INSPECTION, STORAGE & TROUBLESHOOTING
InspectionΎ
xVisual inspecƟon shall be made before each use of the device by checking for abnormal
condiƟons, suchas cracked welds, leaks, and damaged, loose, or missing parts.
xOther inspecƟons shall be made per product operaƟng instrucƟons.
xThis device shall be inspected immediately if the device is believed to have been
subjected to an abnormal load or shock. It is recommended that this inspecƟon be made
by a manufacturer’s or supplier’s authorizedrepair facility.
xOwners and/or operators should be awarethat repair of this equipment may require
specialized knowledge and faciliƟes. It is recommended that an annual inspecƟon of the
product be made by a manufacturer’s or supplier’s authorized repair facility and that
any defecƟve parts, decals, or safetylabels or signs be replaced with manufacturer’s or
supplier’s speciĮed parts.
StorageΎ
ΎThis Jack should be stored in a dry locaƟon on a level surface.
Ύ
5
–ATD 7331AModel:
Capacity:3Ton
Troubleshooting
Symptom Possible Causes SoluƟon
Jack will not liŌthe load. 1. Release valve not Ɵghtly
closed.
2. Low oil level.
3. DefecƟve or worn internal
parts.
4. Load exceeds maximum
allowance.
1. Tighten release valve.
2. Check and add oil. Follow“Check
and ReĮll Oil” instrucƟons on Pg.4.
3. DisconƟnue use and contact a
local repair center.
4. Use a higher capacity jack.
Jack will not hold the load. 1. Release valve not Ɵghtly
closed.
2. Power unit malfuncƟon.
1. Tighten release valve.
2. DisconƟnue use and contact a
local repair center.
Jack will not descend to
minimum height, or will not
remain in lowered posiƟon.
1. Air trapped in system.
2. Reservoir oil overĮlled. 1. Vent air out of system. Follow “Air
VenƟng Procedures” above.
2. Check and ensure proper oil level.
Follow “Check and ReĮll Oil”
instrucƟon on Pg.4.
Jack will not liŌto max
height. 1. Low oil level. 1. Check and ensure proper oil level.
Follow “Check and ReĮll Oil”
instrucƟons on Pg. 4.
Jack will not funcƟon
properly aŌer tried soluƟon. 1. Internal malfuncƟon or
structural damage. 1. Stop usage and contact an
authorized repair center.