11 / EN
Hood / User Manual
3.1 Control of turbine
operation
In standby mode, the control panel is not
illuminated and the fields , and are
disabled. To activate the control panel, touch the
field or use the remote control (if enclosed).
After activation, the control panel is highlighted
and the touch field symbols appear; touching the
field starts the turbine at the recently used
gear, touching the field starts the turbine
at the highest gear and touching the field
starts the turbine at the lowest gear. The turbine
speed can be increased by touching the field ,
reducing - by touching the symbol . Disabling
the hood turbine is done by touching the field
or after touching the field when the turbine
is operating at first gear. Along with the change
of turbine speed, the digits on the display change
accordingly:
1- turbine operating in first gear, 2- turbine
operating in second gear, 3- turbine operating in
third gear, 4- turbine operating in intensive gear
(turbo).
In accordance with EU regulation 66/2014, the hood
is equipped with an automatic, five-minute counter,
which automatically changes the turbine level from
fourth gear into third after 5 minutes (does not
apply to the model with turbine number “5”).
3.2 Lighting control
To turn on the hood light, the symbol must be
pressed; another pressing of the symbol switches
the light off.
3
Operation of the Appliance
3.3 Additional information on
the hood control
The hood control is equipped with a hood
operation counter. The counter is set to 35 hours.
After this time expires, the display shows the
symbol indicating the recommended cleaning
of the aluminum filter. To delete the symbol
“F” on the hood display, the symbol must
be touched and held continuously for about 8
seconds.
The hood control is equipped with a touch panel
lock to deactivate the touch panel, for example
when cleaning the hood. To enable the lock, touch
and hold the symbol (for about 10 seconds)
until the symbol (dot in the lower right corner)
appears on the display. To return to normal
operation, touch and hold the symbol again
(for about 10 seconds) until the dot on the display
goes out. The hood control is equipped with a
time switch that disables the hood turbine after
15 minutes from the switching on of the counter.
The time switch of the turbine does not disable
the lighting and the speed of the turbine can be
freely changed. To activate the time switch, the
hood turbine must work on any speed on the 1, 2,
3 or intense gear. The timer is activated by holding
the symbol (for about 10 seconds), until a dot
starts to flash in the lower right corner. To disable
this feature, hold again the symbol (for about 10
seconds) or turn the hood off.
The hood control is equipped with a feature to
automatically turn off the turbine operation after
2 hours of inactivity of hood control.