manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Network Hardware
  8. •
  9. ADTRAN 1442704PG1 User manual

ADTRAN 1442704PG1 User manual

Other ADTRAN Network Hardware manuals

ADTRAN NetVanta Serial Dial Backup Interface Module (DIM)... User manual

ADTRAN

ADTRAN NetVanta Serial Dial Backup Interface Module (DIM)... User manual

ADTRAN Total Access 480 User manual

ADTRAN

ADTRAN Total Access 480 User manual

ADTRAN Total Access 300 Series User manual

ADTRAN

ADTRAN Total Access 300 Series User manual

ADTRAN ACT 1900 User manual

ADTRAN

ADTRAN ACT 1900 User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN QDFR Unit Instruction Manual

ADTRAN

ADTRAN QDFR Unit Instruction Manual

ADTRAN NetVanta 1531 Series Manual

ADTRAN

ADTRAN NetVanta 1531 Series Manual

ADTRAN ATLAS 800 Series Module QUAD E1 User guide

ADTRAN

ADTRAN ATLAS 800 Series Module QUAD E1 User guide

ADTRAN DSU IV ESP User manual

ADTRAN

ADTRAN DSU IV ESP User manual

ADTRAN T3SU 300 User manual

ADTRAN

ADTRAN T3SU 300 User manual

ADTRAN SFP+ User manual

ADTRAN

ADTRAN SFP+ User manual

ADTRAN IQ Probe 1200214L1 User manual

ADTRAN

ADTRAN IQ Probe 1200214L1 User manual

ADTRAN JOBAID T200 IDSL User manual

ADTRAN

ADTRAN JOBAID T200 IDSL User manual

ADTRAN NetVanta E1/FE1 + G.703 Network Interface... User manual

ADTRAN

ADTRAN NetVanta E1/FE1 + G.703 Network Interface... User manual

ADTRAN 4202023L5 User manual

ADTRAN

ADTRAN 4202023L5 User manual

ADTRAN 3192 User manual

ADTRAN

ADTRAN 3192 User manual

ADTRAN 4200990G1 Manual

ADTRAN

ADTRAN 4200990G1 Manual

ADTRAN 1203060L1 User manual

ADTRAN

ADTRAN 1203060L1 User manual

ADTRAN NetVanta 2000 Series User manual

ADTRAN

ADTRAN NetVanta 2000 Series User manual

ADTRAN 1442390G1 User manual

ADTRAN

ADTRAN 1442390G1 User manual

ADTRAN TOTAL ACCESS 600R User manual

ADTRAN

ADTRAN TOTAL ACCESS 600R User manual

ADTRAN DSU 5600 User manual

ADTRAN

ADTRAN DSU 5600 User manual

ADTRAN OSU 300 User manual

ADTRAN

ADTRAN OSU 300 User manual

ADTRAN HDSL4 Instruction Manual

ADTRAN

ADTRAN HDSL4 Instruction Manual

Popular Network Hardware manuals by other brands

socomec SNMP Card II quick start guide

socomec

socomec SNMP Card II quick start guide

NVR SYSTEMS 4-CH user manual

NVR SYSTEMS

NVR SYSTEMS 4-CH user manual

Draytek VigorSwitch G1240 quick start guide

Draytek

Draytek VigorSwitch G1240 quick start guide

Westermo TD-34 LV installation manual

Westermo

Westermo TD-34 LV installation manual

LaCie Network Space MAX Quick install guide

LaCie

LaCie Network Space MAX Quick install guide

ZoneVu ZSI-450-IP Installation guide & user manual

ZoneVu

ZoneVu ZSI-450-IP Installation guide & user manual

QNAP Turbo NAS Application notes

QNAP

QNAP Turbo NAS Application notes

OpenEye MV Series quick start guide

OpenEye

OpenEye MV Series quick start guide

Huawei SmartAX MT880a quick start guide

Huawei

Huawei SmartAX MT880a quick start guide

Proxim Tsunami QuickBridge 2454-R installation guide

Proxim

Proxim Tsunami QuickBridge 2454-R installation guide

Bay Networks CLAM quick start guide

Bay Networks

Bay Networks CLAM quick start guide

Innodisk SATADOM-SH 3SE Series manual

Innodisk

Innodisk SATADOM-SH 3SE Series manual

Cisco CGR 1000 Series Getting connected guide

Cisco

Cisco CGR 1000 Series Getting connected guide

Matrix Switch Corporation MSC-HD161DEL product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-HD161DEL product manual

National Instruments NI 653x user manual

National Instruments

National Instruments NI 653x user manual

B&B Electronics ZXT9-IO-222R2 product manual

B&B Electronics

B&B Electronics ZXT9-IO-222R2 product manual

Yudor YDS-16 user manual

Yudor

Yudor YDS-16 user manual

D-Link ShareCenter DNS-320L datasheet

D-Link

D-Link ShareCenter DNS-320L datasheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

jobAid
DESCRIPTION
TheSmallForm‐FactorPluggableOC‐12Bidirectional1310/1550
nm(BidirectionalSFP)plugsintoADTRANequipmentdesigned
toacceptSmallForm‐factorPluggables(SFPs).Installedintoan
appropriatehostunit,theBidirectionalSFPprovidesanOC‐12
interfacetothesupportingsystem.
NOTE
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheBidirectionalSFP:
♦SONETOC‐12compatible(622Mb/s),single‐fiberoperation
♦15kmmaximumopticalspan
CAUTION
!
Duetocompliancecertificationrequirements,onlySFPssupplied
byADTRANaretobeusedwiththehostmodule.ADTRAN
cannotcertifysystemintegritywithotherSFPs.
SPECIFICATIONS
♦OpticalSpecifications:
◊Opticaltransmitlevel:–8dBmto–15dBm
◊Opticalreceivelevel:–8dBmto–28dBm
◊TransmitWavelength:1310nm
◊ReceiveWavelength:1550nm
◊Opticalbudget:12(±1)dBm
◊Opticalconnectors:LC
Small Form-Factor Pluggable OC-12
Bidirectional 1310/1550 nm
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–40°Cto+65°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto95%,noncondensing
INSTALLATION
ToinstalltheBidirectionalSFPintoanappropriatemodule,
completethefollowingsteps:
1. InspecttheBidirectionalSFP.Ifdamaged,fileaclaimwith
thecarrierandthencontactADTRANCustomerSupport.
CAUTION
!
DonotremovetheprotectiveendcapfromtheSFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheBidirectionalSFPintotheSFPcageonthemodule.
Ensurethatthemanufacturer’slabelontheSFPisfacing
upwardforcorrectinstallation.
3. SlidetheBidirectionalSFPallthewayintothereceptacle
untilthereisanaudible“click”.
NOTE
ThelatchontheSFPisusedtoremovetheSFPfromthecageon
thecircuitcard.
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
♦ ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewrist
straptopreventdamagetoelectroniccomponents.Place
modulesinantistaticpackingmaterialwhentransportingor
storing.Whenworkingonmodules,alwaysplacethemonan
approvedantistaticmatthatiselectricallygrounded.
♦ TheSFPmeetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSIEN
300368.TheBidirectionalSFPisintendedfordeploymentin
CentralOfficetypefacilities,EEEs,EECs,andlocationswhere
theNECapplies(forexample,CustomerPremises).TheSFPis
tobeinstalledinADTRANproductsinRestrictedAccess
Locationsonly,andinstalledbytrainedservicepersonnel.
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CLEI: S00TALAJ__
Product P/N: 1442704PG1
Issue Date: October 2010
Document P/N: 61442704PG1-22A
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442704PG1-22A*
CAUTION
!
♦ PerGR‐1089‐COREtheADTRANsystemthattheSFPisbeing
deployedinisdesignedandintendedforinstallationaspartof
aCommonBondingNetwork(CBN).TheADTRANsystem
thattheSFPisbeingdeployedinisnotdesignednorintended
forinstallationaspartofanIsolatedBondingNetwork(IBN).
♦ PerGR‐1089‐CORESection9,theBidirectionalSFPdoesnot
haveaninternalDCconnectionbetweenbatteryreturnand
frameground.TheBidirectionalSFPcanbeinstalledinaDC‐I
(isolated)orDC‐C(common)installation.Forinstallations
whereothercardsorthehostsystemhaveinternalconnections
betweenbatteryreturnandframeground,thesystemwould
beintendedfordeploymentonlyinaDC‐Cinstallation.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheBidirectionalSFPisproperlygroundedviathe
backplaneconnector.
CAUTION
C
TheSmallForm‐FactorPluggableOC‐12Bidirectional1310/1550
nmisaClass1LaserProductandcomplieswiththeLaserSafety
requirementsofFDA21CFR1040.11,EN60825‐1,andEN60825‐2.
TheBidirectionalSFPisNRTLListedandCBCertifiedtoall
applicableAmericanandEuropeansafetystandards.
NOTE
TheGigabitEthernetport(s)areopticalandthereforearenot
classifiedasanytypeofportasdefinedinAppendixBofGR‐
1089‐COREIssue5.
TheBidirectionalSFPisdesignedtomeetthefollowingenviron‐
mentalclasses:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
TheSmallForm‐FactorPluggableOC‐12Bidirectional1310/1550
nmmeetsEURoHSDirective2002/95/ECand/orapplicable
exemptions.Refertowww.adtran.comforfurtherinformationon
RoHS/WEEE.
NOTE
♦ ThisBidirectionalSFPiscompliantwithSFF‐8472“Digital
DiagnosticsMonitoringInterfaceforOpticalTransceivers,”
Revision9.3.
♦ ThisBidirectionalSFPiscompliantwiththeSmallForm‐Factor
Pluggable(SFP)Multi‐SourceAgreement(MSA).
♦ ThisBidirectionalSFPisdesignedtobedeployedinGR‐3108‐
COREenvironmentalclass1or2asdefinedinGR‐3108‐CORE
Issue2.