual

ADTRAN

ADTRAN Express 6500 Series Instruction Manual

ADTRAN SFP+ User manual

ADTRAN

ADTRAN SFP+ User manual

ADTRAN Network Interface Module T1/FT1 User manual

ADTRAN

ADTRAN Network Interface Module T1/FT1 User manual

ADTRAN Total Access 604 User guide

ADTRAN

ADTRAN Total Access 604 User guide

ADTRAN NetVanta Series User manual

ADTRAN

ADTRAN NetVanta Series User manual

ADTRAN BR10 User manual

ADTRAN

ADTRAN BR10 User manual

ADTRAN U-BR1TE Maintenance and service guide

ADTRAN

ADTRAN U-BR1TE Maintenance and service guide

ADTRAN DSU III ARdc User manual

ADTRAN

ADTRAN DSU III ARdc User manual

ADTRAN Total Access 372E User manual

ADTRAN

ADTRAN Total Access 372E User manual

ADTRAN 1202803L1 User manual

ADTRAN

ADTRAN 1202803L1 User manual

ADTRAN Total Access DSLAM Octal SHDSL User manual

ADTRAN

ADTRAN Total Access DSLAM Octal SHDSL User manual

ADTRAN Total Access 324E User manual

ADTRAN

ADTRAN Total Access 324E User manual

ADTRAN OC-12 User manual

ADTRAN

ADTRAN OC-12 User manual

ADTRAN DSU IQ User manual

ADTRAN

ADTRAN DSU IQ User manual

ADTRAN NetVanta T1/FT1 + DSX-1 User manual

ADTRAN

ADTRAN NetVanta T1/FT1 + DSX-1 User manual

ADTRAN Total Access 1100F User manual

ADTRAN

ADTRAN Total Access 1100F User manual

ADTRAN NT1 ACE User manual

ADTRAN

ADTRAN NT1 ACE User manual

ADTRAN Total Access 301 User manual

ADTRAN

ADTRAN Total Access 301 User manual

Popular Network Hardware manuals by other brands

ICP DAS USA ZT-20 IOG Series quick start

ICP DAS USA

ICP DAS USA ZT-20 IOG Series quick start

Avocent MergePoint 5200 Specification sheet

Avocent

Avocent MergePoint 5200 Specification sheet

Russound BGB2 instruction manual

Russound

Russound BGB2 instruction manual

Siemens 2000592-001 user manual

Siemens

Siemens 2000592-001 user manual

TCAM TMAS TMN-10 user manual

TCAM

TCAM TMAS TMN-10 user manual

Concept Pro VHDIPL-V3 Series user manual

Concept Pro

Concept Pro VHDIPL-V3 Series user manual

Juniper SSR1300 Hardware guide

Juniper

Juniper SSR1300 Hardware guide

Matrix Switch Corporation MSC-HD88DES product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-HD88DES product manual

PMC-Sierra PM5354 Features

PMC-Sierra

PMC-Sierra PM5354 Features

Extreme Networks ExtremeCloud Appliance Series user guide

Extreme Networks

Extreme Networks ExtremeCloud Appliance Series user guide

Alcatel-Lucent vitalqip 5000 quick start guide

Alcatel-Lucent

Alcatel-Lucent vitalqip 5000 quick start guide

Vista Viper quick start guide

Vista

Vista Viper quick start guide

Tektronix 7B87 instruction manual

Tektronix

Tektronix 7B87 instruction manual

Tyco EV 4UA Hybrid Series quick start guide

Tyco

Tyco EV 4UA Hybrid Series quick start guide

Showgear RCA-FSM-18 user manual

Showgear

Showgear RCA-FSM-18 user manual

AvaLAN AW5802mTR-EVAL user manual

AvaLAN

AvaLAN AW5802mTR-EVAL user manual

Panasonic Transistors 2SC4805G Specifications

Panasonic

Panasonic Transistors 2SC4805G Specifications

Patton electronics 2500RC user manual

Patton electronics

Patton electronics 2500RC user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.