manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Airflow
  6. •
  7. Fan
  8. •
  9. Airflow iCON PCS User manual

Airflow iCON PCS User manual

Modules for SELV 12V Fan Range
Installation and Operating Guide
PCS - 72573603
PCTS - 72574204
DTS - 72682307
HTS - 72574202
PRTS - 72574203
PRHTS - 72574201
iCON SELV Fan Range Available Modules
Page 2 of 8
Page 3 of 8
Electrical installation
Page 4 of 8
Mechanical installation
Airflow iCON SELV 12V fans can be controlled by optional
control modules. For the SELV 12V range you can choose
between six modules.
* For blister pack add “B” at the end of part number.
SAFETY FIRST: ALWAYS ISOLATE THE FAN
UNIT FROM THE POWER SUPPLY BEFORE
DOING ANY WORK ON THE FAN/MODULE.
All electrical installation work to be carried out by an ap-
proved competent person in compliance with U.K. Building
Regulations and to the latest IET standards, or the appropri-
ate regulations in the country of installation. (for fan installa-
tion see the iCON SELV 12V Fan Range Installation and
Operating Guide).
Diagram A - module wiring with no external switching
(module functionality / pull cord activation only):
Diagram B - module wiring with external switching (live
trigger connection used):
To install the module in an iCON fan follow the instructions
below. See page 5 - 8 for instructional drawings.
1. Remove the iCON fan front cover (see page 5).
2. Lift the fan electrical terminal away from its mounting pillars
and position on the module connector pins. Tighten the two
screws with a suitable screwdriver. Ensure the leads are
under the module retaining cable clamp.
3. Fit the module at a slight angle into the fan housing, ensur-
ing that the locating slot is fully engaged in to the locating
block on the fan.
4. Push the module against housing, ensuring the module clip
holds it in place (clicks at the cable clamp). With iCON 15
& 30 the terminal will reposition back over mounting pillars.
Modules with pull cord: Ensure that the pull cord is properly
located within the cord slot at the bottom of the fan.
Modules with PIR control: Remove the oval logo cap fitted
at the bottom of the front cover of the fan. Replace it with
translucent lens supplied with the PIR module. Note: The
lens must be replaced in order for the PIR module to function
properly. Ensure the orientation of the lens is correct (i.e. the
lens should be flush with the surface).
Connecting mains cable into the module
Connect the 12V Power Supply Unit cable to the 3-way sup-
ply connector block (see wiring diagrams on page 3) ensur-
ing that the supplied cable clamp is fitted. Refit the front
cover.
Note: When using DTS module on initial connection the fan
will start immediately and continue running for the duration
set on the timer function of the module.
Certificate No. FM 00152
BS EN ISO 9001:2015
Certificate No. EM S 569454
BS EN ISO 14001:201 5
Part no.* Model Description
Wiring
diagram
72573603 PCS Pull cord (Manual on/off) A
72574204 PCTS Pull cord timer (Pull cord, Run on timer 1 - 30 min) A, B
72682307 DTS Delayed timer (Pull cord, 2 min delay, Run on timer 2 - 45 min) A, B
72574202 HTS Humidity timer (Pull cord, Run on timer 1 - 30 min, 40 - 90% RH) A, B
72574203 PRTS PIR timer (Motion sensor, Run on timer 1– 30 min, 40 - 90% RH) A, B
72574201 PRHTS PIR humidity timer (Motion sensor, Run on timer 1 - 30 min, RH
40 - 90%) A, B
Mechanical Installation
Page 5 of 8 Page 6 of 8
Module adjustment
Front Cover Removal
Page 7 of 8
Module
locating block
3-way supply
connector
Two module
connector pins
Module
locating slot
Cable entry
PIR lens
location
To remove front cover assembly, first make sure the fan is
off, isolated from the power supply and the iris shutter is
fully closed.
1. Undo the locking screw at the bottom edge of the cover
using a screwdriver.
2. Rotate the cover a few degrees anticlockwise until it clicks
out from the fittings.
3. Remove the cover by pulling it out.
To refit the cover, reverse the above procedure. The iris
shutter should be in closed position after refit. If not, wait
approximately 1 min after fan switch off allowing the actuator
to retract back in the closed position and then refit the cover
again.
3
1
2
iCON module
Module cable
clamp
Terminal block
fitting (pillars)
iCON module overview.
A module with Timer and/or Humidistat is supplied pre-set,
but may be adjusted by the installer. All adjustments must be
done using the supplied Adjustment Tool.
Humidity settings
The humidistat is factory pre-set at approx. 70% RH (relative
humidity). Adjusting the “% RH” towards 40% will result in fan
activation at lower humidity (more sensitive). Adjusting the
“% RH” towards “90%” will result in fan activation at higher
humidity (less sensitive).
Time settings
The Run on Timer is factory pre-set at approx. 15 min. Ad-
justing the “Timer” towards “MIN” will result in a timer overrun
decrease towards 1 or 2 minutes (depends on module).
Adjusting the “Timer” towards “MAX” will result in a timer
overrun increase towards 30 or 45 minutes (depends on
module).
Warranty
Applicable to units installed and used in the United Kingdom.
Airflow Developments Ltd guarantees the iCON range for
3 years (incl. modules) from date of purchase against
faulty material or workmanship. You can register your
warranty on-line (for more information check at
www.airflow.com). Warranty only covers the product, not a
reinstallation if required.
For detailed standard warranty terms and conditions see
our website or contact Customer Service.
Adjustment
tool
Timer control Humidistat
control
Humidistat
MIN = 40% RH
MAX = 90% RH
Timer
MIN = 1 or 2 min
MAX = 30 or 45 min
Module clip
© Airflow Developments Ltd.
Airflow Developments Limited reserve the right, in the interests of continuous develop-
ment, to alter specifications without prior notice. All orders are accepted subject to our
conditions of sale which are available on request.
www.airflow.com
UK Head-Office
AIRFLOW DEVELOPMENTS Ltd
Aidelle House, Lancaster Road
Cressex Business Park
High Wycombe
Buckinghamshire
HP12 3QP
United Kingdom
Tel: +44 (0) 1494 525252
Email: info@airflow.com
Web: www.airflow.com
Czech Republic
AIRFLOW LUFTTECHNIK GmbH
o.s. Praha
Hostýnská 520
108 00 Praha 10
Malešice
Czech Republic
Tel: +42 (0) 2 7477 2230
Email: info@airflow.cz
Web: www.airflow.cz
Germany
AIRFLOW LUFTTECHNIK GmbH
Wolbersacker 16
53359 Rheinbach
Germany
Tel: +49 (0) 222 69205 0
Email: inf[email protected]
Web: www.airflow.de
80000440 Issue 3 08/21

This manual suits for next models

11

Other Airflow Fan manuals

Airflow LOOVENT eco T User manual

Airflow

Airflow LOOVENT eco T User manual

Airflow Aura Smart User manual

Airflow

Airflow Aura Smart User manual

Airflow 7006A User manual

Airflow

Airflow 7006A User manual

Airflow Adroit DV50 User manual

Airflow

Airflow Adroit DV50 User manual

Airflow MaxAir 7105A User manual

Airflow

Airflow MaxAir 7105A User manual

Airflow 90001265 Operating manual

Airflow

Airflow 90001265 Operating manual

Airflow AIR 125-R User manual

Airflow

Airflow AIR 125-R User manual

Airflow Uno hab Manual

Airflow

Airflow Uno hab Manual

Airflow AV125T User manual

Airflow

Airflow AV125T User manual

Airflow 7106A User manual

Airflow

Airflow 7106A User manual

Airflow Duplexvent DV65 Entro-V User manual

Airflow

Airflow Duplexvent DV65 Entro-V User manual

Airflow AV 100 User manual

Airflow

Airflow AV 100 User manual

Airflow MV150 PECO User manual

Airflow

Airflow MV150 PECO User manual

Airflow Duplexvent MULTI-N User manual

Airflow

Airflow Duplexvent MULTI-N User manual

Airflow AFLR48 User manual

Airflow

Airflow AFLR48 User manual

Airflow iCON Series User manual

Airflow

Airflow iCON Series User manual

Airflow LA HABRA User manual

Airflow

Airflow LA HABRA User manual

Airflow 72687117 Installation guide

Airflow

Airflow 72687117 Installation guide

Airflow Breeze 3.1 User manual

Airflow

Airflow Breeze 3.1 User manual

Airflow QuietAir QT 100T User manual

Airflow

Airflow QuietAir QT 100T User manual

Airflow WHV-8 User manual

Airflow

Airflow WHV-8 User manual

Airflow iCON 30 Installation guide

Airflow

Airflow iCON 30 Installation guide

Airflow 8QRKDE User manual

Airflow

Airflow 8QRKDE User manual

Airflow Susurro 400 User manual

Airflow

Airflow Susurro 400 User manual

Popular Fan manuals by other brands

Fanimation STAFFORD FP8274 Series instructions

Fanimation

Fanimation STAFFORD FP8274 Series instructions

Maico FE 100 SG Mounting Instructions and Directions for Use

Maico

Maico FE 100 SG Mounting Instructions and Directions for Use

Pifco P51001 manual

Pifco

Pifco P51001 manual

ubbink Rolux installation instructions

ubbink

ubbink Rolux installation instructions

Brandson 305057 user manual

Brandson

Brandson 305057 user manual

EDM 33945 instruction manual

EDM

EDM 33945 instruction manual

oneConcept Hightower 2G manual

oneConcept

oneConcept Hightower 2G manual

AC Infinity CLOUDRAY user manual

AC Infinity

AC Infinity CLOUDRAY user manual

Matsui MF303W instruction manual

Matsui

Matsui MF303W instruction manual

Craftmade American Tradition AT52ET Specifications

Craftmade

Craftmade American Tradition AT52ET Specifications

Atlas fan company DIANE owner's manual

Atlas fan company

Atlas fan company DIANE owner's manual

Newlux WindPure Mist W500 Smart manual

Newlux

Newlux WindPure Mist W500 Smart manual

Casablanca UTOPIAN owner's manual

Casablanca

Casablanca UTOPIAN owner's manual

BLAUBERG Ventilatoren Wind Series Service instruction

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren Wind Series Service instruction

Holmes Blizzard HAOF87 owner's guide

Holmes

Holmes Blizzard HAOF87 owner's guide

Lindab Plexus Series Installation instruction

Lindab

Lindab Plexus Series Installation instruction

NuTone QTNLEDB instructions

NuTone

NuTone QTNLEDB instructions

Hunter 25745 Parts guide

Hunter

Hunter 25745 Parts guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.