Aqualisa ilux Digital Series User manual

ilux
Digital
User instructions
ilux
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:49 Page 1

ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:49 Page 2

Contents
ilux Digital Shower and Bath – controller key Page 04
ilux Digital Shower – manual operation Page 05
ilux Digital Shower – pre-set operation Page 06
ilux Digital Shower – remote control Page 08
ilux Digital Bath – manual operation Page 09
ilux Digital Bath – pre-set operation Page 10
ilux Digital Bath – remote control Page 12
ilux Digital Shower with diverter & Bath with
diverter – controller key Page 13
ilux Digital Shower with diverter – manual operation Page 14
ilux Digital Shower with diverter – pre-set operation Page 15
ilux Digital Shower with diverter – remote control Page 17
ilux Digital Bath with diverter – manual operation Page 18
ilux Digital Bath with diverter – pre-set operation Page 19
ilux Digital Bath with diverter – remote control Page 21
Cleaning and maintenance Page 22
Remote control battery change Page 22
03
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:50 Page 3

ilux Digital Shower & Bath – controller key
Digital Shower control
1. Start/ Stop button with
Rotary temperature control
2. Shower pre-set buttons
3. Rotary flow control and
Pause button
Digital Bath control
1. Start/Stop button with
Rotary temperature control
2. Bath pre-set buttons
3. Child safety Lock/Unlock buttons
4. Rotary flow control
1
2
3
1234
04
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 12:08 Page 4

ilux Digital Shower control – manual operation
Digital Shower control
The shower can be operated either manually or once set, via the pre-set buttons.
To operate the shower manually follow the procedure below.
1. Press the Start/Stop button.
2. Rotate the temperature control to the desired position. The small red
or blue temperature LEDs will flash while adjusting, the white LEDs
remain solid, with more or less illuminating, to indicate the selected
temperature position set by the rotary temperature control dial.
3. Rotate the flow control to the desired position. The LEDs will
remain constantly lit, with more or less lights illuminating depending
on where the flow rate is positioned. On a lesser flow rate, less lights
will illuminate, on a greater flow rate more lights will illuminate.
The green LED will illuminate when set to ‘ECO’ flow rate.
4. If required, the shower may be paused during operation. Press the
Pause button. The LEDs will blink whilst the controller is in Pause
mode. Press the Pause button again to resume showering.
The shower will remain in Pause mode for 1 minute.
If showering is not resumed within 1 minute, the controller
will turn itself off.
5. Press the Start/Stop button to finish showering.
05
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:51 Page 5

Shower pre-set control
To store the pre-set button settings follow the procedure
below:
1. Press the Start/Stop button.
2. Select the desired temperature setting.
3. Select the desired flow rate.
4. Press and hold the desired pre-set button for 3 seconds.
The selected pre-set button will remain constantly lit
to indicate the controller has accepted the desired pre-set
temperature and flow rate settings.
5. Press the Start/Stop button to finish showering.
ilux Digital Shower control – pre-set operation
06
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:52 Page 6

ilux Digital Shower control – pre-set operation
6. Repeat the above procedure to store the remaining pre-set buttons.
7. Once set, the shower pre-set buttons may be erased and re-recorded by following the
procedure above as required.
To operate the shower using the pre-set buttons
1. Press the desired pre-set button. The shower will begin to operate
to your pre-defined temperature and flow rate.
2. Press the Start/Stop button to finish showering.
3. The temperature and flow rate settings can be overridden and the pause feature will be
active when the shower is operating in pre-set mode.
4. The shower can be operated manually or via the memory pre-set buttons.
Due to performance characteristics of combination boilers, inlet temperature change
may cause the following symptoms to be experienced during shower operation:
Temperature LEDs may flash; this is not necessarily changing the outlet
temperature.
The shower flow rate may vary.
Seasonal inlet temperature change may not offer a significant increase in shower
flow rate.
The operation of the Pause button will cause the combination boiler flow switch to
cut out. It may take a few moments to reach the desired temperature once
showering is resumed.
07
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:52 Page 7

ilux Digital Shower remote control
ilux Digital shower remote control is fully mobile and can be removed from the fixing cradle to
a more convenient location, operating up to 10m from the Digital shower control. The remote
control is water resistant though full submersion in water should be avoided.
1. To operate the shower in manual mode, press the Start/Stop button
on the remote.
2. Once set at the controller, start the shower using the pre-set buttons
by pressing the desired pre-set. The shower will start in the pre-set
flow and temperature.
When the remote battery power is running low, the green Eco
flow setting LED on the shower control will glow red.
ilux Digital Shower remote control
08
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:52 Page 8

ilux Digital Bath control – manual operation
The bath can be operated either manually or once set,
via the pre-set buttons. To operate the bath manually
follow the procedure below.
1. Press the Start/Stop button.
2. Rotate the temperature control to the desired position. The small red
or blue temperature LEDs will flash while adjusting, the white LEDs
remain solid, with more or less illuminating, to indicate the selected
temperature position set by the rotary temperature control dial.
3. Rotate the flow control to the desired position. The LEDs will
remain constantly lit, with more or less lights illuminating depending
on where the flow rate is positioned. On a lesser flow rate, less lights
will illuminate, on a greater flow rate more lights will illuminate.
The green LED will illuminate when set to ‘ECO’ flow rate.
4. Put the plug in.
5. Press the Start/Stop button to finish bath fill.
09
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:52 Page 9

The bath controller features a child Safety Lock to disable
the bath controls if a child is in the bathroom.
6. Once bath fill has been completed, press and hold the two
Lock/Unlock buttons simultaneously for 3 seconds to activate the
child Safety Lock feature.
The padlock icon button will remain illuminated to indicate the
controller is in child Safety Lock mode.
7. Press and hold the two Lock/Unlock buttons simultaneously for 3 seconds to unlock the
bath controller.
We do not recommend leaving a child unattended within a bathroom at any time.
Bath pre-set control
To store the pre-set button settings follow the procedure
below:
1. Press the Start/Stop button.
2. Select the desired temperature setting.
3. Select the desired flow rate.
4. Put the plug in.
ilux Digital Bath control – pre-set operation
10
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:52 Page 10

ilux Digital Bath control – pre-set operation
5. Press and hold the desired pre-set button for 3 seconds.
The selected pre-set button will continue to flash to indicate
the controller is in pre-set recording mode. The temperature
and flow control functions will be disabled whilst the bath
controller is in pre-set mode.
6. When the bath water is at the desired depth, press the Start/Stop
button to complete the recording of bath fill depth and temperature.
Differing user body mass will affect the overall depth of the bath.
Care should be taken to ensure the bath does not overflow.
7. Repeat the above procedure to store the remaining pre-set buttons.
8. Once set, the bath pre-set buttons may be erased and re-recorded by following the
procedure above as required.
To operate the bath using the pre-set buttons
9. Put the plug in and press the desired pre-set button. The bath will start at the pre-defined
temperature and flow rate.
Consideration should be given to the length of time the plumbing system requires
to reach the desired bath temperature and factored into the bath pre-set.
The temperature and flow rate settings can be overridden when the
bath is operating in pre-set mode.
To prevent accidental overfilling, once a bath has been filled
using the pre-set function, the controller pre-set buttons will be
disabled for 1 minute. The controls will still operate manually
if required.
The bath fill can be operated manually or via the memory pre-set buttons.
Due to performance characteristics of combination boilers, inlet temperature change
may cause the following symptoms to be experienced during bath operation:
The temperature LEDs may flash; this is not necessarily changing the outlet
temperature.
10.
11.
11
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:52 Page 11

ilux Digital Bath remote control
ilux Digital bath remote control is fully mobile and can be removed from the fixing cradle to
a more convenient location, operating up to 10m from the Digital bath control. The remote
control is water resistant though full submersion in water should be avoided.
1. Ensure the plug is engaged.
2. To operate the bath in manual mode, press the Start/Stop button
on the remote.
3. Once set at the controller, start the bath using the pre-set buttons
by pressing the desired pre-set.
To prevent accidental overfilling, once a bath has been filled
using the pre-set function the controller pre-set buttons will be
disabled for 1 minute. The controls will still operate manually
if required.
4. Whilst bathing, press the Hot Top Up button to provide a top up
of maximum temperature at minimum flow of blended water, this
will run for 1 minute before shutting off automatically.
5. Alternatively, press the Start/Stop button to finish the Hot Top Up flow.
When the remote battery power is running low, the green Eco flow setting LED
on the bath control will glow red.
Seasonal inlet temperature change may not offer a significant increase in bath
flow rate.
Bath flow rate may vary, therefore affecting bath pre-set depth. Consideration should be
given to Winter and Summer flow rates.
ilux Digital Bath remote control
12
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:53 Page 12

ilux Digital Shower with diverter & Bath
with diverter – controller key
Digital Shower control
1. Start/ Stop and divert button
with Rotary temperature control
2. Shower pre-set buttons
3. Rotary flow control and
Pause button
Digital Bath control
1. Start/Stop and divert button with
Rotary temperature control
2. Bath pre-set buttons
3. Child safety Lock/Unlock buttons
4. Rotary flow control
1
2
3
1234
13
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:56 Page 13

ilux Digital Shower with diverter – manual operation
Digital Shower control
The shower can be operated either manually or once set, via the pre-set buttons.
To operate the shower manually follow the procedure below.
1. Press the Start/Stop button, the shower will start in default outlet with
flow and temperature as per previous use.
To divert to alternative outlet, while showering, push and hold for 1.5
seconds to operate alternative outlet. Push and hold again to revert
back.
2. Rotate the temperature control to the desired position. The small red
or blue temperature LEDs will flash while adjusting, the white LEDs
remain solid, with more or less illuminating, to indicate the selected
temperature position set by the rotary temperature control dial.
3. Rotate the flow control to the desired position. The LEDs will
remain constantly lit, with more or less lights illuminating depending
on where the flow rate is positioned. On a lesser flow rate, less lights
will illuminate, on a greater flow rate more lights will illuminate.
The green LED will illuminate when set to ‘ECO’ flow rate.
4. If required, the shower may be paused during operation. Press the
Pause button. The LEDs will blink whilst the controller is in Pause
mode. Press the Pause button again to resume showering.
The shower will remain in Pause mode for 1 minute.
If showering is not resumed within 1 minute, the controller
will turn itself off.
5. Press the Start/Stop button to finish showering.
14
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:56 Page 14

Shower pre-set control
To store the pre-set button settings, follow the procedure
below:
1. Press the Start/Stop button.
2. Press and hold to select the desired outlet.
3. Select the desired temperature setting.
4. Select the desired flow rate.
5. Press and hold the desired pre-set button for 3 seconds.
The selected pre-set button will remain constantly lit
to indicate the controller has accepted the desired pre-set
outlet, temperature and flow rate settings.
6. Press the Start/Stop button to finish showering.
ilux Digital Shower with diverter– pre-set operation
15
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:56 Page 15

ilux Digital Shower with diverter – pre-set operation
7. Repeat the above procedure to store the remaining pre-set buttons.
8. Once set, the shower pre-set buttons may be erased and re-recorded by following the
procedure above as required.
To operate the shower using the pre-set buttons
1. Press the desired pre-set button. The shower will begin to operate
to your pre-defined outlet, temperature and flow rate.
2. Press the Start/Stop button to finish showering.
3. The temperature and flow rate settings can be overridden and the pause feature will be
active when the shower is operating in pre-set mode.
4. The shower can be operated manually or via the memory pre-set buttons.
Due to performance characteristics of combination boilers, inlet temperature change
may cause the following symptoms to be experienced during shower operation:
Temperature LEDs may flash; this is not necessarily changing the outlet
temperature.
The shower flow rate may vary.
Seasonal inlet temperature change may not offer a significant increase in shower
flow rate.
The operation of the Pause button will cause the combination boiler flow switch to
cut out. It may take a few moments to reach the desired temperature once
showering is resumed.
16
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:57 Page 16

17
ilux Digital Shower remote control
ilux Digital shower remote control is fully mobile and can be removed from the fixing cradle to
a more convenient location, operating up to 10m from the Digital bath control. The remote
control is water resistant though full submersion in water should be avoided.
1. To operate the shower in manual mode, press the Start/Stop button
on the remote, the shower will start in the last used flow and
temperature setting with water coming from the default outlet as set
on commissioning. To switch to an alternative outlet, press and hold
the Start/Stop button.
2. Once set at the controller, start the shower using the pre-set buttons
by pressing the desired pre-set. The shower will start in the pre-set
outlet, flow and temperature.
When the remote battery power is running low, the green Eco
flow setting LED on the shower control will glow red.
ilux Digital Shower with diverter remote control
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:57 Page 17

ilux Digital Bath with diverter – manual operation
The bath can be operated either manually or once set, via the pre-set buttons.
To operate the bath manually follow the procedure below.
1. Press the Start/Stop button, the bath will start in the default outlet
with flow and temperature as per previous use.
To divert to alternative outlet while bathing, push and hold for 1.5
seconds to operate alternative outlet. Push and hold again to
revert back.
2. Rotate the temperature control to the desired position. The small red
or blue temperature LEDs will flash while adjusting, the white LEDs
remain solid, with more or less illuminating, to indicate the selected
temperature position set by the rotary temperature control dial.
3. Rotate the flow control to the desired position. The LEDs will
remain constantly lit, with more or less lights illuminating depending
on where the flow rate is positioned. On a lesser flow rate, less lights
will illuminate, on a greater flow rate more lights will illuminate.
The green LED will illuminate when set to ‘ECO’ flow rate.
4. Put the plug in.
5. Press the Start/Stop button to finish bath fill.
18
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:57 Page 18

19
The bath controller features a child Safety Lock to disable
the bath controls if a child is in the bathroom.
6. Once bath fill has been completed, press and hold the two
Lock/Unlock buttons simultaneously for 3 seconds to activate the
child Safety Lock feature.
The padlock icon button will remain illuminated to indicate the
controller is in child Safety Lock mode.
7. Press and hold the two Lock/Unlock buttons simultaneously for 3 seconds to unlock the
bath controller.
We do not recommend leaving a child unattended within a bathroom at any time.
Bath pre-set control
To store the pre-set button settings follow the procedure
below:
1. Press the Start/Stop button.
2. Press and hold to select the desired outlet.
3. Select the desired temperature setting.
4. Select the desired flow rate.
5. Put the plug in.
ilux Digital Bath with diverter – pre-set operation
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:57 Page 19

ilux Digital Bath with diverter – pre-set operation
6. Press and hold the desired pre-set button for 3 seconds.
The selected pre-set button will continue to flash to indicate
the controller is in pre-set recording mode. The temperature
and flow control functions will be disabled whilst the bath
controller is in pre-set mode.
7. When the bath water is at the desired depth, press the Start/Stop
button to complete the recording of bath fill depth and temperature.
Differing user body mass will affect the overall depth of the bath.
Care should be taken to ensure the bath does not overflow.
8. Repeat the above procedure to store the remaining pre-set buttons.
9. Once set, the bath pre-set buttons may be erased and re-recorded by following the
procedure above as required.
To operate the bath using the pre-set buttons
Put the plug in and press the desired pre-set button. The bath will start at the pre-defined
outlet, temperature and flow rate.
Consideration should be given to the length of time the plumbing system requires
to reach the desired bath temperature and factored into the bath pre-set.
The temperature and flow rate settings can be overridden when the
bath is operating in pre-set mode.
To prevent accidental overfilling, once a bath has been filled
using the pre-set function, the controller pre-set buttons will be
disabled for 1 minute. The controls will still operate manually
if required.
The bath fill can be operated manually or via the memory pre-set buttons.
Due to performance characteristics of combination boilers, inlet temperature change
may cause the following symptoms to be experienced during bath operation:
The temperature LEDs may flash; this is not necessarily changing the outlet
temperature.
11.
12.
20
10.
ilux LAVINGTON User revisedv2.qxd:Layout 1 21/11/12 11:57 Page 20
This manual suits for next models
6
Table of contents
Other Aqualisa Control Unit manuals