WARNING
ALWAYS disconnect the machine from Electrical
power, Water, Steam and all other connected sup-
plies during installation, before attempting any serv-
ice, replacing parts and maintenance.
If the machine is not equipped with means to isolate
them from all energy sources (e.g. water, electricity,
steam, compressed air), than such means must be
part of the fixed installation external to the machine.
Such isolators shall be clearly identified. They shall
be capable of being locked if reconnection could en-
danger persons.
After the energy source is disconnected, follow the
install procedure to safely, dissipate any remaining
or stored energy in the circuits of the machine.
Use machine only for its intended purpose, suitable
laundry textiles. Never wash/dry/iron something else
like polymers, machine parts, automotive parts or
other ferro materials in the machine. This could re-
sult in serious injury and machine damage.
In case the machine is provided with shipping bra-
ces, they must be removed prior to putting into serv-
ice. See Install instruction for safely remove them.
Sharp edges can cause personal injury. Wear safety
glasses and gloves, use proper tools and provide
lighting when handling sheet metal parts.
WARNING
Failure to do so may result in conditions which can
produce serious injury, death and/or property dam-
age.
WARNING
The washer is provided with Air vents wherefrom Va-
pors can escape! Do not connect or cover them!
Automatic door-lock unlocking devices must not be
utilized or installed on machines that are fitted with a
drain pump or reverse function drain valve.
The new hose sets supplied with the appliance are to
be used. Old hose sets should not be reused.
Electrical - Energy Prevention
WARNING
Machine must be hard-wired. Use copper conductors
only.
Refer to the Earthing (grounding) instructions in the
INSTALLATION manual for the proper grounding of
the machine. In event of malfunction, breakdown or
leakage current, grounding will reduce the risk of
electrical shock and serve as a protecting device by
providing a path of least resistance of electrical cur-
rent. Therefore, it is very important, and the respon-
sibility of the qualified installer to ensure the ma-
chine is adequately grounded at installation, follow-
ing all the national and local requirements.
If there are other washers or appliances with ex-
posed conductive parts, which can touch simultane-
ously, make sure to make equipotential bonding be-
tween all these appliances. The external protective
terminal for this purpose is located on the rear side
of the machine frame. The minimum protection con-
ductor's cross section depends on the supply cable
cross section of the appliance of the highest current
rating.
An individual branch circuit needs to be used for
each machine.
If the machine is not equipped with a supply mains
disconnecting device, means for disconnection all
poles must by incorporated in fixed wiring in accord-
ance with overvoltage category Ill conditions and the
relevant local wiring rules and must be located so
that it is easily accessible with the machine in place.
If disconnection is foreseen by means of a plug, it
must be placed and installed in such a way that an
operator can check from any of the points to which
he has access, that the plug remains removed. If this
is not possible, due to its installation, a disconnec-
tion with a locking system in the isolated position
shall be provided.
Dangerous voltages are present inside the machine.
Disconnect power from the machine before remov-
ing any cover and guards, and before attempting any
maintenance, troubleshooting or service procedures
or replacing parts.
To reduce the risk of an electric shock or fire, DO
NOT use an extension cord or an adapter to connect
the machine to the electrical power source.
The machine is not designed for use in IT networks.
Applicable measures need to be provided.
Safety Information
© Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
7 Part No. D1599ENR16