1 IMPORTANT:READANDUNDERSTANDTHISMANUALBEFOREOPERATION
INTRODUCTION
2 FEATURES
CHARGINGDIONIC®HCBATTERIES
3-4 NOMINALCHARGETIMESFORDIONIC®HC
4-5 OPERATINGGUIDELINES
5 SERVICE
PRECAUTIONS
DIONIC®HCBATTERYSPECIFATIONS
6 WARRANTY-DIONIC®HCBATTERY
7 TRANSPORTATIONNOTICE
TABLE OF CONTENTS
Approved Copy

1
IMPORTANT:
READ AND UNDERSTAND THIS MANUAL BEFORE OPERATION
TheDionic®HCbatterylithiumionchemistrydeliversahigherpowertoweightratiothan
NiCd&NiMH.However,alllithiumionbatterieshavemoresensitivecharginganddischarg-
ingparametersandrequirelongerchargetimes(2-5hours).See charging section page 2
for more details.
The Dionic® HC battery is specically designed to be charged with current InterActive®
or InterActive chargers. Older model InterActive MP4D, Quad, Lifesaver Dual, ABC800
cannot charge these batteries.
Do not attempt to charge on non InterActive chargers or chargers not manufactured
by Anton/Bauer.
Special safety circuits in the DIONIC® HC battery will prevent charging on ANY char-
ger, which cannot properly address the battery communication.
ThisDIONIC®HCbattery,becauseofitslithiumionchemistry,isunlikeothervideobatter-
iesyoumayhaveused.Specialprecautionsandhandlinginstructionsarecontainedinthis
manualandshouldbestrictlyadheredtoforsafeandreliableoperation. Contact Anton/
Bauer Customer Support at (203) 925-4991 or support@antonbauer.com with any
questions regarding this product.
INTRODUCTION
ThedevelopmentofthisnewDIONIC®HCbatterysystemhasbeenmadepossible
throughtheincorporationofInterActivetechnologyoftheAnton/BauerDigitalsystem
withtheverylatestlithiumioncellformulations.EachDIONICHCbatteryfeaturesan
on-board“fuelcomputer”tomonitorenergyputintoandtakenoutofthebattery,as
wellascriticaloperatingcharacteristicsandconditions.Thisdataiscommunicatedto
theInterActivechargertooptimizesafeandreliableperformance.
Inaddition,remainingbatterycapacityinformationisavailabletotheoperatorby
meansofaRealTimeTMLCDoneachbatteryandintheviewnderofmostbroadcast
andprofessionalcamcorders.ThepatentedinterfacefromtheDigitalbatterytothe
cameraviewnderisfactorystandardequipmentonmostcamera/camcordermodels
fromallcameramanufacturers.
Anton/BauerInterActivechargersweredesignedinanticipationofnewcelltechnolo-
gies,sochargersintheeldrequireonlyasinglechipupdatetoeffectivelyaddress
thisnewbatterysystem,aswellasthestandardProPac®,HyTRON™,andTrimPac®
batteryproducts.ThisupwardanddownwardcompatibilityuniquelyallowsAnton/
Bauertointroducenewhighperformancecelltechnologies,suchastheDIONIC®HC,
safelyandseamlesslyintoexistingbatteryinventories.
ThenewDIONIC®HCbatterywillautomaticallyidentifyitselftotheInterActivecharger,
activatingthespecializedchargeroutinesnecessarytoeffectivelyutilizethisnew
technology.
!
Approved Copy

2
FEATURES
1. Microprocessor Fuel Computer - Accuratelymonitorsthe
energyinthebatterywithprogramsthattakeintoaccount
batteryage,selfdischarge,charge/dischargerate,operat-
ingconditionsandpreviouslyexperiencedcharge/discharge
cycles.TheDIONIC®HCbatteryconstantly“learns”its
precisestateofchargeandremainingcapacity.Thisdatais
automaticallytransmittedtoanInterActivecharger.
2. Integral RealTime™ ‘LCD’ – ThisnewandexclusiveAnton/
Bauerfeaturedisplaysboththeremainingruntimeandthe
percentageofremainingbatterycapacityatalltimes- si-
multaneously.Nospecialadaptersorsetupisrequired.(see
completeexplanationpage3)
3. Viewnder Fuel Gauge Display - Cameraswhichincludethe
Anton/BauerInterActiveviewnderfeatureconnectwiththe
DIONIC®HCbattery“FuelComputer”todisplayanaccurate
“FuelGauge”ofremainingbatterycapacityintheviewnder.
Referenceyourcamera/camcordersowner’smanualfor
propermenusettings.
4. Impac® Case design - Highimpactcaseconstruction
protectsthecellsfromimpactthatwoulddamageordestroy
conventionalbatteries.
5. Gold Mount® Interface - PatentedworldwidestandardGold
MountconnectoriscompatiblewithallAnton/Bauercamera
mountsandaccessories.
6. Individual Computer Testing – AswithallAnton/Bauer
batteries,eachandeveryDIONIC®HCbatteryisindividually
testedtoassureoptimumcapacity,voltageandoverallqual-
ity.Aserializedcomputerperformancegraphasconrmation
ofthistestingisenclosed.
CHARGING DIONIC HC BATTERIES
• DONOTATTEMPTTOCHARGETHISBATTERYWITHANYCHAR-
GEROTHERTHANTHEANTON/BAUERInterActiveORTSERIES
CHARGERSSPECIFIEDINTHISMANUAL.
• Allow the battery to reach a steady green (LifeSaver®) mode
before using for the rst time. Please read the individual charger
Owner’s Manual to become acquainted with the many unique
operating features of the chargers.
• TheDIONIC®HCbatterywillbeapproximately90%chargedwhenthe
LED’sonthechargerindicateFLASHINGGREEN.Thebatteryis100%
chargedwhenthechargerindicatesSTEADYGREEN.TheDionicHC
batterymayberemovedfromthechargeranddischargedineither
condition.
• The DIONIC® HC battery can remain on the charger until just prior
to being used. TheLifeSaver(STEADYGREENchargerLEDindica-
tion)maintenanceroutinekeepsthebatterychargedandreadyfor
use.Ifthebatterywillnotbeusedforanextendedperiod(morethan
60days)see“OperatingGuidelines”onpage4.
ForbestresultsthisbatteryshouldbeusedorreturnedtotheInterAc-
tiveorTSerieschargerwithin48hoursofbeingused.
Note:Onsomeolderchargersitmaybenecessarytoinstallbatteryon
charger,waitone(1)minute,thenremovebatteryandre-install.This
proceduremayneedtoberepeatedmorethanonceto“wakeup”alow
voltagebattery.
NOMINAL CHARGE TIMES FOR DIONIC® HC
Charge Level LED Indicators 90%
Flashing
Green
100%
Steady
Green
Dual 2722 (2 batteries simultaneously) 2hrs. 3hrs.
InterActive PowerCharger
(Quad/Dual – 2702/2701/2700)
(Quad/Dual – 2401/2400)
(2 or 4 batteries sequentially)
2 hrs. 3 hrs.
T2 (2 batteries simultaneously) 2hrs. 3hrs.
Tandem® 70 2hrs. 3hrs.
TWIN (2 batteries simultaneously) 4hrs. 5hrs.
TWQ (4 batteries simultaneously) 4hrs. 5hrs.
TM-4 (4 batteries simultaneously) 2hrs. 3hrs.
Chargetimecanvarydependingonage,conditionandremainingcapacityofeach
batteryatthetimeitisplacedonthecharger.
CHARGING TIMES
Approved Copy

3
BATTERY AND DISPLAY
TheRealTimeTMLCDprovideson-the-yremainingruntimeestimates
in15minuteincrementsaswellasprovidingremainingcapacityinfor-
mationusingthetraditional“gasgauge”approach.Inthisway,the
LCDprovidestwodifferentmethodsofdeterminingbatterycapacity.
Thefollowingisadescriptionofthefeaturesoftheremainingruntime
LCD:
1. Theremainingruntimeiscalculatedusingthepresentavailable
capacityandameasureofthepresentpowerload.
2. Ifnoloadhasbeendetected,orifthebatteryiscomingoffachar-
ger,thedefaultassumedpowerforremainingruntimecalculations
is20watts.
3. Whenthebatterydeterminesthataloadisattached,thedefault
20wattloadwillbeabandonedandanewremainingruntimewill
becalculatedbasedonthenewloadpresentedtothebattery.
4. Thebatterywill“learn”thisnewloadandretainthatloadinforma-
tioninnon-volatilememory.
5. Ifthebatteryisremovedfromaloadandplacedonashelffor
extendedperiods,theremainingruntimecalculationwillcontinue
tousethelearnedloadvalueforupto30minutes.
6. After30minutes,theremainingruntimecalculationwillagainuse
thedefault20wattloadasacriteria.
TheDIONIC®HCfeaturesanallNEW“RealTimeTM”LCDprovidingon-the-yremainingruntimeestimatesin15minuteincrementsaswellas
simultaneouslyprovidingremainingcapacityinformationusingthetraditional“FuelGauge”approach.Nospecialadaptersorsetupisrequired.
RealTime™automatically calculates the load and displays capacity information and battery status at all times.
SpecialelectronicsprotectthelithiumioncellsintheDIONIC®HCbatteryfromdamageandtoensuresafeoperation.Theseelectronicsworkin
conjunctionwiththeDigitalBatteryelectronicsandwillgivetheoperatoradditionalindicationsintheRealTime™displayofthebattery’sstatus
asoutlinedbelow.
7.Whenthebatteryreacheditslearnedcapacityvoltagelevel(12.7
Vdc),theLCDwillbeginashingthe15minuteiconuntilthebat-
teryisreturnedtoacharger.
8. IfthebatteryreachesanEODcondition(12.4Vdc),theLCD’slast
fuelgaugesegmentwillbetheonlyremainingiconashinguntil
thebatteryisreturnedtoacharger.
9. IfthebatteryvoltagedropsbelowtheFuelGaugecutoutcircuit
voltage(10.0-10.8Vdc)theFuelGaugewillbedisabledandthe
LCDwillgoblankuntilthebatteryisreturnedtoacharger.
I. ANALOG FUEL GUAGE
LCD Segments % Capacity
1st Bar, 2nd Bar, 3rd Bar, 4th Bar, 5th Bar 100
2nd Bar, 3rd Bar, 4th Bar, 5th Bar 80
3rd Bar, 4th Bar, 5th Bar 60
4th Bar, 5th Bar 40
5th Bar 20
5th Bar ashing EOD (12.4 Vdc)
Digital readout
in Hours and
Minutes
Analog readout like a
“gas gauge”
15 minute arc
60 minute arc
Number of hours
45 minute arc
30 minute arc
Analog fuel gauge
5
th
bar
1
st
bar
Approved Copy

4
BATTERY AND DISPLAY (continued)
OPERATING GUIDELINES
II. REMAINING RUN-TIME GAUGE
LCD Segments Remaining Run Time
“3” & 4 arcs 4 Hours or greater
“3” & 4 arcs 3 Hours 45 minutes to 3 Hours 59 minutes
“3” & 3 arcs 3 Hours 30 minutes to 3 Hours 44 minutes
“3” & 2 arcs 3 Hours 15 minutes to 3 Hours 29 minutes
“3” & 1 arc 3 hours to 3 Hours 14 minutes
“2” & 4 arcs 2 Hours 45 minutes to 2 Hours 59 minutes
“2” & 3 arcs 2 Hours 30 minutes to 2 Hours 44 minutes
“2” & 2 arcs 2 Hours 15 minutes to 2 Hours 29 minutes
“2” & 1 arc 2 Hours to 2 Hours 14 minutes
“1” & 4 arcs 1 hour 45 minutes to 1 Hour 59 minutes
“1” & 3 arcs 1 Hour 30 minutes to 1 Hour 44 minutes
“1” & 2 arcs 1 Hour 15 minutes to 1 Hour 29 minutes
“1” & 1 arc 1 Hour to 1 Hour 14 mintues
4 arcs 45 minutes to 59 minutes
3 arcs 30 minutes to 44 minutes
2 arcs 15 minutes to 29 minutes
1 arc 14 minutes or less
1 ashing arc Learned Capacity Level Reached (12.7 Vdc)
1. Keep batteries cool or at room temperatures whenever pos-
sible.Sustainedelevatedtemperaturesaretheprimaryreason
forprematurefailureofbatteries:
a. Charging-Chargebatteriesatroomtemperature.Inwarm
climateskeepchargersinairconditionedroomsforbest
performance.
b. Onassignment-Donotleavebatteriesinahotvehicletrunk
oroutindirectsunlight.
c. Althoughlithiumionhasgoodself-dischargecharacteristics,
longtermstorageinafullychargedconditionwillresultin
irreversiblecapacityloss.Thisisaproblemforalllithium
ionbatteries–fromcellphonestovideocameras.Usethe
battery;donotstoreitforextendedperiods.
d. Batteriesshouldalwaysbestoredinapartiallychargedstate
andkeptcool.Ifbatteriesmustbestoredforalongperiod
(oversixmonths),theyshouldbeperiodicallyremovedfrom
storageandsubmittedtoadischarge/chargecycle.
2. Do not over-discharge batteries -Itisquitepropertodischarge
abatteryuntilalowvoltagewarninginthecameraorVTRis
observed.However,aswitchtoafreshbatteryshouldoccuras
soonaspossiblefollowingsuchindication.Neverleaveabattery
operateddeviceunattendedwhileitisrunning.
3. DO NOT LEAVE A BATTERY ATTACHED TO A CAMERA/CAM-
CORDER during transit or storage.“Keepwarm”circuitryin
thecameracandrainthebattery,becausetheDIONICHCbattery
hasspecializedcircuitswhichwillnotallowabatterytooverdis-
charge,thebatterywillprotectitselfandshutdown.
4. Lowvoltagebatteriescanalsobecausedbyallowingbatteries
toremainoffthechargerforextendedperiodscausingtheLCD
displaytobeblank,indicatingthattheelectroniccircuitryhas
removedallloadfromthebatterycells–includingthedisplay.In
thecasethatthebatteryisinalowvoltageconditionthebattery
shouldbereturnedtothecharger.Thechargeroutinewillnotbe
initiatedbythechargeruntilallotherbatterieshavecompleted
theirfastchargeroutines.Therefore,alowvoltagebatterycanbe
installedonanInterActivechargerwithoutthechargerindicat-
ingrecognition.Thebatteryshouldremainonthechargeruntil
chargingiscomplete.Itmaybehelpfultoremoveotherbatteries
beforeplacingabatterywithablankdisplayonthecharger.Ifthe
batterydisplaygoesfromblanktoashing,removefromchar-
gerandreinstall.Ifashingdisplayconditionremains,contact
customersupport.
5. Neverleaveanybatteryunattendedonequipment.
6. Routineuseofabatteryatdischargeratesgreaterthanthebat-
teryrating(e.g.150wattsmaximum,75wattsorlessforlighting
load)canreduceoverallservicelife.Alwaysselecttheproper
sizebatteryforyourapplication.
7. Dischargingthebatteryfordiagnosticpurposesshouldonly
beperformedonanoccasionalbasis(onceevery6-8weeksat
most).Unnecessarydischargingonlydetractsfromoveralllife.
Approved Copy

5
8. Periodiccleaningofboththechargerterminalsandbatterytermi-
nalswillensurecontinuedreliableoperation.Cleantheterminals
occasionallywithapencileraserorlightlyscrapethesurfacewith
abluntinstrumenttohelpreducethispossibility.
Anton/Bauerpublishesacomprehensive“VideoBatteryHandbook”
tohelpyoufurtherunderstandthecareanduseofvideobatteries.
ThisguideisavailableatnochargebycontactingAnton/Bauerat
1-800-422-3473or203-929-1100orfax203-929-9935.Itcanalso
bedownloadedfromthewebatwww.antonbauer.com.
CIRCUMSTANCES attempt to “recondition” this battery by
repeated charging and discharging.
4. This battery contains specialized electronic circuits, which
are designed to protect the lithium ion cells from over-
charge, overdischarge and overcurrent. Redundant protec-
tion devices are designed to operate if the battery voltage is
abnormally high or low and if the temperature of the battery
exceeds operating specications. These electronic devices
can be damaged if the battery is subject to abuse or damage.
Do not use a battery that has been subjected to excessive
mechanical shock or water damage.
5. Do not drop, puncture or crush this battery. Do not use the
battery if the case is damaged or broken. Do not open or at-
tempt to service this battery if damaged.
BATTERY SPECIFICATIONS
OUTPUT VOLTAGE 14.4v Nominal
12.4 ~ 16.8v Operating
CAPACITY 91 WH Typical
FUSE Internal 10amp
RECOMMENDED OPERATION 50-100 watts
(MAXIMUM DISCHARGE RATE) (150 watts)1
TYPICAL RUN-TIME
@ 20w - 4 ½ hrs.
@ 25w - 3 ½ hrs.
@ 40w - 2 ¼ hrs.
WEIGHT 1.75 lbs
SIZE 5.46 x 4.06 x 2.34
CHARGE TEMPERATURE 0 – 40°C
DISCHARGE TEMPERATURE -20 – 60°C
STORAGE TEMPERATURE -20 – 50°C
1 Routine use of a battery at discharge rates greater than the recommended operating range can reduce overall service
life. Always select the proper size battery for your application.
SERVICE
IntheeventaDIONIC®HCbatteryfailstodeliveracceptableper-
formance,itmustbereturnedtotheAnton/Bauer.Nootherfacility
isqualiedandequippedtoservicetheDIONICHCbatteriesand
calibratetheelectroniccomponentsandsensors.Anyattemptby
theuseroranyotherunauthorizedpersonstoservicethisbattery
willsurelyresultinimpropercalibrationoftheelectroniccomponents
resulting in severe battery damage and/or safety hazards,includ-
ingpotentialpersonalinjuryand/ordamagetoproperty.Anysuch
attemptwillvoidany/allwarranties.
WARNING
1. NEVERattempttoservicethisbattery.Ifthereisaproblem,send
thisbatteryonlytoAnton/Bauerforevaluation.
2. NEVER ATTEMPT TO OPEN THIS BATTERY.Theelectronic
circuitsinsidethebatterycanbedamagedcausingmalfunction
and/orpotentialhazardtopersonandproperty.
3. NEVERattempttoreplacethecellsinthisbattery–itcannotbe
rebuiltorserviced.AttheendofitsusefullifecontacttheAnton/
BauerCustomerSupportGroupatsupport@antonbauer.comor
(800)541-1667.
PRECAUTIONS
1. Do not expose this battery to high temperatures (above
50°C/120°F). This includes storage in direct sunlight , in cars
in hot weather, or in close proximity to heating devices. This
may cause electrolyte leakage, impaired performance and
shortening of battery service life.
2. When not using the battery for prolonged periods, the DIONIC
HC battery should be charged.
3. ALL LITHIUM ION BATTERIES have a nite life. If the battery
exhibits noticeably shortened run time the battery should
be replaced immediately. Shortened runtime is indicative of
at least one cell which has reached end of life. UNDER NO
Approved Copy

6
Thiswarrantyforthebatteryproductspeciedinthisdocument
(“Product”)isgivenbyAnton/Bauer,Inc.(“Anton/Bauer”),14Prog-
ressDrive,Shelton,Connecticut06484.Ifyou(thepurchaserofthe
ProductfromAnton/Bauer,orthepersonforwhomtheProductwas
purchased,ifitwasagift)haveanyquestionsregardingProductap-
plications,Productspecication,ortoobtainwarrantyserviceonthis
oranyAnton/Bauerproduct,contactthecompanyattheaddress
above.
THISPRODUCTMUSTBEREGISTEREDWITHANTON/BAUERWITHIN
30DAYSOFPURCHASETOASSUREWARRANTYCOVERAGE.TO
REGISTERYOUMAYEITHER:
(1)MAILWARRANTYREGISTRATIONCARDor
(2)REGISTERONLINEATwww.antonbauer.com
Warrantyregistration,includingtheserialnumbersofAnton/Bauer
chargersusedwiththisbattery,mustbesuppliedtoAnton/Bauer.
Anton/BauerwillwarrantytheProductonlyagainstdefectsinmate-
rialandworkmanshipfortheperiodasfollowsfromthedateof
purchase,inaccordancewiththetermssetforthbelow,andthen,
onlyiftheProductisusedexclusivelyinconjunctionwithcompatible
Anton/Bauerchargers.IfthisbatteryisreturnedtoAnton/Bauerfor
warrantyserviceitwillberequiredthatyouprovidemodelnamesand
serialnumbersofcompatibleAnton/Bauerchargerswithwhichthis
productwasused.
Dionic®HC:
ThiswarrantyshallbeeffectiveonlyifAnton/Bauerreceivesnotice
ofsuchdefectsinmaterialsorworkmanshipduringtheperiodofthe
warranty.Minimumbatterycapacityisdenedunderthiswarranty
as60%ofnominalspeciedcapacityforthisProductattimeof
purchase.
TheliabilityofAnton/Bauerhereunderisexpresslylimitedtoaclaim
forrepairorreplacementoftheProductorasotherwisestatedherein
atAnton/Bauer’ssolediscretion.Noticeofanyclaimunderthiswar-
rantyshallbedeliveredtoAnton/Bauerduringtheperiodofthewar-
rantyandtheProductshallbereturnedwithitspackagingpromptly,
atyourexpense,toanAnton/BauerCustomerSupportCenterorto
theaddressabove.UponreceiptoftheProductandarecordofyour
compliancewiththeconditionsofthiswarranty,Anton/Bauerwill
repairorreplacetheProductandreturnittoyou,orissueacredit,as
applicable.Youareresponsibleforallshippingandhandlingcharges
toandfromauthorizedfacility.
THISWARRANTYDOESNOTAPPLYTOANDISVOIDINTHECASE
OFDEFECTSORDAMAGERESULTINGFROMACCIDENTS,DISAS-
TER,NEGLECT,MISUSE,IMPROPERINSTALLATION,IMPROPER
ORUNAUTHORIZEDSERVICEORMAINTENANCE,UNAUTHOR-
IZEDREPLACEMENTPARTSORATTACHMENTS;ORDYSFUNC-
TIONORMALFUNCTIONOF,ORCAUSEDBY,ANYOTHERPROD-
UCTORDEVICE.Misuse includes any use of the Product in other
than its intended application, including the use of this Product
with any charging device or accessory not manufactured by and/
or specied by Anton/Bauer. This warranty does not cover, and
Anton/Bauer assumes no responsibility for, any equipment or
devices used in conjunction with the Product.
ANTON/BAUERDISCLAIMSANYLIABILITYFORINCIDENTALOR
CONSEQUENTIALDAMAGESFORBREACHOFANYWRITTEN
ORIMPLIEDWARRANTYOFTHEPRODUCT.UNDERNOCIR-
CUMSTANCESWILLANTON/BAUERBERESPONSIBLEFORANY
SPECIAL,INCIDENTALORCONSEQUENTIALDAMAGES.
ThisWarrantyistobeconstruedandenforcedinaccordancewith
thelawoftheStateofConnecticut,includingtheprovisionsofthe
UniformCommercialCodeasadoptedandfromtimetotimeamend-
edintheStateofConnecticut,andnottheConventionfortheInter-
nationalSaleofGoods.ThischoiceofConnecticutlawisexclusive
ofanyConnecticutlawthatwouldrequirerelianceonanylawforeign
toConnecticut.Shouldanyactionoflaworinequitybebroughtby
anypersonunderthisWarranty,suchactionshallbebroughtonly
intheUnitedStatesDistrictCourtfortheDistrictofConnecticut,or
inanySuperiorCourtinFaireldCounty,Connecticut,USA.Some
statesdonotallowlimitationsonhowlongawarrantylasts,sothe
timeperiodlimitationhereinmaynotapplytoyou.Somestatesdo
notallowtheexclusionorlimitationofincidentalorconsequential
damages,sotheabovelimitationorexclusionmaynotapplytoyou.
Thiswarrantygivesyouspeciclegalrightsandyoumayhaveother
legalrightswhichmayvaryfromstatetostate.
UseofunauthorizedequipmentinconjunctionwithAnton/Bauer
productsconstitutesmisuseunderourwarrantiesandmaylimitor
voidthosewarranties.Anton/Bauerdoesnotauthorize,condone,
recommend,orotherwiseassumeanyliabilityorresponsibilityresult-
ingfromtheuseofanybattery,charger,oraccessorymadebyAn-
ton/Bauerwithanybattery,chargeroraccessorynotmanufactured,
producedorsoldbyAnton/Bauer.Anton/Baueronlyauthorizesthe
useoforiginalAnton/BauerproductswiththisProduct.Useonly
originalAnton/BauerequipmentwiththisProduct.
LIMITED WARRANTY
0-18MONTHS:Anton/Bauerwillrepairorreplacethe
ProductatAnton/Bauer’soptionandcost.
“Purchaseprice”and“purchasedate”asreferenced
istheunitpricepaidbyandthedateofsuchsaleby
theoriginalcustomerfromanyauthorizedAnton/Bauer
dealerordistributoranddoesnotincludeanytax,ship-
ping,VAT,duty,feesorhandlingcharges.Customer
mustprovideproofofpurchaseormanufacturer’slist
pricewillbeused.
Approved Copy

7
AIR TRANSPORTATION REGULATION
DOTDangerousGoodsRegulations49CFRParts100-185,InternationalAirTransportAssociation(IATA)andtheInternationalCivilAviation
Organization(ICAO)rulesapplytoalllithiumionbatterytransport.
AIR TRANSPORTATION DECLARATION
Anton/Bauer, Inc. declares that the Dionic HC lithium ion battery pack is rated 91 Wh and contains equiva-
lent lithium content (ELC) in a quantity not exceeding 8 grams.
This quantity is compliance with IATA/IACO Dangerous Goods regulations Packing Instruction 965 (Special
packaging required.) and DOT Dangerous Goods Regulations 49CFR Parts 100-185.
The Dionic® HC battery pack is therefore excepted by denition and suitable for air transport as a non-
hazardous article.
PleasereferDOTDangerousGoodsRegulations49CFRParts100-185,InternationalAirTransportAssociation
(IATA)andtheInternationalCivilAviationOrganization(ICAO)rulingforthespecicshippinginstructions.
Approved Copy

Anton/Bauer
A Vitec Group brand
The following are trademarks of Anton/Bauer, Inc.:
Anton/Bauer, Anton/Bauer logo and parallelogram design, Aspekt, Automatique,
DataTap, DIONIC, Elipz, Egripz, Elightz, Essentialz, Gold Mount, HubZ, HyTRON, Impac,
Interactive and design, LifeSaver, Logic Series, Logic Series Logo, Maxx man logo design,
Nexus, PowerStrap, Proformer, Probe, ProPac, RealTime, Satellight, Snap-On, Stasis, Stasis
Flex, Tandem, TrimPac, Ultrakit, Ultralight, “One World. One Smart Choice”, “The power
behind the best cameras capturing the best images in the world.”, “The quality standard
of the video industry”, “The worldwide standard”, and “There should always be choices. It
makes it easier to recognize the best.”
Lexan is a registered trademark of G.E. Company Corp.
Cordura is a registered trademark of E.I. duPont de Nemours
Anton/Bauer, Inc.
World Headquarters
14 Progress Drive, Shelton, CT U.S.A.
Tel (203) 929-1100 or (800) 541-1667
Fax (203) 929-9935
support@antonbauer.com
Anton/Bauer Europe, B.V.
Eurode Business Center, Eurode - Park 1-2
6461KB Kerkrade, The Netherlands
Tel (+31) 45 5639220
Fax (+31) 45 5639222
eurosupport@antonbauer.com
www.antonbauer.com
Anton/Bauer, Inc. - Signapore Oce
6 New Industrial Road, # 02-02 Hoe
Huat Ind. Bld., Singapore 536199
Tel (+65) 62975784
Fax (+65) 62825235
asia@antonbauer.com
Approved Copy
Other manuals for Interactive 2000 PowerCharger
26
Table of contents
Other Anton/Bauer Batteries Pack manuals

Anton/Bauer
Anton/Bauer Interactive 2000 PowerCharger User manual

Anton/Bauer
Anton/Bauer Interactive 2000 PowerCharger User manual

Anton/Bauer
Anton/Bauer Interactive 2000 PowerCharger User manual

Anton/Bauer
Anton/Bauer Interactive 2000 PowerCharger User manual

Anton/Bauer
Anton/Bauer QR-DSR User manual

Anton/Bauer
Anton/Bauer Hytron 140 User manual

Anton/Bauer
Anton/Bauer Interactive 2000 PowerCharger User manual

Anton/Bauer
Anton/Bauer Interactive 2000 PowerCharger User manual

Anton/Bauer
Anton/Bauer Interactive 2000 PowerCharger User manual

Anton/Bauer
Anton/Bauer Interactive 2000 PowerCharger User manual