manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Transceiver
  8. •
  9. ADTRAN 1442530G1 User manual

ADTRAN 1442530G1 User manual

Other ADTRAN Transceiver manuals

ADTRAN jobAid PR30 User manual

ADTRAN

ADTRAN jobAid PR30 User manual

ADTRAN SFP+ 10 Gig XGS-PON N2 OLT User manual

ADTRAN

ADTRAN SFP+ 10 Gig XGS-PON N2 OLT User manual

ADTRAN OC-3 User manual

ADTRAN

ADTRAN OC-3 User manual

ADTRAN T200 FNID Instruction Manual

ADTRAN

ADTRAN T200 FNID Instruction Manual

ADTRAN 3192 H4TU-C Instruction Manual

ADTRAN

ADTRAN 3192 H4TU-C Instruction Manual

ADTRAN 3192 User manual

ADTRAN

ADTRAN 3192 User manual

ADTRAN T200 FNID Instruction Manual

ADTRAN

ADTRAN T200 FNID Instruction Manual

ADTRAN T200 H4TU-R User manual

ADTRAN

ADTRAN T200 H4TU-R User manual

ADTRAN SFP OC3-48 1G CWDM 80KM User manual

ADTRAN

ADTRAN SFP OC3-48 1G CWDM 80KM User manual

ADTRAN 1442482F7 User manual

ADTRAN

ADTRAN 1442482F7 User manual

ADTRAN Combo PON D2 SFP+ User manual

ADTRAN

ADTRAN Combo PON D2 SFP+ User manual

ADTRAN SFP+ 10 Gig XGS-PON N2 OLT User manual

ADTRAN

ADTRAN SFP+ 10 Gig XGS-PON N2 OLT User manual

ADTRAN HDSL4 T200 H4TU-R Instruction Manual

ADTRAN

ADTRAN HDSL4 T200 H4TU-R Instruction Manual

ADTRAN 220 HDSL4 Instruction Manual

ADTRAN

ADTRAN 220 HDSL4 Instruction Manual

ADTRAN 3060 Instruction Manual

ADTRAN

ADTRAN 3060 Instruction Manual

ADTRAN 3192 H2TU-C Instruction Manual

ADTRAN

ADTRAN 3192 H2TU-C Instruction Manual

ADTRAN HDSL4 T200 H4TU-R User manual

ADTRAN

ADTRAN HDSL4 T200 H4TU-R User manual

ADTRAN HTU-C M Instruction Manual

ADTRAN

ADTRAN HTU-C M Instruction Manual

ADTRAN 3192 H4TU-C Instruction Manual

ADTRAN

ADTRAN 3192 H4TU-C Instruction Manual

ADTRAN QSFP28 CWDM4 User manual

ADTRAN

ADTRAN QSFP28 CWDM4 User manual

ADTRAN T200 H2TU-R User manual

ADTRAN

ADTRAN T200 H2TU-R User manual

ADTRAN E220/220 Maintenance and service guide

ADTRAN

ADTRAN E220/220 Maintenance and service guide

ADTRAN DDM+ H2TU-C User manual

ADTRAN

ADTRAN DDM+ H2TU-C User manual

ADTRAN T200 H4TU-R Instruction Manual

ADTRAN

ADTRAN T200 H4TU-R Instruction Manual

Popular Transceiver manuals by other brands

Kenwood ProTalk TK-3201 instruction manual

Kenwood

Kenwood ProTalk TK-3201 instruction manual

City Theatrical SHoW DMX SHoW Baby user manual

City Theatrical

City Theatrical SHoW DMX SHoW Baby user manual

Standart Horizont HX407 owner's manual

Standart Horizont

Standart Horizont HX407 owner's manual

B&G V90S quick start guide

B&G

B&G V90S quick start guide

VictelGlobal ALK300 series Operation manual

VictelGlobal

VictelGlobal ALK300 series Operation manual

Cactus Wireless Flash Transceiver V6 user manual

Cactus

Cactus Wireless Flash Transceiver V6 user manual

Yaesu FT-11R user guide

Yaesu

Yaesu FT-11R user guide

Skanti TRP 5000 instruction manual

Skanti

Skanti TRP 5000 instruction manual

ELECRAFT KX3 Installation and operation guide

ELECRAFT

ELECRAFT KX3 Installation and operation guide

American Lighting DMX512 quick start guide

American Lighting

American Lighting DMX512 quick start guide

Furuno FM-77 Operator's handbook

Furuno

Furuno FM-77 Operator's handbook

Yaesu FT-7B manual

Yaesu

Yaesu FT-7B manual

Mizuho MX-2 Operating & assembly instruction

Mizuho

Mizuho MX-2 Operating & assembly instruction

Kenwood TK-3180 Manuale di istruzioni

Kenwood

Kenwood TK-3180 Manuale di istruzioni

Blitz MJ-398U instruction manual

Blitz

Blitz MJ-398U instruction manual

Utilicom LongRanger 2050 Operator's manual

Utilicom

Utilicom LongRanger 2050 Operator's manual

Standart HX290UKA Service manual

Standart

Standart HX290UKA Service manual

Altronix Pace1PTM installation guide

Altronix

Altronix Pace1PTM installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

jobAid
DESCRIPTION
TheSmallForm‐FactorPluggable(SFP)isasingle‐modefiberSFP
thatplugsintoanADTRANopticalinterfacedesignedtoaccept
SFPs.TheSFPprovidesasingleopticalinterfacetoaphysical
interface,andisintendedforusewithaGigabitPassiveOptical
Network(GPON)OpticalLineTermination(OLT)module.
Installedintoanappropriatemodule,theSFPprovidesaGPON
interfacetothesupportingsystem.
ThisSFPisdesignedforuseinWavelengthDivisionMultiplexing
(WDM)applications.
ThisSFPhasaDigitalDiagnosticMonitoring(DDM)function
withinternalcalibration.
ThefollowingfeaturesaresupportedontheSFP:
♦Dataratedownstream:2.488Gbps
♦Daterateupstream:1.244Gbps
♦TransmitWavelength:1490nm
♦ReceiveWavelength:1310nm
♦Opticaldistance:30kmmaximum
♦HotPluggable
Operational Specifications
♦OpticalSpecifications:
◊Opticaltransmitlevel:+1.5dBmto+5dBm
◊Opticalreceivelevel:–30dBmminimum
◊Opticalconnectors:SC
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–40°Cto+85°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto95%,noncondensing
◊OperatingAltitudeRange:–197feet(–60meters)to13000
feet(3962meters)
NOTE
Theoperatingambienttemperatureisderatedby1°C/1000feet
(3.3°C/km).
CAUTION
!
Duetocompliancecertificationrequirements,onlySFPs
approvedbyADTRANaretobeusedwiththehostmodule.
ADTRANcannotcertifysystemintegritywithotherSFPs.
INSTALLATION
ToinstalltheSFPintoanappropriatemodule,completethe
followingsteps:
InspecttheSFP.Ifdamaged,fileaclaimwiththecarrierandthen
contactADTRANCustomerSupport.
CAUTION
!
DonotremovetheprotectiveendcapfromtheSFPuntilthefiber
opticcableisreadytobeconnected.
1. InserttheSFPintotheSFPcageonthemodule.Ensurethe
latchontheSFPisfacingupwardforcorrectinstallation.
2. SlidetheSFPallthewayintotheSFPcageuntilthereisan
audible“click”.
NOTE
♦ ThelatchontheSFPisusedtoremovetheSFPfromthecage
onthecircuitcard.
♦ TheSFPmeetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR‐63‐CORE,andGR‐1089‐CORE.
COMPLIANCE
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccomponents.Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
workingonmodules,alwaysplacethemonanapproved
antistaticmatthatiselectricallygrounded.
NOTE
♦ TheSFPisaClass1LaserProductandcomplieswiththeLaser
SafetyrequirementsofFDA21CFR1040.10and1040.11,and
EN60825‐1and‐2.TheSFPisNRTLListedandCBCertifiedto
allapplicableAmericanandEuropeansafetystandards.
♦ TheSFPhasbeenevaluatedtointernationalsafetystandards
EN60950‐1,AS/NZS60950.1,andIEC60950‐1.TheSFPmeets
therequirementsforCEmarkingundertheEMCDirective
andLowVoltageDirective.Standardsusedtodemonstrate
ComplianceareEN300386,EN50222,EN55024asapplicable
andEN60950.
CLEI: BVL3AHFD_ _
Product P/N: 1442530G1
Issue Date: April 2010
Document P/N: 61442530G1-22A
Small Form-Factor Pluggable
GPON OLT
Transceiver SFP
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
CAUTION
!
TheSFPisintendedfordeploymentinCentralofficetype
facilities,EEEs,EECs,andlocationswhereNECapplies(for
example,CustomerPremises).TheSFPmustbeinstalledby
trainedservicepersonnelinADTRANproductsthatarelocated
inRestrictedAccessLocations.
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CAUTION
!
♦ PerGR‐1089‐COREtheADTRANsystemthattheSFPisbeing
deployedinisdesignedandintendedforinstallationaspartof
aCommonBondingNetwork(CBN).TheADTRANsystem
thattheSFPisbeingdeployedinisnotdesignednorintended
forinstallationaspartofanIsolatedBondingNetwork(IBN).
♦ PerGR‐1089‐CORESection9,theSFPdoesnothaveaninternal
DCconnectionbetweenbatteryreturnandframeground.The
SFPcanbeinstalledinaDC‐I(isolated)orDC‐C(common)
configuration.Forinstallationswhereothercardsorthehost
systemhaveinternalconnectionsbetweenbatteryreturnand
frameground,thesystemwouldbeintendedfordeployment
onlyinaDC‐Cconfiguration.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheSFPisproperlygroundedviathebackplane
connector.
NOTE
♦ TheGPONisopticalandthereforeisnotclassifiedasanytype
ofportasdefinedinAppendixBofGR‐1089‐COREIssue5.
♦ TheSFPisdesignedfordeploymentinGR‐3108‐CORE
environmentalclass1and2,asdefinedinGR‐3108,Issue2.
TheSFPisdesignedtomeetthefollowingenvironmentalclasses:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
Warranty:ADTRAN will replace or repair this product within the warranty period if it does not meet its
published specifications or fails while in service. Warranty information can be found online at
www.adtran.com/warranty.
©2010 ADTRAN, Inc. All Rights Reserved.
*61442530G1-22A*
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
NOTE
♦ ThisSFPiscompliantwithSFF‐8472“DigitalDiagnostics
MonitoringInterfaceforOpticalTransceiver,”Revision9.3
♦ ThisSFPiscompliantwithSmallForm‐FactorPluggable(SFP)
Multi‐SourceAgreement(MSA).
♦ TheSFPcomplieswithG984.2ClassB+opticsrequirements
withthefollowingexceptions:
1.EnhancedReceiverSensitivityof–30dBm
2.MinimumReceiverOverloadof–10dBm