AquaDuna DUNOS RB 50 User manual

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 1
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
Operating instructions
DUNOS RB / RN

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 2
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
These operating instructions are part of the cleaner and must be
available to the user at all times. All safety information is to be
clearly instructed and must be observed. If this unit is passed on,
the operating instructions must be passed on as well.

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 3
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
Content
1 GENERAL INFORMATION.....................................................................................5
1.1 Function.................................................................................................................5
1.2 Design ...................................................................................................................6
1.3 Application.............................................................................................................7
2 TECHNICAL DATA.................................................................................................8
2.1 Dimensions............................................................................................................9
2.1.1 DUNOS RB 50.................................................................................................9
2.1.2 DUNOS RN 90.................................................................................................9
3 SAFETY INFORMATION......................................................................................10
4 DANGERS.............................................................................................................11
5 INSTALLATION AND MAINTENANCE ................................................................12
5.1 Installation ...........................................................................................................12
5.2 Commissioning....................................................................................................12
5.3 Maintenance........................................................................................................13
5.3.1 Required tools................................................................................................13
5.3.2 Disassembly...................................................................................................14
5.3.3 Assembly .......................................................................................................15
5.4 Replacement and wearing parts .........................................................................16
5.4.1 Fluid drive replacement parts ........................................................................16
5.4.2 Spray head replacement parts ......................................................................16
5.4.3 Fluid drive wearing parts................................................................................17
5.4.4 Wearing parts DUNOS RB / RN.....................................................................17

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 4
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
6 INTEGRATION AND CONTROL...........................................................................17
6.1 Integration into a cleaning system .......................................................................17
6.2 Control via manual control elements ...................................................................17
7 TROUBLESHOOTING..........................................................................................18
7.1 Emergency stop...................................................................................................18
8 TRANSPORT ........................................................................................................18
8.1 Delivery scope.....................................................................................................18
8.2 Transport and packaging.....................................................................................19
9 QUALITY ASSURANCE ........................................................................................20
10 DISPOSAL ...........................................................................................................20
I. SYMBOLS............................................................................................................21
II. TERMS USED.....................................................................................................22
III. LIST OF FIGURES.............................................................................................22

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 5
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
1 General Information
1.1 Function
The DUNOS RB / RN spray cleaners are spray units functioning in one
dimension which are driven by the cleaning medium. The cleaners have been
manufactured with as few components as possible. The machines are designed
with minimum clearance volume and are produced in Germany from inspected
materials. The surfaces and their roughness have already been monitored
during production.
The cleaning medium is supplied to the spray cleaner via a pre-filter. The spray
cleaner can be installed within the vessel in all positions. The connection is
made through a flanged nut. A G¾" flanged nut is used for the DUNOS RB50;
for the DUNOS RN90, a G1½" flanged nut. The inrushing medium generates an
output speed of 10 rpm to 16 rpm via a turbine with downstream gearbox. The
connection from the gearbox to the spray head is accomplished through a drive
shaft. Due to the design of the spray cleaner, the emitted cleaning agent stream
can be applied to the entire wall of the vessel with each revolution.
Important: The cleaning medium flows through a bypass, past the gearbox to
the spray head. This prevents braking elements and ensures the maximum flow
for the nozzles.
The spray cleaner can be operated with a wide range of
nozzle diameters. Therefore the unit can be perfectly
adapted to the cleaning task.
Figure 1: DUNOS RB

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 6
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
1.2 Design
The spray cleaner basically consists of three components.
Drive
The fluid drive generates a rotational movement by means of the cleaning
medium flow to drive the spray head.
Drive shaft
The drive shaft couples the drive with the spray head.
Spray head
The universal spray head can be fitted with different drive systems.
Figure 2: Design DUNOS RB / RN
Spray head
Drive shaft
Drive shaft
Fluid drive
Fluid drive
Spray head

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 7
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
1.3 Application
The spray cleaners of the DUNOS series are water-hydraulically driven
machines. The flowing medium drives the head, which functions in one
dimension. The water streams emitted by the nozzles strike the vessel wall. The
resulting impact and shear forces remove the deposits from the vessel wall.
Depending on the deposit to be removed, adding a portion of chemicals
determined by the respective user to the cleaning agent is recommended.
The unit is made of stainless steel 316 L, PTFE and PEEK. It is resistant to the
chemicals usually used in the pharmaceutical and food industries.
The units must only be used in closed vessels. Due to the high impact forces,
operation outside the vessel may lead to injuries.
These spray cleaners are constructed to be used only inside closed
vessels. They may be used only within the intended ranges. All non-
intended applications are prohibited. The units must only be used by
qualified and instructed persons.
Alterations or modifications are not covered by the manufacturer.

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 8
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
2 Technical Data
DUNOS RB50 DUNOS RN90
Length: 162 mm 192 mm
Built-in diameter: 65 mm 125 mm
Medium connection: G¾" G1½"
Number of nozzles: 4 - 32 4 - 32
Shape of nozzles: 2 - 5 mm 2 - 8 mm
Work pressure: 3 - 12 bar 3 - 15 bar
Cleaning radius: 2.5 - 4.5 m 4 - 9 m
Spray radius: 3.5 - 6 m 4 - 11 m
Weight: 0.8 kg 4.0 kg
Temperature range: 4 - 120 °C
Materials: Stainless steel 316L
PEEK
PTFE
Accessories (optional): Rotation monitoring
Connection parts
Special nozzles

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 9
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
2.1 Dimensions
2.1.1 DUNOS RB50
2.1.2 DUNOS RN90
Figure 4: Dimensions DUNOS RN 90
Figure 3: Dimensions DUNOS RB 50

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 10
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
3 Safety Information
The operator of the spray cleaner is obliged to instruct the operating personnel
as well as the personnel authorised to carry out the maintenance. All persons
working with rotating and spraying machines must be instructed regarding the
dangers these machines may present.
Persons not listed as operating or maintenance personnel are not permitted to
stay within the working range of the machine. The operator must ensure that the
necessary measures are taken.
As a matter of principle, the machines must only be maintained by suitable
qualified personnel. Only original replacement parts are to be used for
maintenance or repair. Use of non-original parts voids the warranty.

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 11
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
4 Dangers
The spray cleaners are subject to high pressures. Therefore we
expressly point out that only original parts are to be used for
maintenance and repair. Damage resulting from use of non-original
parts will not be accepted by the manufacturer.
The spray cleaner must be operated only in the environment it is
intended for. Operation is permitted only in closed vessels / rooms.
Pay attention to rotating parts.
The spray cleaner must not be turned on the machine head with
force. This can destroy the drive.
When working with the spray cleaner, make sure that your hands
cannot get caught between the nozzles and unit body.
Only authorised persons are allowed to stay within the operational
area of the spray cleaner.

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 12
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
5 Installation and Maintenance
5.1 Installation
The spray cleaner is screwed to the threaded connectors of the system with the
thread G¾" or G1½". When screwing onto the machine, make sure the thread is
first coated with a food grade lubricant such as Loctite 8014. Then the machine
DUNOS RB50 is to be firmly screwed to the load-bearing element with a SW 32
spanner, and the machine DUNOS RN90 with a SW 55 spanner.
Before setting the machine into operation, always check all parts for a
tight fit. The operator assumes sole liability for improperly mounted
machines.
5.2 Commissioning
If all pipelines / supply lines are tightly fastened to the spray cleaner and the
shut-off valves are closed, the spray cleaner is ready for initial commissioning.
Check the function of the pre-filter in the supply line to the spray cleaner and
make sure the filter body is inserted.
Before the initial commissioning, rinse out the supply line to the spray cleaner.
Metallic contamination and welding residues can destroy the spray cleaner.
For initial commissioning, make sure all air has been vented from the supply line
to the spray cleaner, especially with longer supply lines. This prevents pressure
shocks which can damage the spray cleaner.
If hand-operated valves are used, in order to avoid pressure impacts
they must not be opened abruptly.
For operation in automatic cleaning systems, the operator must familiarise
himself with the cutoff and/or emergency stop states of the system.

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 13
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
5.3 Maintenance
5.3.1 Required tools
DUNOS RB50
1. Spanner SW 21
2. Spanner SW 22
3. Spanner SW 5
4. Spanner SW 10
5. Tool set DUNOS RB50
Tool 1
Retaining clamps
DUNOS RN90
1. Spanner SW 46
2. Spanner SW 41
3. Spanner SW 10
4. Tool set DUNOS RN90
Tool 1
Tool 2
Retaining clamps
Figure 5: Tool set DUNOS RB50
Figure 6: Tool set DUNOS RD90

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 14
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
5.3.2 Disassembly
The spray cleaner is to be disassembled when the cleaner
1. should be maintained or
2. parts of the cleaner should be replaced. In this case, the repair
instructions apply.
The machine should be disassembled on a clean work surface. The required
tools should be ready at hand. The qualified personnel who carry out the
disassembly must be instructed.
Spanner 1
Spanner 2
Use spanners 1 and 2 to disconnect the fluid drive from the housing of the
spray cleaner. The drive shaft does not need to be removed.
Check the nozzles for free flow. If any residues are visible in the nozzles, use
a soft object to push them out of the nozzle opening. Be certain that the inner
surface of the nozzles is not scratched.
If there are any objects in the spray head, remove them. The drive shaft is
screwed to the lower end of the housing with screw 1. If the shaft interferes
when the head is cleaned, it can be unscrewed with spanner 3.
Check the dismounted fluid drive visually. Check if any contamination is visible
in the supply and/or on the output side of the drive. If contamination is present,
check whether it can be removed from outside. If it is not possible to remove
Figure 7: Disassembly

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 15
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
the contamination from outside, the housing of the fluid drive must be clamped
in the vice with the retaining clamps. Now the supply is unscrewed from the
jacket tube with the SW 46 spanner.
The drive unit can now be taken out of the jacket tube with a small flat pliers.
Now the entire annular gap of the drive is visible. If contamination is visible
here, it can be pushed out with a suitable screwdriver.
The jacket tube can now be blown free with 3 bar compressed air.
If the spray cleaner must be further disassembled for maintenance purposes,
observe the repair instructions. This procedure should only be performed by
very well-instructed personnel.
5.3.3 Assembly
If the fluid drive has been cleaned and the drive unit removed, now it must be
re-inserted. When doing so, take particular care that the gear on the lower end
of the drive unit is inserted into the gearbox under slight rotation.
Attention!! The gear must not press on the teeth of the gearbox.
If the drive unit is seated on the collar, the supply can be screwed on. To do
so, apply lubricant to the thread.
The supply is firmly tightened with spanner 1.
After the fluid drive is assembled, the drive shaft is screwed into the spray
head with the screw and spanner 3. This applies only when the shaft has been
removed. Now the thread of the spray head is provided with lubricant and
screwed into the fluid drive. When doing so, make sure the drive shaft is
inserted smoothly into the drive flange of the gearbox. The spray housing is
screwed to the drive housing with spanners 1 and 2.
Finally, the nozzles are screwed into the nozzle disc with spanner 3 and firmly
tightened. When so doing, lubricant must also be used.
Always make sure that all loosened threads are firmly re-tightened.

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 16
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
5.4 Replacement and wearing parts
5.4.1 Fluid drive replacement parts
Supply
Drive unit complete
Jacket tube
Gearbox unit
Base flange
O-rings (only for external mounting)
5.4.2 Spray head replacement parts
Dome
Dome ball bearing
Locking ring
Bearing ring
Dome sealing ring
Dome ball bearing
Drive gear
Spray housing
Figure 8: Exploded view, fluid drive
Figure 9: Exploded view, spray head

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 17
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
5.4.3 Fluid drive wearing parts
1. Drive unit
2. Gearbox unit
5.4.4 Wearing parts DUNOS RB / RN
Wearing parts consist of
Dome ball bearing
Dome sealing ring
Nozzle ball bearing
Nozzle sealing ring
6 Integration and Control
6.1 Integration into a cleaning system
If the spray cleaner is integrated into an automatically working system, make
sure that the function of the spray cleaner can be monitored. This can be done
by means of rotation monitoring or by an optical check. For optical check, the
function monitoring must be documented (system log).
6.2 Control via manual control elements
If the spray cleaner is controlled by manual control elements, make sure that
pressure shocks are avoided. Therefore the operating elements must be
opened and closed slowly. If they are exposed to steam, make sure that the
temperature does not exceed the specified limits. Monitoring of the spray
cleaner must be guaranteed.

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 18
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
7 Troubleshooting
7.1 Emergency stop
In order to force an emergency stop of the spray cleaner, it is imperative
for the system operator to be thoroughly familiar with the system
concept. It is essential to instruct personnel in emergency stop
procedures and to inform them of the elements necessary for an
emergency stop. The instruction of the persons authorised to perform
cleaning must be documented. The plant operator assumes sole
responsibility for all personal injury and property damage resulting from
faulty operation or faulty application.
8 Transport
8.1 Scope of delivery
The complete spray cleaner and operating instructions for the respective model
are included with delivery.
Please refer to the delivery papers for type options.
Figure 10: Delivery scope
Brief
instructions

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 19
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
8.2 Transport and packaging
Our products are carefully produced, assembled and tested. Should there
nonetheless be any reason for complaint, we will naturally ensure your complete
satisfaction within the scope of our warranty. We are also at your service after
the warranty expires.
When receiving a delivery, always check the packing list against the
delivery scope. After determining that delivery is complete, check the
goods for damage.
If there is any damage, it is essential to note it down on the shipping
documents. In case of damage, the forwarder must countersign the
documents.
To return parts, either keep the outer packaging or select a packaging
which will prevent damage to the units.

Rev. 1 Dunos RB_RN G Description 100728 / Docu / Cleaning tech / Dunos / Dunos RB_RN 20
AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany
Telephone: 07045 204980 / www.aquaduna.com
We reserve the right to make technical changes.
© Copyright by AquaDuna GmbH & Co. KG (2011) All rights reserved. Contact: www.aquaduna.com
9 Quality Assurance
For us, quality in design, production, assembly, final inspection and testing is a
matter of course. It is a mandatory precondition for the permanently efficient and
high-quality production of our demanding products. In order to guarantee our high
quality standards, we use a computer-assisted quality assurance system which we
have applied for certification according to ISO 9001:2008. Furthermore, all our
products are subjected to a final function test (100 % control). Thereby we assure
that only 100 % functional products leave our company.
10 Disposal
All the materials used in production of the spray cleaner are harmless to
the environment. The materials used are primarily stainless steel, PTFE
and PEEK. These materials can be disposed of in the ways established
for such disposal.
ATTENTION!! Make sure that there is no longer any contamination by
materials remaining from operation. To do so, use the suitable material
for rinsing the parts to be disposed.
This manual suits for next models