DESCRIPTION
The SR701/SR704 AC Current Probes (Catalog #2116.29 and #2116.30) are designed for
use in industrial environments. The ergonomic design allows them to easily attach to cables or
small bus bars. The “circular” jaws guarantee a very good accuracy and low phase shift. The
probes have a measurement range up to 1000 Arms and are compatible with any AC ammeter,

To achieve the stated accuracy, use the SR701/SR704 with an ammeter having an accuracy of
0.75 % or better.
WARNING
These safety warnings are provided to ensure the safety of personnel and proper operation of the instrument.
Read the instruction manual completely and follow all the safety information before attempting to use or
service this instrument.
• Use caution on any circuit: potentially high voltages and currents may be present and may pose a shock
hazard.
• Do not use the probe if damaged. Always connect the current probe to the measuring device before it is
connected around the conductor
• Do not use on non-insulated conductor with a potential to ground greater than 600 V CAT III pollution 2.
Use extreme caution when clamping around bare conductors or bus bars.
• Before each use, inspect the probe; look for cracks in housing or output cable insulation.
• Do not use clamp in wet environment or in locations that hazardous gases exist.
• Do not use the probe anywhere beyond the tactile barrier.
INTERNATIONAL ELECTRICAL SYMBOLS



before using the instrument.


DEFINITION OF MEASUREMENT CATEGORIES
CAT IV: For measurements performed at the primary electrical supply (< 1000 V), such as
on primary overcurrent protection devices, ripple control units, or meters.
CAT III: For measurements performed in the building installation at the distribution level, such
 
CAT II: For measurements performed on circuits directly connected to the electrical
distribution system, such as measurements on household appliances or portable
tools.
RECEIVING YOUR SHIPMENT
Upon receiving your shipment, make sure that the contents are consistent with the packing


description of any damage.
CURRENT PROBE - SR701/SR704 DRAWING
ELECTRICAL SPECIFICATIONS
Current Range: 1 mA to 1200 A
Transformation Ratio: 1000:1
Output Signal: 1 mA AC/A
(1 A at 1000 A)
Accuracy and Phase Shift*:
Accuracy:
(1 to 100) mA: ±3 % Reading ±5 mA
(0.1 to 1) A: ±2 % Reading ±3 mA
(1 to 10) A: ±1 % Reading
(10 to 100) A: ±0.5 % Reading
(100 to 1200) A: ±0.3 % Reading
Phase Shift:






75) % RH, (48 to 65) Hz, external magnetic

current carrying conductor, test sample cen-

Overload: 󰀨
Accuracy: 
Frequency Range: 30 Hz to 5 kHz; current
derating above 1 kHz using the formula:
1000 A × 1
F (kHz)
Load Impedence: 5 
Working Voltage: 600 V CAT III
Common Mode Voltage: 600 V CAT III
Open Secondary Voltage:
<25 V by limiting circuit
Inuence of Adjacent Conductor:
< 1 mA/AAC
Weight:
1.21 lbs (550 g)
Output:
SR701: (2) standard safety banana jacks (4
mm)
SR704:5 ft (1.5 m) lead with safety 4 mm
banana plug
SAFETY SPECIFICATIONS
Electrical:
Double insulation or reinforced insulation be-
tween the primary or secondary and the outer
case of the handle conforms to

Common Mode Voltage:
600 V CAT III, Pollution Degree 2
Electromagnetic Compatibility:
-

ORDERING INFORMATION
AC Current Probe SR701 ........Cat #2116.29
AC Current Probe SR704 ........Cat #2116.30
Accessories:

(1000 V CAT IV) .........................Cat #2152.24

 ............. Cat #2118.46
Banana plug adapter
(to non-recessed plug)................Cat #1017.45
Inuence of Conductor in Jaw Opening:
0.1 % of Reading
Inuence of Frequency:
From (30 to 48) Hz: < 0.5 % of R
From (65 to 1000) Hz: < 1 % of R
From (1 to 5) kHz: < 2 % of R
MECHANICAL SPECIFICATIONS
Operating Temperature:

Storage Temperature:

Inuence of Temperature:

Inuence of Humidity:
From (10 to 90) % RH: 0.1 %
Jaw Opening:
2.25 in (57mm) max
Maximum Conductor Size:
2.05 in (52 mm)
Envelope Protection: 
Drop Test: 
Mechanical Shock: 
Vibration:

(15 to 25) Hz, 1 mm
(25 to 55) Hz, 0.25 mm
Material:

Dimensions:
(4.37 x 8.50 x 1.77) in (111 x 216 x 45) mm
OPERATION

page 1.
Making Measurements with the AC Current Probe Models SR701/SR740
• Connect the black lead of the current probe to “common” and the red lead to the AC

current range (2 AAC range). Clamp the probe around the conductor to be tested with the
arrow pointed toward the load. If the reading is less than 200 mA, select the lower range


0.659 A x 1000 = 659 AAC).
• For best accuracy, avoid if possible, the proximity of other conductors which may create
noise.
Tips For Making Precise Measurements
• When using a current probe with a meter, please select the range that provides the best
resolution. Failure to do this may result in measurement errors.
• 
Contaminants cause air gaps between the jaws, increasing the phase shift between
primary and secondary. It is very critical for power measurement.
MAINTENANCE
Warning
• For maintenance use only original replacement parts.
• To avoid electrical shock, do not attempt to perform any service on the device unless you

• To avoid electrical shock and/or damage to the instrument, do not allow water or other
foreign agents to come into contact with the probe.
Cleaning
To ensure optimum performance, it is important to keep the probe jaw mating surfaces clean at


REPAIR AND CALIBRATION
You must contact our Service Center for a Customer Service Authorization number (CSA#).
This will ensure that, when your instrument arrives, it will be tracked and processed promptly.
Please write the CSA# on the outside of the shipping container.
Ship To: Chauvin Arnoux®®Instruments
 
  
   repair@aemc.com
(Or contact your authorized distributor)
NOTE: You must obtain a CSA# before returning any instrument.
TECHNICAL AND SALES ASSISTANCE

operation or application of your instrument, please call, e-mail or fax our technical support team:
Contact: Chauvin Arnoux®®Instruments
  
  [email protected]
LIMITED WARRANTY
The current probe is warrantied to the owner for a period of two years from the date of
®
Instruments, not by the distributor from whom it was purchased. This warranty is void if the unit
®
Instruments.
Full warranty coverage and product registration is available on our website at:
www.aemc.com/warranty.html.
Please print the online Warranty Coverage Information for your records.


This manual suits for next models

3

Other AEMC instruments Measuring Instrument manuals

AEMC instruments PEL 105 User manual

AEMC instruments

AEMC instruments PEL 105 User manual

AEMC instruments CA846 User manual

AEMC instruments

AEMC instruments CA846 User manual

AEMC instruments 1035 User manual

AEMC instruments

AEMC instruments 1035 User manual

AEMC instruments Clamp-On 3705 User manual

AEMC instruments

AEMC instruments Clamp-On 3705 User manual

AEMC instruments 300-24-2-10 User manual

AEMC instruments

AEMC instruments 300-24-2-10 User manual

AEMC instruments 6528 User manual

AEMC instruments

AEMC instruments 6528 User manual

AEMC instruments CM605 User manual

AEMC instruments

AEMC instruments CM605 User manual

AEMC instruments 6240 User manual

AEMC instruments

AEMC instruments 6240 User manual

AEMC instruments 6292 User manual

AEMC instruments

AEMC instruments 6292 User manual

AEMC instruments PowerPad IV 8345 User manual

AEMC instruments

AEMC instruments PowerPad IV 8345 User manual

AEMC instruments AmpFlex 193-24-BK User manual

AEMC instruments

AEMC instruments AmpFlex 193-24-BK User manual

AEMC instruments JM852 User manual

AEMC instruments

AEMC instruments JM852 User manual

AEMC instruments MD305 User manual

AEMC instruments

AEMC instruments MD305 User manual

AEMC instruments Simple Logger AmpFlex AL24-2500 User manual

AEMC instruments

AEMC instruments Simple Logger AmpFlex AL24-2500 User manual

AEMC instruments MN103 User manual

AEMC instruments

AEMC instruments MN103 User manual

AEMC instruments MR525 User manual

AEMC instruments

AEMC instruments MR525 User manual

AEMC instruments MR525 User manual

AEMC instruments

AEMC instruments MR525 User manual

AEMC instruments JM865A User manual

AEMC instruments

AEMC instruments JM865A User manual

AEMC instruments 6505 User manual

AEMC instruments

AEMC instruments 6505 User manual

AEMC instruments SL261 User manual

AEMC instruments

AEMC instruments SL261 User manual

AEMC instruments SR759 User manual

AEMC instruments

AEMC instruments SR759 User manual

AEMC instruments MN134 User manual

AEMC instruments

AEMC instruments MN134 User manual

AEMC instruments MN01 User manual

AEMC instruments

AEMC instruments MN01 User manual

AEMC instruments OX5042 User manual

AEMC instruments

AEMC instruments OX5042 User manual

Popular Measuring Instrument manuals by other brands

Megger MJOLNER 200 user manual

Megger

Megger MJOLNER 200 user manual

PCB Piezotronics 352A21/NC Installation and operating manual

PCB Piezotronics

PCB Piezotronics 352A21/NC Installation and operating manual

Kane 258 Quick reference guide

Kane

Kane 258 Quick reference guide

Intellimeter I-METER 45 Installation and user manual

Intellimeter

Intellimeter I-METER 45 Installation and user manual

Endress+Hauser Proline t-mass 65 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline t-mass 65 Brief operating instructions

Shimpo DT-207L instruction manual

Shimpo

Shimpo DT-207L instruction manual

Jaquet MultiTasker T601 instruction manual

Jaquet

Jaquet MultiTasker T601 instruction manual

PPI UPI-5D user manual

PPI

PPI UPI-5D user manual

CTC Union MMX6000 Series product manual

CTC Union

CTC Union MMX6000 Series product manual

JGR TLS5 user manual

JGR

JGR TLS5 user manual

ElektroPhysik SmarTest quick start guide

ElektroPhysik

ElektroPhysik SmarTest quick start guide

MICRO-EPSILON surfaceCONTROL 3D SC3200-80 operating instructions

MICRO-EPSILON

MICRO-EPSILON surfaceCONTROL 3D SC3200-80 operating instructions

GHM GREISINGER GMH 3531 operating manual

GHM

GHM GREISINGER GMH 3531 operating manual

Fluidwell B Series Quick reference guide

Fluidwell

Fluidwell B Series Quick reference guide

West Mountain Radio PWRcheck operating manual

West Mountain Radio

West Mountain Radio PWRcheck operating manual

KERN&SOHN ABP operating instructions

KERN&SOHN

KERN&SOHN ABP operating instructions

Kobold NMF operating instructions

Kobold

Kobold NMF operating instructions

Fluke Nuclear Associates 07-453 instruction manual

Fluke

Fluke Nuclear Associates 07-453 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.