1. Install the Main Unit
Introduction
A50 Carbon Dioxide Detector
Quick Start Guide
Analox Sensor Technology Ltd
15 Ellerbeck Court, Stokesley Business Park,
North Yorkshire, TS9 5PT, UK
T: +44 (0)1642 711400 F: +44 (0)1642 713900
W: www.analoxgroup.com E: [email protected]
Copyright © 2018 Analox Ltd. All Rights Reserved.
Scan the QR code to
visit the A50 Web page
Document ref: P0204-8010-01
This Quick Start Guide explains how to install the A50 Carbon Dioxide
Detector. For more information on operation and maintenance, refer
to the A50 Carbon Dioxide Detector User Manual P0204-8000. This is
available to download from www.analoxsensortechnology.com.
If tted, retain the clear protective lm on
the fascia until the installation is complete.
Using the drilling template mark out and
drill the wall-xing positions
ensuring the main unit is level. Then t the
wall plugs.
Secure the main unit to the wall using the
supplied No.6 self tapping screws.
2. Fitting the Repeater
If tted, retain the clear protective lm on the fascia until the installation is complete.
Using the drilling template, mark out and drill the wall-xing position then install the
wall plugs and t the unit.
Secure the repeater to the wall using the supplied No.6 self tapping screws.
The Remote Alarm Repeater
should be located at eye level
and attached to the outside or
immediately inside the access
door.
3. Connecting the Repeater - Hard Wired
1] Make sure the A50 is not powered
up.
2] Open the Remote Alarm Repeater
unit by removing the 4 screws in the
front of the case and carefully pulling
the case apart. The connecting wires
from the A50 pass through one of the
cable glands on the Remote Alarm
Repeater.
3] Terminate the wires in accordance
with the table.
4] Replace the lid of the Remote Alarm
Repeater and ret the 4 screws.
NOTE: IF YOU HAVE MORE THAN ONE ENTRANCE TO YOUR CELLAR OR STORE
ROOM YOU MAY NEED MORE THAN ONE REMOTE ALARM REPEATER. UP
TO THREE REPEATERS CAN BE DAISY CHAINED (ONE REPEATER LINKED TO
ANOTHER) COVERING UP TO THREE ENTRANCE DOORS.
NOTE: FOR OPTIMAL PERFORMANCE, IF THERE IS A LARGE VARIANCE BETWEEN
WHERE UNITS ARE STORED AND WHERE THEY ARE INSTALLED, IT IS
RECOMMENDED THAT UP TO 2 HOURS IS ALLOWED AFTER INSTALLATION
BEFORE APPLYING POWER. THIS IS TO ALLOW FOR TEMPERATURE
STABILIZATION IN THE UNIT WHICH IS IMPORTANT FOR DEVICE
ACCURACY.
NOTE: CARBON DIOXIDE GAS (CO2) IS HEAVIER THAN AIR AND SHOULD BE
MONITORED FROM A LOW HEIGHT. YOU SHOULD THEREFORE INSTALL
THE CO2 SENSOR AT A HEIGHT OF 12–18” (305–457MM) ABOVE THE
FLOOR LEVEL.
5. Powering Up
4. Connecting the Repeater - Quick Connect
1] Make sure the A50 is not powered up.
2] Insert the connector on the end of the wire into either socket on the bottom of
the Remote Alarm Repeater.
NOTE: IF YOU HAVE MORE THAN ONE ENTRANCE TO YOUR CELLAR OR STORE
ROOM YOU MAY NEED MORE THAN ONE REMOTE ALARM REPEATER. UP
TO THREE REPEATERS CAN BE DAISY CHAINED (ONE REPEATER LINKED TO
ANOTHER) COVERING UP TO THREE ENTRANCE DOORS.
Once the repeater(s) have been connected, simply plug the mains cable coming from
the main unit into an available socket and turn on, the A50 will perform a self test for
approximately 40 seconds.
During normal operation, the OK status indicator will ash on and o, thus indicating
that the system is operating correctly. The OK status indicator on any Remote Alarm
Repeaters will also ash on and o.
6. Lamp & Alarm Test
Momentarily pressing the Mode button on either the A50 or any Remote Alarm
Repeater, in the absence of any alarm conditions, causes a lamp and alarm test to be
performed. The status indicators will ash 4 times, together with the horn. This test
should be carried out each time the area is entered or at the start of each shift.
58
161
DRILL HOLES REQUIRE 4 x No. 6 SCREWS
( MARKED WITH CENTRE MARKS ).
DRILL DEPTH = 30mm
132
REV
NOTES
DCN
AUTHOR
CHECKED BY
APPD BY
APPVL REF
DATE
00
ORIGINAL ISSUE - DERIVED FROM A50-400-03
N/A
poliver
CG
N/A N/A
13/05/2015
01
UPDATED TEXT IN THE TITLE TO REFRENCE ADDITIONAL OUTPUT
MODULE
N/A
LR MS
N/A N/A
21/05/2018
B
C
D
1
2
A
3
2
1
4
B
A
5
6
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
TOLERANCES:
FINISH:
N/A
MATERIAL:
DO NOT SCALE DRAWING
REVISION
TITLE:
DWG NO.
A4
C
SUPPLEMENTARY TITLE:
3
The contents of this drawing are Copyright and are not to be disclosed
to a third party without written permission from Analox.
ANALOX LTD.
15 ELLERBECK COURT,
STOKESLEY,
NORTH YORKSHIRE.
TS9 5PT. UK
TEL: +44 1642 711400
www.analox.net
DOC. TYPE:
SHEET 1 OF 1
P0159-4110
01
Ax60+ CENTRAL DISPLAY,
SENSOR, ALARM & DATA
OUTPUT MODULE
DRILLING TEMPLATE
N/A
N/A
ISO 2768-fh
N/A
58
161
DRILL HOLES REQUIRE 4 x No. 6 SCREWS
( MARKED WITH CENTRE MARKS ).
DRILL DEPTH = 30mm
132
REV
NOTES
DCN
AUTHOR
CHECKED BY
APPD BY
APPVL REF
DATE
00
ORIGINAL ISSUE - DERIVED FROM A50-400-03
N/A
poliver
CG
N/A N/A
13/05/2015
01
UPDATED TEXT IN THE TITLE TO REFRENCE ADDITIONAL OUTPUT
MODULE
N/A
LR MS
N/A N/A
21/05/2018
B
C
D
1
2
A
3
2
1
4
B
A
5
6
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
TOLERANCES:
FINISH:
N/A
MATERIAL:
DO NOT SCALE DRAWING
REVISION
TITLE:
DWG NO.
A4
C
SUPPLEMENTARY TITLE:
3
The contents of this drawing are Copyright and are not to be disclosed
to a third party without written permission from Analox.
ANALOX LTD.
15 ELLERBECK COURT,
STOKESLEY,
NORTH YORKSHIRE.
TS9 5PT. UK
TEL: +44 1642 711400
www.analox.net
DOC. TYPE:
SHEET 1 OF 1
P0159-4110
01
Ax60+ CENTRAL DISPLAY,
SENSOR, ALARM & DATA
OUTPUT MODULE
DRILLING TEMPLATE
N/A
N/A
ISO 2768-fh
N/A
7. Technical Specications
8. Service and Support
If you require technical or service support please
visit: https://www.analoxgroup.com/support/sup-
port-faq
9. Disposal
WEEE statement
Analox will provide a disposal service if this is
benecial to the customer. Analox are registered
for the disposal of WEEE in the UK through the
Environment Agency (2013 Registration number
WEE/KE0043SY).
Carbon dioxide Range 0.1-5%
Response Time 60 Seconds to T90
Operating Temperature -5 to +40°C
Temperature Eect <0.1%FS/°C
Sensor Type -
Carbon dioxide
Analox infrared detector
Alarms 2 x Alarm status indicators
1 x Fault status indicator
1 x OK status indicator
Common Audible Alarm - Horn
Power 100 – 120 VAC, 50/60Hz, <5W or
100 – 250 VAC, 50/60Hz, <5W
Mains voltage supply uctuations not to exceed 10% of the
nominal voltage
Insulation
- Class II product
Double insulation or reinforced insulation
according to IEC 60417-5172 (2003-20)
Overvoltage CAT II
Pollution Pollution degree 2
Humidity Maximum relative humidity 80% for temperatures up to
31°C decreasing linearly to 50% relative humidity at 40°C.
Altitude <2000m
General - Indoor use
- Not for use in corrosive or explosive atmospheres**
- Not approved for use in vehicles, ships or aircraft
- The A50 conforms to DIN 6653-2:2015
** - Item only relates to CSA requirements (North America only)
If the equipment is used in a manner not specied by the manufacturer, the
protection provided by the equipment may be impaired.
Analox has a policy of continuous improvement and we reserve the right to
upgrade or change specications without prior notice.

Other manuals for A50

1

Other ANALOX Security Sensor manuals

ANALOX Ax60 User manual

ANALOX

ANALOX Ax60 User manual

ANALOX A50 User manual

ANALOX

ANALOX A50 User manual

ANALOX Ax60 User manual

ANALOX

ANALOX Ax60 User manual

ANALOX Ax60K User manual

ANALOX

ANALOX Ax60K User manual

Popular Security Sensor manuals by other brands

Elko Inels RFSF-18 manual

Elko

Elko Inels RFSF-18 manual

Winland Electronics ENVIROALERT EA200 quick start guide

Winland Electronics

Winland Electronics ENVIROALERT EA200 quick start guide

BEMKO SES07WH user manual

BEMKO

BEMKO SES07WH user manual

System Sensor B116LP Installation and maintenance instructions

System Sensor

System Sensor B116LP Installation and maintenance instructions

showhome ZW112 manual

showhome

showhome ZW112 manual

UE Systems Ultraprobe 3000 manual

UE Systems

UE Systems Ultraprobe 3000 manual

STEINEL PROFESSIONAL IS 345 MX PF manual

STEINEL PROFESSIONAL

STEINEL PROFESSIONAL IS 345 MX PF manual

D-Industrial Technology Q200 user manual

D-Industrial Technology

D-Industrial Technology Q200 user manual

Superior AccuTrak VPE user manual

Superior

Superior AccuTrak VPE user manual

Synergys LEAKSHOOTER LKS1000 V3+PRO user guide

Synergys

Synergys LEAKSHOOTER LKS1000 V3+PRO user guide

Promeba PS-183 user guide

Promeba

Promeba PS-183 user guide

Aritech Mini 6920P Installation sheet

Aritech

Aritech Mini 6920P Installation sheet

SPX Radiodetection RD8200 Operation manual

SPX

SPX Radiodetection RD8200 Operation manual

Berker 102 09 Operation and assembly instructions

Berker

Berker 102 09 Operation and assembly instructions

Satel COBALT user manual

Satel

Satel COBALT user manual

Orno OR-DB-YR-127 quick start guide

Orno

Orno OR-DB-YR-127 quick start guide

Geca Beta 760 CO manual

Geca

Geca Beta 760 CO manual

Endress+Hauser Nivotester FTL325N-**** Series operating instructions

Endress+Hauser

Endress+Hauser Nivotester FTL325N-**** Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.