AS Medizintechnik GmbH • Sattlerstrasse 15, 78532 Tuttlingen, Germany • Tel 07461/966326 • Fax 07461/9663288
Revision status: A Constructed / revised: 01.03.2012 Constructed by: ns
Instruction of use
AS Steribox
Information on Cleaning
The filter can remain in the box during all manual and mechanical cleaning operations. The box can be manually cleaned
and disinfected with all common neutral, non abrasive cleaning agents. Do not use metal brushes on the box. Stubborn
deposits can be removed in an ultrasonic bath.
The box is dish washer proof using any common cleaning agents, and suitable for all common chemical and thermal
desinfection methods. It is important that the box is rinsed to ensure all residues are removed. The final rinse should
be carried out with deionised water. Following these cleaning instructions will ensure the correct functioning of the AS
Steribox and enhance its lifetime.
Information on storage
The shelf life of the sterile content as in accordance to DIN 58953-9, should be determined by the protocols of your
Institution. It is important to ensure that the sterile content is protected from dust, dirt, humidity, mechanical damage and
hazardous substances during storage.
Visual inspection
Prior to cleaning, it is important that the AS Steribox is checked for any damage that could allow the penetration of
germs. Any damage must be rectified by qualified and trained personnel. Damaged parts must be replaced.
Safety seals
Unauthorised opening can be prevented by using safety seals attached between the lid and the base of the box.
Filters
The filter must be periodically replaced. The time scale will depend on the type of filter in use and the instructions of your
Institute.
Recommended sterilisation methods:
Autoclave sterilisation at 121°C or 134°C
More methods:
Formaldehyde, ethylene oxide at maximum of 65°C. The ventilation time required is twice that of a metal container. (gas-
plasma sterilisation STERRAD®)*
A CE-marked system, the AS Steribox fulfils the requirements of DIN 58952, 58953 / EN 868-1, 868-8, 554 / ISO 11607 /
DIN EN ISO 17664, 13485, 11137-1.
Please retain this manual for future reference. Information is correct at time of going to press. Any use of the AS Steri-
box, other than detailed within this manual, will invalidate the manufacturer‘s guarantee and may impair its performance.
*STERRAD®is a registrated brand mark of the Johnson & Johnson company.
AS MEDIZINTECHNIK GMBH DOES NOT ACCEPT RESPONSIBILITY IF THIS CUSTOMER INFORMATION HAS BEEN
VIOLATED PROVABLY.
Page 1 of 2
AS Medizintechnik GmbH • Sattlerstrasse 15, 78532 Tuttlingen, Germany • Tel 07461/966326 • Fax 07461/9663288
Revision status: A Constructed / revised: 01.03.2012 Constructed by: ns
Instruction of use
AS Steribox
To open
Press down the red button
1. Simultaneously pull the
lower part of the safety
lock outwards 2. Lift the
upper part to unlock 3.
To close
To close the box, clip on the
upper part of the safety lock
and press down.
To change the filter
Insert a flat blade into the
filter support recess and
remove the cover.
Remove the old filter and
replace it. The new filter
should have the rough
side facing the out.
Replace the coloured plas-
tic disk in the filter cover.
The filter cover can then
be snapped back into
place. The box is now
ready for use.
Page 2 of 2

Other AS Laboratory Equipment manuals

AS QC2 Series User manual

AS

AS QC2 Series User manual

AS QC System M2 Series User manual

AS

AS QC System M2 Series User manual

AS QC2 Series User manual

AS

AS QC2 Series User manual

AS M0026 User manual

AS

AS M0026 User manual

Popular Laboratory Equipment manuals by other brands

Endress+Hauser Liquistation CSF33 operating instructions

Endress+Hauser

Endress+Hauser Liquistation CSF33 operating instructions

Pasco Scientific CI-6689A instruction sheet

Pasco Scientific

Pasco Scientific CI-6689A instruction sheet

Pecon P Lab-tek Series manual

Pecon

Pecon P Lab-tek Series manual

VistaLab Ovation M Replacement manual

VistaLab

VistaLab Ovation M Replacement manual

STILLA Prism6 H24000.3 user manual

STILLA

STILLA Prism6 H24000.3 user manual

Excelitas Technologies OmniCure S1500 PRO user guide

Excelitas Technologies

Excelitas Technologies OmniCure S1500 PRO user guide

TKA LabTower EDI operating instructions

TKA

TKA LabTower EDI operating instructions

Getinge 8666 Service instructions

Getinge

Getinge 8666 Service instructions

Retsch BB50 manual

Retsch

Retsch BB50 manual

Thermo Scientific REDOX/ORP 9678BNWP user guide

Thermo Scientific

Thermo Scientific REDOX/ORP 9678BNWP user guide

Allied Telesis AT-7101GHTm installation guide

Allied Telesis

Allied Telesis AT-7101GHTm installation guide

Telemark Cryogenics 1200 instruction manual

Telemark Cryogenics

Telemark Cryogenics 1200 instruction manual

PPG Semco 1088 Operating Instructions & TroubleShooting Guideline

PPG

PPG Semco 1088 Operating Instructions & TroubleShooting Guideline

ThermoFisher Scientific TX-200 instruction manual

ThermoFisher Scientific

ThermoFisher Scientific TX-200 instruction manual

Specac Quest ATR GS10800 Series quick start guide

Specac

Specac Quest ATR GS10800 Series quick start guide

Biosan WB-4MS User instructions

Biosan

Biosan WB-4MS User instructions

Agilent Technologies PR02 Operation manual

Agilent Technologies

Agilent Technologies PR02 Operation manual

Siemens ADVIA Centaur Safety notes

Siemens

Siemens ADVIA Centaur Safety notes

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.