Amensolar A5120 User manual

User Manual of Storage Lithium Battery
A5120 (Certificate Model: YNJB16S100KX-L)

Amensolar Lithium Battery A5120 User Manual
Manual Instruction
This user manual is the instructions for using 2U rack-mounted battery modules. Please read
this manual carefully before installing the battery, and follow the instructions during the
installation. For any confusion, please contact the manufacturer immediately for advice and
clarification.
CONTENTS
1. Safety Disclaimer ...........................................................................................................1
2. Product Introduction ...................................................................................................... 1
3. Specification ...................................................................................................................3
4. Interface .......................................................................................................................... 4
5. Battery Module Safety Processing Guide .....................................................................8
6. Installation ...................................................................................................................... 9
7. Safety precautions ........................................................................................................ 12
8. Abnormal Conditions and Fault Handling ..................................................................13
9. Emergency .................................................................................................................... 14
Legal statement .................................................................................................................14

Amensolar Lithium Battery A5120 User Manual
1
1. Safety Disclaimer
Users must read this user manual carefully and operate it according to the safety precautions
required by this user manual before installing, using and repairing the battery. Our company will
be responsible for nothing if it happens to any injuries and loses caused by improper
operations.
Attention
It may cause moderate injury or minor injury to human beings, or even damages to product
because of the danger caused by failure to operate as requirements.
Danger
It may cause fire or serious personal injury, or even death because of the danger caused by
failure to operate as requirements.
2. Product Introduction
AMENSOLAR A5120, a 2U rack-mounted battery module, is one of the new energy storage
products that can be used to support reliable power for a variety of equipment and systems. The
product is especially suitable for the application scenarios of high power, limited installation
space, limited bearing capacity and long cycle life. The battery module has a built-in BMS battery
management system that can manage and monitor battery information, including voltage, current,
and temperature. In addition, BMS can also balance the charge and discharge of the battery to
extend the cycle life. Multiple batteries can be connected in parallel to expand capacity and power
in parallel to achieve the requirements of greater capacity and longer power support time.
2.1 Product features
Lithium iron phosphate battery, the weight is reduced by 40% compared with the same
specifications of lead-acid battery;
2U rack structure, it can be directly loaded into a 600*800mm standard network cabinet. It is
easy to be installed with the characteristics of easy maintenance, flexibility and versatility.
It is equipped with stacking pack accessories, which can be stacked without cabinets.
Battery pack shell with insulation coating metal sheet metal;
The power output and input terminal of the battery pack adopts a high-power quick-plug
connector, which supports hot swap.
The battery pack can be used in parallel with a maximum of 16 pieces and cannot be used in
series.
Low self-discharge, no memory effect, shallow charge and shallow discharge performance is
better.
BMS uses professional battery management chip, ARM low power processor, more energy
saving.

Amensolar Lithium Battery A5120 User Manual
2
2.2 Function introduction
Support active and passive charging current limiting mode (maximum 20A);
Supports CAN / RS485 communication;
Built-in 4-channel temperature acquisition;
Support high and low temperature over-charge and over-discharge protection;
Support the battery balancing function;
Support for SOC calculation and calibration;
Support for two-level over-current protection;
Support the output short-circuit protection;
Support for polar reverse-connection protection;
Support for data storage;
Multiple automatic fault detection (sampling, MOS, battery failure).
2.3 Product Size

Amensolar Lithium Battery A5120 User Manual
3
3. Specification
ITEM
A5120
Certificate Model
YNJB16S100KX-L
Battery Type
LiFePo4
Mount Type
Rack Mounted
Rated Voltage (V)
51.2
Operating Voltage Range (V)
44.8~57.6
Floating Charge Voltage (V)
55±1
Capacity (Ah)
100
Energy (KWh)
5.12
Internal Resistance
≤50mΩ
Max Charge Current (A)
100
Rated Charge Current (A)
50
Max Discharge Current (A)
100
Rated Discharge Current (A)
50
Charging Temperature
0℃~+56℃
Discharging Temperature
-20℃~+56℃
Recommended Working Temperature
+10℃~+30℃
Storage Temperature
0-25℃ / 12 months
Relative Humidity
5% - 95%
Dimension (L*W*H mm)
Module: 448*600*90 (carton)
Installation: 487*600*90 (including handle)
Weight (KG)
41±1
Communication
External: CAN / RS485
Internal: RS485
PC upper computer computer: RS232
Enclosure Protection Rating
IP21
Cooling Type
Natural Cooling
Display Mode
Indicator Light
Cycles Life
≥6000
Recommend DOD
90%
Design Life
20+ Years (25℃@77℉)
Safety Standard
UL1973/CE/IEC62619/UN38.3
Max Number of Parallel
16

Amensolar Lithium Battery A5120 User Manual
4
4. Interface
4.1 Interface definition
❶
Power Indicator
❽
RS485 Interface
❷
Ground wire hole
❾
Power on/off
❸
Status Indicator
❿
Negative Terminal
❹
Alarm Indicator
⓫
Positive Terminal
❺
Battery Energy Indicator
⓬
Reset
❻
RS485 / CAN Interface
⓭
Dip Switch
Address
❼
RS232 Interface
⓮
Dry Contact
1Power Indicator
Always on after power on, and off after power is turned off.
2Ground wire hole
Battery module grounding.
3Status Indicator
Showing the power is on, the BMS is on / off
4Alarm Indicator
Battery fault indicator light, red indicates fault, green indicates normal.
5Battery Energy Indicator
Displaying the energy of battery, six indicators show the current power supply.
6RS485 / CAN Interface
RS485 / CAN communication interface: (RJ 45 port) communicate according to RS 485 / CAN
protocol.
RS485- -8P8C vertical RJ 45 socket
CAN- -8P8C vertical RJ 45 socket
RJ45 pin
Definition
RJ45 pin
Definition

Amensolar Lithium Battery A5120 User Manual
5
9、16
RS485-B1
1、2、3、6、8
NC
10、15
RS485-A 1
4
CANH
11、14
GND
5
CAN L
12、13
NC
7
GND
RS 485 / CAN Interface Definition
7RS 232 Interface
RS 232 Communication interface: (RJ 11 port) communicate according to RS 232 protocol and
the battery output information can be checked.
RS 232 Interface Definition
8RS 485 Interface
RS 485 Communication interface: (RJ 45 port) to communicate according to the RS 485 protocol,
read the battery information, and can also be used for multiple sets of lithium battery for parallel
communication.
RS485- -8P8C vertical RJ 45 socket
RS485- -8P8C vertical RJ 45 socket
RJ45 pin
Definition
RJ45 pin
Definition
1、8
RS485-B1
9、16
RS485-B1
2、7
RS485-A 1
10、15
RS485-A 1
3、6
GND
11、14
GND
4、5
NC
12、13
NC
RS 485 Integrated Communication Interface Definition
9Power on/off
Power switch: Turn on / off the entire battery pack.
10 Negative Terminal
11 Positive Terminal
Power terminal: use the cold terminal RNB 22-8, two pairs of terminals with the same function,
one connected to the battery module and the other in parallel to the other battery modules for
capacity expansion. For each battery module, each terminal can perform the charging and
discharge functions.
12 Reset
RS 232- -Use the 8P8C vertical RJ 45 socket
The RJ 11 pin
Definition
2
NC
3
send data
4
Accept the data
5
GND

Amensolar Lithium Battery A5120 User Manual
6
When the BMS is in sleep status, press the button (3~6s) then release, the BMS will be activated,
and the LED indicator will be continuously lit from "RUN" for 0.5 seconds.
When the BMS is active, press the button (3~6s) then release, the BMS will sleep and the LED
indicator will light from the lowest battery power light for 0.5 seconds.
When the BMS is active, press the button (6~10s) and release, BMS will reset, and all the LED
lights are on at the same time for 1.5 seconds.
13 Dip Switch Address
When multiple battery modules are connected in parallel, each battery module will have a
different address code, up to 15 addresses.
Note: In the following table, address 1 is he master, and the other addresses are the slave.
address
Dip Switch Address
1#
2#
3#
4#
1
on
off
off
off
2
off
on
off
off
3
on
on
off
off
4
off
off
on
off
5
on
off
on
off
6
off
on
on
off
7
on
on
on
off
8
off
off
off
on
9
on
off
off
on
10
off
on
off
on
11
on
on
off
on
12
off
off
on
on
13
on
off
on
on
14
off
on
on
on
15
on
on
on
on
14 Dry Contact
dry contact 1-PIN1 to PIN2: often open, low power closed.
Dry contact point 2-PIN3 to PIN4: normally open, closed during fault and protection.
4.2 LED Indicator
STATUS
Normal
Alarm
Protection
ON/
OFF
RUN
ALM
POW ER INDICATO R LED
DESCRIPTION
●
●
●
●
●
●
●
●
●
TURN
OFF
Sleep
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ALL OFF
STA NDBY
Normal
ON
FLASH1
OFF
Ac cor ding to bat ter y po wer
STANDYBY
Alarm
ON
FLASH1
FLASH3
Low voltage
CHARGE
Normal
ON
ON
OFF
Max power LED flashing
(flash twice, others are on
Alarm
ON
ON
FLASH3
Max power LED flashing
(flash twice). When
overcharging alarm, ALM
does not flash
Overcharge
protection
ON
ON
OFF
ON
ON
ON
ON
ON
ON
No Charging
Temperature,
over-current
protection
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
No Charging
DISCHARGE
Normal
ON
FLASH3
OFF
Ac cor ding to bat ter y po wer

Amensolar Lithium Battery A5120 User Manual
7
Alarm
ON
FLASH3
FLASH3
Low voltage
protection
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
No Discharging
Temperature,
over-current,
short-circuit
protection
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
No Discharging
FAI LU RE
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
No Charging/Discharging
4.3 BMS SOC Display
State
Charge
Discharge
SOC state
L6●
L5●
L4●
L3●
L2●
L1●
L6●
L5●
L4●
L3●
L2●
L1●
0-16.6%
off
off
off
off
off
flash
2
off
off
off
off
off
on
16.6-33.2%
off
off
off
off
flash
2
on
off
off
off
off
on
on
33.2-49.8%
off
off
off
flash
2
on
on
off
off
off
on
on
on
49.8-66.4%
off
off
flash
2
on
on
on
off
off
on
on
on
on
66.4-83%
off
flash
2
on
on
on
on
off
on
on
on
on
on
83-100%
flash
2
on
on
on
on
on
on
on
on
on
on
on
status
indicator
on
flash 3
4.4 LED Flash indication
Flash
lighting hours
stop time
flash 1
0.25s
3.75s
flash 2
0.5s
0.5s
flash 3
0.5s
1.5s
4.5 BMS Function
Protection and alarm
Management and monitoring
Charge / discharge to end
Battery balance
Charge over voltage
Intelligent charging mode
Charge / discharge over-current
Charging current limit
High / low temperature
Calculation of capacity retention
Short circuit
Administrator monitoring
Power cable reverse-connection
operation note

Amensolar Lithium Battery A5120 User Manual
8
5. Battery Module Safety Processing Guide
5.1 System topology
5.2 Label
5.3 Tool
To install the battery pack, the following tools may be required:
Phillips screwdriver
Cable pressurizer
voltmeter
Note: Use appropriate insulation tools to prevent accidental electric shock or short circuit. If not
available, cover the entire exposed metal surface of the available tool with insulating tape, except
for the tips.

Amensolar Lithium Battery A5120 User Manual
9
5.4 Safety wearing
It is recommended to wear the following safety equipment when handling the battery module.
insulating gloves
eye protector
safety shoe
5.5 Accessories
Item
Specifications
Quantity
Cabinet screws
M 6*16mm
4
Ground wire screw
M 5*6mm
1
User operation manual
A5120
1
Packing list
A5120
1
Warranty card
A5120
1
6. Installation
6.1 Connection instructions
Note: For safe operation and operation, when installation of the battery, a separate DC overcurrent
protector or a disconnected device is required. In some applications, disconnected device may not
be required, but overcurrent protector is still required.
Please refer to the typical amps in the table below for the required fuse or circuit breaker.
Ring terminal:
Warning! All wiring work must be done by qualified personnel.
Warning! The use of the appropriate cable to connect the battery is very important for system
security and effective operation. To reduce the risk of injury, use the following appropriate
recommended cable and terminals.
Recommended battery cable and terminal
battery
capacity
Cable size
Ring terminal
cable mm2
size
D(m m )
L (mm )
100A h
4AWG
22
8.4
33.5
6.2 Installation conditions
Make sure that the installation location meets the following conditions:
The area is completely waterproof.

Amensolar Lithium Battery A5120 User Manual
10
The floor is flat.
No flammable and explosive materials.
The ambient temperature is in the range of 0℃ to 50℃.
Temperature and humidity were maintained at a steady level.
There is very little dust and dirt in the area.
6.3 Installation instructions
Warning
If the environment temperature exceeds the operating temperature range, the battery module stops
working to protect itself. The best operating temperature range for the battery module is 0℃ to
50℃. Frequent exposure to harsh temperatures may degrade the performance and life of the
battery module.
A . Rack-mounted (optional)
1. Place the battery in the rack
2. Fixed the battery with two side clips
3. Connect the ground cable between the battery modules
4. Connect the communication cable between the battery modules
5. Connect the cable between the battery modules
6. Connect the cable to the inverter
Note: After the rack installation, the center distance of the cable terminals of parallel cables of
battery modules is 127mm.
The parallel cable of rack-mounted battery is as follows:

Amensolar Lithium Battery A5120 User Manual
11
B. Cabinet installation
1. Place the battery in the cabinet
2. Fixed the equipment with 4 screws
3. Connect the ground cable between the battery modules
4. Connect the communication cable between the battery modules
5. Connect the cable between the battery modules
6. Connect the cable to the inverter
6.4 Boot instructions
6.4.1 Turn on the power supply
Carefully check all the power cables and communication cables.
Turn on all battery modules and the green LED will come on:
6.4.2 Master and slave mode setting
address
Dip Switch Address
1#
2#
3#
4#
1
on
off
off
off
2
off
on
off
off
3
on
on
off
off
4
off
off
on
off
5
on
off
on
off
6
off
on
on
off
7
on
on
on
off
8
off
off
off
on
9
on
off
off
on
10
off
on
off
on
11
on
on
off
on
12
off
off
on
on
13
on
off
on
on
14
off
on
on
on
15
on
on
on
on
Note: Only the master battery module can communicate with the slave battery modules.
Master
Slave 1
Slave 2

Amensolar Lithium Battery A5120 User Manual
12
6.4.3 Connection in parallel mode
Normal parallel mode, as shown in the picture
Note: If all the battery LED lights come on and
then go off, this means that the battery system is
good and works properly.
7. Safety precautions
Warning
7.1 Notes required before installation
7.1.1 After opening the carton, please check the product and packing list first. If the product is
damaged or missing parts, please contact the local retailer;
7.1.2 Before installation, you must cut off the power supply, and ensure that the battery is turned
off;
7.1.3 The wiring must be correct, do not mistake the positive and negative electrode cable, and
ensure no short circuit with external equipment;
7.1.4 Direct connection between the battery and the AC current is prohibited;
7.1.5 The embedded BMS in the battery is designed for 48VDC, please do not connect the battery
in series;
7.1.6 The battery system must have a good grounding, and its resistance must be less than 1 Ω;
7.1.7 Please ensure that the electrical parameters of the battery system are compatible with the
relevant equipment;
7.1.8 Keep the battery away from the water and the fire.
7.2 Notes in the operation process
7.2.1 If the battery system needs to be moved or repaired, the power supply must be cut off and
the battery must be completely turned off;

Amensolar Lithium Battery A5120 User Manual
13
7.2.2 It is strictly prohibited to connect the battery with different types of batteries.
7.2.3 It is strictly prohibited to work the battery with the problematic or incompatible frequency
converter;
7.2.4 Never remove the battery (the QC label is removed or damaged);
7.2.5 In case of fire, only the dry powder fire extinguisher can be used, and the liquid fire
extinguisher is prohibited;
7.2.6 Do not open, repair or remove the battery except those authorized by the manufacturer or
distributor. We do not bear any consequences or related liabilities arising from the violation of
safe operation or the violation of design, production and equipment safety standards.
REMINDING
1) Please read the user manual carefully;
2) If the battery is stored for a long time, it needs to be charged once every six months, and the
SOC should not be less than 80%;
3) After the battery is fully discharged, it should be charged within 12 hours;
4) Do not expose the cable to the outside;
5) All battery terminals must be disconnected for maintenance;
6) If any abnormal, please contact the supplier within 24 hours.
7) The direct or indirect losses caused by the above items shall not be covered by the warranty.
8. Abnormal Conditions and Fault Handling
8.1 Troubleshooting steps
8.1.1 Check whether the battery can be turned on;
8.1.2 If the battery is on, check whether the red light is off, flashing or on;
8.1.3 If the red light is off, check if the battery can be charged / discharged.
8.2 Failure recognition
8.2.1 The battery cannot be turned on, and the lights are not on or flashing after the boot.
If the external power of the battery is on, the state light is flashing, the external power supply
voltage is above 48V, and the battery still cannot be turned on, please contact the supplier.
8.2.2 The battery can be turned on, but the red light is on and cannot be charged or discharged.
The red light is on, which means the system is not normal, check the following values:
Temperature: over 56℃ or below-20℃, the battery does not work.
Solution: Move the battery to the normal operating temperature range of-10℃ to 50℃.
Current: If the current is greater than 100A, the battery protection is turned on.
Solution: check whether the current is too large, if it is too large, to change the setting of the
power side.
High voltage: If the charging voltage exceeds 57.6V, the battery protection will be turned on.

Amensolar Lithium Battery A5120 User Manual
14
Solution: Check whether the voltage is too high, and if so, change the setting of the power supply
side.
Low voltage: When the battery discharges to 44.8V or lower, the battery protection is turned on.
Solution: Charge the battery for a while, and the red light will go out.
Excluding the above four points, if the fault still cannot be found, please turn off the battery and
repair it.
8.3 Charging troubleshooting
8.3.1 Unable to charge:
Disconnect the power cable and measure the voltage on the power side. If the voltage is 53~54V,
restart the battery, connect the power cable and try again. If still not, turn off the battery and contact
the dealer.
8.3.2 Failure to discharge:
Disconnect the power cable and measure the voltage on the battery side. If the voltage is lower than
48V, please charge the battery. If the voltage is above 48V, and still cannot discharge, please turn off
the battery and contact the dealer.
9. Emergency
9.1 Battery leakage
If the battery has leaked the electrolyte, avoid contact with the leaked liquid or gas. If exposed with
this substances, the following measures should be taken immediately:
Inhalation: evacuate the contaminated area and seek medical care.
Eye contact: rinse the eyes with running water for 15 minutes and seek medical care.
Contact with the skin: wash the affected area thoroughly with soap and water, and seek medical
treatment.
Intake: induced vomiting and seek medical assistance.
9.2 Fire
Don't use water! Only dry powder extinguishers; if possible, move the battery pack to a safe area
before catching fire.
9.3 Water
If the battery pack is wet or soaked in water, do not contact it, and then contact the manufacturer or
authorized dealer for technical support.
9.4 Battery damage
Damaged batteries are dangerous and must be dealt with in the most prudent manner. They are not
suitable for use and may pose a danger to persons or property. If the battery pack appears to be
damaged, pack it in the original container and return it to the manufacturer or authorized distributor.
Legal statement

Amensolar Lithium Battery A5120 User Manual
15
The copyright of the manual belongs to AMENSOLAR ESS CO., LTD.. Any unit,
company or individuals is not allowed to extract, copy and translate it in any way without the
written permission of copyright owner. Otherwise, infringement must be investigated.
The user manual doesn’t grant readers the permission and rights to use any marks showing
in the manual in any method without the prior written agreement of AMENSOLAR ESS CO.,
LTD. or owner of manufacturer’s trademark or trade name.
The product complies with the requirements of environmental protection and personal
safety. The storage, use and disposal of product should be carried out in accordance with the
product manual, relevant contracts or laws, regulations.
You can check relevant technical information through AMENSOLAR ESS website when
there are product updates and technical changes.
Amensolar ESS Co., Ltd.
Web: www.amensolar.com
Add: No. 900, Zhujiang Road, SND, Suzhou City, Jiangsu Province, PRC
Tel: 0086-512-68243965
This manual suits for next models
1
Table of contents
Other Amensolar Batteries Pack manuals
Popular Batteries Pack manuals by other brands

innonet
innonet P-LIGHT Magnum Installation and instructions for use

Intenso
Intenso WPD10000 user manual

Ryobi
Ryobi ONE+ RB18L30A Original instructions

Intel
Intel AXXRSBBU3 installation guide

Xtreme Power Conversion
Xtreme Power Conversion XPRT Series instruction manual

POWEROLOGY
POWEROLOGY PPBCHA04-PU quick start guide