jobAid
DESCRIPTION
The OC-3 Intermediate Reach (OC-3 SFP) plugs into ADTRAN
OC-3 modules designed to accept Small Form-Factor Pluggables
(SFPs). Installed into an appropriate host module, the OC-3 SFP
provides an OC-3 interface to the supporting system.
NOTE
To ensure compatibility, refer to the documentation provided
with the host module.
The following features are supported on the OC-3 SFP:
SONET OC-3 (155.52 Mb/s) 1310 nm, intermediate-reach (IR-
1), single-mode, 2-fiber operation
15 km maximum optical span
Digital diagnostics available through the menus of the host
module
CAUTION
!
Due to compliance certification requirements, only SFPs supplied
by ADTRAN are to be used with the host module. ADTRAN
cannot certify system integrity with other SFPs.
Operational Specifications
Optical Specifications:
oTransmit level: –15 dBm to –8 dBm
oReceive level: –28 dBm to –8 dBm
oPower penalty: 1 dB
oOptical budget: 12 dB
oOptical connectors: LC
oMaximum optical span: 15 km
oMinimum span attenuation: 0 dB
Extended Environmental Support:
oOperational temperature range: –40°C to +65°C
oStorage temperature range: –40°C to +100°C
oRelative humidity to 95%, noncondensing
INSTALLATION
Before installing the equipment, inspect the OC-3 SFP. If damage
has occurred during shipping, file a claim with the carrier, and
then contact ADTRAN Customer Support. For more information,
refer to the warranty.
ToinstalltheOC‐3SFPintoanappropriatemodule,completethe
followingsteps:
NOTE
Do not remove the protective end cap from the SFP until the fiber
optic cable is ready to be connected.
1. Insert the OC-3 SFP into the SFP cage on the module. Ensur-
ing that the latch handle on the SFP is facing upward, slide
the SFP all the way into the SFP cage until there is an audible
“click”.
NOTE
The latch on the SFP is for removal only. When removing the SFP,
rotate the latch away from the SFP, the SFP should easily slide out
of the cage.
2. Continue the installation and turn-up of the host module
using the instructions in the Job Aid provided with the
module or other system-level documentation available
online at www.adtran.com.
NOTICE
It is recommended that the protective end cap remain on
whenever the transceiver optical fiber connector is not inserted.
PROVISIONING
The OC-3 SFP is not directly provisionable. To provision the OC-3
SFP, access the menu system of the host module. Refer to the
“Provisioning” section of the Job Aid or I&M provided with the
host module for provisioning details.
SAFETY AND REGULATORY COMPLIANCE
CAUTION
C
Electrostatic Discharge (ESD) can damage electronic modules.
When handling modules, wear an antistatic discharge wrist
strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or
storing. When working on modules, always place them on an
approved antistatic mat that is electrically grounded.
Per GR-1089-CORE the ADTRAN system that this product is
being deployed in is designed and intended for installation as
part of a Common Bonding Network (CBN). The ADTRAN
system that this product is being deployed in is not designed
nor intended for installation as part of an Isolated Bonding
Network (IBN).
Small Form-Factor Pluggable
OC-3 Intermediate Reach
CLEI: SOOTAE0J_ _
Product P/N: 1184543PG2
Issue Date: July 2012
Document P/N: 61184543PG2-22A
Per GR-1089-CORE Section 9, this product does not have an
internal DC connection between battery return and frame
ground. This product can be installed in a DC-I (isolated) or
DC-C (common) installation. For installations where other
cards or the host system have internal connections between
battery return and frame ground, the system would be
intended for deployment only in a DC-C installation.
The ADTRAN system chassis frame ground terminal must be
connected to an earth ground to ensure that the metal
enclosure of this product is properly grounded via the
backplane connector.
NOTE
The OC-3 port(s) are optical and therefore are not classified as any
type of port as defined in Appendix B of GR-1089-CORE Issue 4.
This product is NRTL Listed to the applicable UL standards. This
product meets or exceeds all the applicable requirements of
NEBS, Telcordia GR-63-CORE, and GR-1089-CORE. This product
is intended for deployment in Central Office type facilities, EEEs,
EECs, and locations where the NEC applies (for example,
Customer Premises). Install this equipment in an ADTRAN
product located in a restricted access location.
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN
could void the user's authority to operate this equipment.
This product is designed to meet the following environmental
classes:
ETSI EN 300 019-1-1 Classification of environmental conditions;
Storage, Class 1.2
ETSI EN 300 019-1-2 Classification of environmental conditions,
Transportation, Class 2.3
ETSI EN 300 019-1-3 Classification of environmental conditions,
Stationary use at weather-protected locations, Class 3.3
The OC3 IR SFP 1184543PG2 is designed to be deployed in GR-
3108-CORE environmental class 2 as defined in GR-3108-CORE.
The equipment is designed to function without degradation
during exposure to all test severities per Class 3.3.
CAUTION!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY
HANDLING PRECAUTIONS REQUIRED
For more information, refer to the Installation and Maintenance Guide for the host module,
available online at www.adtran.com.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2012 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61184543PG2-22A*

This manual suits for next models

1

Other ADTRAN Transceiver manuals

ADTRAN QSFP28 CWDM4 User manual

ADTRAN

ADTRAN QSFP28 CWDM4 User manual

ADTRAN DDM+ H2TU-C User manual

ADTRAN

ADTRAN DDM+ H2TU-C User manual

ADTRAN 220 HTU-C Instruction Manual

ADTRAN

ADTRAN 220 HTU-C Instruction Manual

ADTRAN SFP+ 10 Gig XGS-PON N2 OLT User manual

ADTRAN

ADTRAN SFP+ 10 Gig XGS-PON N2 OLT User manual

ADTRAN 3192 HDSL4 Instruction Manual

ADTRAN

ADTRAN 3192 HDSL4 Instruction Manual

ADTRAN 1442140G2 User manual

ADTRAN

ADTRAN 1442140G2 User manual

ADTRAN 1442530G1 User manual

ADTRAN

ADTRAN 1442530G1 User manual

ADTRAN 3060 Instruction Manual

ADTRAN

ADTRAN 3060 Instruction Manual

ADTRAN jobAid PR30 User manual

ADTRAN

ADTRAN jobAid PR30 User manual

ADTRAN T200 H2TU-R User manual

ADTRAN

ADTRAN T200 H2TU-R User manual

ADTRAN HDSL4 T200 H4TU-R Instruction Manual

ADTRAN

ADTRAN HDSL4 T200 H4TU-R Instruction Manual

ADTRAN T200 FNID Instruction Manual

ADTRAN

ADTRAN T200 FNID Instruction Manual

ADTRAN T200 H2TU-R Instruction Manual

ADTRAN

ADTRAN T200 H2TU-R Instruction Manual

ADTRAN HTU-C M Instruction Manual

ADTRAN

ADTRAN HTU-C M Instruction Manual

ADTRAN 3192 HTU-C Instruction Manual

ADTRAN

ADTRAN 3192 HTU-C Instruction Manual

ADTRAN QSFP+ User manual

ADTRAN

ADTRAN QSFP+ User manual

ADTRAN T200 H4TU-R Instruction Manual

ADTRAN

ADTRAN T200 H4TU-R Instruction Manual

ADTRAN jobAid+ PR30 10G PON User manual

ADTRAN

ADTRAN jobAid+ PR30 10G PON User manual

ADTRAN 11.3G XFP User manual

ADTRAN

ADTRAN 11.3G XFP User manual

ADTRAN 3192 H4TU-C Instruction Manual

ADTRAN

ADTRAN 3192 H4TU-C Instruction Manual

ADTRAN 3192 H2TU-C Instruction Manual

ADTRAN

ADTRAN 3192 H2TU-C Instruction Manual

ADTRAN E220/220 Maintenance and service guide

ADTRAN

ADTRAN E220/220 Maintenance and service guide

ADTRAN T200 FNID Instruction Manual

ADTRAN

ADTRAN T200 FNID Instruction Manual

ADTRAN T200 H4TU-R User manual

ADTRAN

ADTRAN T200 H4TU-R User manual

Popular Transceiver manuals by other brands

Yaesu FTM-3100R operating manual

Yaesu

Yaesu FTM-3100R operating manual

ipDatatel BAT-CDMA-WIFI installation manual

ipDatatel

ipDatatel BAT-CDMA-WIFI installation manual

Bellman & Symfon BE2350 manual

Bellman & Symfon

Bellman & Symfon BE2350 manual

uAvionix SkyEcho 2 Installation and Pilot's Guide

uAvionix

uAvionix SkyEcho 2 Installation and Pilot's Guide

Kenwood TR-7950 instruction manual

Kenwood

Kenwood TR-7950 instruction manual

Vertex Standard GX1600 Alignment Guide

Vertex Standard

Vertex Standard GX1600 Alignment Guide

Kenwood TM-2570 instruction manual

Kenwood

Kenwood TM-2570 instruction manual

Alinco DR-610T instruction manual

Alinco

Alinco DR-610T instruction manual

Intek MT-5050 owner's manual

Intek

Intek MT-5050 owner's manual

National Instruments PXIe-5842 Getting started

National Instruments

National Instruments PXIe-5842 Getting started

Kenwood TS-820S instruction manual

Kenwood

Kenwood TS-820S instruction manual

DZ PSKUBE PSQ-100 Assembly manual

DZ

DZ PSKUBE PSQ-100 Assembly manual

Vertex Standard HX280S manual

Vertex Standard

Vertex Standard HX280S manual

Terasic NET-FMC user manual

Terasic

Terasic NET-FMC user manual

National Semiconductor DS36C278 s and Specifications and installation

National Semiconductor

National Semiconductor DS36C278 s and Specifications and installation

demi 222-28 manual

demi

demi 222-28 manual

Apache Labs ANAN-10+ user guide

Apache Labs

Apache Labs ANAN-10+ user guide

Alinco DR-138 instruction manual

Alinco

Alinco DR-138 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.