BC Biomedical DA-2006 User manual

DEFIBRILLATOR
ANALYZERS
DA-2006
DA-2006P
W/ PACER
ANALYZER
SERVICE MANUAL

i
WARNINGS, CAUTIONS, NOTICES ...............................................................................ii
MANUAL REVISIONS.....................................................................................................iv
WARRANTY....................................................................................................................iv
MANUALS
DA-2006 Series User Manual (Rev 06) ............................................. SECTION A
DA-CS-06 (Rev 02) ........................................................................... SECTION A
OPERATIONAL THEORY.............................................................................. SECTION B
VALIDATION / CALIBRATION .......................................................................SECTION C
PARTS ...........................................................................................................SECTION D
BC BIOMEDICAL
SERVICE MANUAL
DA-2006 SERIES
TABLE OF CONTENTS
This Service Manual covers the following units:
• DA-2006
• DA-2006P

ii
WARNING - MODIFICATIONS
The DA-2006 Series Analyzers are intended for
use within the published specifications. Any
application beyond these specifications or any
unauthorized user modifications may result in
hazards or improper operation.
CAUTION - SERVICE
The DA-2006 Series Analyzers are intended to be
serviced only by authorized service personnel.
Troubleshooting and service procedures
should only be performed by
qualified technical personnel.

iii
Service Manual DA-2006 Series Copyright © 2007
www.bcgroupintl.com Made in the USA
5/07 Rev02
NOTICE – DISCLAIMER
BC GROUP INTERNATIONAL, INC. RESERVES THE RIGHT TO
MAKE CHANGES TO ITS PRODUCTS OR SPECIFICATIONS AT
ANY TIME, WITHOUT NOTICE, IN ORDER TO IMPROVE THE
DESIGN OR PERFORMANCE AND TO SUPPLY THE BEST
POSSIBLE PRODUCT. THE INFORMATION IN THIS MANUAL HAS
BEEN CAREFULLY CHECKED AND IS BELIEVED TO BE
ACCURATE. HOWEVER, NO RESPONSIBILITY
IS ASSUMED FOR INACCURACIES.
NOTICE – CONTACT INFORMATION
BC BIOMEDICAL
BC GROUP INTERNATIONAL, INC.
PO BOX 25125
9415 GENTRY AVE
ST. LOUIS, MO 63125
USA
1-800-242-8428
314-638-3800
www.bcgroupintl.com
NOTICE – DISCLAIMER
USER ASSUMES FULL RESPONSIBILITY FOR UNAUTHORIZED
EQUIPMENT MODIFICATIONS OR APPLICATION OF EQUIPMENT
OUTSIDE OF THE PUBLISHED INTENDED USE AND
SPECIFICATIONS. SUCH MODIFICATIONS OR APPLICATIONS
MAY RESULT IN EQUIPMENT DAMAGE OR PERSONAL INJURY.

iv
Revision # Engineering # Revisions Made
Rev 01 7395 Origination
Rev 02 395 Drawing scans inserted
P:\Manuals\BCGroup\…\DA-2006_Series_SM_Rev02.doc
LIMITED WARRANTY
WARRANTY
: BC GROUP INTERNATIONAL, INC. WARRANTS ITS NEW PRODUCTS TO BE FREE
FROM DEFECTS IN MATERIALS AND WORKMANSHIP UNDER THE SERVICE FOR WHICH THEY
A
RE INTENDED. THIS WARRANTY IS EFFECTIVE FOR TWELVE MONTHS FROM THE DATE OF
SHIPMENT.
EXCLUSIONS: THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE.
BC GROUP INTERNATIONAL, INC. IS NOT LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES.
NO PERSON OTHER THAN AN OFFICER IS AUTHORIZED TO GIVE ANY OTHER WARRANTY OR
A
SSUME ANY LIABILITY.
REMEDIES: THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY SHALL BE: (1) THE REPAIR OR
REPLACEMENT OF DEFECTIVE PARTS OR PRODUCTS, WITHOUT CHARGE. (2) AT THE OPTION
OF BC GROUP INTERNATIONAL, INC., THE REFUND OF THE PURCHASE PRICE.
MANUAL REVISIONS

SECTION A
USER MANUAL
DA-2006 SERIES
REV 06

DEFIBRILLATOR
ANALYZERS
DA-2006
DA-2006P
W/ PACER
ANALYZER
USER MANUAL

1
WARNINGS, CAUTIONS, NOTICES ........................................................................... 2
DESCRIPTION............................................................................................................. 7
OVERVIEW.................................................................................................................. 15
DEFIBRILLATOR ANALYZER ..................................................................................... 23
MAIN SCREEN.................................................................................................. 23
ECG WAVEFORMS SCREEN .......................................................................... 31
PLAYBACK LAST PULSE SCREEN ................................................................. 35
START CHARGE TIMER SCREEN .................................................................. 37
PRINT HEADER................................................................................................ 39
SELF TEST WAVEFORM ................................................................................. 41
RUNNING A DEFIBRILLATION TEST .............................................................. 43
INTRODUCTION .................................................................................... 43
DEFIBRILLATION TEST......................................................................... 45
CARDIOVERSION TEST........................................................................ 49
CHARGE TIME TEST............................................................................. 53
SHOCK ADVISORY ALGORITHM TEST ............................................... 55
TRANSCUTANEOUS PACEMAKER ANALYZER ....................................................... 57
PACE MAIN SCREEN ...................................................................................... 57
PACER MODE SETUP SCREEN...................................................................... 63
SENSITIVITY TEST .......................................................................................... 65
REFRACTORY PERIOD TEST ......................................................................... 67
PRINT MENU SCREEN .................................................................................... 69
PLAYBACK LAST PULSE SCREEN ................................................................. 71
BC BIOMEDICAL
DA-2006 SERIES
TABLE OF CONTENTS

DA-2006 Series
2
MESSAGES ................................................................................................................. 73
SYSTEM SETUP.......................................................................................................... 75
POWER UP SETTINGS............................................................................................... 77
AUTO SEQUENCE FUNCTION................................................................................... 79
VIEW MODE ..................................................................................................... 81
RUN MODE ...................................................................................................... 85
PROGRAMMING AUTO SEQUENCES ....................................................................... 95
MANUAL REVISIONS................................................................................................ 107
WARRANTY............................................................................................................... 107
SPECIFICATIONS ..................................................................................................... 109
NOTES....................................................................................................................... 115

DA-2006 Series
3
WARNING - USERS
The DA-2006 Series Analyzers are for use by
skilled technical personnel only.
WARNING - USE
The DA-2006 Series Analyzers are intended for
testing only and they should never be used in
diagnostics, treatment or any other capacity
where they would come in contact with a patient.
WARNING - CONNECTIONS
All connections to patients must be removed
before connecting the Device Under Test (DUT)
to the Analyzer. A serious hazard may occur
if the patient is connected when
testing with the Analyzer.
Do not connect any leads from the patient
directly to the Analyzer or DUT.
WARNING - POWER ADAPTOR
Unplug the Power Adaptor before
cleaning the surface of the Analyzer.
WARNING - LIQUIDS
Do not submerge or spill liquids on the Analyzer.
Do not operate the Analyzer if internal
components not intended for use with fluids may
have been exposed to fluid, as the internal
leakage may have caused corrosion and be a
potential hazard.
WARNING - MODIFICATIONS
The DA-2006 Series Analyzers are intended for
use within the published specifications. Any
application beyond these specifications or any
unauthorized user modifications may result in
hazards or improper operation.

DA-2006 Series
4
CAUTION - SERVICE
The DA-2006 Series Analyzers are intended to be
serviced only by authorized service personnel.
Troubleshooting and service procedures
should only be performed by
qualified technical personnel.
CAUTION - ENVIRONMENT
The DA-2006 Series Analyzers are intended to
function between 15 and 40 °C.
Exposure to temperatures outside this range can
adversely affect the performance of the Analyzer.
CAUTION - CLEANING
Do not immerse. The Analyzer should be
cleaned by wiping gently with a damp, lint-free
cloth.
CAUTION - INSPECTION
The DA-2006 Series Analyzers should be
inspected before each use for wear and
the Analyzer should be serviced
if any parts are in question.
NOTICE – SYMBOLS
Symbol Description
Caution
(Consult Manual for Further Information)
Center Positive
Direct Current

DA-2006 Series
5
NOTICE – ABBREVIATIONS
A, Amps Amperes
BPM Beats Per Minute
c centi- (10
-2
)
C Celsius
° degree
dt Delta Time, Change in Time
DUT Device Under Test
E Energy
ECG Electrocardiogram
Euro European
Hz hertz
J Joules
k kilo- (10
3
)
kg kilograms
lbs pounds
µ micro- (10
-6
)
µA microampere
µH microhertz
µV microvolt
µsec microsecond
m milli- (10
-3
)-
mA milliampere
mm millimeter
ms, mS,
msec millisecond
mV millivolts
Ωohm
P Power
ppm pulse per minute
R Resistance, ohms
Sec, S seconds
US United States
V volt
VDC Direct Current Voltage

DA-2006 Series
6
Manual DA-2006 Series Copyright © 2007
www.bcgroupintl.com Made in the USA
5/07 Rev06
NOTICE – DISCLAIMER
BC GROUP INTERNATIONAL, INC. RESERVES THE RIGHT TO
MAKE CHANGES TO ITS PRODUCTS OR SPECIFICATIONS AT
ANY TIME, WITHOUT NOTICE, IN ORDER TO IMPROVE THE
DESIGN OR PERFORMANCE AND TO SUPPLY THE BEST
POSSIBLE PRODUCT. THE INFORMATION IN THIS MANUAL HAS
BEEN CAREFULLY CHECKED AND IS BELIEVED TO BE
ACCURATE. HOWEVER, NO RESPONSIBILITY
IS ASSUMED FOR INACCURACIES.
NOTICE – CONTACT INFORMATION
BC BIOMEDICAL
BC GROUP INTERNATIONAL, INC.
PO BOX 25125
9415 GENTRY AVE
ST. LOUIS, MO 63125
USA
1-800-242-8428
314-638-3800
www.bcgroupintl.com
NOTICE – DISCLAIMER
USER ASSUMES FULL RESPONSIBILITY FOR UNAUTHORIZED
EQUIPMENT MODIFICATIONS OR APPLICATION OF EQUIPMENT
OUTSIDE OF THE PUBLISHED INTENDED USE AND
SPECIFICATIONS. SUCH MODIFICATIONS OR APPLICATIONS
MAY RESULT IN EQUIPMENT DAMAGE OR PERSONAL INJURY.

7
The Model DA-2006 Series is a microprocessor-based instrument family that is used in the
testing of defibrillators. They measure the energy output and provide information about the
defibrillation pulse. They are used on manual, semi-automatic and automatic defibrillators
with monophasic or biphasic outputs.
The DA-2006P model additionally provides a Transcutaneous Pacemaker analysis function.
It measures and displays pacer pulse information as well as performing Refractory Period,
Sensitivity and Immunity testing.
All models have a built in 50 ohm human body simulation load as well as 12 lead ECG with
arrhythmias and performance waveforms. Additionally, they have a Centronics printer port,
a serial port, oscilloscope output, high-level ECG output, as well as provision for a battery
eliminator.
The DA-2006 Series makes viewing and selecting the desired waveforms and test data
quick and intuitive, with all operational information being available on the 240 by 64 pixel
graphic display, allowing for easy maneuvering through parameters and scrolling through
available options.
NOTE: The instrument is intended for use by trained service technicians.
BC GROUP
DA-2006 SERIES
DEFIBRILLATOR ANALYZER

DA-2006
8
The following are highlights of some of the main features:
GENERAL
• SIMPLE TO OPERATE
• GRAPHICS DISPLAY WITH SIMULTANEOUS DETAILED STATUS OF
PARAMETERS AND SCROLLING CONTROL OF OPTIONS
• ON SCREEN VIEWING OF DEFIBRILLATOR AND PACEMAKER WAVEFORMS
• DROP DOWN CHOICE SCREENS LIST ALL OPTIONS FOR PARAMETERS
• MONOPHASIC AND BIPHASIC COMPATIBLE
• 5000 V, 1000 JOULE CAPACITY
• HIGH AND LOW RANGES
• CARDIOVERSION DELAY MEASUREMENT
• CHARGE TIME MEASUREMENT
• WAVEFORM STORAGE AND PLAYBACK
• 10 UNIVERSAL PATIENT LEAD CONNECTORS
• 25 PIN CONNECTOR FOR CENTRONICS PRINTER
• 9 VOLT BATTERY POWER
• LOW BATTERY INDICATOR
• AVAILABLE BATTERY ELIMINATOR
• DISPLAY BACKLIGHT
• FULL REMOTE OPERATION VIA RS-232
• FLASH PROGRAMMABLE FOR UPGRADES
• AUTO SEQUENCE TESTING CAPABLE OF STORING 50 CUSTOM TEST
SEQUENCES
PACEMAKER OPTION
• 26 SELECTABLE INTERNAL LOADS
• FULL PULSE ANALYSIS
• DEMAND SENSITIVITY TEST
• REFRACTORY PERIOD TESTS
• 50/60 Hz INTERFERENCE TEST SIGNALS
• INPUT TERMINALS AND CIRCUITRY PROTECTED AGAINST ACCIDENTAL
DEFIBRILLATOR DISCHARGE INTO PACEMAKER TEST TERMINALS

Description
9
ENERGY OUTPUT MEASUREMENT GENERAL
The unit measures the energy in the output pulse of both monophasic and biphasic
defibrillators.
• PULSE TYPE: Monophasic or Biphasic
• LOAD RESISTANCE: 50 ohm +/- 1%, non-inductive (<1 µH)
• DISPLAY RESOLUTION: 0.1 Joules
• MEASUREMENT TIME WINDOW: 100 ms
• ABSOLUTE MAX PEAK VOLTAGE: 6000 Volts
• CARDIOVERSION DELAY: 0 to 6000 ms
• CARDIOVERSION RESOLUTION: 0.1 ms
ENERGY OUTPUT MEASUREMENT HIGH RANGE
The high range allows for a large pulse with high voltage and current.
• VOLTAGE: <5000 Volts
• MAX CURRENT: 120 Amps
• MAX ENERGY: 1000 Joules
• TRIGGER LEVEL: 100 Volts
• PLAYBACK AMPLITUDE: 1 mV / 1000 V Lead I
• TEST PULSE: 125 Joules +/- 20%
ENERGY OUTPUT MEASUREMENT LOW RANGE
The low range allows greater resolution on smaller pulses.
• VOLTAGE: <1000 Volts
• MAX CURRENT: 24 Amps
• MAX ENERGY: 50 Joules
• TRIGGER LEVEL: 20 Volts
• PLAYBACK AMPLITUDE: 1 mV / 1000 V Lead I
• TEST PULSE: 5 Joules +/- 20%

DA-2006
10
ENERGY OUTPUT MEASUREMENT OTHER
OSCILLOSCOPE OUTPUT
• HIGH MEASUREMENT RANGE: 1000:1 amplitude-attenuated
• LOW MEASUREMENT RANGE: 200:1 amplitude-attenuated
WAVEFORM PLAYBACK
• OUTPUT – LEAD 1 & PLATES
• GRAPHICS SCREEN
• 200:1 Time Base Expansion
SYNC TIME MEASUREMENTS
• TIMING WINDOW: Starts at peak of each R-wave
• TEST WAVEFORMS: All waveform simulations available
CHARGE TIME MEASUREMENT
• From 0 .1 to 99.9 sec
ECG FUNCTIONS
The unit can produce a wide variety of ECG simulations. The user simply selects the
parameters that match the desired output.
• RATE: 30,40,45,60,80,90,100,120,140,160,180,200,220,240,260,280,300 BPM
• AMPLITUDE: 0.50,1.0,1.5,2.0 mV (Lead II)
ECG-PERFORMANCE FUNCTIONS
The unit can generate Sine, Square, Triangular, and Pulse waveforms with adjustable
amplitudes for performance testing.
• SINE: 0.1,0.2,0.5,5,10,40,50,60,100 Hz
• SQUARE: 0.125,2 Hz
• TRIANGLE: 2,2.5 Hz
• PULSE: 30,60,120 BPM; 60 ms WIDTH
• AMPLITUDE: 0.5,1.0,1.5,2.0 mV (Lead II)

Description
11
ARRHYTHMIA FUNCTIONS
The unit can simulate 12 different arrhythmias.
• VENTRICULAR FIBRILLATION
• ATRIAL FIBRILLATION
• SECOND DEGREE A-V BLOCK
• RIGHT BUNDLE BRANCH BLOCK
• PREMATURE ATRIAL CONTRACTION
• EARLY PVC
• STANDARD PVC
• R ON T PVC
• MULTIFOCAL PVC
• BIGEMINY
• RUN OF 5 PVC
• VENTRICULAR TACHYCARDIA
SHOCK ADVISORY TESTS
The unit can simulate 8 different waveforms to test the shock algorithm of advanced
defibrillators:
• ASYSTOLE
• COARSE VENTRICULAR FIBRILLATION
• FINE VENTRICULAR FIBRILLATION
• MULTIFOCAL VENTRICULAR TACHYCARDIA @ 140 BPM
• MULTIFOCAL VENTRICULAR TACHYCARDIA @ 160 BPM
• POLYFOCAL VENTRICULAR TACHYCARDIA @ 140 BPM
• POLYFOCAL VENTRICULAR TACHYCARDIA @ 160 BPM
• SUPRAVENTRICULAR TACHYCARDIA @ 90 BPM

DA-2006
12
TRANSCUTANEOUS PACER ANALYZER
The unit can test external transcutaneous pacemakers. It has a wide variety of loads and
can measure the Pacer Pulse, Demand Sensitivity and Refractory Periods (Pacing and
Sensing):
• LOAD:
• RANGE: 50,100,150,200,300,400,500,600,700,800,900,1000,1100,
1200,1300,1400,1500,1600,1700,1800,1900,2000,2100,
2200,2300 ohm
• PULSE:
• PULSE CURRENT: 4 TO 300 mA (100 ohm load)
• RATE: 30 TO 800 ppm
• WIDTH: 0.6 to 80 ms
• DEMAND SENSITIVITY:
• WAVEFORMS:
• SELECTIONS: SQUARE, TRIANGLE, HAVERSINE
• WIDTH: 10,25,40,100,200 ms
• ECG:
• AMPLITUDE – OUT: 0 to 4 mV
• PACER INPUT (50 TO 400 OHM):
• AMPLITUDE – OUT: 0 to 10 mV / 50 ohms
• RATE – IN: 30 to 120 ppm
• PACER INPUT (500 TO 2300 OHM & OPEN):
• AMPLITUDE – OUT: 0 to 100 mV
• RATE – IN: 30 to 120 ppm
• DEFIBRILLATOR PLATES:
• AMPLITUDE – OUT: 0 to 10 mV
• RATE – IN: 30 to 120 ppm
• REFRACTORY PERIOD:
• PACING: 20 to 500 ms
• SENSING: 20 to 500 ms
• 50/60 HZ INTERFERENCE TEST SIGNAL:
• ECG OUTPUT: 0,0.4,0.8,1.2,1.6,2.0,2.4,2.8,3.2,3.6,4.0 mV
• PACER INPUT 50 OHM: 0,1,2,3,4,5,6,7,8,9,10 mV
• PACER INPUT 100 OHM: 0,2,4,6,8,10,12,14,16,18,20 mV
• PACER INPUT 150 OHM: 0,3,6,9,12,15,18,21,24,27,30 mV
• PACER INPUT 200 OHM: 0,4,8,12,16,20,24,28,32,26,40 mV
• PACER INPUT 300 OHM: 0,6,12,18,24,30,36,42,48,54,60 mV
• PACER INPUT 400 OHM: 0,8,16,24,32,40,48,56,64,72,80 mV
• PACER INPUT > 500 OHM: 0,10,20,30,40,50,60,70,80,90,100 mV
• DEFIBRILLATOR PLATES: 0,1,2,3,4,5,6,7,8,9,10 mV
• INPUT CIRCUITRY PROTECTION
• INPUT CIRCUITRY IS PROTECTED AGAINST DAMAGE IN THE
EVENT OF AN ACCIDENTAL DEFIBRILLATOR DISCHARGE INTO
THE PACEMAKER TEST INPUT TERMINALS

Description
13
ACCESSORIES
BC20 - 40032 INTERNAL PADDLE ADAPTERS (2 adapters)
BC20 - 21103 BATTERY ELIMINATOR (120 VAC) (US Version)
BC20 - 21101 BATTERY ELIMINATOR (220 VAC) (Euro Version)
BC20 - 00427 PLASTIC ELECTRODE PLATES (2 plates)
OPTIONAL ACCESSORIES
BC20 - 30108 BC BIOMEDICAL MEDIUM SOFT SIDED CARRYING CASE
BC20 - 41341 COMMUNICATION CABLE (DB 9 M to DB 9 F)
BC20 - 00420 PHYSIO-CONTROL DEFIB / PACE TEST CABLE
BC20 - 00421 MARQUETTE DEFIB / PACE TEST CABLE
BC20 - 00423 ZOLL DEFIB/PACE TEST CABLE
BC20 - 00424 PHYSIO-CONTROL PACE ONLY TEST CABLE
BC20 - 00425 ZOLL PACE ONLY TEST CABLE
BC20 - 00426 HP / AGILENT / LAERDAL / AAMI
DEFIB / PACE TEST CABLE
This manual suits for next models
1
Table of contents
Other BC Biomedical Measuring Instrument manuals

BC Biomedical
BC Biomedical SA-2010S User manual

BC Biomedical
BC Biomedical IPA-2000 User manual

BC Biomedical
BC Biomedical SA-2500 User manual

BC Biomedical
BC Biomedical SPO-2000 User manual

BC Biomedical
BC Biomedical SPO-2000 User manual

BC Biomedical
BC Biomedical PFC-3000 SERIES User manual

BC Biomedical
BC Biomedical DPM-2350 SERIES User manual

BC Biomedical
BC Biomedical ESU-2400 User manual

BC Biomedical
BC Biomedical SA-2010S User manual

BC Biomedical
BC Biomedical SA-2000-INTL User manual