manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Air Delights
  6. •
  7. Dispenser
  8. •
  9. Air Delights AutoFresh LCD User manual

Air Delights AutoFresh LCD User manual

INSTALLATION INSTRUCTIONS
AutoFresh™LCD
Aerosol Dispenser
7’
2.2m
Dispenser should be positioned
a minimum of 7' (2.2m) above
the floor for maximum
effectiveness and safety.
Mode
Press to scroll
thru options.
Adjust
Press to adjust
choice in
options.
Enter
Press to save choice
into program.
Air Neutralizer
Refill
Not included.
2 "D" Cell
Batteries
Not included.
Alkaline batteries are
recommended for
longer operation.
Position AutoFresh™
Dispenser over a wall stud and
secure with supplied screws.
TIME
REFILLDAY
ON
OFF
TO
AM PM
MODE
RESET
ADJUST
ENTER
TIME
REFILLDAY
ON
OFF
TO
AM PM
MODE
RESET
ADJUST
ENTER
TIME
REFILLDAY
ON
OFF
TO
AM PM
MODE
RESET
ADJUST
ENTER
Installation Instructions:
Wall Mounting:For effective operation,mount dispenser above eye level,a
minimum of 7 feet (2.2m) from floor to bottom of dispenser.Ensure location is
where moving air will disperse the Neutralle® Metered Aerosol throughout the
entire area.Position dispenser over wall stud and secure with the supplied screws
(2 screws).One AutoFresh™ dispenser treats up to 6,000 cubic feet (170m3).
Dispenser Overview of
Features & Switches
NOTE:This unit contains a special keyless locking feature.If you do not want this
locking feature,or wish to use the optional keyed lock,remove the locking pin from
this cabinet by depressing the locking tab top prong,inside the dispenser,and push
towards back of dispenser.This needs to be done before mounting to the wall.
NET WT 7 OZ
198.5 g
290 mL
T
R
A
N
S
F
O
R
M
S
&
E
L
I
M
I
N
A
T
E
S
F
O
U
L
O
D
O
R
S
,
FULLY GUARANTEED AGAINST DEFECTS
IN PARTS ANDWORKMANSHIP
T
E
N
Y
E
A
R
W
A
R
R
A
N
T
Y
Remember to fill out and mail
your warranty registration card.
Use of air neutralizers other thanTC
voids dispenser warranty.
Comes From Factory Preset For:
- 30 day refill cycle
- 24 hour-a-day operation,7 days a week
- "ME" Medium odor neutralizing setting (30 days)
- See directions for customized programming
Caution: Never stand directly in front of the dispenser when the outer switch is in
the ON-AUDIO or ON-QUIET position.When replacing metered aerosols,the outer
switch should be in the OFF position to avoid being sprayed in the face.
- Audio ON
- Audio OFF
- OFF
Selector Switch
(on the side)
ENTER
ENTER
ENTER
ENTER
Operation Instructions:
1. Open dispenser cover by depressing lock tab on right side of dispenser and pulling
cabinet forward .
2. Position outer selector switch to OFF.
3.Insert two "D" cell alkaline batteries.
4.Ensure there is no aerosol
refill installed to avoid
being sprayed in the face.
Position outer selector
switch to ON-AUDIO for
activating dispenser with
audio and liquid crystal
display.
The LCD will look like this:
This indicates that batteries are
charged, audio refill reminder is
activated, and there is 30 days
until refill needs to be changed.
5.If factory settings are satisfactory, proceed to step 6.
How to program dispenser beyond factory settings:
Remember, if you need to start over, press the "MODE" button until
you reach the beginning.
Mode A: Setting Odor Neutralizing Intensity
Begin by depressing the "MODE" button.The first choice is the factory
setting "ME" for medium.
"Lo" = Low is for low odor problems (sprays every 28 minutes).
"ME" = Medium is for normal situations (sprays every 14 minutes).
"HI"= High is for problem areas (sprays every 7 minutes).
Press the "ADJUST" button once to move to "HI" for high odor
problems or press "ADJUST" again to choose "Lo" for low odor
problems. Once you have decided "HI " "ME" or "Lo", press "ENTER" to
save setting. After you enter your choice, you will go back to the main
display, indicating the number of days remaining before changing
refill. If no other settings are desired, proceed to step 6.
Mode B: Setting Actual Time
Depress the "MODE" button again to bring up the clock.
Press the "ADJUST" button once to adjust the actual TIME in
increments of 10 minutes, noting "AM & PM" choice.You may hold
down the "ADJUST" button to quickly advance time by the hour. Press
"ENTER" to save setting.
Mode C: Setting Time of Operation
Upon entering the actual time, the next screen displayed is the
factory setting of "24" (operates all the time).
Pressing the "ADJUST" button once will show "12" to operate the
dispenser for 12 hours ON then 12 hours OFF. If you want this setting,
press "ENTER" to save this change. If not, press "ADJUST" once more
to display "24" and then press "ENTER" to keep setting.
If you selected "12", the next screen presented is the time to begin
the 12 hour operation. Press the "ADJUST" button once to adjust time
in increments of 10 minutes noting "AM & PM" choice.You may hold
down the "ADJUST" button to quickly advance time by the hour. Press
"ENTER" to save setting. This will take you back to the main display
indicating the number of days to refill.
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
TIME
REFILLDAY
ON
OFF
TO
AM PM
AM PM
TIME
TIME
REFILLDAY
ON
OFF
TO
AM PM
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
TIME
REFILLDAY
ON
OFF
TO
AM PM
Mode A:
Neutralizing
Intensity
Setting
*Mode B:
Actual
Time Set
*Mode C:
12 ON/12 OFF
Set Time to
Begin 12 HR
Operation
*Mode D:
Set Actual Day
Choose up to
2 days off during
the week
Factory
Settings
Display
Setting Flow Chart
ENTER
MODE
MODE
MODE
MODE
MODE
ADJUST
ADJUST
ADJUST
ADJUST ADJUST
ADJUST
ENTER
ENTER
ADJUST
ENTER
ENTER ENTER
ADJUST
ENTER
MODE
ADJUST
Remember this simple process:
1. Press to scroll thru options
2. Press to adjust choice in options
3. Press to enter choice into program
Repeat steps 1, 2 & 3 for each option available.
Odor Neutralizing Refill Life at
Intensity: Factory Settings:
HI 15 Days* (Sprays every 7 minutes)
ME 30 Days* (Sprays every 14 minutes)
LO 60 Days* (Sprays every 28 minutes)
*Actual refill life will vary depending on all options chosen.
Set real-time clock
within 10 minutes.
*Only change if you
want to use additional
program features.
Or, Ensure there is no
aerosol refill installed to
avoid being sprayed in
the face. Position outer
selector switch to ON-QUIET
for activating dispenser with
liquid crystal display only.
The LCD will look like this:
This indicates that batteries
are charged and there is
30 days until refill needs to be
changed.
Mode D: Setting Current Day and 1 or 2 Days Off of Operation
Press "MODE" button again.
Press the "ADJUST" button until the current day is shown and press
"ENTER" to save setting. Upon saving setting, Saturday "SA" will be
displayed to begin setting which days you want Off, up to 2 days. If you
want to operate all 7 days of the week, press "ENTER" 7 times.This will
bring you to the main display. Proceed to step 6.
If you want 1 day OFF, use "ENTER" to select the day OFF, press "ADJUST" to
change to OFF and press "ENTER" to save setting. Next, press "ENTER" until
you reach the main display. Proceed to step 6.
If you want a 2nd day OFF, press "ENTER" to select the day. Press "ADJUST"
to change to OFF and "ENTER" to save setting for 2nd day selected. Upon
changing and entering the 2nd day, you will automatically go to the main
display. Proceed to step 6.
To review or change your program, press "MODE" to scroll through your
settings.
6. Reset the refill spray timer by pressing the red "RESET" button and release
immediately. IMPORTANT: Do this every time the aerosol is replaced.
7. Stand to the side to avoid being sprayed
in the face. Place a Refill into the
dispenser. Close the AutoFresh™
dispenser cover.
TIME
REFILLDAY
ON
OFF
TO
AM PM
1-800-440-5556 •1-503-643-8224 (Fax) 11170 SW 5th Street, BEAVERTON, OR. 97005

Other Air Delights Dispenser manuals

Air Delights AutoJanitor User manual

Air Delights

Air Delights AutoJanitor User manual

Air Delights OneShot Installation and operating instructions

Air Delights

Air Delights OneShot Installation and operating instructions

Air Delights MICROBURST 9000 User manual

Air Delights

Air Delights MICROBURST 9000 User manual

Popular Dispenser manuals by other brands

Star CSD-2-H Series Installation and operation instructions

Star

Star CSD-2-H Series Installation and operation instructions

Cornelius Quest Bib Option Kit installation manual

Cornelius

Cornelius Quest Bib Option Kit installation manual

NSA ZCUT-870 instruction manual

NSA

NSA ZCUT-870 instruction manual

DrBrowns Insta-Prep AC262 Instructions for use

DrBrowns

DrBrowns Insta-Prep AC262 Instructions for use

KWC STRATOS STRX629 Installation and operating instructions

KWC

KWC STRATOS STRX629 Installation and operating instructions

Bartscher 103.065 instruction manual

Bartscher

Bartscher 103.065 instruction manual

Royal Catering RCSD-3A1 user manual

Royal Catering

Royal Catering RCSD-3A1 user manual

DEMA 302-1 Installation instruction

DEMA

DEMA 302-1 Installation instruction

lancer MAX II Operation manual

lancer

lancer MAX II Operation manual

BOWMAN SP-003 quick start guide

BOWMAN

BOWMAN SP-003 quick start guide

Franke F3D3S Service manual

Franke

Franke F3D3S Service manual

Henkel Loctite 98548 operating manual

Henkel

Henkel Loctite 98548 operating manual

Drinkpod 100 Series installation guide

Drinkpod

Drinkpod 100 Series installation guide

EURANEG SD4010 Original instruction manual

EURANEG

EURANEG SD4010 Original instruction manual

Hilti HTE-M 16 Original operating instructions

Hilti

Hilti HTE-M 16 Original operating instructions

U-Line UCDE215 User guide & service manual

U-Line

U-Line UCDE215 User guide & service manual

Graco PR70 Series manual

Graco

Graco PR70 Series manual

Delta Clean DZ6511 quick start guide

Delta Clean

Delta Clean DZ6511 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.