
2-4
PRODUCT DATA SHEET
SM HJD DCI 1-A.1 GB
2.4 HJD024 DCI
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2)
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
Model Indoor Unit AWAU-HJD024-N11
Model Outdoor Unit AWAU-YBDE024-H11
deralFepiPfodohteMnoitallatsnI
stinUscitsiretcarahC Cooling Heating
Average
Capacity
(1)
)8,8-5,1(6,7)5,7-5,1(8,6Wk
3,68,6WkngisedP
SEER /SCOP
(2)
8,311,5W/W
AAssalcycneiciffeygrenE
hWknoitpmusnocygrenelaunnA 466 2321
Tbiv oC N/A -7
Tol oC N/A -15
zH/hP/VylppusrewoP 220-240V/Single/50Hz
52AgnitarrekaerbtiucriC
INDOOR
1xnafwolfssorCytitnauq&epytnaF
Fan speeds H/M/L RPM 1350/1150/1000 1350/1150/1000
Air flow
(3)
H/M/L m3/hr 960/800/670 960/800/670
External static
pressure 0aPxaM-niM
Sound power level
(4)
15/65/06)A(BdL/M/H
Sound pressure level
(5)
83/34/74)A(BdL/M/H
5,2rh/llavomererutsioM
61mmD.IebutniardetasnednoC
Dimensions WxHxD mm 1060x295x221
51gkthgieW
Package dimensions WxHxD mm 1125x360x295
81gkthgiewdegakcaP
stinutellaprepstinU 14 units per pallet
slevel7stinuthgiehgnikcatS
OUTDOOR
VEElortnoctnaregirfeR
retrevnICDyratoRniwTledom,epytrosserpmoC
1xlaixAytitnauq&epytnaF
058MPRL/HsdeepsnaF
0063rh/3mL/HwolfriA
Sound power level
(4)
96)A(BdL/H
Sound pressure level
(5)
95)A(BdL/H
Dimensions WxHxD mm 950x864x340
5,56gkthgieW
Package dimensions WxHxD mm 1140x510x930
37gkthgiewdegakcaP
tellaprepstinu4stinUtellaprepstinU
slevel2stinuthgiehgnikcatS
A014RepyttnaregirfeR
Refrigerant charge (standard connecting
tubing length) 3,2)m5(gk
Additional charge per 1 met 20m
Connections
between units
Liquid line In.(mm) 3/8"(9,53)
Suction line In.(mm) 5/8"(15,88)
03.xaM.mhtgnelgnibut.xaM
51.xaM.mecnereffidthgieh.xaM
Operation control type lortnocetomeR
WkstnemelegnitaeH
srehtO
Model Indoor Unit AWSI-HJD024-N11
Model Outdoor Unit AWAU-YBDE024-H11
Installation Method of Pipe Flared
Characteristics Units Cooling Heating
Average Warme
Pdesign(1) kW 6.8 6.3 6.3
SEER /SCOP (1) W/W 5.2 3.8 4.65
Energy efficiency class(1) AAA++
Tbiv oCN/A -3 2
Tol oCN/A -15 -15
Capacity Range
Nominal (Min.~Max.) kW 6.5 (1.6~7.2) 6.3 (1.6~7.6)
Power Input (2) Nominal (Min.~Max.) W1,800 (550~2,200) 2,200 (450~2,400)
Rated Current (2) Nominal (Min.~Max.) A8.0 (3.1~8.8) 9.9 (2.5~10.9)
Power supply V/Ph/Hz 220-240V/Single/50Hz
Circuit breaker rating A20
INDOOR
Fan type &quantity Cross flow x1
Fan speeds H/M/L RPM 1350 /1150 /1000
Air flow (3) H/M/L m
/hr 960 /800 /670
External static pressure Min.-Max. Pa 0
Sound power level (4) H/M/L dB(A) 60 /56 /51 /47
Sound pressure level (5) H/M/L dB(A) 47 /43 /38 /34
Moisture removal l/hr 2.8
Condensate drain tube I.D mm 16
Dimensions WxHxD mm 1060x295x221
Weight kg 15
Package dimensions WxHxD mm 1125x360x295
Packaged weight kg 18
Units per pallet units 14 per pallet
Stacking height units 7levels
OUTDOOR
Refrigerant control EEV
Compressor type, model Twin Rotary DC Inverter
Fan type &quantity Axial x1
Fan speeds RPM 250-800(continuous)
Air flow Max. m3/hr 2,750
Sound power level(4) Nom. dB(A) 67
Sound pressure level(5) Nom. dB(A) 55
Dimensions WxHxD mm 900x700x340
Weight kg 61
Package dimensions WxHxD mm 985x730x435
Packaged weight kg 63.5
Units per pallet Units 6units per pallet
Stacking height units 2levels
Refrigerant type R410A
Refrigerant charge (standard tubing length) kg(7.5m) 1.55
Additional charge per 1m gr/m 7.5m < 0gr < 30m < 30gr per 1m < 70m
Connections
between units
Liquid line In.(mm) 3/8"(9.53)
Suction line In.(mm) 5/8"(15.9)
Max.tubing length m. Max.30
Max.height difference m. Max. 15
Operation control type Remote control
Heating elements kW BH 70W -optional
(1) Rating conditions in accordance with EN14825-2012.
(2) Rating conditions in accordance with EN14511-2011.
(3) Airflow in ducted units at nominal external static pressure.
(4) Sound power in ducted units is measured at air discharge (In duct).
(5) Sound pressure level measured at 1.0 meter distance from unit.
2.5
30
2.5
2
Model Indoor Unit AWSI-HJD030-N11
Model Outdoor Unit AWAU-YBDE030-H11
Installation Method of Pipe Flared
Characteristics Units Cooling
Heating
Average Warme
Pdesign(1) kW 7.5 8.6 8.6
SEER / SCOP (1) W/W 5.2 3.8 4.65
Energy efficiency class(1) A A A++
Tbiv oC N/A -3 2
Tol oC N/A -15 -15
Capacity Range
Nominal (Min.~Max.) kW 7.5 (2.0~9.0) 8.6 (2.0~9.5)
Power Input (2) Nominal (Min.~Max.) W 2,230 (550~3,100) 2,530 (550~3,100)
Rated Current (2) Nominal (Min.~Max.) A 8.2 (3.1~12.0) 10.7 (2.5~12.0)
Power supply V/Ph/Hz 220-240V/Single/50Hz
Circuit breaker rating A 20
INDOOR
Fan type & quantity Cross flow x 1
Fan speeds H/M/L RPM 1300 / 1050 / 910
Air flow (3) H/M/L m
/hr 1300 / 1100 / 950
External static pressure Min.-Max. Pa 0
Sound power level (4) H/M/L dB(A) 62 / 58 / 55
Sound pressure level (5) H/M/L dB(A) 54 / 50 / 47
Moisture removal l/hr 3.2
Condensate drain tube I.D mm 16
Dimensions WxHxD mm 1310x322x2401
Weight kg 23
Package dimensions WxHxD mm 1420x440x380
Packaged weight kg 26
Units per pallet units 12 per pallet
Stacking height units 6 levels
OUTDOOR
Refrigerant control EEV
Compressor type, model Twin Rotary DC Inverter
Fan type & quantity Axial x 1
Fan speeds RPM 200-850(continuous)
Air flow Max. m3/hr 3,400
Sound power level(4) Nom. dB(A) 68
Sound pressure level(5) Nom. dB(A) 56
Dimensions WxHxD mm 900x860x340
Weight kg 66
Package dimensions WxHxD mm 985x905x435
Packaged weight kg 68.5
Units per pallet Units 6 units per pallet
Stacking height units 2 levels
Refrigerant type R410A
Refrigerant charge (standard tubing length) kg(7.5m) 1.55
Additional charge per 1m gr/m 7.5m < 0gr < 30m < 30gr per 1m < 70m
Connections
between units
Liquid line In.(mm) 3/8"(9.53)
Suction line In.(mm) 5/8"(15.9)
Max.tubing length m. Max.30
Max.height difference m. Max. 15
Operation control type Remote control
Heating elements kW BH 70W - optional
(1) Rating conditions in accordance with EN14825-2012.
(2) Rating conditions in accordance with EN14511-2011.
(3) Airflow in ducted units at nominal external static pressure.
(4) Sound power in ducted units is measured at air discharge (In duct).
(5) Sound pressure level measured at 1.0 meter distance from unit.