BC BATTERY X-PRO 130 User manual

BC X-PRO 130 –USER MANUAL
Thank you for purchasing the new professional battery charger and power supply unit BC X-PRO 130.
Please read carefully this manual, which provides the operating instructions for the product and indicates
all precautions and warnings to be observed for your safety. Keep the manual with care for future
reference, and follow all instructions before and during use of the device.
FEATURES
BC X-PRO 130 is a professional battery charger and power supply unit with automatic multi-cycle charging
technology. Developed to ensure a stable voltage on 12V vehicles during diagnosis operations and flash
programming, it also allows to recover, recharge and maintain all 12V batteries.
Its compact size and reduced height (10 cm) make it ideal for powering vehicles on display in showrooms,
allowing it to be easily positioned under any car.
The device is supplied with 3 meter long battery connection cables with insulated terminals.
BC X-PRO 130 has 4 different modes/programs to choose from:
• Battery Charger: for the recovery, charging and maintenance of all starting batteries (traditional, sealed,
gel, AGM/EFB Start&Stop, Calcium-Calcium and lithium). It is possible to select the battery type, the
charging current, the maximum Ah to recharge and the maximum charging time. Range of use:
-12V batteries from 1 Ah to 1300 Ah (current min-max: 1 Amp - 130 Amp)
BC X-PRO 130 can also be used for the partial charging of lithium batteries (25%, 50%, 75%, 100%): in fact,
lithium batteries must be stored at a charging percentage around 25%, according to the regulations in force
in the European Union (see the manufacturer's instructions in this regard).
• Power Supply / Voltage Stabilization: this program allows to keep a stable voltage during diagnosis
operations and flash programming on the vehicle, compensating for the energy absorption of the on-board
devices (fan, electronic suspension, electric windows...). It is possible to select the output voltage of the
device in the range from 12.8V to 14.8V as well as the maximum supplied current.
• Memory Saver for Battery Replacement: selecting the Power Supply mode and the output voltage of
12.8V, it is possible to safeguard the vehicle’s memories during battery replacement.
• Showroom: the showroom mode allows an automatic restart of the device whenever it is turned back on.
It can be activated in both the following modes:
-Power Supply: it allows to power the vehicles on display, compensating for the current absorbed
by the on-board instruments (headlights, on-board computer, electric windows, heating...) that are
normally used or turned on in showrooms for vehicle demonstrations. When the Showroom mode
is active, in the event of a power failure, BC X-PRO 130 restarts automatically when the electricity is
restored, allowing it to be left connected with no need for intervention by showroom personnel.
-Battery Charger:when the showroom mode is active, in the event of a power failure, BC X-PRO 130
restarts automatically when the electricity is restored, starting to charge the battery again. The
device also keeps in memory the Ah provided to the battery: when the device is turned back on, it
resumes counting Ah starting from the value reached at the last shutdown.
SAFETY AND WARNINGS
This device has to be used according to the working conditions it has been designed for within the limits
indicated in this manual. Any other use is to be considered either dangerous or improper. Please strictly
comply with all safety instructions. The manufacturer is completely exonerated from whatever
responsibility for possible damages due to either wrong, unreasonable or improper use of the device.

The device is suitable for indoor use. Do not use the device outdoor and do not expose the device
to the atmospheric agents (rain, water, saltiness...).
The device is not intended for use by children or persons with reduced physical, mental or sensory
capabilities, or lack of enough experience and knowledge to understand the instructions on this
manual, except in the presence of a responsible person who can ensure the safe use of the device.
Keep out of reach of children and ensure that they cannot play with it.
Do not use the device to charge NiCd, NiMH or non-rechargeable batteries.
Please verify that the input and output cables are in good conditions before using the device. If the
input cable is damaged, do not use the device: ask the manufacturer or an authorized service agent
for repair or replacement. Do not connect the device to a damaged power outlet.
Do not try to recharge a frozen or damaged battery.
Do not cover the device during use.
Do not place the device close to heat sources. Do not use in environments with temperatures
above 50°C. In Power Supply mode, the device is designed to work at maximum power with
ambient temperatures up to 30°C.
The operating mode of the device and the restrictions applicable to its use are explained in the
following sections of this manual.
During the charging, a battery might produce explosive gases: avoid generating flames or sparks in
its proximity and place the battery in a well ventilated area, to avoid any risk of fire or explosion.
Protect the battery surface from any risk of short circuits.
Batteries contain a corrosive electrolyte. Wear protective goggles and gloves when operating in
proximity of the battery. In case the acid gets in touch with your skin or eyes, rinse them
immediately with plenty of water and ask for a doctor.
CONNECTION OF BC X-PRO 130
Before connecting/disconnecting the device to/from the battery, turn off the switch and disconnect
the device from the power outlet.
Connect first the battery terminal not connected to the chassis (usually the positive one, red clamp
to the positive + pole of the battery), then connect the other clamp to the chassis, far from the
battery, the fuel line and the tank. Then, connect the device to the power outlet and turn on the
switch.
After using the device, turn off the switch and disconnect the device from the power outlet first,
then disconnect the clamp connected to the chassis, then disconnect the clamp connected to the
battery, in this order.
WARNING: The charger must be connected to an earthed power outlet. The connection to the
power outlet must be carried out in compliance with national standards.
START UP OF BC X-PRO 130
1. Connect the device to the power outlet.
2. Turn on the device, placing the switch on “I”. The digital display turns on, showing «BC X-PRO - fw
x.x»
3. The charger is set to the last configuration used. To change the operating mode (Battery Charging,
Power Supply...), the parameters (battery type, current, voltage...) or the language, follow the
instructions in the next paragraphs.

SELECTION MENU
BC X-PRO 130 is provided with a push-button panel that allows to select the operating mode, the related
parameters and the display language.
To enter the selection menu, keep pushed the “ON/OFF - SELECT” button for 5 seconds.
NB: every time you turn on BC X-PRO, it is necessary to wait for the initialization to be complete before
entering the menu.
Menu items:
Mode: it allows to choose the operating mode between Battery Charger and Power Supply.
Safety: it allows to set up several safety parameters for battery charging (battery test, maximum
Ah, maximum charging time)
Language: it allows to select the display language.
Showroom: Showroom: it allows to set the automatic restart in both Battery Charger and Power
Supply modes (exception for Power Supply mode with 12.8V output voltage selected).
To move between the menu and submenu items, use the arrow keys and confirm the choices with the
“ON/OFF - SELECT” button. If no key is pressed for 40”, the device automatically exits the selection mode
and restarts with the previous configuration. It is possible to exit the menu at any time without confirming
the choices, keeping the “ON/OFF - SELECT” button pressed for 5 seconds.
LANGUAGE SELECTION
You can select the display language of the BC X-PRO 130 from 6
different languages. Proceed as follows:
1. Press and hold the “ON/OFF - SELECT” button for 5 seconds
to access the menu.
2. Press the arrow keys until you reach Menu: Language. Press
“ON/OFF - SELECT” to confirm.
3. Select the desired language with the arrow keys: ENGLISH
–ITALIANO –PORTUGAL –ESPANOL –DEUTSCH –
FRANCAIS
4. Press the “ON/OFF - SELECT” button to confirm the
selection.
OPERATING MODE –BATTERY CHARGER
In Battery Charger mode, BC X-PRO 130 is equipped with
different charging algorithms for different types of 12V starting
batteries. Before connecting the device to the battery, make
sure to correctly select the battery type and the maximum
charging current, depending on the battery to be recharged
(follow the instructions in the following paragraph).
The following battery types can be selected:
STD/MF: it executes an automatic multi-cycle charging
algorithm suitable for the recovery, charging, desulfation
and maintenance of all lead-acid traditional (with liquid
electrolyte) and sealed starting batteries (maintenance-
free and gel batteries). If it is necessary to recharge a
traditional battery, check the electrolyte level and fill up to the level recommended by the battery
manufacturer, if necessary.
WARNING
When using the BATTERY CHARGER
mode, select a maximum charging
current equal to one tenth of the
battery capacity in Ah or to the
value immediately higher in the
scale of the selectable values - ex:
for a battery with a capacity of 80
Ah, maximum current 10.0 A
(except lithium batteries).

AGM/EFB: perfect charging algorithm for batteries installed on vehicles equipped with Start & Stop
systems, which require a different charging curve with higher voltages.
Ca/Ca: select this type to recharge calcium-calcium or lead-calcium batteries.
Litio: specific charging algorithm for the new generation of lithium-ion or lithium-iron-phosphate
starting batteries. It is possible to execute a partial charge for lithium batteries by selecting the
charging percentage to be reached: 25%, 50%, 75%, 100%. In fact, it is advisable to keep lithium
batteries in stock / on shelf at a charging percentage around 25/50% (see manufacturer's
instructions), to increase their life span
CHARGING MODE & PARAMETERS SELECTION
Before connecting the device to the battery, select the
"CHARGER" operating mode and set the charging
parameters as follows:
1. Press and hold the “ON/OFF - SELECT” button for 5
seconds to access the menu.
2. Press the arrow keys until you reach Menu: MODE.
Press “ON/OFF - SELECT” to confirm.
3. Select the operating mode CHARGER with the
arrow keys. Press the "ON/OFF - SELECT” button to
confirm the choice.
4. Select the battery type with the arrow keys:
STD/MF –Lithium –AGM/EFB –Ca/Ca. Press the
"ON/OFF - SELECT” button to confirm the choice.
5. Select the maximum charging current with the
arrow keys. Note: select a maximum charging
current equal to a tenth of the battery capacity, or
to the value immediately higher in the scale of
selectable values (ex: for a battery with a capacity
of 80 Ah, maximum current 10.0 A). When
charging lithium batteries, it is possible to select a
higher maximum charging current, but a slow
charge is recommended anyway. Comply with the
battery manufacturer's instructions and instructions
for the maximum recommended charging current.
Press the "ON/OFF - SELECT” button to confirm the
choice.
6. Only for Lithium batteries: select the charging
percentage to be reached (25%, 50%, 75%, 100%).
Press the "ON/OFF - SELECT” button to confirm the
choice.
7. For all other batteries: select Desulph. ON/OFF to
enable or disable the desulphation cycle. It is
recommended to set this parameter as ON for used
batteries, OFF for new batteries. Press the "ON/OFF
- SELECT” button to confirm the choice.
The display shows “OK”. BC X-PRO 130 restarts and
shows all parameters set in the “Mode” and “Safety”
menus. After the initialization is complete, the first row of the LCD display always shows the chosen
parameters. The second row shows: “Load not connected!”.

SELECTION OF SAFETY PARAMETERS FOR CHARGING
It is possible to select several customized additional
settings for the Battery Charger operating mode by
following the procedure below:
1. Press and hold the “ON/OFF - SELECT” button for 5
seconds to access the menu.
2. Press the arrow keys until you reach Menu: SAFETY.
Press “ON/OFF - SELECT” to confirm.
3. Select Battery Test ON/OFF to choose whether to
execute the battery cells check at the end of the
Recovery, Soft Charge and Bulk Charge cycles. Press
the "ON/OFF - SELECT” button to confirm the
choice.
4. Set the maximum Ah value to supply to the battery
(optional), from 1 to 999 Ah. Hold the arrow key
pushed to increase/decrease quickly the value. The
standard setting of the device does not provide for
a maximum limit of Ah. To disable the limit, press
the arrow button ↓ until you reach OFF. Press the
"ON/OFF - SELECT” button to confirm the choice.
5. Set the maximum time for battery charging
(optional), from 1 to 999 ore (h). Hold the arrow key
pushed to increase/decrease quickly the value. The
standard setting of the device does not provide for
a maximum charging time. To disable the limit,
press the arrow button ↓ until you reach OFF. Press
the "ON/OFF - SELECT” button to confirm the
choice.
The safety parameters set in this way are saved in
memory for subsequent uses.
START / STOP THE CHARGE:
Once the desired charging parameters have been selected, connect BC X-PRO 130 to the battery to be
recharged (red terminal: positive pole - black terminal: negative pole), following the instructions reported
in the paragraph: “Connection of BC X-PRO 130” and press the “ON/OFF - SELECT” button to start charging.
At any time, it is possible to stop and restart the charging procedure by pressing the “ON/OFF - SELECT”
button.
During charging, the display shows the following indications:
Row 1: the selected charging parameters (battery type and maximum current)
Row 2: SHOWROOM Mode ON/OFF
Row 3: the current supplied by the battery charger and the battery voltage (state of charge)
Riga 4: the ampere-hours delivered to the battery and the time elapsed since the beginning of the
charging process
The display also shows any error or anomaly (load not connected, polarity inversion or short circuit, mains
not connected...).
Once charging is complete, the charger automatically keeps the battery at an optimal voltage. It is
recommended to reduce the vehicle's absorption to a minimum, turning off any superfluous loads during
charging.

11 CYCLES CHARGING ALGORITHM –LEAD-ACID BATTERIES (STD/MF/AGM/EFB/CA-CA):
Step 1 - Initial Battery Check: it verifies that one or more battery cells are not short-circuited and therefore
the battery is a proper condition to be recharged / recovered.
Step 2 - Recovery: if the battery is extremely discharged (starting from 1.25V), the device tries to recover it,
in order to bring it to a higher voltage compatible with the following step.
Step 3 –Battery and Cells Short Circuit Check: it checks that the battery cells are not short-circuited before
switching to the following step. To skip this test, select “Bat.Test OFF” in the Safety menu.
Step 4 - Soft Charge: if the battery is significantly undercharged, the device provides a light pulsing current
to the battery, in order to overcome this critical phase.
Step 5 - Battery and Cells Short Circuit Check: it checks that the battery cells are not short-circuited before
switching to the following step. To skip this test, select “Bat.Test OFF” in the Safety menu.
Step 6 - Bulk Charge: during this cycle the battery charger provides full current to the battery, which can
recover in this step up to 85-90% of its capacity.
Step 7 - Battery and Cells Short Circuit Check: it checks that the battery cells are not short-circuited before
switching to the following step. To skip this test, select “Bat.Test OFF” in the Safety menu.
Step 8 - Desulphation / Absorption: in this step the device provides the battery with a “controlled
overcharge” in order to restore the remaining 10-15% of the battery capacity, through the desulphation /
recovery of the lead-acid cells (for mild or medium sulphation levels). It is possible to skip this charging
cycle by setting “Desulphation OFF” in the menu Mode -> Charger.
Step 9 - Battery Check at End of the Charging Cycle: the device stops providing current for a few tens of
minutes and verifies that the battery is able to retain the charge received during the previous charging
cycles. The test is periodically repeated at regular intervals during maintenance.
Step 10 - Maintenance: thanks to a specially designed electronic circuit, the device maintains the battery
fully charged during periods of inactivity, sen without any overheating, overcharging or electrolyte loss.
Step 11 - Equalization: during long term maintenance, the device executes an equalization process each 30
days to re-balance the battery cells, avoiding the electrolyte stratification.
10 CYCLES CHARGING ALGORITHM –LITHIUM BATTERIES:
Step 1 - Initial Battery Check: it verifies that the battery is a proper condition to be recharged / recovered.
Step 2 - Recovery: if the battery is extremely discharged, the device tries to recover it, in order to bring it to
a higher voltage compatible with the following step.
Step 3 - Battery and Cells Short Circuit Check: it checks that the battery cells are not short-circuited before
switching to the following step. To skip this test, select “Bat.Test OFF” in the Safety menu.
Step 4 - Soft Charge: if the battery is significantly undercharged, the device provides a light pulsing current
to the battery, in order to overcome this critical phase.
Step 5 - Battery and Cells Short Circuit Check: it checks that the battery cells are not short-circuited before
switching to the following step. To skip this test, select “Bat.Test OFF” in the Safety menu.
Step 6 - Bulk Charge: during this cycle the battery charger provides full current to the battery, which can
recover in this step up to 85-90% of its capacity.
Step 7 - Battery and Cells Short Circuit Check: it checks that the battery cells are not short-circuited before
switching to the following step. To skip this test, select “Bat.Test OFF” in the Safety menu.
Step 8 - Equalization: the device recovers the remaining 10-15% of the battery capacity, and re-balances
the state of charge of the different battery cells.
Step 9 - Battery Check at End of the Charging Cycle: the device stops providing current for a few tens of
minutes and verifies that the battery is able to retain the charge received during the previous charging
cycles. The test is periodically repeated at regular intervals during maintenance.
Step 10 - Maintenance: thanks to a specially designed electronic circuit, the device maintains the battery
fully charged during periods of inactivity, sen without any overheating or overcharging.

OPERATING MODE –POWER SUPPLY / VOLTAGE STABILIZATION
The power supply mode allows maintaining a stable voltage during diagnostics and programming
operations on the vehicle. Before connecting BC X-PRO 130 to the vehicle, please select the voltage to keep
according to the indications in the following paragraph.
POWER SUPPLY MODE & PARAMETERS SELECTION
To select the “POWER SUPPLY” mode of BC X-PRO 130,
please proceed as follows:
1. Press and hold the “ON/OFF - SELECT” button for 5
seconds to access the menu.
2. Press the arrow keys until you reach Menu: MODE.
Press “ON/OFF - SELECT” to confirm.
3. Select the operating mode SUPPLY with the arrow
keys. Press the “ON/OFF - SELECT” button to
confirm the choice.
4. Select the voltage to stabilize with the arrow keys:
12,8V -> 13,6V -> 13,8V -> 14,0V -> 14,4V -> 14,8V
Please refer to the vehicle manufacturer’s
instructions for the voltage level to keep during
diagnostics operations. Press the “ON/OFF -
SELECT” button to confirm the choice.
5. Select the maximum power supply current with the
arrow keys, between 1 A and 130 A. Press the
“ON/OFF - SELECT” button to confirm the choice.
The display indicates “OK”. BC X-PRO 130 restarts and
the first row of the display shows the chosen
parameters. The second row shows: “Load not
connected!”.
START / STOP THE POWER SUPPLY:
Once the desired power supply parameters have been selected, connect BC X-PRO 130 to the vehicle (red
clamp: positive pole –black clamp: negative pole), following the instructions in the paragraph: “Connection
of BC X-PRO 130”.
At any time, it is possible to stop and restart the charging procedure by pressing “ON/OFF - SELECT” button.
During the power supply operation, the display shows the following indications:
Row 1: the selected power supply parameters (voltage)
Row 2: SHOWROOM mode ON/OFF
Row 3: the current supplied by the unit and the voltage on the vehicle
Row 4: power supply active (ON) or paused (OFF)
Moreover, the display shows any working anomaly or error (load not connected, mains not
connected…).
PLEASE NOTE: do not allow the positive and negative clamps of the device to touch and do not connect to
the vehicle with reversed polarity! A polarity inversion could damage the vehicle’s electronics.

OPERATING MODE –SHOWROOM
The “Showroom” function can be activated both in “Power Supply”mode and in “Battery Charger”mode:
In Power Supply mode, as soon as the device is turned on or the current is restored, it checks
whether there is a connection to the battery. If this check detects a connected battery, BC X-PRO
130 automatically starts the power supply, keeping the battery voltage at the set value.
In Battery Charger mode, as soon as the device is turned on or the current is restored, it checks
whether there is a connection to the battery. If this check detects a connected battery, BC X-PRO
130 automatically starts recharging the battery, restarting from the situation reached (Ah provided
to the battery and elapsed time) before the mains supply was interrupted.
Example of use: the charging of a 120 Ah battery in a workshop is interrupted after charging 50 Ah in 5h10’,
to switch off the mains supply at the end of the day. When the power is restored the following morning, BC
X-PRO 130 will resume charging from the point reached, showing on the display the same data (Ah and
charging time) that were indicated at the time of interruption.
To select the “SHOWROOM” mode of BC X-PRO 130, please proceed as follows:
1. Press and hold the “ON/OFF - SELECT” button for 5
seconds to access the menu.
2. Press the arrow keys until you reach Menu:
SHOWROOM. Press “ON/OFF - SELECT” to confirm.
3. To activate the SHOWROOM mode, select ON with
the arrow keys. Press the “ON/OFF - SELECT” button
to confirm the choice.
The display indicates “OK”. BC X-PRO 130 restarts with
the last used configuration, and with SHOWROOM
mode active. In the event of a power failure (for
example, when the power is turned off in the
showroom in the evening), the device is now ready to
restart as soon as the power is restored.
When BC X-PRO 130 is connected to a battery in
BATTERY CHARGER mode or to a vehicle in POWER
SUPPLY mode, the second row always shows whether
the SHOWROOM mode is enabled (ON) or disabled
(OFF).
WARNING: it is necessary to set the desired charging or
power supply parameters before connecting the device
to the battery or vehicle. Proceed according to the
instructions in the previous sections of this manual. The SHOWROOM mode cannot be enabled when the
device is set in POWER SUPPLY mode with a voltage of 12.8V (Memory Saver Mode).
OPERATING MODE –MEMORY SAVER FOR BATTERY REPLACEMENT
To use BC X-PRO 130 as a memory saver while replacing a vehicle’s battery, please proceed as follows:
1. Press and hold the “ON/OFF - SELECT” button for 5 seconds to access the menu.
2. Press the arrow keys until you reach Menu: MODE. Press “ON/OFF - SELECT” to confirm.
3. Select the operating mode SUPPLY with the arrow keys.
4. Press the “ON/OFF - SELECT” button to confirm the choice.
5. Select the voltage to stabilize with the arrow keys: 12.8V.
6. Press the “ON/OFF - SELECT” button to confirm the choice.
7. Select the maximum power supply current with the arrow keys, between 1 A and 130 A.
8. Press the “ON/OFF - SELECT” button to confirm the choice.
The display indicates “OK”. BC X-PRO 130 restarts and the first row of the display shows the chosen
parameters. The second row shows: “Load not connected!”.

Connect BC X-PRO 130 to the vehicle to be powered, making sure to firmly connect the red terminal to the
end of the eyelet connector connected to the positive pole of the battery and the black terminal to the
chassis (or to the end of the eyelet connector connected to the negative pole of the battery).
Make sure the connection is stable and secure and that the power supply status is "ON" before
disconnecting the battery from the vehicle, to avoid data loss. Proceed replacing the battery with correct
polarity and making sure that the terminals of BC X-PRO 130 do not disconnect from the vehicle.
Once the new battery is installed, press the "ON/OFF - SELECT" button to stop providing the power supply
and then disconnect the terminals from the vehicle.
PROTECTIONS
BC X-PRO 130 is able to provide the operator with the following set of active protections during installation
and use, while working in Battery Charger mode:
1. Protection against battery poles inversion.
2. Protection against short circuit (even for an indefinite time): no sparks!
3. Protection against overheating: the supplied current is automatically limited in case of excessive heating
of the device.
It is recommended to pay particular attention when connecting to a vehicle in Power Supply mode: a
polarity inversion or a short circuit could generate sparks and damage the vehicle's electronics.
BC X-PRO 130 is provided with an internal protection fuse against connection mistakes by the user.
.
MAINTENANCE
If the power cable is damaged, do not use the product but ask for replacement or repair by the
manufacturer or by an authorized service center.
Before executing any cleaning/maintenance operation on the device, please check the device is not
connected to the power outlet.
The battery charger is designed not to require any maintenance: please remove possible dust
which may get accumulated on the cover of the device using a delicate detergent to avoid
damaging the stickers. In case the device does not work properly, do not attempt to repair it;
please ask either your local dealer or the equipment manufacturer (info@batterycontroller.it) for
support. Any attempt to open unduly the device shall cause the withdrawal of the warranty.
If the internal fuse is damaged, please ask the device manufacturer or an authorized service center
for replacement.
DISPOSAL OF THE DEVICE
The device must be disposed of in accordance with the WEEE regulation for the disposal of Waste Electrical
and Electronic Equipment. Do not dispose of it with normal household waste.
DECLARATION OF CONFORMITY
The device is manufactured in compliance with current safety regulations and European Directives.
Forelettronica Srl declares under its own responsibility that the BC X-PRO device complies with the
following standards. Reference standards: 60335-1, 60335-2-29, 55014-1, 55014-2, 61000-3-2, 61000-3-3,
62233, 50581.
The device is CE marked. The declaration of conformity can be downloaded from our website.

TROUBLESHOOTING –BATTERY CHARGER OPERATING MODE
ANOMALIE CAUSE RIMEDI
1. The display shows the error message: “Load not connected”
No battery is connected to the device -> Check battery connection
2. The display shows the error message: “Short/Pol. Inverted”
Battery connected with reverse polarity -> Connect the red terminal to the battery positive pole (+)
and the black terminal to the battery negative pole (-)
Short circuited battery -> Replace battery
Short circuit on the output of BC X-PRO 130 -> Please ask the manufacturer or an authorized service
center for support
3. The display shows the error message: “Mains not connected”
BC XPRO 130 not connected to power supply -> Connect the device to the mains and turn it on by
putting the switcher in “I” position.
4. The display shows the error message: “Weak battery”
The Battery Check step detected that the battery is not able to retain the charge -> Replace the
battery
5. The display shows the error message: “Psu internal error”
Internal problem inside BC X-PRO 130 -> Please ask the manufacturer or an authorized service
center for support

TROUBLESHOOTING –POWER SUPPLY OPERATING MODE
ANOALIE CAUSE RIMEDI
1. The display shows the error message: “Load not connected”
No load is connected to the device -> Check the connection of BC X-PRO 130 to the vehicle
2. The display shows the error message: “Short/Pol. Inverted”
BC X-PRO 130 connected with reverse polarity -> Connect the red terminal to the positive pole (+)
and the black terminal to the negative pole (-)
Short circuit on the output of BC X-PRO 130 -> Please ask the manufacturer or an authorized service
center for support
3. The display shows the error message: “Mains not connected”
BC XPRO 130 not connected to power supply -> Connect the device to the mains and turn it on by
putting the switcher in “I” position.
4. The display shows the error message: “Supply overload”
The loads connected require too much current, BC X-PRO 130 cannot keep the set voltage -> Switch
off or disconnect some loads.
5. The display shows the indication: “Correct Polarity?”
When BC X-PRO 130 is connected to the vehicle in Power Supply operating mode and the detected
voltage is below a predetermined threshold, the display asks the user to check that the polarity is
correct before starting the power supply -> Please check that the red clamp is connected to the
positive pole (+) and the black clamp to the negative pole (-). Then, press the button “ON/OFF -
SELECT” to start the power supply.
WARNING: starting the power supply with reversed polarity could cause serious damage to the
electrical and electronic parts of the vehicle!

6. The display shows the error message: “Overtemperature”
Overheating of BC X-PRO 130, the power supply is suspended -> Please check that the device is
positioned in a ventilated environment, away from the sun or other heat sources, and that the air
vent is not covered.
WARNING: BC X-PRO 130 is designed to work at maximum power with a maximum ambient
temperature up to 30°C.
7. The display shows the error message: “Psu internal error”
Internal problem inside BC X-PRO 130 -> Please ask the manufacturer or an authorized service
center for support
TECHNICAL DATA
Input Voltage 100-240V ac, 50/60Hz
Charging Voltage 13.8V-14.7V –nom. 12V
Charging Current (Battery Charger Mode) selectable from 1A to 130A
Battery Types 12V lead (traditional, MF, gel, AGM, EFB), Ca/Ca and lithium
Battery Capacity from 1.2 to 1300 Ah
Charging Algorithm 11 cycles (lead & Ca/Ca), 10 cycles (lithium)
Power Supply Voltage selectable from 12.8V to 14.8V
Cable Section 25 mm2
Cable Length 3 meters
Dimensions (L x l x H) –Handle excluded 37 x 24 x 10 cm
Dimensions (L x l x H) –Handle included 37 x 29 x 10 cm
Weight 4.6 Kg
Table of contents