Aplex ARCDIS-1 (P/G) Series User manual

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
0
ARCDIS-1XX(P/G)(H)
(TB-6028)
7”, 8”, and 10.1”front panel IP66/IP69K(option)
aluminum die-casting chassis Display
User Manual
Release Date Revision
Jan. 2019 V1.6
®2019 Aplex Technology, Inc. All Rights Reserved. Published in Taiwan
Aplex Technology, Inc.
15F-1, No.186, Jian Yi Road, Zhonghe District, New Taipei City 235, Taiwan
Tel: 886-2-82262881 Fax: 886-2-82262883 URL: http://www.aplextec.com/zh/home.php

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
1
Revision History
Reversion
Date
Description
1.0
2014/10/03
Official Version
1.1
2015/06/10
Add 15.6”, 17”, and 18.5”
1.2
2015/07/29
Delete description of die-casting,
Modify Power Consumption
1.3
2017/04/18
Remove 15.6”,17”,18.5”,21.5”
Modify figure of Dimensions
and Product images
Modify Specifications:
Add High Brightness
External I/O Port
Construction of Mechanical
Enviroment Temperature
1.4
2017/07/25
Modify IP65 to IP66/IP69K
1.5
2017/10/23
Modify IP69K for option
Remove RCA function
Modify DVI to DVI-D
Add AR glass non-touch
Add Auto dimming images
1.6
2019/01/09
Add G model series information

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
2
Warning!___________________________
This equipment generates, uses and can radiate radio frequency energy and if
not installed and used in accordance with the instructions manual, it may
cause interference to radio communications. It has been tested and found to
comply with the limits for a Class A computing device pursuant to FCC Rules,
which are designed to provide reasonable protection against such interference
when operated in a commercial environment. Operation of this equipment in
a residential area is likely to cause interference in which case the user at his
own expense will be required to take whatever measures may be required to
correct the interference.
Disclaimer
This information in this document is subject to change without notice. In no event
shall Aplex Technology Inc. be liable for damages of any kind, whether incidental or
consequential, arising from either the use or misuse of information in this
document or in any related materials.
Electric Shock Hazard –Do not operate the machine with its back cover
removed. There are dangerous high voltages inside.

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
3
Table of Contents
Revision History………………………………………………………………………………….1
Warning!………………………………………………………………………………….……..….2
Disclaimer……………………….……………………………………………….…………………2
Chapter 1 Getting Started
1.1 Features…………………………………………………..…………………………….5
1.2 Specifications…………………………………………………………………………5
1.3 Dimensions……………………...……………...…..…………………………….…7
1.4 System Diagram(Full Function)................................................8
1.5 Brief Description of ARCDIS-1XX(P)(H)…….………..………………….9
1.6 Display Mode…………………………………………..…………………………..10
Chapter 2 OSD
2.1 AD Board OSD Functions………….…...………..….…..……………….….11
2.2 OSD Controls……………………………..…………….…………………….……12
2.3 OSD Functions…………………………………………..………………………...13
2.4 Main Menu………………………………..…………….……………………......13
Chapter 3 Installation
3.1 Windows 7 Universal Driver Installation for PenMount 6000
Series……………………….………..………………..………………………...…19
3.2 Software Functions…………………………………………………………….27
Appendix A: Board Descriptions & Specifications 45
Descriptions…………………………………….………………………………………...45
Specifications…………………………..…………….………………………………....45
Board Dimensions………………….…………………….……………………………46
Appendix B: Panel Mounting and VESA Mounting 47

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
4
Figures
Figure 1.1: Dimensions of ARCDIS-107(P/G)(H)….…….…………..…..7
Figure 1.2: Dimensions of ARCDIS-108(P/G)(H)…..………………………7
Figure 1.3: Dimensions of ARCDIS-110(P/G)(H)….……………………...8
Figure 1.4: System Diagram of TB-6028……………………………………...8
Figure 1.5: Front View of ARCDIS-1xx(P/G)(H)….…….………………...9
Figure 1.6: Rear View of ARCDIS-1xx(P/G)(H)……….…………………..9
Figure A: Dimensions of TB-6028……………………………………………..46
Figure B: Panel mounting and VESA mounting………………………….47

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
5
Chapter 1 Getting Started
1.1 Features
Solid Aluminum chassis
Variety of LCD panel size selections
IP66 / IP69K(option) compliant front bezel
VGA and DVI-D input
Wide range DC 9~36V power input
Auto dimming for option ( not available for 7”display)
Support protective AR glass for option (non-touch version)
1.2 Specifications
ARCDIS-107
(P/G)
ARCDIS-107
(P/G)H
ARCDIS-108
(P/G)
ARCDIS-108
(P/G)H
ARCDIS-110
(P/G)
ARCDIS-110
(P/G)H
Hardware
Display Type
7” color TFT LCD
8”color TFT LCD
10.1”color TFT LCD
External I/O Port
Default I/O:
1 x 3 pins terminal block for DC 9~36V power input
1 x DVI-D
1 x VGA
1 x USB type A for Touch control
Option I/O:
1 x line in by phone jack
1 x RS-232 DB-9 for Touch control
LED Light
1 x system power LED light
OSD Control
On board controller, extendable key pad from connector
Transfer Board OSD Membrane Keypad
Speaker
1 x 2W speaker for option
LCD
Max. Resolution
800x480
800x600
1280x800
Max. Color
262K
262K
16.2M
16.2M
16.7M
16.2M
Luminance(cd/m²)
350
1000
350
1000
350
1000
Contrast Ratio
400 : 1
400 : 1
500 : 1
500 : 1
800 : 1
1000:1
Viewing Angle
(H/V)
140(H)/130(V)
140(H)/125(V)
170(H)/170(V)
Backlight Lifetime
40,000 hrs
50,000 hrs(H)
40,000 hrs
30,000 hrs(H)
25,000 hrs
50,000 hrs(H)

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
6
Power Input
DC 9~36V on board
Power
Consumption
MAX: 4.2W
MAX: 4.1W(P)
MAX:4.7W
MAX:3.6W(P)
MAX:6.2W
MAX:5.9W(P)
Touch Screen ARCDIS-1XX (H)
Type
Resistive Touch Window
Interface
Default USB / RS-232 for option
Light Transmission
Over 80%
Touch Screen ARCDIS-1XXP(H)
Type
Projected Capacitive
Interface
USB
Light Transmission
Over 90%
Touch Screen ARCDIS-1XXG(H)
Type
Glass-AR
Interface
NA(Glass)
Light Transmission
Over 93%
Mechanical
Construction
Aluminum die-casting chassis
Dimensions
202x149x40 mm
231.1x176.1x50 mm
285x189x48.9 mm
Net Weight
1 kg
1.8 kg
1.7 kg
Mounting
Panel mount / VESA 75x75
Panel mount / VESA 100x100
Environment Specifications
Operating
Temperature
0 ~ 50 ℃
20 ~ 60 ℃for option
Storage
Temperature
-30 ~ 70 ℃
Storage Humidity
10 ~ 90% @40℃Non-condensing, without touch screen
IP Rating
Front Panel IP66 / IP69K(option)
Certificate
CE/FCC Class A

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
9
1.5 Brief Description of ARCDIS-1XX (P/G)(H)
ARCDIS-1XX(P/G)(H) series with TB-6028 AD Board is an IP66 / IP69K(option)
compliant front panel designed aluminum die-casting chassis LCD display, which
comes with 7, 8, and 10.1 inch color TFT LCD. It can be panel mounted in front bezel
and VESA 75 x 75 or VESA 100 x 100 mounted in rear bezel. There are multiple
external I/O ports come with VGA, DVI-D, USB, and RS-232…etc. The power supports
wide range DC 9~36V power input. Furthermore, High brightness 1,000 nits LCD is
ideal for sunlight readable semi-outdoors applications, and LCD can be optical
bonding designed for option. ARCDIS-1XX (P/G)(H)series model has more outstanding
features, thus giving the best in monitoring and control application.
Figure 1.5: Front View of ARCDIS-1xx (P/G) (H)
Figure 1.6: Rear View of ARCDIS-1xx (P/G) (H)

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
10
1.6 Display Mode
Item
Resolution
H Freq.(kHz)
V Freq.(Hz)
Remark
1
640x350@70
31.469
70.087
VGA
2
640x400@70
31.469
70.087
VGA
3*
640x480@60
31.469
59.940
VESA
4
640x480@66
35.000
66.667
MAC
5
640x480@72
37.861
72.809
VESA
6*
640x480@75
37.500
75.000
VESA
7
720x400@70
31.469
75.000
TEXT
8
800x600@56
35.156
56.250
VESA
9*
800x600@60
37.879
60.317
VESA
10
800x600@72
48.077
72.188
VESA
11*
800x600@75
46.875
75.000
VESA
12
832x624@75
49.107
75.087
MAC
13
848x480@60
31.020
60.000
VESA
14*
1024x768@60
48.363
60.004
VESA
15*
1024x768@75
60.023
75.029
VESA
17
1152x864@70
63.850
70.000
VESA
18
1152x864@75
67.500
75.000
VESA
19
1152x900@76
71.809
76.149
SUN
20*
1280x768@60
47.730
60.000
VESA
21*
1280x768@75
60.290
74.890
VESA
22
1280x960@60
60.000
60.000
VESA
23*
1280x1024@60
63.980
60.000
VESA
24*
1280x1024@75
79.976
75.025
VESA
25*
1366x768@60
47.710
60.020
VESA
26
1440x900@60
56.040
60.000
VESA
27
1440x1050@60
65.320
59.980
VESA
28
1440x1050@75
82.280
74.870
VESA
29*
1920x1080@60
67.500
60.000
VESA

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
11
Chapter 2 OSD
2.1 AD Board OSD Functions
Auto Adjust Up/Left Down/Right Power
Menu/Entry Power Indicator
Power switch: To turn ON or OFF the power
Shift the icon to the right side or shift it up
Shift the icon to the left side or shift it down
Menu: To enter OSD menu for related icon and item.
Auto Button: One-touch auto adjustment
1.) Getting into Burn-in Mode
Before setting into a burn-in mode, first disconnect the AC power cord. Then press
(don’t let them go) the buttons until the AC power cord is connected and the
“RGB” appears on the top left corner of your screen. Now it can be put into the
burn-in mode for changing colors.
2.) Getting Out of Burn-in Mode
Before getting out of the burn-in mode, please first disconnect the AC power cord.
Then press the button (If not workable, press the button and don’t let
them go) until the AC power cord is connected. Please don’t let your fingers go until
the AC power cord is connected again and the wording of “RGB” appears on the top
left corner of your screen, and wait for 3 second. Under the non-signal entry
situation, if is seen, exit is thus successfully made.
Cable Not Connected

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
12
When the Burn-in Mode is Unable to Eradicate…
1.) If the “RGB” is still on the top left corner of the screen, press to enter
“Miscellaneous” and choose “Reset”, and then Yes, and press . When the
screen goes black, disconnect power and repeat the above steps.
2.) If the “RGB” is not found, disconnect the AC power cord first. Then press the
buttons (don’t let them go) until the AC power cord is connected, and
wait for 2 to 3 seconds. When “RGB” appears, repeat the above steps.
2.2 OSD Controls
To make any adjustment, select the following:
1. Press (Menu) to show the OSD menu or disable the OSD menu.
2. Select the icon that you wish to adjust with the ( / or +/-) key in the menu.
3. Press (Menu) and then choose the item with the ( / or +/-) key.
4. Press (Menu) and then adjust the quality with the ( / or +/-) key.

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
13
2.3 OSD Function
1. Power button: Power on/off
2. Down button: Brightness
3. Up button: Volume
4. Menu button: Menu
5. Auto button: Auto adjustment
2.4 Main Menu
In the Main menu, there are the following items:
Color
Image Setting
Position
OSD Menu
Language
Misc.
Exit
For Color, check out the following:
Contrast
Brightness
Color Adjust
Color Temp
Back

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
14
For Image setting, check out the following:
Clock
Phase
Gamma
Sharpness
Back

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
15
In the Position, there are the following:
H. Position
V. Position
Back

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
16
In the OSD menu, there are:
OSD H. Pos.
OSD V. Pos.
OSD Timer
Back

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
17
In the Language menu, there are:
English
Frances
Germany
Spanish
Traditional Chinese
Simplified Chinese
Japanese

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
18
function on function off
In the Misc menu, there are:
Signal Source
Select VGA: Analogue VGA Input
Select DVI: Digital DVI-D Input
Select AV: Composite Video Input
Select SV: S-Video Video Input
Reset
Auto Dimming
Select Enable: function on
Select disable: Function off
Back

ARCDIS-1XX(P/G)(H) (TB-6028) User Manual
19
Chapter 3 Installation
This chapter describes how to install drivers and other software that will allow your
touch screen work with different operating systems.
3.1 Windows 7 Universal Driver Installation for
PenMount 6000 Series
Before installing the Windows 7 driver software, you must have the Windows 7
system installed and running on your computer. You must also have one of the
following PenMount 6000 series controller or control boards installed: PM6500,
PM6300.
3.1.1 Installing Software(Resistive Touch)
If you have an older version of the PenMount Windows 7 driver installed in your
system, please remove it first. Follow the steps below to install the PenMount
DMC6000 Windows 7 driver.
Step 1. Click Next to continue.
This manual suits for next models
6
Table of contents
Other Aplex Monitor manuals

Aplex
Aplex ADP-1174 User manual

Aplex
Aplex ADP-1120 User manual

Aplex
Aplex ADP-1080 User manual

Aplex
Aplex ARCDIS-132AP User manual

Aplex
Aplex OPD-1086 User manual

Aplex
Aplex FABS-107P User manual

Aplex
Aplex OPD-1086 User manual

Aplex
Aplex ARCDIS-118A User manual

Aplex
Aplex AHM-6XX6A User manual

Aplex
Aplex ADP-1081A User manual

Aplex
Aplex VIPAC-8 Series User manual

Aplex
Aplex ADP-1224A User manual

Aplex
Aplex ADP-1194 User manual

Aplex
Aplex ADP- 11x6 User manual

Aplex
Aplex ADP-1121 User manual

Aplex
Aplex ARCDIS -107 User manual

Aplex
Aplex ADP-1151W User manual

Aplex
Aplex ADP-1XX8P User manual

Aplex
Aplex ADP-1XX0A Series User manual

Aplex
Aplex ADP-1101 User manual