Installation Instructions
PTAC Condenser
BaffleKit
May 2003 A3495904
Installation
1.Rem ove gaskets from condenserside coverand dis-
card.
Gaskets
2.Place baffles with louvers directing airtoward center
ofunit. Attach with screws provided.
Screw Screw
Screw Screw
BaffleDirection
Description
The condenserbaffle kitis required when replacing
an existing package term inalunitand the original
outdoorgrille isnotm ade by the sam e m anufacturer.
These baffles are required to deflectdischarge air
away from the inlet,preventing recirculation ofhot
condenserair.
This kitis intended to be used with outdoorgrilles
having horizontallouvers.Ifthe outdoorgrille has
verticallouvers,contactthe m anufacturerofthe pack-
age term inalunitbeing installed.
NOTE:This kitis not to be used when the outdoor
grille is provided by the originalm anufacturerofthe
package term inalunit.
CAUTION
To prevent dam age to the unit due to
restricted air flow,rem ove any baffles
or deflectors ofany kind from the out-
door grille.
As a professiona l insta ller y ou ha ve a n
obligation to know the productbetterthan the
custom er.This includes allsafety precautions
and related item s.
Priortoactualinstallation,thoroughly fam iliarize
yourself with this Instruction Ma nua l. Pay
specialattention to allsafety warnings.Often
duringinstallationorrepairitispossibletoplace
yourselfin a position which is m ore hazardous
than when the unitis in operation.
Rem em ber,itisyourresponsibility toinstallthe
productsafely and to know itwellenough to be
able to instructa custom erin its safe use.
Safety is a m atterofcom m on sense...a m atter
ofthinking before acting.Mostdealers have a
listofspecific good safety practices...follow
them .
Theprecautionslisted inthisInstallation Manual
are intended as supplem entalto existing
practices. However,ifthere isa directconflict
between existing practices and the contentof
this m anual,the precautions listed here take
precedence.
Madein USA
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
ATTENTION INSTALLING PERSONNEL