ASG TLB-D User manual

ASG, Division of Jergens, Inc.
15700 S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: asginfo@asg-jergens.com | Web: www.asg-jergens.com | Revision: 8/24/2020 | Page 1 of 6
TLB-D Brushless Electric Screwdrivers
Operation Manual
Table of Contents
Overview ...................................................................................................................1
General Safety Rules...................................................................................................1
Safety Instructions......................................................................................................2
Description of Operation.............................................................................................2
Grounding Instructions...............................................................................................2
Installation Instructions ..............................................................................................2
Panel Specications....................................................................................................3
Counting Set-Up Instructions......................................................................................4
Torque Adjustment Operation .....................................................................................6
Servicing ....................................................................................................................6
Warranty....................................................................................................................6
Overview
Thank you very much for selecting the TLB-D Brushless Electric Screwdriver.
Read this manual before placing tool in service or operation. Save
these instructions for future reference. It is the responsibility of the
employer to place the information in this manual into the hands of
the operator. Failure to observe the following warnings could result
in injury. When using electric tools, basic safety precautions should
always be followed to reduce the risk of re, electric shock, and
personal injury. After having read these instructions, keep them in a
convenient place so you or the operator can refer to them whenever
necessary.
Note: ASG is not responsible for customer modication of tools for
applications on which ASG was not consulted
PLEASE NOTE: When repairing or replacing tools or
components on any TLB Series purchased in 2016 or prior,
please contact ASG representative
General Safety Rules
Electrical Safety
• Keep work area clean and well lit.
• Electric screwdriver plugs must match the outlet. Never modify the plug in any
way. Do not use any adapter plugs with earthed (grounded) electric screwdrivers.
These precautions will reduce the risk of electric shock.
• Do not expose an electric screwdriver to rain or wet conditions as this will increase
the risk of electric shock.
• Never use the cord to carry, pull, or unplug the electric screwdriver. Keep cord
away from heat, oil, sharp edges or moving parts. Damaged or entangled cords
increase the risk of electric shock.
Personal Safety
• Stay alert and pay attention to your surroundings when operating an electric screwdriver.
Do not use an electric screwdriver while you are tired or under the inuence of drugs,
alcohol, or medication, as this could result in serious personal injury.
• Ensure the switch is in the off position before plugging in to avoid accidental
starting.
• Keep proper footing and balance at all times.
Electrical Screwdriver Use and Care
• Use the correct electric screwdriver and power supply for your application.
• Do not use an electric screwdriver if the switch is broken. Any electric screwdriver
that cannot be controlled with the switch is dangerous and must be repaired.
• Disconnect the plug from the power source before making any adjustments,
changing accessories, or storing the electric screwdriver. Such preventive safety
measures reduce the risk of starting the electric screwdriver accidentally.
• Keep out of reach of children and untrained personnel. Electric screwdrivers are
dangerous in the hands of untrained users.
Service
• Have your electric screwdriver serviced by ASG. This will ensure that the safety and
quality of the electric screwdriver is maintained.

ASG, Division of Jergens, Inc.
15700 S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: asginfo@asg-jergens.com | Web: www.asg-jergens.com | Revision: 8/24/2020 | Page 2 of 6
TLB-D Brushless Electric Screwdrivers
Operation Manual
Grounding Instructions
The tool should be grounded while in use to protect the operator from electric shock.
The tool is equipped with a three-conductor cord and three-prong grounding-type plug
to t the proper grounding-type receptacle. The green (or green and yellow) conductor
in the cord is the grounding wire. Never connect the green (or green and yellow) wire
to a live terminal.
Description of Operation (Continued)
Do not operate this tool without protective earth connected
Green and Yellow Earth
Blue Neutral
Brown Live
Safety Instructions
• Make sure the switch is in the OFF position and tool is unplugged when changing a bit
• Do not allow chemicals such as acetone, benzene, thinner, trichloroethylene ketone, or
other similar chemicals to come in contact with the screwdriver housing as damage
will result.
• Do not drop or misuse the screwdriver.
• Do not adjust the torque setting higher than 8 on the torque scale.
• There should be a tool rest interval for cycles of three seconds or longer. This tool is
intended for a duty cycle of 0.8 seconds on, 3.2 seconds off.
• Do not tighten more than 800 tapping screws (size: 3mm. Length: 5mm) per hour.
• Do not use this screwdriver for tightening wood screws.
• Do not operate the Forward/Reverse Switch while the motor is running.
• Turn the switch to the OFF position and unplug the screwdriver and power supply
when the tool is not in use
• Always grasp the plug of the power cord when plugging in/unplugging.
• Always secure the power supply to avoid movement.
• If the power supply overheats or is overloaded with maximum current rating, the
high-speed fuse will cut off the power. If this situation continues, stop operation
immediately and contact ASG for repair.
• Do not disassemble the electric screwdriver or try to repair it yourself.
• When power supply is not in use, please turn the main power switch OFF and
unplug the power supply.
Description of Operation
Inserting/Removing Bit and Bit Type
• Push up the holder clamp to unlock it.Thus, the bit can be freely attached and detached.
• Insert the power plug into a receptacle and set the switch to “F” (forward position).
• Apply the bit to the screw head and either press the lever or push to start the tool.
The switch will be turned ON to start the motor running.
• When the screw is tightened and reaches the torque that you had set, the tool will
stop automatically.
• To reverse the screw, set the changeover switch to “R” (reverse position).
Installation Instructions
• Use the power supply voltage recommended in the specication of this manual.
• When using a commercial power supply be sure to set up circuit and safety
breakers. You must also properly ground the mechanisms.
• The temperature and humidity should be kept at appropriate levels.
• Do not set up the power supply in a room that has poor ventilation and where it
may be exposed to dust and metallic particles.
• Do not put anything on top of power supply
• Attach the power supply securely to a at, stable surface.
• Do not permit unauthorized personnel to operate this power supply or electric screwdriver.
• Do not set up the power supply near any high voltage machinery
• Avoid setting up or storing the power supply in wet or oily environments or where
it might be exposed to corrosive or ammable gases.

ASG, Division of Jergens, Inc.
15700 S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: asginfo@asg-jergens.com | Web: www.asg-jergens.com | Revision: 8/24/2020 | Page 3 of 6
TLB-D Brushless Electric Screwdrivers
Operation Manual
Panel Specications
No. Name Function
1 3-Colored Light To show operation is OK, NG, or the mode condition
2 Panel To show set value, set screws number and other value
3 Power Switch Push ve seconds: to disable COUNTING FUNCTION CLEAR
Push three seconds: CLEAR
4 SELECT key Push three seconds: Enter the selection
5 Up Key When entering the selection, this key increases value
6 Down Key When entering the selection, this key decreases value
7 Reset Restore to factory settings
S+P Automatic learning
UP+P Waiting time mode
UP+DOWN Buzzer mode
S+UP If press together to enable P/R/S button, and then press again
to disable P/R/S button

ASG, Division of Jergens, Inc.
15700 S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: asginfo@asg-jergens.com | Web: www.asg-jergens.com | Revision: 8/24/2020 | Page 4 of 6
TLB-D Brushless Electric Screwdrivers
Operation Manual
Counting Set-Up Instructions
Push three seconds to enter the selection ) SL===SC===At===Ht===Lt===LL===Ns===Rn===Rt <Conrm>
Function Name Set-Up Time and Value Description Buzz Time/Light Factory Default Settings
SL 01-05/UU Screw List --- ---
SC 1-99 Counting number / count-down only --- 05
At 0.1-9.9 Automatic zero time / Signal output time --- 1.0
Ht 0.1-9.9 Ht time Stop time can be used to check
for stripped screws
Five buzz and LED red ash 2.0
Lt 0.01-9.9 Lt time will show early shutoff Two buzz and LED red ash 0.00
LL 0.01-9.9 Reconrm time after fastening --- 0.00
Ns Y or N Ns: Set the function of stopping the screw-
driver when any error message occurs.
Y: Stop the screwdriver when any error
occurred meanwhile, Reverse is OK;
Restore by pressing “S” button
N: screwdriver could operate continually
when any error occurred.
Rn Y or N Rn: Set the count-up mode for reverse
Y: Count for each reverse;
N: Only count once when reverse
Rt 0.01 – 9.99 Rt: Set auto reverse time after the
screwdriver shuts off.
Backward to Count-Up 1 COUNT When screwdriver is in reverse, the
counter will subtract count
--- ---
LC --- Keypad LOCK P/S/R button
UN --- UNLOCK
Ln --- Automatic learning. LED keeps ash of light ---
Buzzer En Wrong Set-Up --- Wrong Set-Up, such as Lt>Ht Three buzz and LED red ash.
Automatically show En
---
dt Standby time Seconds Buzz if set-number of screws are not
completed in the allotted set time for each
screw fastening
Lasting buzz s and LED red ash ---
Tt Working time for
a set of screwdriver
Minutes Buzz if set-number of screws are not
completed in the allotted set time for a
set screw fastening
Lasting buzz s and LED red ash

ASG, Division of Jergens, Inc.
15700 S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: asginfo@asg-jergens.com | Web: www.asg-jergens.com | Revision: 8/24/2020 | Page 5 of 6
TLB-D Brushless Electric Screwdrivers
Operation Manual
Counting Set-Up Instructions (Continued)
• In the set-up, if Lt and LL show “02.”it means 0.02, push P to adjust decimal.
• During operation, LED will show three colors: OK is green light; NG is red light;
standby learning is orange light.
• EA-BD PCB has three kinds of signal, OUTPUT OK1, OKALL and NG
• Output users need input voltage to drive the buzzer, the input voltage can’t be
over DC24V 10mA.
• There is a new function in the screwdriver that will judge a NG if there is a start
signal and it is OFF before Lt.
Push both UP+DOWN set up the buzzer:
Counting Set-Up Instructions (Continued)
Ht/Lt Description:
• Ht/Lt sets up the period of time. If the tool stops within the set period, it means
OK. In contrast, it will be (NG) if it stops before Lt or after Ht. The LT accepts 0.00,
but it can be increased or decreased in SELECT.
• To shut down the count: If count needs be shut down, push P key for ve seconds
until no gures on the panel, meanwhile LED 1 will show green light.
• If set value need be reset during counting, push for three seconds.
• Simulated-learning: While electric screwdriver is not used, push S key and then
push P key to enter simulated-learning procedure; SL(S)===SC(S)===At(S)===
Test Data===(P)
1. Show SL (Screw List), select UP/DOWN to change number and then push S (conrm)
2. Show SC (counting number), select UP/DOWN to change number and then push S (conrm)
3. Show At (automatic zero), UP/DOWN to change value; then push P (conrm)
4. Enter simulated-learning (LED 1 will keep ash)
• LED light will ash in simulated-learning. Push P key to record value after
simulated –learning.
• UP and P key can set up waiting time.
• Push R key to restore to factory settings.
ON Fastening a screw, completing work and mistaken operation, buzzer
will be on.
OFF Wrong operation will be buzzed.
FF Work completed and wrong operation will cause buzz.
EF As one screw is fastened and work is completed, buzzer will be on; as
mistake made has no buzz.

ASG, Division of Jergens, Inc.
15700 S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: asginfo@asg-jergens.com | Web: www.asg-jergens.com | Revision: 8/24/2020 | Page 6 of 6
TLB-D Brushless Electric Screwdrivers
Operation Manual
Torque Adjustment Operation
• Determine the torque output of the tool with a torque tester such as the ASG DTT
or DTT-L.
• Increase or decrease the torque by rotating the Spring Adjusting Ring. Rotating
the ring clockwise to a higher number on the torque scale increases torque output
while rotating the ring counterclockwise to a lower number decreases the torque
output.
• Continue to check the adjustment with a torque tester until you are satised with
the torque output. If you are making nal torque adjustments on line, always start
below the desired torque and work upward.
• The torque scale on the tool goes from 0 to 8. Only the even numbers appear:
2,4,6, and 8. This is not the actual torque the tool is going to produce. The
numbers on the scale are only a point of reference.
Servicing
Maintenance and Inspection
• Do not use the tool more than 8 hours a day.
• Do not let the motor and power supply get over heated. Do not run more than
10-15 screws/minute.
• If you use the tool more than 8 hours a day, have the tool evaluated for
preventative maintenance.
• Inspect tool cords periodically. If damaged, contact ASG.
• Do not remove any labels.
Using non-ASG replacement parts may result in decreased
tool performance and increased maintenance and may void all
warranties.
All repairs and maintenance of this tool must be performed by ASG
ASG is not responsible for customer modication of tools for
applications on which ASG was not consulted.
It is the responsibility of the employer to place the information in
this manual into the hands of the operator.
Servicing (Continued)
DO NOT ATTEMPT TO REPAIR THIS ELECTRIC SCREWDRIVER
SAVE THESE INSTRUCTIONS - DO NOT DISCARD
Warranty
The warranty is 1 year after delivery. If any troubles should occur, please contact ASG.
In the following cases, the purchaser shall pay for parts and labor regardless of the
terms of warranty:
• Failure due to improper handling.
• Failure due to product modication or improper processing.
• Failure due to causes beyond control (for example earthquake or re).
• Consumables, replaceable parts, and replacement work expenses.
PLEASE NOTE: When repairing or replacing tools or components on any TLB
Series purchased in 2016 or prior, please contact ASG representative
Table of contents
Other ASG Power Tools manuals
Popular Power Tools manuals by other brands

Hakko Electronics
Hakko Electronics FR-410 instruction manual

Tradeflame
Tradeflame 218034 product manual

Ozito
Ozito LRTK-036 instruction manual

Makita
Makita PC5010C instruction manual

Greenlee
Greenlee GATOR LS100L Operation manual

Mitsubishi Electric
Mitsubishi Electric MELDAS 600M Series instruction manual