AERMEC WLRC20 User manual

www.aermec.com
Translation from original
User manual
■
REMOTE CONTROL
19.07 - 5044576_02
WLRC20

All specifications are subject to change without prior notice. Although every effort has been made to
ensure accuracy, Aermec shall not be held liable for any errors or omissions.
Dear customer,
Thank you for choosing an AERMEC product. It is the fruit of many years of experience and special
design studies and has been made of the highest grade materials and with cutting edge technology.
In addition, all our products bear the EC mark indicating that they meet the requirements of the
European Machine Directive regarding safety. The quality level is being constantly monitored, so
AERMEC products are synonymous with Safety, Quality and Reliability.
The data may undergo modifications considered necessary for the improvement of the
product, at any time and without the obligation for any notice thereof.
Thank you once again.
AERMEC S.p.A
This marking indicates that this product should not be disposed with other household
wastes throughout the EU.
To prevent possible harm to the environment or human health from uncontrolled disposal
of Waste Electrical and Electronic Equipment (WEEE), please return the device using
appropriate collection systems, or contact the retailer where the product was purchased.
Please contact your local authority for further details.
Illegal dumping of the product by the user entails the application of administrative
sanctions provided by law
INFORMATION FOR USER
This device is universal.
By pressing a key for a function that is not available, the unit will not change the operating status.
Never install the device in a damp area and do not expose it to direct sunlight.
Do not bump, throw or disassemble the device frequently.
Never use the device with wet hands.
Carefully read the manual before using and installing the device.

REMOTE CONTROL.................................................................................................................................................................................................................4
FUNCTIONS AVAILABLE THROUGH THE REMOTE CONTROL................................................................................................................................6
SWITCHING THE UNIT ON OR OFF...................................................................................................................................................................................6
SETTING THE OPERATING SETPOINT............................................................................................................................................................................6
SELECTING AN OPERATING MODE..................................................................................................................................................................................7
SETTING THE VENTILATION SPEED .................................................................................................................................................................................8
ACTIVATING / DEACTIVATING THE TURBO FUNCTION............................................................................................................................................8
SETTING THE DELIVERY FIN SWING .............................................................................................................................................................................9
ACTIVATING / DEACTIVATING THE I FEEL FUNCTION...........................................................................................................................................10
AIR PURIFIER BUTTON COLD PLASMA........................................................................................................................................................................10
DISPLAY THE ROOM TEMPERATURE, OPERATION SET OR OUTSIDE TEMPERATURE ...............................................................................11
SETTING A SYSTEM TIME..................................................................................................................................................................................................12
ACTIVATING / DEACTIVATING THE INDOOR UNIT’S DISPLAY............................................................................................................................12
SETTING OR CANCELLING A PROGRAMMED SWITCH ON TIMER ON.........................................................................................................13
SETTING OR CANCELLING A PROGRAMMED SWITCH OFF TIMER OFF......................................................................................................13
ACTIVATING / DEACTIVATING THE EXTENDED VENTILATION XFAN ..........................................................................................................14
ACTIVATING OR DEACTIVATING THE WIFI FUNCTION ONLY WITH WIFI DEVICE INSTALLED ............................................................14
ACTIVATING / DEACTIVATING THE NIGHTTIME COMFORT FUNCTION........................................................................................................15
SETTING OR REMOVING THE BUTTON LOCK ........................................................................................................................................................... 16
SETTING THE UNIT OF MEASUREMENT......................................................................................................................................................................16
ACTIVATING / DEACTIVATING THE ANTIFREEZE FUNCTIONS ...........................................................................................................................17
ACTIVATING OR DEACTIVATING THE ENERGY SAVING FUNCTION................................................................................................................. 17
REPLACING THE REMOTE CONTROL’S BATTERIES..................................................................................................................................................18
TABLE OF CONTENTS
COMPANY CERTIFICATIONS
SAFETY CERTIFICATIONS

ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
WIFI
1
2
3
5
7
9
11
4
6
8
10
12
1513
14
16
17
4
1. REMOTE CONTROL
• Some of the buttons of the remote control are
not used for the required air conditioner and are
therefore not described in these instructions.
Pressing of these buttons will not affect the
operation of the air conditioner.
• Check there are no obstructions between the
receiver and the remote control.
• The maximum distance between the IR receiver and
the remote control is 8 metres, to ensure the signal is
correctly received.
• Position the remote control at least 1 metre away
from TVs, radios, stereos, etc. There may be some
audio and video interference.
• Do not drop or throw the remote control.
• Do not let liquids enter the remote control, and do
not leave it in direct sunlight or in hot places.
• When the remote control sends a signal the symbol
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
WIFI
appears on the display, the receiver of the indoor
unit emits a sound to confirm reception of the signal.
Buttons available
on remote control
Index Function of the button:
1Switches the unit on or off
2
Increase or decrease the value of the active
function:
• External air
• Time
• Start-up timer
• Shut-down timer
3Operating mode selection
4Sets the fan speed
5Sets the operation of the motorised air
discharge fin (swing function)
6Activates or deactivates the IFEEL function
7Activates the HEALTH function or the AIR
function
8
Activates or deactivates the SLEEP function
(this function is applicable to the cooling
and heating modes). Once activated this
function will control the unit in order to
maintain an ideal temperature
(this temperature is automatically
calculated and cannot be set)
9Shows on the indoor unit display the
temperature set-point and the room or
outside air temperature
10 Activates or deactivates the quiet operation
11 Sets the time on the system clock
12 Activates, deactivates or changes the
programmed switch on or switch off timer
13 Activates or deactivates the maximum fan
speed (TURBO)
14 Activates or deactivates the display of
information of the indoor unit
15 Activates or deactivates the WIFI card
16 IR transmitter
17 Liquid crystal display

ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
WIFI
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
WIFI
5
Remote control display icons available
Index Functions represented by the icons:
Indicates the AUTOMATIC mode is active
Indicates the COOLING mode is active
Indicates the DEHUMIDIFICATION mode is
active
Indicates the VENTILATION mode is active
Indicates the HEATING mode is active
Indicates the SLEEP function is active
Indicates the room air and set-point
temperatures are active on the display of the
indoor unit
Indicates the status of the SWING (vertical)
function
Indicates that all the buttons of the remote
control are locked
Indicates that the IFEEL function was activated
Indicates the actual ventilation speed
Indicates the TURBO function is active (the fan
speed is forced by this function)
Indicates the setting has been transmitted to
the receiver located on the indoor unit
Indicates that the antifreeze function was
activates (min. temperature 8 °C)
Indicates that the air purifier function was
activated (Cold Plasma).
FUNCTION NOT AVAILABLE
Indicates that the AUTO QUIET quiet operation
was activated.
Indicates that the QUIET quiet operation was
activated.
Indicates the extended ventilation function is
active (only in cooling or dehumidification)
Indicates which temperature is shown on the
display of the indoor unit (indoor, outdoor
temperature or set-point temperature)
Indicates that the figures displayed next to the
icon represent the current system time
Indicates the system time, or the start and
switch off timer
Indicates if a timer is set for starting
Indicates if a timer is set for switching off
/Indicates the unit of measurement for the
temperature setpoints ( °C or °F)
WIFI
Indicates that the WIFI function was activated

6
2. FUNCTIONS AVAILABLE THROUGH THE
REMOTE CONTROL
SWITCHING THE UNIT ON OR OFF
By pressing the
ON/OFF
button it is possible to
switch the unit on or off. When off some information
is still displayed on the remote control: the operating
set-point of the last operating mode used, and switch
on timers programmed (ON) and any icons tied to the
function active during the last switch on of the unit
(enabling the display of the indoor unit, etc.) Once
switched on the unit uses the settings selected during
the last operating session.
Switching on
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
SETTING THE OPERATING SETPOINT
All the operating modes (except the automatic one)
require an room air temperature value to control to:
this is called the operating set-point.
If the unit is on (and the automatic mode is not
selected), pressing the and buttons allows
decreasing or increasing the operating set-point.
The set-point value is displayed in the central part of
the remote control’s display.
Operating set-point
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET

7
SELECTING AN OPERATING MODE
If the unit is on, pressing the
MODE
button allows
passing from one operating mode to the next, in this
sequence:
AUTO mode
COOL mode
DRY mode
FAN mode
HEAT mode
MODEON/OFF
FAN
CLOCK
X-FAN
TURBO SLEEP LIGHT
TEMP TIMER OFF
TIMER ON
The various operating modes have different features
and ranges:
• AUTOMATIC mode (AUTO): in this mode, the
remote control does not display any set-point value
and the fans speed is set to AUTO.
• COOLING mode (COOL): in this mode the user must
set the operating set-point and a fan speed; if the
room temperature is higher than the set value, which
can be seen on the display, the air conditioner will
continue to cool the air until the room temperature
will reach the setpoint value.
• DEHUMIDIFICATION mode (DRY): in this mode
the user must set the operating set-point but not
the fan speed (which remains fixed at minimum); if
the room temperature is higher than the set value,
which can be seen on the display, the air conditioner
will continue to dehumidify the air until the room
temperature will reach the setpoint value.
• VENTILATION mode (FAN): in this mode the user
must set only the fan speed. This mode provides no
heating or cooling but only uses the internal fan to
ventilate the space.
• HEATING mode (HEAT): in this mode the user must
set the operating set-point and a fan speed; if the
room temperature is lower than the set value, which
can be seen on the display, the air conditioner will
continue to heat the air until the room temperature
will reach the setpoint value.
Operating mode selection
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET

8
Setting the ventilation
speed
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
SETTING THE VENTILATION SPEED
Press the button
FAN
to modify the fan speed. In the
DRY mode operation (dehumidification), the fan will
automatically change to the minimum speed.
NB:
In addition to the standard speeds, another to
ventilation speeds are available:
• AUTO: ventilation speed that selects
autonomously the most suitable speed
depending on the room temperature
• TURBO: ventilation mode that adds further
speed to the maximum one.
AUTOMATIC speed
Minimum speed
Low speed
Medium speed
High speed
Maximum speed
ACTIVATING / DEACTIVATING THE TURBO FUNCTION
Press the button
TURBO
to activate or deactivate the
turbo function, ventilation at maximum speed.
The symbol on the display shows that the function
is active. This function is available only for the COOL
and HEAT modes.
The TURBO option makes it possible to reach the set
temperature as quickly as possible.
It is possible to deactivate it:
• by pressing the button
TURBO
• by changing the operation mode
• by changing the ventilation speed.
Activating / deactivating the
TURBO function
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET

9
SETTING THE DELIVERY FIN SWING
If the unit is on, pressing the
SWING
button allows
the activation of the swing function of the motorised
discharge fin. This fin varies the direction of the flow
of air into the ambient, on the basis of the selected
position.
With the unit on, pressing the
SWING
button allows the
setting of the following sequenced steps:
Continuous
swing (*)
Fixed
(Step 1)
Fixed
(Step 2)
Fixed
(Step 3)
Fixed
(Step 4)
Fixed
(Step 5)
Continuous
swing (*) Continuous
swing (*)
Continuous
swing (*)
, , =
To block the fin in a position during the continuous
swing mode, press the button
SWING
for at least 2
seconds and release it once the fin has reached the
desired position.
To remove the block, press again the button
SWING
.
Setting the stored
delivery fin
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
NB:
(*) although there are different icons for
activating the continuous swing, all activate the
same mode: continuous swing from the lowest
to the highest point.

10
ACTIVATING / DEACTIVATING THE I FEEL FUNCTION
With the remote control close to the user, it is possible
to control with precision the surrounding temperature.
Press the button
I FEEL
to activate the function.
The symbol on the display shows that the I FEEL
function is active. The remote control, by means of an
internal probe, detects the room temperature and
sends it to the indoor unit.
The remote control must always be within its
transmission range, facing the indoor unit of the air
conditioner, do not put in drawers or cover.
The remote control will update the reading and will
send the information to the air conditioner every 10
minutes and each time the user presses the buttons for
any change of settings.
NB:
The function uses the setpoint set by the user and
ensures a greater comfort if the remote control
is kept close to the user (within a maximum of 8
metres).
When this function is activated, keep the remote
control away from heat sources that could distort
the real reading of the room temperature.
Activating / deactivating the I
FEEL function
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
WIFI
Setting the Air purifier (Cold
Plasma) function
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
WIFI
AIR PURIFIER BUTTON COLD PLASMA
Capable of reducing pollutants breaking down their
molecules using electric discharges, causing the
splitting of the water molecules in the air into positive
and negative ions. These ions neutralise the molecules
of the gaseous pollutants obtaining products that
are normally present in clean air. The device is able
to eliminate 90% of the bacteria. The result is clean,
ionised air that has no bad odours.
Press more times the button to activate the
function as described below:
Air purifier (Cold Plasma)
Function not available

11
Displaying the room
temperature or operating
setpoint on the display
of the indoor unit
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
DISPLAYING THE ROOM TEMPERATURE OR THE
OPERATING SETPOINT OR OUTDOOR TEMPERATURE
ON THE INDOOR UNIT DISPLAY
Through the use of the remote control it is possible to
display the room temperature value read by the indoor
unit, or display the current operating set-point used by
the unit.
To view the desired temperature value, press more
times the button
TEMP
as explained below:
None
visualisation Set-point
Ambient
air
Ambient
external
NB:
The default display on the indoor unit’s display
is the operating set-point; the room temperature
value is displayed for 3 seconds after which
the display returns to the operating set-point.
To display the room temperature again it is
necessary to select the corresponding symbol on
the remote control.
On some models, the reading of the outside air (
) is not available; in these cases, the operation
setpoint will be displayed again ( ).

12
Setting the system time
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
SETTING A SYSTEM TIME
The remote control is fitted with an internal clock that
can display the current time; by pressing the button
CLOCK
the clock icon will start to flash (this flashing
will last 5 seconds, after this if no button is pressed you
automatically exit the time modification mode).
At start-up the default time is 12:00.
To adjust the time, press the button
CLOCK
and within 5
seconds the buttons or to increase or decrease,
during the adjustment, the time blinks.
If the buttons or are pressed for more than
2 seconds, the value of the minutes increases or
decreases by 10 minutes each 0.5 seconds.
At the end of the operation, press again
CLOCK
to
confirm the set time.
ACTIVATING / DEACTIVATING THE INDOOR UNIT’S
DISPLAY
The display on the indoor unit must be activated
using the remote control; to
activate the display of
information on the front panel of the indoor unit
press the button
LIGHT
on the remote control. The
display will show the symbol that indicates the
activation of the display on the indoor unit; Pressing
the button again deactivates the display.
Enabling the
display on the
indoor unit
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
WIFI

13
Setting a programmed
switch on
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
WARNING:
The units can manage at the same time a switch on
timer and a shut-down one, in order to offer a time
band within which the unit operation is possible.
SETTING OR CANCELLING A PROGRAMMED SWITCH
ON TIMER ON
The units possess a timer used to program switching on
by specifying the time that you want the unit to start.
Press the button
T-ON/T-OFF
, on the left-hand side, (warning:
this button has to different functions that are activated
by pressing on the left-hand side and on the right-hand
side) to enter the time programming mode (in this
mode the icon ”ON”, on the right-hand side of the time,
blinks) and pressing the buttons or it is possible to
set the start-up time.
Pressing the
T-ON/T-OFF
button on the left-hand side again
confirms the time and activates the timer programme. If
you want to cancel a programmed switch on, just press
the
T-ON/T-OFF
button to cancel the previous programming.
NB:
Once a programmed switch on is set, the
operating mode, the working set-point and fan
speed, will be the same as those present when
the unit stops.
Setting a programmed
switch on
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
SETTING OR CANCELLING A PROGRAMMED SWITCH
OFF TIMER OFF
The units possess a timer used to program switching
off by specifying the time that you want the unit to
deactivate.
Press the button
T-ON/T-OFF
, on the right-hand side, (warning:
this button has to different functions that are activated
by pressing on the left-hand side and on the right-hand
side) to enter the time programming mode (in this
mode the icon ”OFF”, on the right-hand side of the time,
blinks) and pressing the buttons or it is possible
to set the shut-down time. Pressing the
T-ON/T-OFF
button
on the right-hand side again confirms the time and
activates the timer programme. If you want to cancel
a programmed switch off, just press the
T-ON/T-OFF
button,
always on the right-hand side, to cancel the previous
programming.

14
NB:
The X-FAN function will remain active also after the
unit is switched off via the remote control. The icon
will remain visible on the display to indicate
that the function is active.
ACTIVATING / DEACTIVATING THE EXTENDED
VENTILATION XFAN
During the operation in cooling or dehumidification
mode the condensate caused by the humidity in the air
is formed on the heat exchanger within the unit.
The X-FAN function allows, when the air conditioner
is off, the ventilation to be extended for two minutes
after the unit is switched off, thereby drying the heat
exchanger.
If the unit is on (and the cooling or dehumidification
mode is selected), pressing the
FAN
button for at
least 2 seconds, allows the activation or deactivation
of this function. On the remote control display, the
icon
will appear or disappear to indicate if the
function is activated or deactivated.
Setting the extended ventilation
function
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
ACTIVATING OR DEACTIVATING THE WIFI FUNCTION
ONLY WITH WIFI DEVICE INSTALLED
Press the button
WIFI
to activate or deactivate the WIFI
device installed on the indoor unit.
The WIFI symbol on the display indicates that the
device is active.
To reset the WIFI device with the factory values, while
the unit is OFF, press at the same time (for at least one
second) the buttons
MODE
and
WIFI
.
Activating or deactivating the
WIFI function
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
WIFI

15
Setting Night-Time Comfort
function
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
NB:
The night time comfort function is deactivated
by switching off the unit, and on restarting will
not be active; this function can be activated at
any time.
ACTIVATING / DEACTIVATING THE NIGHTTIME
COMFORT FUNCTION
The night-time comfort function controls the air
conditioner in an optimal way during the night. The
following logic is applied:
• In cooling or dehumidification: the temperature
set-point is gradually increased to guarantee
maximum comfort combined with energy saving.
• In heating: the temperature set-point is gradually
increased to guarantee maximum comfort combined
with energy saving.
•
If the unit is on (except in automatic or ventilation
mode), pressing the
SLEEP
activates or deactivates the
night time comfort function. If the function is active the
icon is displayed on the remote control.
Night-time comfort SLEEP function 1
It can only be selected in the cooling mode and heating
modes.
• In cooling mode: the temperature increases by
1 °C after one hour, and by 2°C after two hours of
operation.
• In heating: the temperature decreases by 1 °C after
one hour, and by 2°C after two hours of operation.
Night-time comfort SLEEP function 2
It can only be selected in the cooling mode and heating
modes.
The SLEEP function 2 includes different operating
programs depending on the setpoint temperature.
Night-time comfort SLEEP function 3
It can only be selected in the cooling mode and heating
modes.
The SLEEP function 3 (DIY) makes it possible to
program the room temperature, hour by hour, up to a
maximum of 8 hours.
After selecting the SLEEP 3 mode , keeping pressed
the button TURBO for several seconds, the temperature
on the remote control display will start blinking.
At this point it is possible to program the desired
temperatures as in the example table here (to confirm
the temperature and move to the next hour setting,
press again the button TURBO):
set temperature 18 °C
set temperature 19 °C
set temperature 20 °C
set temperature 21 °C
set temperature 22 °C
set temperature 23 °C
set temperature 24 °C
set temperature 25 °C

16
Keyboard lock
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
SETTING OR REMOVING THE BUTTON LOCK
Press at the same time the buttons and to lock
and unlock the keyboard.
This function prevents involuntary changes to the
settings.
The icon on the remote control’s display shows that
the keypad of the remote control is locked.
Setting the unit
of measure
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
SETTING THE UNIT OF MEASUREMENT
The unit can display the temperature values in °C or in
°F. To change the unit of measurement simultaneously
press the and
MODE
buttons with the unit switched
off.
The temperature value on the remote control’s display
is automatically converted.

17
Activating or deactivating the
antifreeze function
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
ACTIVATING OR DEACTIVATING THE ENERGY SAVING
FUNCTION
The ENERGY SAVING function makes it possible to reach
the set temperature with lower energy consumption.
In the COOLING function mode
Press at the same time the buttons
TEMP
+
CLOCK
to set
the ENERGY SAVING function.
On the remote control display, the icon
will appear
or disappear to indicate if the function is activated or
deactivated.
Activating or
deactivating the
energy
saving function
ON/OFF
TURBO
CLOCK
T-ON/T-OFF
TEMP
SLEEP
I FEEL
SWING
FAN
MODE
LIGHT WIFI
QUIET
ACTIVATING / DEACTIVATING THE ANTIFREEZE
FUNCTION
The antifreeze function is only available in heating
mode. This function makes it possible to keep an
operation setpoint in heating mode equivalent to 8°C,
ensuring thus that the room temperature does not go
below this threshold.
If the unit is one and the heating mode is selected,
pressing the buttons
TEMP
+
CLOCK
will activate or
deactivate the antifreeze function.
On the remote control display, the icon
F
A
N
T
U
R
B
O
ON/OFF
MODE
I FEEL
T-ON/T-OFF
TEMP
CLOCK
LIGHT
X-FAN
SLEEP
will appear
or disappear to indicate if the function is activated
or deactivated
and the temperature will automatically
be set to .

18
NB:
• Remove the batteries if the remote control is
not used for extended periods.
• The remote control can emit a signal up to a
maximum distance of 8 metres.
• The unit can be affected by signals
transmitted by remote controls for
televisions, video recorders, or other devices
used in the same room.
WARNING:
• In the event of loss or damage of the remote
control the unit can be started and stopped
using the manual emergency button (if present
on the outdoor unit).
REPLACING THE REMOTE CONTROL’S BATTERIES
To replace the batteries of the infra red remote control
proceed as follows:
1. Open the battery cover by sliding it in the direction
of the arrow.
2. Remove the old batteries
3. Insert new alkaline high performance LR03 (AAA)
1.5V batteries (penlight) batteries, being careful not
to invert the polarity.
4. Close the battery cover.
1
+
-
+
+
+
-
-
-
2
+
-
+
+
+
-
-
-
3
4

19

AERMEC S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 0442 633111 - Fax +39 0442 93577
SCARICA L’ULTIMA VERSIONE: DOWNLOAD THE LATEST VERSION: TÉLÉCHARGER LA DERNIÈRE VERSION:
BITTE LADEN SIE DIE LETZTE VERSION HERUNTER: DESCARGUE LA ÚLTIMA VERSIÓN:
SCARICA L’ULTIMA VERSIONE: DOWNLOAD THE LATEST VERSION: TÉLÉCHARGER LA DERNIÈRE VERSION:
http://www.aermec.com/qrcode.asp?q=13734 http://www.aermec.com/qrcode.asp?q=13752 http://www.aermec.com/qrcode.asp?q=13753
BITTE LADEN SIE DIE LETZTE VERSION HERUNTER: DESCARGUE LA ÚLTIMA VERSIÓN:
http://www.aermec.com/qrcode.asp?q=13754 http://www.aermec.com/qrcode.asp?q=13755
Table of contents
Other AERMEC Remote Control manuals
Popular Remote Control manuals by other brands

Scientific Atlanta
Scientific Atlanta AllTouch AT8400 user guide

LEGRAND
LEGRAND Wattstopper LMRH-105 installation instructions

JR
JR XP9303 instruction manual

Universal Remote Control
Universal Remote Control Automator URC-200 owner's manual

MAXHUB
MAXHUB RC01 user manual

Satechi
Satechi X-pointer SMART user manual

Remote Control Systems
Remote Control Systems TITAN-TRACKSIDE-3 instruction manual

Aeware
Aeware IRMT-4 user manual

Samlexpower
Samlexpower 900-RC Instructional manual

Califone
Califone Got It! owner's manual

BMW Motorrad
BMW Motorrad DWA 5 Supplementary Rider's Manual

Chamberlain
Chamberlain Clicker KLIK1U user guide