6MJÖLNER 200/600 ZP-BD02E BD0161OE
1 SAFETY
1Safety
Symbols on the instrument
Caution, refer to accompanying docu-
ments.
Caution, risk of electric shock.
Protective conductor terminal.
WEEE, Waste Electrical and Electronic
Equipment. Please utilize your local
WEEE collection facilities in the dispo-
sition of this product and otherwise
observe all applicable requirements.
The unit can also be returned to
Megger at any timeat at no charge for
the disposal.
Information duty regarding substances
on REACH article 33, SVHC-list
This product contains a coin cell battery which con-
tains 1,2- dimethoxyethane (CAS 110-71-4) above
0.1% by weight.
Safety instructions
Important
Read and comply with the safety instruc-
tions.
Always comply with local safety regula-
tions.
Warning
1.
Before measuring resistance in circuit breakers
or disconnecting switches (isolators), always
check to see that the object being tested is
closed and grounded at least on one side.
2.
Do not connect the instrument to inductive
loads. This can cause high voltages when re-
moving the current clamps.
3.
After completing your measurements, you can
follow the normal procedures that are used to
demagnetize current transformer cores after DC
has passed through a current transformer.
4.
Never open a circuit breaker while MJÖLNER is
connected to it.
5.
Connection points for current cables can be-
come hot during current generation.
6.
Current continues to flow for a while after the
MJÖLNER is turned off. How long it continues
depends on the ratio of the components in the
L/R circuit.
7.
High voltage/current on input/output terminals.
8.
Do not attempt to service the instrument your-
self. Opening or removing covers may expose
you to dangerous voltage. If you attempt to
service the instrument yourself the warranty is
no longer valid.
9.
Do not use any accessories that are not intend-
ed for use together with the instrument.
10.
Disconnect the instrument from the mains be-
fore cleaning. Use a damp cloth for cleaning. Do
not use liquid cleaners or aerosol cleaners.
Important
1.
The instrument is intended for use in an in-
dustrial environment. It generates, uses and
can radiate radio frequency energy and, if not
installed and used in accordance with these
instructions, may cause interference to other
devices in the vicinity. If this equipment does
cause interference with other devices, which can
be determined by turning the equipment off
and on, the user is encouraged to try to correct
the interference by one or more of the following
measures:
▪Reorient or relocate the receiving device.
▪Increase the separation between the equipments.
▪Connect the equipment into an outlet on a circuit
different from that to which the other device(s) is
connected.
▪Consult the manufacturer or field service technician
for help.