Alcad Mont Blanc CAD-704 User manual

- 13 -
CAD-704
Mont Blanc
DIGITAL PROGRAMMABLE AMPLIFIER
■5 Inputs
■Auto-scan function
■Selectable LTE 700 5G / 800 4G SAW filters
■Up to 64 high selectivity filters with ACG
■Converts up to 32 single channels
■24 Digits LCD display
■Zamak die casting chassis
High selectivity programmable compact headend to
digitally filter, convert and equalize DVB-T/T2
channels.
The built-in high output amplifier allows the use in
small or medium buildings installation.
CODE
9040145
MODEL
CAD-704
Number of inputs
2 x UHF
2 x UHF/BIII/DAB
1 x FM/BI
Frequency range
MHz
UHF (470..694/790/862 MHz)
BIII/DAB (170..240 MHz)
FM/BI (40..108 MHz)
Programmable filters
32
Number of channels per filters
1..2
Input level
dBµV
UHF 40..110
BIII/DAB 40..110
FM/BI 35..90
Input attenuator
dB
UHF 0..-20
BIII/DAB 0..-20
FM/BI 0..-20
AGC range
dB
40
Selectivity
dB
35 @1MHz
Interstage attenuator
dB
0..-20
Gain
dB
UHF 40
BIII/DAB 50
FM/BI 40
Max output level
dBµV
120 (IM3 DIN 45004B -60 dBc)
Noise figure
dB
<6
Return loss in/out
dB
>12
Test output
1 (-30dB)
USB connector
USB 1.0/2.0 Type B
Output voltage
12V / 24V 100 mA
Mains voltage
230 VAC +/-20% 16W Max.

- 14 -
(External power supply DC 20V 2.25A)
Operating temperature
ºC
-5..50
Dimensions
mm
192 x 217 x 37
Safety instructions
■Do not expose the amplifier to extreme temperatures.
■Place the amplifier in a dry and well-aired location.
■Install the unit on a vertical wall, or in a waterproof cabinet to a minimum IP55 rating, and
fix it safely using the special through holes supports.
Do not place the equipment where water can drip or splash onto it. Do not place objects
containing liquid, such as glasses, on the equipment. Do not place sources of naked flame,
such as burning candles, on the equipment. Do not block the ventilation slots of the equipment
with objects such as newspapers, curtains, etc. When installing the equipment, leave some
free space around it to provide adequate ventilation. Install the equipment in such a way that
the mains supply plug or the connector of the equipment can be easily reached.
IMPORTANT!
Use only the power pack supplied together with the amplifier. The use of other power
packs can cause malfunctioning and irreversible damages which will invalidate any
warranties.
Connections Schematic
Installation and start-up
■Connect an earth wire to grounding clamp
■Connect the TV aerials to the amplifier's inputs

- 15 -
■Terminate the unused inputs with 75Ω loads
■Connect the power supply unit and then connect the amplifier to the mains plug
Programming via display
Programming corresponding to hardware 3.1 and firmware 1.4.
1. Press ↵to activate the display
2. Press
↵
for three seconds to enter the programming
menu
The display will go out after 3 minutes if inactive, but the menu will remain open on the last
selected function. Press any key to resume to continue.
Password protection
When a password has been set, the password must be
entered before accessing the programming menu. To enter
the password press the keys ▲▼ then press
↵
to confirm
each password number.
Automatic channel research and memorization
AUTO-SCAN
The AUTO-SCAN function will scan the UHF band in input 1 and the BIII band in input 2.
The remote power is preset to OFF. It can be changed to ON in the INPUT V/U 1 and INPUT
V/U 2 menu. The remote power voltage is preset to 24V in the ADVANCED menu. The AUTO-
SCAN threshold is preset to 50dBµV in the ADVANCED menu. The LTE filter is preset to 5G
LTE700 in the ADVANCED menu.
To start the automatic programming, AUTO-SCAN, place
the pointer _below AUTO. Press
↵
to proceed. The
amplifier will start scanning the channels of the UHF band
on input [1] and the III band on input [2].
To stop the AUTO-SCAN procedure press ↵for 5 seconds.
ALCAD
. CAD-704 .
PASSWORD?
PSW: 000
TUNING
AUTO MAN
DC : OFF
>GAIN: 20dB
Function
selector
Pointer to scroll
figures
Keys for browsing
the menu
Key to confirm

- 16 -
Wait for the AUTO-SCAN procedure to end, which
depends on the number of channels received from the
antennas.
When the AUTO-SCAN procedure is completed the
display will show the output level depending on the
number of channels automatically saved. Press
↵
to
confirm and complete the procedure. To change the output
level press the keys ▲▼ then press
↵
to confirm.
If required, it is possible to adjust the output slope. Select
SLP and press
↵
to confirm, select the slope of the slope
by pressing the ▲▼ keys and press
↵
to confirm.
Setting higher output levels than the one obtained through the AUTO-
SCAN could reduce the quality of the received signals.
Manual programming
To start the manual programming, position the pointer
_
on MAN through the ▲key and press
↵
to continue.
FM/BI INPUT
Press ↵to enter the menu to set the FM/BI input
parameters.
FM/BI OUTPUT VOLTAGE
Press
↵
to start the pointer
_
to scroll options then press
▲▼ to select ON or OFF to enable the remote power
supply on this input. Press
↵
to confirm.
The remote power suppy is set on 24V. It can be changed
to 12V in the ADVANCED menu.
FM/BI GAIN
Adjustable from 0 to 30 dB
Position the function selector
>
on GAIN and press
↵
to
start the pointer _
to scroll options, select the desired
output level through the keys ▲▼ and press
↵
to confirm.
TUNING
> > >
OUTPUT
>LEV:110dBuV
OUTPUT
>SLP: 10dB
TUNING
AUTO MAN
INPUT FM/BI
INPUT FM/BI
>DC : OFF
DC : ON
>GAIN: 20dB

- 17 -
Position the function selector
>
on INPUT FM/BI and press
↵
to go back to the main menu.
INPUT VHF-UHF [1]
To set the INPUT V/U 1 parameters press ↵to enter the
menu.
Available channels:
BIII E5..E13 – DAB
UHF 21..48 with LTE700 5G filter
UHF 21..60 with LTE800 4G filter
UHF 21..69 without LTE filter
The input can be configured as BIII/DAB or UHF. Once a
filter is selected in BIII/DAB or UHF, the rest of the filters
must be from the same band.
The LTE filter is preset to 5G LTE700. It can be changed in
the ADVANCED menu.
In any position of the menus INPUT U/V 1, INPUT U/V 2, INPUT U3 or INPUT
U 4 press the keys ▲▼ at the same time to go back to main menu.
OUTPUT VOLTAGE
Press ↵to start the pointer _to scroll options then press
▲▼ to select ON or OFF to enable the remote power
supply on this input. Press
↵
to confirm.
The remote power supply is set on 24V. It can be changed
to 12V in the ADVANCED menu.
INPUT GAIN
Adjustable from 0 to 20 dB
Position the function selector
>
on GAIN and press
↵
to
start the pointer _
to scroll options, select the desired
output level through the keys ▲▼ and press
↵
to confirm.
With input power from 75 dBμV, so as not to degrade the channels, reduce
the gain of the preamplifier. Typical values of gain adjustment:
•Power up to 70 dBμV adjust the gain to 20 dB
•Power 80 dBμV adjust the gain to 10 dB
•Power 90 dBμV adjust the gain to 0 dB
>INPUT FM/BI
INPUT V/U 1
INPUT V/U 1
>DC : OFF
DC : OFF
>GAIN: 20dB

- 18 -
SINGLE CHANNEL FILTER
Press
▲▼
to position the function selector
>
on ADD 1
CH and press
↵
.
To activate only the filtering function on a single channel
set the desired channel through the ▲▼ keys then press
↵
twice to confirm.
The L figure shows the input level of the selected MUX in
dBμV.
CHANNEL CONVERSION
To activate the filtering and conversion function on a
single channel set the desired channel through the ▲▼
keys then press
↵
to confirm the input channel.
Adjust the converted channel through the
▲▼
keys then
press
↵
to confirm.
Regardless of the selected LTE filter, output conversions up to the UHF
channel 69 are permitted.
TWO CHANNELS FILTER
To add a filter for two adjacent channels, press
▼
and
select ADD 2 CH. Press
↵
to confirm. Select the first
channel with the ▲▼
keys. The second channel will
automatically appear in second position. Press
↵
to
confirm.
DELETE FILTER
Position the function selector
>
on the channel filtering or
conversion to be deleted using ▲▼ then press
↵
for five
seconds.
GAIN: 20dB
>ADD 1 CH
GAIN: 20dB
>21->21 L 65
GAIN: 20dB
>21->21 L 65
GAIN: 20dB
>36->36 L 65
GAIN: 20dB
>36->41 L 65
GAIN: 20dB
>21<>22 L 65
ADD 1 CH
>ADD 2 CH
CH DELETED

- 19 -
MAIN MENU
To go back to the main menu, select INPUT V/U 1 and
press
↵
to confirm.
In any position of the menus INPUT U/V 1, INPUT U/V 2, INPUT U3 or INPUT
U 4 press the keys ▲▼ at the same time to go back to main menu.
INPUT VHF-UHF [2]
To set the INPUT V/U 2 parameters, press ↵to enter the
menu.
Available channels:
BIII E5..E13 – DAB
UHF 21..48 with LTE700 5G filter
UHF 21..60 with LTE800 4G filter
UHF 21..69 without LTE filter
The input can be configured as BIII/DAB or UHF. Once a
filter is selected in BIII/DAB or UHF, the rest of the filters
must be from the same band.
The procedures described for input 1 apply to all settings.
INPUT UHF [3]
To set the INPUT U 3 parameters, press
↵
to enter the
menu.
Available channels:
UHF 21..48 with LTE700 5G filter
UHF 21..60 with LTE800 4G filter
UHF 21..69 without LTE filter
The procedures described for input 1 apply to all settings.
INPUT UHF [4]
To set the INPUT U 4 parameters, press ↵to enter the
menu.
Available channels:
UHF 21..48 with LTE700 5G filter
UHF 21..60 with LTE800 4G filter
UHF 21..69 without LTE filter
The procedures described for input 1 apply to all settings.
>INPUT V/U 1
DC : OFF
INPUT V/U 2
INPUT U 3
INPUT U 4

- 20 -
OUTPUT LEVEL
Adjustable from 93 to 113 dBμV
Press
▼
to select the menu OUTPUT and press
↵
to
confirm and check the selected output level.
To adjust the output level press ↵and change the figure
where the pointer is positioned, to the required level. Press
↵
to confirm.
SLOPE ADJUSTING
Adjustable from 0 to 10 dB
If required, it is possible to adjust the output slope. Select
SLP and press
↵
to confirm, select the slope of the slope
by pressing the ▲▼ keys and press
↵
to confirm.
To go back to the main menu, select OUTPUT and press ↵
to confirm.
ADVANCED SETTINGS
Press
▼
to select the menu ADVANCED and press
↵
to
confirm.
In any position of the ADVANCED menu press the keys ▲▼ at the same time
to go back to main menu.
LTE FILTER
LTE Filter adjustable 800 4G, 700 5G or OFF
Press
↵
and the ▲▼ keys to select the SAW filter LTE
800-4G, 700-5G or OFF. Press again
↵
to confirm.
OUTPUT
OUTPUT
>LEV:110dBuV
OUTPUT
>LEV:110dBuV
OUTPUT
>SLP: 10dB
>OUTPUT
LEV:110dBuV
ADVANCED
ADVANCED
>LTE: 4G

- 21 -
LTE Filter 800-4G - UHF channels 21..60
LTE Filter 700-5G - UHF channels 21..48
LTE Filter OFF - UHF channels 21..69
OUTPUT VOLTAGE
Select the DC voltage setting function and press ↵, press
the ▲▼ keys to select the 12V or 24V tension then press
↵
to confirm.
PROTECTION PASSWORD
Select PSW and press
↵
, press the
▲▼
keys to select the
first figure from the right. Press
↵
to confirm. Repeat for
the other figures and press
↵
to confirm.
To remove the protection password, select 000.
AUTO-SCAN THRESHOLD
Adjustable from 45 to 90 dBμV
Select THR, the AUTO-SCAN miminum threshold function
and press
↵
. Use the ▲▼ keys to select the required value
and press
↵
to confirm.
ADVANCED
>LTE: 5G
ADVANCED
>LTE: 4G
LTE: 5G
>DC: 12V
LTE: 5G
>DC: 24V
DC: 24V
>PSW: 000
DC: 24V
>PSW: 000
PSW: 000
>THR: 50dBuV
PSW: 000
>THR: 50dBuV

- 22 -
RESET
Select the RESET function and press ↵to enter a second
safety menu RESET?
If you wish to cancel the operation select NO by pressing
▼then press
↵
to confirm.
If you want to cancel all setting and restore the original
settings, confirm YES by pressing
↵
. The display will show
RESET OK for a few second to confirm the operation.
SERIAL NUMBER
Select SNBR. The number displayed on the right is the
univocal serial number of the product.
EXIT
To close the procedure select EXIT and press
↵
. Select YES
by pressing the ▲▼ keys and press
↵
to confirm.
If you wish to cancel the operation, select NO by pressing
▼then press
↵
to confirm and carry on your setting
procedure.
Windows & Android applications
From the download area in our website www.alcadelectronics.com it is possible to download
a free PC compatible software to operate the amplifier from your PC. It also allows to save
and load configurations.
Hardware requirements
PC Windows compatible with USB interface
Processor 800MHz or more
256MB RAM
USB A-B cable
Software minimum requirements
Windows 7 or more recent operating system, Microsoft Framework .NET 3.5 or higher and
langpack (free download from Microsoft website).
Installation procedure
Close all the active applications (included antivirus programs)
Start the Setup.exe program
THR: 50dBuV
>RESET
RESET?
YES NO
RESET OK
RESET
>SNBR: 00001
EXIT
EXIT
YES NO

- 23 -
Follow the guided procedure until the installation is completed
The program needs the Framework.NET 3.5 which is usually already installed on the PC. If it
is not installed, Framework.NET can be freely downloaded from the Microsoft website.
Technical Information
The product is in compliance with the Radio Equipment Directive RED 2014/53/EU, The Low
Voltage Directive LVD 2014/35/EU and the Risk of Hazardous Substances Directive RoHS
2011/65/EU, so it shows the CE mark.
Class A
This product meets the more stringent screening requirements according to EN 50083-2,
quality grade A.
Other manuals for Mont Blanc CAD-704
1
This manual suits for next models
1
Table of contents
Other Alcad Amplifier manuals

Alcad
Alcad Mont Blanc 904 Series User manual

Alcad
Alcad 904 series User manual

Alcad
Alcad AI-131 User manual

Alcad
Alcad Mont Blanc CAD-704 User manual

Alcad
Alcad 911 Series User manual

Alcad
Alcad AL-100 User manual

Alcad
Alcad AM-913 User manual

Alcad
Alcad AM-270 User manual

Alcad
Alcad 903 Series User manual

Alcad
Alcad AM-173 User manual