履歴の転送と消去
About Data Transmission Function
Maximum of 100 measurement
results are recorded with
time stamps.
:
:
2017/08/17 09:30:45,12.3,20.4
2017/08/17 09:30:50,12.3,20.4
2017/08/17 09:30:55,12.4,20.4
Android devices / iPhone
Laptop or PC +
USB NFC Reader/Writer
Example of
data history
Install a software to readout the NFC tag ahead of time.
Android devices / iPhone Laptop or PC + USB NFC Reader/Writer
Example of data history read out
Preparation
(1) Software installation
LLL : Lower limit error.
HHH : Upper limit error.
OOO : Zero setting complete.
nnn : External light error.
AAA : Zero setting error.
ooo : Low Sodium index error.
Set the date and time (year [the last two digits of the western calendar], month, date, time and minute) prior to data history readout.
(2) Date and time setting
NReset the date and time when batteries are removed for 24hours or more.
h
Year hYear
h
Month
h
Day
h
Day
h
Hour
h
Minute
h
Minute
10's place 10's place 10's place1's place 1's place 1's place
While powered on…
(Example image)
0 - 9 0 - 9 0 - 9 0 - 901 - 12 0 - 3 00 - 23 0 - 5
Press the 水Key until the desired number is displayed.
*For "time", set the time in
24 hour notation
99
17 99 12 31 24 60
(Seconds : Fixed 00)
Top right screen display during date and time set up
Year :Month :Day :Hour :Minute :
Pressing the 水Key will change the number.
20.4
12.3
dAt
End
Android devices / iPhone Laptop or PC + USB NFC Reader/Writer
*Do not move it.
(Hold for 1 second or more.) *Do not move it.
(Hold for 1 second or more.)
*NFC position on Android device or iPhone differs to the model.
Data history readout
All recorded data stored in this instrument are read out.
* If data history is not read out, bring both in contact and move the one that is over the other device in
a forward and back or left and right in a small motion.
渦Key
水Key
0 second 1 second 2 seconds 3 seconds
2. Press the
渦Key.
Delete data
history
Delete data history
If not deleting
the data history.
* Press two times
within one second.
End without
deleting the
data history.
1. Quickly (3 seconds or less) do the followaing key operation.
While powered
on…
(Example image)
Press the
水Key.
20.4
12.3 dEL
y_n
dEL
dEL
dEL
End
This instrument stores maximum number of 100 measurement data. This instrument is
equipped with NFC(Near Field Communication)technology.
Data history can be accessed by bringing PAL-NFC to any Android devices, iPhone or PC-linked
USB NFC Reader/Writer* (in conformance to PC/SC specification).
*Operation tested with SONY USB NFC Reader PaSoRi RC-S380.
Caution Data history exceeding 100 will overwrite old activity with new data, replacing the
oldest recorded information first.
Data history can be exported to Microsoft(R) Excel (R)(for Windows(R)) using a PAL NFC
software "ATAGO Logger (NFC)."
Applicable Application Software (app) "NFC Reader"
* If an NFC tag reader app is already installed on the Android
devices or iPhone, this app can be used.
* Be sure to establish the PC and IC card
reader/writer connection in advance by
setting up (and installing the driver) IC card
reader/writer.
* Data history can be read out by holding up
the USB NFC Reader/writer to the PAL unit.
1. Launch ATAGO Logger.
2. Bring the bottom part (where the "NFC" logo is) of PAL
in contact with the NFC mark on the IC card reader/writ-
er.
(((・NFC
(((・NFC
1. Launch NFC Reader (or other NFC tag reading app).
2. Position NFC on Android device or iPhone to the 'NFC' logo
at the bottom portion of the PAL then bring in contact.
NData history can be read out while PAL is powered off.
NData history readout will not delete the stored data history.
(a) While pressing the 渦Key, press the 水Key two times.
(b) Quickly release the 渦Key.
All data history will be deleted from
this instrument.
Caution Deleted data history can
not be restored.
NA data history can not be
selected.
Caution Bring PAL and Android devices, PAL and iPhone or PAL and
USB NFC Reader/writer as close to each other as possible.
(Position it so that the distance between both devices are 5mm or less.)
Back side of the body
Instrument’s serial number
Last 10 digits of NFC chip number (NFC’S serial number)
You can use the NFC’S serial number to identify which
instrument the readings correspond to.
You can check the NFC chip number (serial number) by using an
app that can read the serial number.
Note: Not all NFC apps capture the NFC’S serial number
Suggested app: “NFC Tools”
2302K Printed in Japan
(0~53%)
Store the instrument in a dry place away from direct sunlight.
Exposure to humidity may cause condensation inside, and
exposure to direct sunlight may cause the plastic to warp.
・Cleaning Clean and dry the sensor area thoroughly after use, leaving no sample
residues or water.
〈For oily samples:〉
Remove oily residues with mild soap, and then, rinse with water.
・Storage Store the instrument away from direct sunlight at a stable temperature
with as little fluctuation as possible.
Storage And Maintenance
The Automatic Temperature Compensation (ATC) feature is based on temperature detected by the thermo sensor located near the sensor area.
ATC may not work correctly when the temperature of the sensor area is not the same as the actual temperature of the sample. When measuring a
hot or cold sample, let it sit on the sensor for approximately 20 seconds and measure, or take multiple readings until measurements become stable.
Automatic Temperature Compensation
Read and follow all safety instructions before operating the instrument.
・When measuring hazardous materials, use proper safety procedures, materials, and clothing to avoid personal injury. Anyone
handling hazardous materials should understand its properties and its safety requirements. ・If the instrument is dropped or subjected to a strong
impact, contact your supplier for inspection. ・Do not attempt to repair, modify, or disassemble the instrument.
・Before use, carefully read the instruction manual and fully understand the function and operation for each part of the
instrument. ・ATAGO is not liable for any loss and damage caused by the measurement and use of this instrument. ・If this instrument is used to
measure highly acidic samples, the sensor section and sample stage may be damaged, resulting in inaccurate measurements. ・Do not use any
metal tools when applying sample to the sensor section. The metal can damage the sensor section. If the sensor section is scratched or damaged,
inaccurate measurements will occur. ・When the unit needs to be washed, use water at a temperature not exceeding 50℃. ・Only use the
specified battery type. Observe proper polarities, properly aligning the anodes and cathodes. ・Do not leave the instrument in a location exposed
to direct sunlight or near a heat source for any extended period of time. ・Do not change the ambient temperature of the instrument suddenly.
・Do not place the instrument where it will be subject to strong vibrations. ・Do not use the instrument where there are excessive amounts of
dust. ・Do not store the instrument in an extremely cool area. ・Do not set or drop heavy objects on top of the instrument. ・Loosen the
battery compartment cover for air transportation. ・The instrument is water-resistant, not waterproof, and should not be submerged.
WARNING
CAUTION
Safety Precautions
The instrument is warranted for one year from the date of purchase. This warranty is void if the instrument shows evidence of the following.
Send the included batteries as well if they are still in use. ・Having been disassembled by unauthorized personnel ・Damages to the sensor section
・Water damage or having been dropped ・Having been misused and/or operated outside the environmental specifications
・Leakage from batteries other than those included with the unit Repair services are available for a fee after the warranty expires. Contact an
ATAGO authorized service center for service and support.
Repair And Warranty
Please have the serial number information ready when contacting a service center.
Headquarters: The Front Tower Shiba Koen, 23rd Floor
2-6-3 Shiba-koen, Minato-ku, Tokyo 105-0011, Japan
TEL: 91-22-28544915 / 40713232
TEL: 66-21948727-9 ,66-21171549
ATAGO's instruments are rigorously inspected to ensure each
unit meets the highest standards of quality assurance.
1.Insert a coin in the groove
on the battery compartment
cover.
Turn the coin
counterclockwise to remove
the cover.
2.Insert batteries, observing
the correct polarity.
3.Align the cover and push
it down.
4.Close the battery
compartment cover by
pushing the cover in with a
coin in the groove and
turning it clockwise until it
stops.
※Turning excessively may
cause malfunction.
Open Close
O-ring
mWhen the O-ring on the battery compartment cover is
dirty or damaged, the water resistance may be
compromised.
O
P
E
N
C
L
O
S
E
Groove
O
P
E
N
C
L
O
S
E
Inserting Batteries
O
P
E
N
C
L
O
S
E
O
P
E
N
C
L
O
S
E
Specifications
Measurement range Brix 0.0 to 90.0% , Temperature10.0 to 100℃
SALT(Std) 0.00 to 15.00% (g/100g)
Resolution Brix 0.1% SALT 0.01% Temperature 0.1℃
Measurement accuracy Brix ±0.2% Temperature ±1℃
SALT(Std) Displayed value ±0.05% (for salt concentration of 0.00 to 0.99%)
Relative precision ±5% (for salt concentration of 1.00 to 9.99%)
Relative precision ±10% (for salt concentration of 10.00 to 15.00%)
Measurement time Approx. 3 seconds
Backlight The backlight stays on for 30 seconds after any button is pressed.
Output
NFC Forum Type 4 Tag ISO/IEC 14443 Type A
Output category Date Time, Brix[%],Salt[g/100g], Low Sodium Index, Temp[degC]
(e.g.) 2021/01/17 09:30:45, 76.1,3.71,0.05,21.3
Automatic temperature compensation range 10 to 100℃
Ambient temperature range 10 to 40℃
International Protection class IP65
Power supply Two (2) AAA alkaline batteries
Dimensions and Weight 55(W)×31(D)×109(H)mm , 100g (main unit only)
Press the
渦Key and
水Key for more
than 2 seconds
A0135897
667937E581
LLL
12.5
3.2
AAA
OOO
38.5
39.2
2021/01/17 09:30:45
2021/01/17 09:31:50
2021/01/17 09:32:12
2021/01/17 09:34:26
2021/01/17 09:43:07
2021/01/17 09:43:18
2021/01/17 09:45:39
2021/01/17 09:46:07
LLL
0.31
1.25
AAA
OOO
5.89
5.92
LLL
0.39
0.39
0.15
0.15
20.4
20.5
21.0
21.2
22.3
22.5
25.1
25.3