AC Current Probe
Models SR701 and SR704
User Manual
DESCRIPTION
The SR701/SR704 AC Current Probes (Catalog #2116.29 and #2116.30) are designed for
use in industrial environments. The ergonomic design allows them to easily attach to cables or
small bus bars. The “circular” jaws guarantee a very good accuracy and low phase shift. The
probes have a measurement range up to 1000 Arms and are compatible with any AC ammeter,

To achieve the stated accuracy, use the SR701/SR704 with an ammeter having an accuracy of
0.75 % or better.
WARNING
These safety warnings are provided to ensure the safety of personnel and proper operation of the instrument.
Read the instruction manual completely and follow all the safety information before attempting to use or
service this instrument.
• Use caution on any circuit: potentially high voltages and currents may be present and may pose a shock
hazard.
• Do not use the probe if damaged. Always connect the current probe to the measuring device before it is
connected around the conductor
• Do not use on non-insulated conductor with a potential to ground greater than 600 V CAT III pollution 2.
Use extreme caution when clamping around bare conductors or bus bars.
• Before each use, inspect the probe; look for cracks in housing or output cable insulation.
• Do not use clamp in wet environment or in locations that hazardous gases exist.
• Do not use the probe anywhere beyond the tactile barrier.
INTERNATIONAL ELECTRICAL SYMBOLS



before using the instrument.


DEFINITION OF MEASUREMENT CATEGORIES
CAT IV: For measurements performed at the primary electrical supply (< 1000 V), such as
on primary overcurrent protection devices, ripple control units, or meters.
CAT III: For measurements performed in the building installation at the distribution level, such
 
CAT II: For measurements performed on circuits directly connected to the electrical
distribution system, such as measurements on household appliances or portable
tools.
RECEIVING YOUR SHIPMENT
Upon receiving your shipment, make sure that the contents are consistent with the packing


description of any damage.
CURRENT PROBE - SR701/SR704 DRAWING
ELECTRICAL SPECIFICATIONS
Current Range: 1 mA to 1200 A
Transformation Ratio: 1000:1
Output Signal: 1 mA AC/A
(1 A at 1000 A)
Accuracy and Phase Shift*:
Accuracy:
(1 to 100) mA: ±3 % Reading ±5 mA
(0.1 to 1) A: ±2 % Reading ±3 mA
(1 to 10) A: ±1 % Reading
(10 to 100) A: ±0.5 % Reading
(100 to 1200) A: ±0.3 % Reading
Phase Shift:






75) % RH, (48 to 65) Hz, external magnetic

current carrying conductor, test sample cen-

Overload: 󰀨
Accuracy: 
Frequency Range: 30 Hz to 5 kHz; current
derating above 1 kHz using the formula:
1000 A × 1
F (kHz)
Load Impedence: 5 
Working Voltage: 600 V CAT III
Common Mode Voltage: 600 V CAT III
Open Secondary Voltage:
<25 V by limiting circuit
Inuence of Adjacent Conductor:
< 1 mA/AAC
Weight:
1.21 lbs (550 g)
Output:
SR701: (2) standard safety banana jacks (4
mm)
SR704:5 ft (1.5 m) lead with safety 4 mm
banana plug
SAFETY SPECIFICATIONS
Electrical:
Double insulation or reinforced insulation be-
tween the primary or secondary and the outer
case of the handle conforms to

Common Mode Voltage:
600 V CAT III, Pollution Degree 2
Electromagnetic Compatibility:
-

ORDERING INFORMATION
AC Current Probe SR701 ........Cat #2116.29
AC Current Probe SR704 ........Cat #2116.30
Accessories:

(1000 V CAT IV) .........................Cat #2152.24

 ............. Cat #2118.46
Banana plug adapter
(to non-recessed plug)................Cat #1017.45
Inuence of Conductor in Jaw Opening:
0.1 % of Reading
Inuence of Frequency:
From (30 to 48) Hz: < 0.5 % of R
From (65 to 1000) Hz: < 1 % of R
From (1 to 5) kHz: < 2 % of R
MECHANICAL SPECIFICATIONS
Operating Temperature:

Storage Temperature:

Inuence of Temperature:

Inuence of Humidity:
From (10 to 90) % RH: 0.1 %
Jaw Opening:
2.25 in (57mm) max
Maximum Conductor Size:
2.05 in (52 mm)
Envelope Protection: 
Drop Test: 
Mechanical Shock: 
Vibration:

(15 to 25) Hz, 1 mm
(25 to 55) Hz, 0.25 mm
Material:

Dimensions:
(4.37 x 8.50 x 1.77) in (111 x 216 x 45) mm
OPERATION

page 1.
Making Measurements with the AC Current Probe Models SR701/SR740
• Connect the black lead of the current probe to “common” and the red lead to the AC

current range (2 AAC range). Clamp the probe around the conductor to be tested with the
arrow pointed toward the load. If the reading is less than 200 mA, select the lower range


0.659 A x 1000 = 659 AAC).
• For best accuracy, avoid if possible, the proximity of other conductors which may create
noise.
Tips For Making Precise Measurements
• When using a current probe with a meter, please select the range that provides the best
resolution. Failure to do this may result in measurement errors.
• 
Contaminants cause air gaps between the jaws, increasing the phase shift between
primary and secondary. It is very critical for power measurement.
MAINTENANCE
Warning
• For maintenance use only original replacement parts.
• To avoid electrical shock, do not attempt to perform any service on the device unless you

• To avoid electrical shock and/or damage to the instrument, do not allow water or other
foreign agents to come into contact with the probe.
Cleaning
To ensure optimum performance, it is important to keep the probe jaw mating surfaces clean at


REPAIR AND CALIBRATION
You must contact our Service Center for a Customer Service Authorization number (CSA#).
This will ensure that, when your instrument arrives, it will be tracked and processed promptly.
Please write the CSA# on the outside of the shipping container.
Ship To: Chauvin Arnoux®®Instruments
 
  
   repair@aemc.com
(Or contact your authorized distributor)
NOTE: You must obtain a CSA# before returning any instrument.
TECHNICAL AND SALES ASSISTANCE

operation or application of your instrument, please call, e-mail or fax our technical support team:
Contact: Chauvin Arnoux®®Instruments
  
  [email protected]
LIMITED WARRANTY
The current probe is warrantied to the owner for a period of two years from the date of
®
Instruments, not by the distributor from whom it was purchased. This warranty is void if the unit
®
Instruments.
Full warranty coverage and product registration is available on our website at:
www.aemc.com/warranty.html.
Please print the online Warranty Coverage Information for your records.


This manual suits for next models

3

Other AEMC instruments Measuring Instrument manuals

AEMC instruments MN09 User manual

AEMC instruments

AEMC instruments MN09 User manual

AEMC instruments Measure Up PowerPad III User manual

AEMC instruments

AEMC instruments Measure Up PowerPad III User manual

AEMC instruments 6501 User manual

AEMC instruments

AEMC instruments 6501 User manual

AEMC instruments 300-24-2-10 User manual

AEMC instruments

AEMC instruments 300-24-2-10 User manual

AEMC instruments SL261 User manual

AEMC instruments

AEMC instruments SL261 User manual

AEMC instruments Simple Logger AmpFlex AL24-2500 User manual

AEMC instruments

AEMC instruments Simple Logger AmpFlex AL24-2500 User manual

AEMC instruments MN103 User manual

AEMC instruments

AEMC instruments MN103 User manual

AEMC instruments MN213 User manual

AEMC instruments

AEMC instruments MN213 User manual

AEMC instruments MA194-24-BK User manual

AEMC instruments

AEMC instruments MA194-24-BK User manual

AEMC instruments CA846 User manual

AEMC instruments

AEMC instruments CA846 User manual

AEMC instruments SIMPLE LOGGER L100 User manual

AEMC instruments

AEMC instruments SIMPLE LOGGER L100 User manual

AEMC instruments SR601 User manual

AEMC instruments

AEMC instruments SR601 User manual

AEMC instruments PowerPad IV 8345 User manual

AEMC instruments

AEMC instruments PowerPad IV 8345 User manual

AEMC instruments MN312 User manual

AEMC instruments

AEMC instruments MN312 User manual

AEMC instruments CA7027 User manual

AEMC instruments

AEMC instruments CA7027 User manual

AEMC instruments AmpFlex User manual

AEMC instruments

AEMC instruments AmpFlex User manual

AEMC instruments SR759 User manual

AEMC instruments

AEMC instruments SR759 User manual

AEMC instruments OX5042 User manual

AEMC instruments

AEMC instruments OX5042 User manual

AEMC instruments A196-24-BK User manual

AEMC instruments

AEMC instruments A196-24-BK User manual

AEMC instruments 502 User manual

AEMC instruments

AEMC instruments 502 User manual

AEMC instruments 5070 User manual

AEMC instruments

AEMC instruments 5070 User manual

AEMC instruments FlexProbe 24-3001 User manual

AEMC instruments

AEMC instruments FlexProbe 24-3001 User manual

AEMC instruments 6528 User manual

AEMC instruments

AEMC instruments 6528 User manual

AEMC instruments 6527 User manual

AEMC instruments

AEMC instruments 6527 User manual

Popular Measuring Instrument manuals by other brands

Hioki 8841 instruction manual

Hioki

Hioki 8841 instruction manual

Common CGR-01 Series manual

Common

Common CGR-01 Series manual

YOKOGAWA 96065 user manual

YOKOGAWA

YOKOGAWA 96065 user manual

PCB Piezotronics IMI SENSORS RTD602D11 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS RTD602D11 Installation and operating manual

mercor MCRP 054 User instruction manual

mercor

mercor MCRP 054 User instruction manual

Mitutoyo LGF-110L-B manual

Mitutoyo

Mitutoyo LGF-110L-B manual

Hioki 3447-01 instruction manual

Hioki

Hioki 3447-01 instruction manual

Hioki 3661-20 instruction manual

Hioki

Hioki 3661-20 instruction manual

HEIDENHAIN LS 608 C Replacing Instructions

HEIDENHAIN

HEIDENHAIN LS 608 C Replacing Instructions

Kessel SonicControl Installation, operation and maintenance instructions

Kessel

Kessel SonicControl Installation, operation and maintenance instructions

Meriam meriGauge Plus user manual

Meriam

Meriam meriGauge Plus user manual

Bacharach Fyrite INSIGHT PLUS instruction manual

Bacharach

Bacharach Fyrite INSIGHT PLUS instruction manual

CS Instruments FA 410 instruction manual

CS Instruments

CS Instruments FA 410 instruction manual

PCB Piezotronics 353B77 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 353B77 Installation and operating manual

Electro Industries/GaugeTech Shark 100T quick start guide

Electro Industries/GaugeTech

Electro Industries/GaugeTech Shark 100T quick start guide

Wentworth Technology Pegasus S200 Installation and operation manual

Wentworth Technology

Wentworth Technology Pegasus S200 Installation and operation manual

HORNER XL7 user manual

HORNER

HORNER XL7 user manual

Smart Caregiver TL-2015R2 Installation and use instructions

Smart Caregiver

Smart Caregiver TL-2015R2 Installation and use instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.