BASIC LINE Cold Buffet OPERATING INSTRUCTIONS
Location
The unit may only be installed/operated in a well-ventilated environment.
Never operate the unit next to equipment which emits large amounts of steam, such as a dish-
washer. Steam can cause moisture condensation on the unit.
When the unit is connected to the power, there is a danger of the moisture film causing a mal-
function, a short-circuit or an electric shock.
Do not obstruct the section below the refrigeration unit compartment or the ventilation slits.
Insufficient air supply can reduce refrigeration unit efficiency.
The refrigerant propane (R290) is highly flammable and explosive (refrigerant group A3 according
to DIN EN 378-2). In the event of a leak, an ignitable gas-air mixture can be produced which can
trigger an explosive reaction if the critical mixing ratio is reached and there is a suitable source of
ignition source!
Commissioning after storage
Moisture contained in the room air condenses on the surface and the inside of the unit when
the unit is brought from a cold storage room and into a warmer room with a higher level of
humidity. There is a risk of the moisture film causing a malfunction, a short-circuit or an electric
shock when the unit is connected to the power. Do not operate the unit until it has reached
room temperature.
Mains connection
The mains voltage and frequency specified on the rating plate must match the corresponding
values for the mains socket outlet. Only connect the unit to a socket outlet that is protected by
a residual-current device (RCD)/residual-current circuit breaker (each phase with max. 16A).
The unit must not be used if the insulation on the mains cable or the mains plug is damaged.
Insert and remove mains plug only while unit is switched off since, otherwise, the unit electrical
system can be damaged. Connected external devices must also be switched off before
disconnecting the mains plug. Only unplug by pulling on the mains plug housing.
If the unit needs to be connected to the power supply with a fixed electrical connection on site,
the on-site installation must be equipped with a disconnection device acting on all poles which
is accessible at all times and can be secured to ensure it is not switched on accidentally.
General information
The user must be aware of the hazards that the unit presents and be able to assess them.
The unit may only be used by persons whose physical, sensory or mental abilities are not
subject to any restrictions relevant to operating the unit.
The unit may only be used when it is in proper working order.
Only have authorised, expert professionals trained to handle propane refrigerants (R290)
carry out work on the refrigeration system.
Commissioning
Handling and operation