Organic chemicals included by surrogate testing
VOCs (by surrogate testing
using chloroform)
Drinking water regulatory level
(MCL/MAC) mg/L
Inuent/
Unltered
Efuent/
Filtered
Percent
Reduction
alachlor 0.002 0.050 0.001 >98%
atrazine 0.003 0.100 0.003 >97%
benzene 0.005 0.081 0.001 >99%
carbofuran 0.04 0.190 0.001 >99%
carbon tetrachloride 0.005 0.078 0.0018 98%
chlorobenzene 0.1 0.077 0.001 >99%
chloropicrin — 0.015 0.0002 99%
2,4-D 0.07 0.110 0.0017 98%
dibromochloropropane (DBCP) 0.0002 0.052 0.00002 >99%
o-dichlorobenzene 0.6 0.080 0.001 >99%
p-dichlorobenzene 0.075 0.040 0.001 >98%
1,2-dichloroethane 0.005 0.088 0.0048 95%
1,1-dichloroethylene 0.007 0.083 0.001 >99%
cis-1,2-dichloroethylene 0.07 0.170 0.0005 >99%
trans-1,2-dichloroethylene 0.1 0.086 0.001 >99%
1,2-dichloropropane 0.005 0.080 0.001 >99%
cis-1,3-dichloropropylene — 0.079 0.001 >99%
dinoseb 0.007 0.170 0.0002 99%
endrin 0.002 0.053 0.00059 99%
ethylbenzene 0.7 0.088 0.001 >99%
ethylene dibromide (EDB) 0.00005 0.044 0.00002 >99%
haloacetonitriles (HAN)
bromochloroacetontrile — 0.022 0.0005 98%
dibromoacetontrile — 0.024 0.0006 98%
dichloroacetontrile — 0.0096 0.0002 98%
trichloroacetontrile — 0.015 0.0003 98%
haloketones (HK)
1,1-dichloro-2-propanone — 0.0072 0.0001 99%
1,1,1-trichloro-2-propanone — 0.0082 0.0003 96%
heptachlor (H-34, Heptox) 0.0004 0.025 0.00001 >99%
heptachlor epoxide 0.0002 0.0107 0.0002 98%
hexachlorobutadiene — 0.044 0.001 >98%
hexachlorocyclopentadiene 0.05 0.060 0.000002 >99%
lindane 0.0002 0.055 0.00001 >99%
methoxychlor 0.04 0.050 0.0001 >99%
pentachlorophenol 0.001 0.096 0.001 >99%
simazine 0.004 0.120 0.004 >97%
styrene 0.1 0.150 0.0005 >99%
1,1,2,2-tetrachloroethane — 0.081 0.001 >99%
tetrachloroethylene 0.005 0.081 0.001 >99%
toluene 1 0.078 0.001 >99%
2,4,5-TP (silvex) 0.05 0.270 0.0016 99%
tribromoacetic acid — 0.042 0.001 >98%
1,2,4-trichlorobenzene 0.07 0.160 0.0005 >99%
1,1,1-trichloroethane 0.2 0.084 0.0046 95%
1,1,2-trichloroethane 0.005 0.150 0.0005 >99%
trichloroethylene 0.005 0.180 0.0010 >99%
trihalomethanes (THMs) Inuent/
Unltered
Efuent/
Filtered
Percent
Reduction
bromodichloromethane (THM)
0.080 0.300 0.015 95%
bromoform (THM)
chloroform (THM)
chlorodibromomethane (THM)
xylenes (total) 10 0.070 0.001 >99%
Filter is only to be used
with cold water.
Filter usage must comply
with all state and local laws.
Testing was performed under standard laboratory
conditions, actual performance may vary.
Systems certied for cyst reduction may be used on
disinfected waters that may contain lterable cysts.
See owner’s manual for general installation conditions and
needs plus manufacturer’s limited warranty.
Do not use with water that is microbiologically
unsafe or of unknown water quality without adequate
disinfection before or after the system.
This system has been tested according to NSF/ANSI 42, 53 & 401 for reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specied in NSF/ANSI 42, 53 & 401.
NSF/ANSI 42 Minimum
Reduction
Overall %
Reduction Results
Chlorine Reduction,
Free Available <0.5 mg/l 96.06% Pass
Chloramine Reduction,
Free Available <0.5 mg/l 96.06% Pass
Particulate Reduction 85% 99.9% Pass
NSF/ANSI 53 Minimum
Reduction
Overall %
Reduction Results
Cyst Live Cryptosporidium & Giardia 99.95% >99.95% Pass
Mercury Reduction pH 8.5 <2 ug/L >96.7% Pass
Mercury Reduction pH 6.5 <2 ug/L >96.6% Pass
Lead Reduction pH 6.5 <10 ug/L >99.3% Pass
Lead Reduction pH 8.5 <10 ug/L >99.4% Pass
MTBE Reduction <5 ug/L 91.2% Pass
Turbidity <0.5 NTU 99.1% Pass
VOC Surrogate Test 95% 95% Pass
Asbestos Reduction 99% >99% Pass
NSF/ANSI
401
Maximum
Concentration
Minimum
Reduction
Overall %
Reduction Results
Phenytoin 30 ng/L 95.50% 95.6% Pass
Ibuprofen 60 ng/L 95.3% 95.4% Pass
Naproxen 20 ng/L 96.3% 96.4% Pass
Estrone 20 ng/L 96.30% 96.5% Pass
Bisphenol A 300 ng/L 98.80% 98.9% Pass
Nonyl phenol 200 ng/L 97.50% 97.5% Pass
• All contaminants reduced by this lter are listed.
• Not all contaminants listed may be present in your water.
• Does not remove all contaminants that may be present in tap water.
Performance Data Sheet for the Aquasana Clean Water Machine
Models Replacement Rated capacity Operating
pressure range
Operating
temp. range
Rated
ow
AQ-CWM-RB1, AQ-CWM-RB2, AQ-CWM-RB1W, AQ-CWM-P-W, AQ-
CWM-P-B, AQ-CWM-D-W, AQ-CWM-D-B, AQ-PCBK-GC, AQ-PC-GC
AQ-CWM-R-D,
AQ-CWM-R-R
320 gallons
1200 liters
20-70 psi
137-482 kPa
40-90° F
4.44-32.2° C
0.5 gpm
1.8 lpm
Manufactured by: Aquasana, Inc. 6310 Midway Road · Haltom City, Texas 76117 · 866.662.6885
System tested and certied by NSF International against
NSF/ANSI Standard 42, 53 and 401 for the reduction of
the claims specied on the Performance Data Sheet and
at www.nsf.org.
Aquasana offers an extensive assortment of water lters and vessels to complement a healthy lifestyle.