manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Network Hardware
  8. •
  9. ADTRAN 1442703PG2 User manual

ADTRAN 1442703PG2 User manual

This manual suits for next models

1

Other ADTRAN Network Hardware manuals

ADTRAN 6540 Product manual

ADTRAN

ADTRAN 6540 Product manual

ADTRAN TRACER 4106 Plan User guide

ADTRAN

ADTRAN TRACER 4106 Plan User guide

ADTRAN OSU 300 User manual

ADTRAN

ADTRAN OSU 300 User manual

ADTRAN HTU Nx64 User manual

ADTRAN

ADTRAN HTU Nx64 User manual

ADTRAN DSU IQ User manual

ADTRAN

ADTRAN DSU IQ User manual

ADTRAN 3.125 Gigabit Ethernet User manual

ADTRAN

ADTRAN 3.125 Gigabit Ethernet User manual

ADTRAN ESU 120e User manual

ADTRAN

ADTRAN ESU 120e User manual

ADTRAN 602 User manual

ADTRAN

ADTRAN 602 User manual

ADTRAN TRACER 4102 User guide

ADTRAN

ADTRAN TRACER 4102 User guide

ADTRAN NetVanta E1/FE1 Network Interface Module User manual

ADTRAN

ADTRAN NetVanta E1/FE1 Network Interface Module User manual

ADTRAN 1442351G7 User manual

ADTRAN

ADTRAN 1442351G7 User manual

ADTRAN D4 TRI-C DP User manual

ADTRAN

ADTRAN D4 TRI-C DP User manual

ADTRAN Total Access 372E User manual

ADTRAN

ADTRAN Total Access 372E User manual

ADTRAN NetVanta 6355 PoE User manual

ADTRAN

ADTRAN NetVanta 6355 PoE User manual

ADTRAN T1 CSU ACE User manual

ADTRAN

ADTRAN T1 CSU ACE User manual

ADTRAN BR1 User manual

ADTRAN

ADTRAN BR1 User manual

ADTRAN OSU 300 User manual

ADTRAN

ADTRAN OSU 300 User manual

ADTRAN Total Access 362R Product manual

ADTRAN

ADTRAN Total Access 362R Product manual

ADTRAN TSU LT User manual

ADTRAN

ADTRAN TSU LT User manual

ADTRAN HD-10 BRI MUX Instruction Manual

ADTRAN

ADTRAN HD-10 BRI MUX Instruction Manual

ADTRAN NetVanta T1/FT1 + DSX-1 User manual

ADTRAN

ADTRAN NetVanta T1/FT1 + DSX-1 User manual

ADTRAN T200 HTU-R User manual

ADTRAN

ADTRAN T200 HTU-R User manual

ADTRAN Express 3000 User manual

ADTRAN

ADTRAN Express 3000 User manual

ADTRAN T1 Nx64 HTU-R Instruction Manual

ADTRAN

ADTRAN T1 Nx64 HTU-R Instruction Manual

Popular Network Hardware manuals by other brands

socomec SNMP Card II quick start guide

socomec

socomec SNMP Card II quick start guide

NVR SYSTEMS 4-CH user manual

NVR SYSTEMS

NVR SYSTEMS 4-CH user manual

Draytek VigorSwitch G1240 quick start guide

Draytek

Draytek VigorSwitch G1240 quick start guide

Westermo TD-34 LV installation manual

Westermo

Westermo TD-34 LV installation manual

LaCie Network Space MAX Quick install guide

LaCie

LaCie Network Space MAX Quick install guide

ZoneVu ZSI-450-IP Installation guide & user manual

ZoneVu

ZoneVu ZSI-450-IP Installation guide & user manual

QNAP Turbo NAS Application notes

QNAP

QNAP Turbo NAS Application notes

OpenEye MV Series quick start guide

OpenEye

OpenEye MV Series quick start guide

Huawei SmartAX MT880a quick start guide

Huawei

Huawei SmartAX MT880a quick start guide

Proxim Tsunami QuickBridge 2454-R installation guide

Proxim

Proxim Tsunami QuickBridge 2454-R installation guide

Bay Networks CLAM quick start guide

Bay Networks

Bay Networks CLAM quick start guide

Innodisk SATADOM-SH 3SE Series manual

Innodisk

Innodisk SATADOM-SH 3SE Series manual

Cisco CGR 1000 Series Getting connected guide

Cisco

Cisco CGR 1000 Series Getting connected guide

Matrix Switch Corporation MSC-HD161DEL product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-HD161DEL product manual

National Instruments NI 653x user manual

National Instruments

National Instruments NI 653x user manual

B&B Electronics ZXT9-IO-222R2 product manual

B&B Electronics

B&B Electronics ZXT9-IO-222R2 product manual

Yudor YDS-16 user manual

Yudor

Yudor YDS-16 user manual

D-Link ShareCenter DNS-320L datasheet

D-Link

D-Link ShareCenter DNS-320L datasheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

jobAid
DESCRIPTION
TheOC‐12SmallForm‐FactorPluggableCWDM1491nm(SFP
OC‐12)plugsintoADTRANOC‐12equipmentdesignedtoaccept
SmallForm‐factorPluggables(SFPs).
Installedintoanappropriatehostunit,theSFPOC‐12providesan
OC‐12CWDMinterfacetothesupportingsystem.
NOTE
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheSFPOC‐12:
♦SONETOC‐12compatible(622.08Mb/s)1491nm,
longreach,single‐mode,2‐fiberoperation
♦80kmmaximumopticalspan
CAUTION
!
Duetocompliancecertificationrequirements,useonlySFPs
suppliedbyADTRANwiththehostmodule.ADTRANcannot
certifysystemintegritywithotherSFPs.
SPECIFICATIONS
♦OpticalSpecifications:
◊Opticaltransmitlevel:–3dBmto+5dBm
◊Opticalreceivelevel:–28dBmto–8dBm
◊Powerpenalty:–1dB
◊Opticalbudget:24(±1)dBm
◊Minimumspanattenuation:13dB
◊Opticalconnectors:LC
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–40°Cto+65°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto95%,noncondensing
OC-12 Small Form-Factor Pluggable
CWDM 1491 nm
INSTALLATION
ToinstalltheSFPOC‐12intoanappropriatemodule,complete
thefollowingsteps:
1. InspecttheSFPOC‐12.Ifdamaged,fileaclaimwiththecar‐
rierandthencontactADTRANCustomerSupport.
CAUTION
!
DonotremovetheprotectiveendcapfromtheSFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheSFPOC‐12intotheSFPcageonthemodule.
Ensurethatthemanufacturer’slabelontheSFPisfacing
upwardforcorrectinstallation.
3. SlidetheSFPOC‐12allthewayintothereceptacleuntil
thereisanaudible“click”.
NOTE
ThelatchontheSFPisusedtoremovetheSFPfromthecageon
thecircuitcard.
PROVISIONING
The SFPOC‐12 is not directly provisionable. To provision the
SFPOC‐12, access the menu system of the host module.
Refer to the “Provisioning” section of the Job Aid or I&M
provided with the host module for provisioning details.
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccomponents.Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
workingonmodules,alwaysplacethemonanapproved
antistaticmatthatiselectricallygrounded.
TheSFPOC‐12isNRTLListedtotheapplicableULstandards.
TheSFPOC‐12meetsorexceedsalltheapplicablerequirements
ofNEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSIEN
300368.
TheSFPOC‐12isintendedfordeploymentinCentralOfficetype
facilities,EEEs,EECs,andlocationswheretheNECapplies(for
example,CustomerPremises).TheSFPOC‐12istobeinstalledin
ADTRANproductsinRestrictedAccessLocationsonly,and
installedbytrainedservicepersonnel.
CLEI: SOOTAKNJ_ _
Product P/N: 1442703PG2
Issue Date: December 2010
Document P/N: 61442703PG2-22B
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442703PG2-22B*
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CAUTION
C
TheSFPOC‐12containsaClass1laserthatcomplieswiththe
LaserSafetyrequirementsofFDA21CFR1040.10and1040.11,
andEN60825‐1,and‐2.TheSFPOC‐12isNRTLListedandCB
CertifiedtoallapplicableAmericanandEuropeansafety
standards.
CAUTION
!
♦ PerGR‐1089‐CORESection9,theSFPOC‐12 does not have
an internal DC connection between battery return and
frame ground.
♦ TheADTRANsystemthattheSFPOC‐12isbeingdeployedin
isdesignedandintendedforinstallationaspartofaCommon
BondingNetwork(CBN),orIsolatedBondingnetwork(IBN).
♦ TheSFPOC‐12canbeinstalledinaDC‐I(isolated)orDC‐C
(common)configuration.Forinstallationswhereothercards
orthehostsystemhaveinternalconnectionsbetweenbattery
returnandframeground,thesystemwouldbeintendedfor
deploymentonlyinaDC‐Cconfiguration.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheSFPOC‐12isproperlygroundedviathe
backplaneconnector.
NOTE
♦ TheOC‐12port(s)areopticalandthereforearenotclassifiedas
anytypeofportasdefinedinAppendixBofGR‐1089‐CORE
Issue5.
♦ ThisSFPOC‐12iscompliantwithSFF‐8472“Digital
DiagnosticsMonitoringInterfaceforOpticalTransceivers,”
Revision9.3.
♦ ThisSFPOC‐12iscompliantwiththeSmallForm‐Factor
Pluggable(SFP)Multi‐SourceAgreement(MSA).
♦ ThisproductisdesignedtobedeployedinGR‐3108‐CORE
environmentclass1or2asdefinedinGR‐3108‐COREissue2.
TheSFPOC‐12isdesignedtomeetthefollowingenvironmental
classes:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Thisproducthasbeenevlauatedtointernationalsafetystandards
EN60950‐1,AS/NZS60950.1,andIEC60950‐1.Thisproduct
meetstherequirementsforCEmarkingundertheEMCDirective
andLowVoltageDirective.Standardsusedtodemonstrate
ComplianceareEN300386andEN60950.
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
ThisproductmeetsEURoHSDirective2002/95/ECand/orappli‐
cableexemptions.Refertowww.adtran.comforfurtherinfor‐
mationonRoHS/WEEE.