Belden GRASS VALLEY DENSITE 3+ FR4 User manual

User Manual
M3007-9900-102
2016-06-22
DENSITÉ 3+ FR4
HOUSING FRAME

ii
Notices
Copyright and Trademark Notice
Copyright © 2015-2016, Grass Valley Canada. All rights reserved.
Belden, Belden Sending All The Right Signals, and the Belden logo are trademarks or
registered trademarks of Belden Inc. or its affiliated companies in the United States and
other jurisdictions. Grass Valley Canada, Miranda, Densité 3+ FR4, iControl, and Densité are
trademarks or registered trademarks of Grass Valley Canada. Belden Inc., Grass Valley
Canada, and other parties may also have trademark rights in other terms used herein.
Terms and Conditions
Please read the following terms and conditions carefully. By using Densité 3+ FR4
documentation, you agree to the following terms and conditions.
Grass Valley hereby grants permission and license to owners of Densité 3+ FR4 to use their
product manuals for their own internal business use. Manuals for Grass Valley products may
not be reproduced or transmitted in any form or by any means, electronic or mechanical,
including photocopying and recording, for any purpose unless specifically authorized in
writing by Grass Valley.
A Grass Valley manual may have been revised to reflect changes made to the product
during its manufacturing life. Thus, different versions of a manual may exist for any given
product. Care should be taken to ensure that one obtains the proper manual version for a
specific product serial number.
Information in this document is subject to change without notice and does not represent a
commitment on the part of Grass Valley.
Warranty information is available in the Support section of the Grass Valley Web site
(www.grassvalley.com).
Title Densité 3+ FR4 User Manual
Part Number M3007-9900-102
Revision 2016-06-22, 15:35

iii
Densité 3+ FR4
User Manual
Important Safeguards and Notices
Symbols and Their Meanings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
This section provides important safety guidelines for operators and service personnel.
Specific warnings and cautions appear throughout the manual where they apply. Please
read and follow this important information, especially those instructions related to the risk
of electric shock or injury to persons.
Symbols and Their Meanings
Indicates that dangerous high voltage is present within the equipment
enclosure that may be of sufficient magnitude to constitute a risk of electric
shock.
Indicates that the user, operator or service technician should refer to the product
manuals for important operating, maintenance, or service instructions.
This is a prompt to note the fuse rating when replacing fuses. The fuse
referenced in the text must be replaced with one having the ratings indicated.
Identifies a protective grounding terminal which must be connected to earth
ground prior to making any other equipment connections.
Identifies an external protective grounding terminal which may be connected to
earth ground as a supplement to an internal grounding terminal.
Indicates that static sensitive components are present, which may be damaged
by electrostatic discharge. Use anti-static procedures, equipment and surfaces
during servicing.
Indicates that the equipment has more than one power supply cord, and that all
power supply cords must be disconnected before servicing to avoid electric
shock.
The presence of this symbol in or on Grass Valley equipment means that it has
been tested and certified as complying with applicable Canadian Standard
Association (CSA) regulations and recommendations for USA/Canada.
The presence of this symbol in or on Grass Valley equipment means that it has
been tested and certified as complying with applicable Underwriters Laboratory
(UL) regulations and recommendations for USA/Canada.

iv
Notices
Warnings
A warning indicates a possible hazard to personnel, which may cause injury or
death. Observe the following general warnings when using or working on this
equipment:
• Appropriately listed/certified mains supply power cords must be used for the
connection of the equipment to the mains voltage at either 120 V AC or 240 V AC.
• This product relies on the building's installation for short-circuit (over-current)
protection. Ensure that a fuse or circuit breaker for 120 V AC or 240 V AC is used on the
phase conductors.
• Any instructions in this manual that require opening the equipment cover or enclosure
are for use by qualified service personnel only.
• Do not operate the equipment in wet or damp conditions.
• This equipment is grounded through the grounding conductor of the power cords. To
avoid electrical shock, plug the power cords into a properly wired receptacle before
connecting the equipment inputs or outputs.
• Route power cords and other cables so they are not likely to be damaged. Properly
support heavy cable bundles to avoid connector damage.
• Disconnect power before cleaning the equipment. Do not use liquid or aerosol
cleaners; use only a damp cloth.
• Dangerous voltages may exist at several points in this equipment. To avoid injury, do
not touch exposed connections and components while power is on.
• High leakage current may be present. Earth connection of product is essential before
connecting power.
• Prior to servicing, remove jewelry such as rings, watches, and other metallic objects.
• To avoid fire hazard, use only the fuse type and rating specified in the service
instructions for this product, or on the equipment.
• To avoid explosion, do not operate this equipment in an explosive atmosphere.
• Use proper lift points. Do not use door latches to lift or move equipment.
• Avoid mechanical hazards. Allow all rotating devices to come to a stop before servicing.
• Have qualified service personnel perform safety checks after any service.
The presence of this symbol in or on Grass Valley equipment means that it has
been tested and certified as complying with applicable Intertek Testing Services
regulations and recommendations for USA/Canada.
The presence of this symbol in or on Grass Valley product means that it complies
with all applicable European Union (CE) directives.
The presence of this symbol in or on Grass Valley product means that it complies
with safety of laser product applicable standards.

v
Densité 3+ FR4
User Manual
Cautions
A caution indicates a possible hazard to equipment that could result in equipment
damage. Observe the following cautions when operating or working on this
equipment:
• This equipment is meant to be installed in a restricted access location.
• When installing this equipment, do not attach the power cord to building surfaces.
• Products that have no on/off switch, and use an external power supply must be
installed in proximity to a main power outlet that is easily accessible.
• Use the correct voltage setting. If this product lacks auto-ranging power supplies,
before applying power ensure that each power supply is set to match the power
source.
• Provide proper ventilation. To prevent product overheating, provide equipment
ventilation in accordance with the installation instructions.
• Do not operate with suspected equipment failure. If you suspect product damage or
equipment failure, have the equipment inspected by qualified service personnel.
• To reduce the risk of electric shock, do not perform any servicing other than that
contained in the operating instructions unless you are qualified to do so. Refer all
servicing to qualified service personnel. Servicing should be done in a static-free
environment.
• This unit may have more than one power supply cord. Disconnect all power supply
cords before servicing to avoid electric shock.
• Follow static precautions at all times when handling this equipment.
Electrostatic Discharge (ESD) Protection
Electrostatic discharge occurs when electronic components are improperly
handled and can result in intermittent failure or complete damage adversely
affecting an electrical circuit. When you remove and replace any card from a frame
always follow ESD-prevention procedures:
• Ensure that the frame is electrically connected to earth ground through the power cord
or any other means if available.
• Wear an ESD wrist strap ensuring that it makes good skin contact. Connect the
grounding clip to an unpainted surface of the chassis frame to safely ground unwanted
ESD voltages. If no wrist strap is available, ground yourself by touching the unpainted
metal part of the chassis.
• For safety, periodically check the resistance value of the antistatic strap, which should
be between 1 and 10 megohms.
• When temporarily storing a card make sure it is placed in an ESD bag.
• Cards in an earth grounded metal frame or casing do not require any special ESD
protection.
Mesures de sécurité et avis importants
Signification des symboles utilisés . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii

vi
Notices
Mises en gardeLes mises en garde signalent des conditions ou des pratiques susceptibles
d’endommager l’équipement. Veuillez vous familiariser avec les mises en garde ci-dessous :
viiiLa présente section fournit des consignes de sécurité importantes pour les opérateurs et
le personnel de service. Des avertissements ou mises en garde spécifiques figurent dans le
manuel, dans les sections où ils s’appliquent. Prenez le temps de bien lire les consignes et
assurez-vous de les respecter, en particulier celles qui sont destinées à prévenir les
décharges électriques ou les blessures.
Signification des symboles utilisés
Signale la présence d’une tension élevée et dangereuse dans le boîtier de
l’équipement ; cette tension peut être suffisante pour constituer un risque de
décharge électrique.
Avertit l'utilisateur, l’opérateur ou le technicien de maintenance que des
instructions importantes relatives à l'utilisation et à l'entretien se trouvent dans
la documentation accompagnant l’équipement.
Invite l'utilisateur, l’opérateur ou le technicien de maintenance à prendre note du
calibre du fusible lors du remplacement de ce dernier. Le fusible auquel il est fait
référence dans le texte doit être remplacé par un fusible du même calibre.
Identifie une borne de mise à la terre de protection. Il faut relier cette borne à la
terre avant d’effectuer toute autre connexion à l’équipement.
Identifie une borne de mise à la terre externe qui peut être connectée en tant
que borne de mise à la terre supplémentaire.
Signale la présence de composants sensibles à l’électricité statique et qui sont
susceptibles d’être endommagés par une décharge électrostatique. Utilisez des
procédures, des équipements et des surfaces antistatiques durant les
interventions d’entretien.
Le symbole ci-contre signifie que l’appareil comporte plus d’un cordon
d'alimentation et qu’il faut débrancher tous les cordons d'alimentation avant
toute opération d’entretien, afin de prévenir les chocs électriques.
La marque C-CSA-US certifie que l’appareil visé a été testé par l'Association
canadienne de normalisation (CSA) et reconnu conforme aux exigences
applicables en matière de sécurité électrique en vigueur au Canada et aux États-
Unis.
La marque C-UL-US certifie que l’appareil visé a été testé par Underwriters
Laboratory (UL) et reconnu conforme aux exigences applicables en matière de
sécurité électrique en vigueur au Canada et aux États-Unis.

vii
Densité 3+ FR4
User Manual
Avertissements
Les avertissements signalent des conditions ou des pratiques susceptibles
d’occasionner des blessures graves, voire fatales. Veuillez vous familiariser avec les
avertissements d’ordre général ci-dessous :
• Un cordon d’alimentation dûment homologué doit être utilisé pour connecter
l’appareil à une tension de secteur de 120 V CA ou 240 V CA.
• La protection de ce produit contre les courts-circuits (surintensités) dépend de
l’installation électrique du bâtiment. Assurez-vous qu'un fusible ou un disjoncteur pour
120 V CA ou 240 V CA est utilisé sur les conducteurs de phase.
• Dans le présent manuel, toutes les instructions qui nécessitent d’ouvrir le couvercle de
l’équipement sont destinées exclusivement au personnel technique qualifié.
• N’utilisez pas cet appareil dans un environnement humide.
• Cet équipement est mis à la terre par le conducteur de mise à la terre des cordons
d’alimentation. Pour éviter les chocs électriques, branchez les cordons d’alimentation
sur une prise correctement câblée avant de brancher les entrées et sorties de
l’équipement.
• Acheminez les cordons d’alimentation et autres câbles de façon à ce qu’ils ne risquent
pas d’être endommagés. Supportez correctement les enroulements de câbles afin de
ne pas endommager les connecteurs.
• Coupez l’alimentation avant de nettoyer l’équipement. Ne pas utiliser de nettoyants
liquides ou en aérosol. Utilisez uniquement un chiffon humide.
• Des tensions dangereuses peuvent exister en plusieurs points dans cet équipement.
Pour éviter toute blessure, ne touchez pas aux connexions ou aux composants exposés
lorsque l’appareil est sous tension.
• Avant de procéder à toute opération d’entretien ou de dépannage, enlevez tous vos
bijoux (notamment vos bagues, votre montre et autres objets métalliques).
• Pour éviter tout risque d’incendie, utilisez uniquement les fusibles du type et du calibre
indiqués sur l’équipement ou dans la documentation qui l’accompagne.
• Ne pas utiliser cet appareil dans une atmosphère explosive.
• Présence possible de courants de fuite. Un raccordement à la masse est indispensable
avant la mise sous tension.
La marque ETL Listed d’Intertek pour le marché Nord-Américain certifie que
l’appareil visé a été testé par Intertek et reconnu conforme aux exigences
applicables en matière de sécurité électrique en vigueur au Canada et aux États-
Unis.
Le marquage CE indique que l’appareil visé est conforme aux exigences
essentielles des directives applicables de l’Union européenne en matière de
sécurité électrique, de compatibilité électromagnétique et de conformité
environnementale.
Le symbole ci-contre sur un appareil Grass Valley ou à l’intérieur de l’appareil
indique qu’il est conforme aux normes applicables en matière de sécurité laser.

viii
Notices
• Après tout travail d’entretien ou de réparation, faites effectuer des contrôles de sécurité
par le personnel technique qualifié.
Mises en gardeLes mises en garde signalent des conditions ou des pratiques
susceptibles d’endommager l’équipement. Veuillez vous familiariser avec les mises
en garde ci-dessous :
• L’appareil est conçu pour être installé dans un endroit à accès restreint.
• Au moment d’installer l’équipement, ne fixez pas les cordons d’alimentation aux
surfaces intérieures de l’édifice.
• Les produits qui n'ont pas d’interrupteur marche-arrêt et qui disposent d’une source
d’alimentation externe doivent être installés à proximité d'une prise de courant facile
d’accès.
• Si l’équipement n’est pas pourvu d’un modules d’alimentation auto-adaptables, vérifiez
la configuration de chacun des modules d'alimentation avant de les mettre sous
tension.
• Assurez une ventilation adéquate. Pour éviter toute surchauffe du produit, assurez une
ventilation de l’équipement conformément aux instructions d’installation.
• N’utilisez pas l’équipement si vous suspectez un dysfonctionnement du produit. Faites-
le inspecter par un technicien qualifié.
• Pour réduire le risque de choc électrique, n'effectuez pas de réparations autres que
celles qui sont décrites dans le présent manuel, sauf si vous êtes qualifié pour le faire.
Confiez les réparations à un technicien qualifié. La maintenance doit se réaliser dans un
milieu libre d’électricité statique.
• L’appareil peut comporter plus d’un cordon d'alimentation. Afin de prévenir les chocs
électriques, débrancher tous les cordons d'alimentation avant toute opération
d’entretien.
• Veillez à toujours prendre les mesures de protection antistatique appropriées quand
vous manipulez l’équipement.
Protection contre les décharges électrostatiques (DES)
Une décharge électrostatique peut se produire lorsque des composants
électroniques ne sont pas manipulés de manière adéquate, ce qui peut entraîner
des défaillances intermittentes ou endommager irrémédiablement un circuit
électrique. Au moment de remplacer une carte dans un châssis, prenez toujours les
mesures de protection antistatique appropriées :
• Assurez-vous que le châssis est relié électriquement à la terre par le cordon
d'alimentation ou tout autre moyen disponible.
• Portez un bracelet antistatique et assurez-vous qu'il est bien en contact avec la peau.
Connectez la pince de masse à une surface non peinte du châssis pour détourner à la
terre toute tension électrostatique indésirable. En l’absence de bracelet antistatique,
déchargez l’électricité statique de votre corps en touchant une surface métallique non
peinte du châssis.
• Pour plus de sécurité, vérifiez périodiquement la valeur de résistance du bracelet
antistatique. Elle doit se situer entre 1 et 10 mégohms.
• Si vous devez mettre une carte de côté, assurez-vous de la ranger dans un sac
protecteur antistatique.

ix
Densité 3+ FR4
User Manual
• Les cartes qui sont reliées à un châssis ou boîtier métallique mis à la terre ne
nécessitent pas de protection antistatique spéciale.
Recycling
Visit www.grassvalley.com for recycling information.
Certification and Compliance
Safety Compliance
This equipment complies with the requirements of CSA/UL/IEC/EN 60950-1, 2nd
Ed. + AM1, Safety of information technology equipment.
The power cords supplied with this equipment meet the appropriate national
standards for the country of destination.
Environmental Compliance
GVN FR4
部件名称 Part name
有毒有害物质或元素 (Toxic or hazardous substances and elements)
铅
(Pb)
汞
(Hg)
镉
(Cd)
六价铬
(Cr6)
多溴联苯
(PBB)
多溴二苯
(PBDE)
电缆及电缆组件 Cables and cable assemblies XOOOOO
电路模块 Circuit modules X O X O O O
显示装置 Display Assemblies XOOOOO
组装风扇 Fan Assemblies XOOOOO
金属零件 Metal parts XOOOOO
O: 表示该有毒有害物质在该部件所有均质材料中的含量均在 GB/T 26572-2011 规定的
限量要求以下。
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous
materials for this part is below the limit requirement in GB/T 26572-2011.
X: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572-2011
规定的限量要求。
X:Indicates that this toxic or hazardous substance contained in at least one of the
homogeneous materials for this part is above the limit requirement in GB/T 26572-2011.
技术条款解释:此声明所依据之数据由 Grass Valley 环境管理部门向我们的部件供
应商获取。Grass Valley 公司相信此信息的正确性,但由于数据来源于公司外部,我
们无法保证它的完整和准确。所有这些特性可能在未获通知的情况下更改。
Technical explanations: This statement is based on the information provided by our
suppliers of components and collected through our Grass Valley’s environmental
management system. Grass Valley believes this environmental information to be correct
but cannot guarantee its completeness or accuracy as it is based on data received from
sources outside our company. All specifications are subject to change without notice.

x
Notices
Electromagnetic Compatibility
This equipment has been tested for verification of compliance with FCC Part 15,
Subpart B requirements for class A digital devices.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy, and, if
not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
This equipment has been tested and found to comply with the requirements of
the EMC directive 2004/108/EC:
• EN 55022 Class A Radiated and conducted emissions
• EN 61000-3-2 Limits for harmonic current emissions
• EN 61000-3-3 Limitation of voltage fluctuations and flicker
• EN 61000-4-2 Electrostatic discharge immunity
• EN 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity
• EN 61000-4-4 Electrical fast transient immunity
• EN 61000-4-5 Surge transient immunity
• EN 61000-4-6 Conducted disturbances immunity
• EN 61000-4-8 Power frequency magnetic field immunity
• EN 61000-4-11 Voltage dips, short interruptions and voltage variations
immunity

xi
Table of Contents
1Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
The Densité 3+ FR4 Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Overview - Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Overview - Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Mechanical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Controller Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
2Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Opening the Front Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installing Cards in the Densité 3+ FR4 Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Installing the Power Cord Retaining Clips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
3Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Control Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Using the Ethernet interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Using the local control interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Using the Controller’s web page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Configuring the CPU-ETH3 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Status Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Link Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Data Restoration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Factory Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Time Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Local Control Panel Menu - CPU-ETH3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Upgrading the CPU-ETH3 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Configuring the Frame Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Reference Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
URS Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Timecode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37

xii
Table of Contents
Factory Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Upgrading the Frame Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4Service and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Changing the Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Replacing the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Replacing the Frame Ventilation Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Cleaning and replacing the front-door air filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Contact Us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Grass Valley Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Corporate Head Office . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

1
Introduction
Summary
Overview - Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1
Overview - Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2
Mechanical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3
Controller Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6
The Densité 3+ FR4 Frame
Overview - Frame
The 4 RU Densite 3+ FR4 Frame from Grass Valley, a Belden Brand, is a modular frame and
controller designed to deliver more power per slot and higher speed connectivity needed by
the increased feature set of the latest Densité products. The Densité 3+ FR4 frame offers true
multiformat operation, with the ability to process simultaneously SDI and IP 4K, 3G, HD, SD, and
analog video, as well as AES and analog audio. The frame provides advanced monitoring and
back-up capabilities along with a color LCD panel with integrated touchscreen for ease of status
and control navigation on the front panel.
The front-opening frame features dual hot-swappable power supplies (PSUs) and fans. The
processing modules or cards for the frame are also hot-swappable, and can be configured auto-
matically when a card is replaced. The frame is front-to-back air-cooled and all modules,
redundant PSUs and fans are monitored to provide status via GPI or the Ethernet port. The basic
frame configuration includes one PSU and a controller that allows card parameters to be
adjusted from the front panel.

2
Introduction
Key Product Capabilities
•Fully backwards compatible with Densité 2 and Densité 3 cards.
•24 slots with a power budget of 25 watts per slots.
•Optional frame reference on controller card.
•Fully modular I/O for the frame controller for “future readiness” of the controller I/O.
•Dual GigE port for system wide redundancy.
•Full touchscreen color LCD panel for module status and control.
Standard Densité capabilities
•Multiple video and audio formats can be fitted in a single frame.
•Densité 3 RU and Densité 2 RU modules can co-exist in the same frame.
•Easy configuration by front panel or remotely via the Ethernet frame controller.
•Choice of control panels, including the PC-based iControl Solo GUI.
•Hot-swappable power supply, with optional redundant power supply.
•Supports full range of Densité Series modules.
•Frame can be stacked without additional cooling spaces.
•Optional redundant Ethernet connection.
Available Options
•Second power supply for redundant power security
•Full link redundancy using Channel Bonding on the CPU-ETH3
•Frame reference integrated with controller
Cards (maximum 24 per frame)
The Densité 3+ FR4 housing frame supports all current Densité 3 series cards directly. Many
Densité 2 series cards can also be installed with the use of an adapter that fits on the card, plus
an additional adapter to extend the rear panel if a dedicated 3RU rear is not available..
Overview - Controller
The CPU-ETH3 controller installed in the Densité 3+ FR4 frame supports all on-frame communi-
cation between cards, and incorporates a touch-screen panel for local control and adjustment of
the frame and installed cards. The CPU-ETH3 controller serves as the communications port for
control and alarm information entering and leaving the frame. The CPU-ETH3 controller features
two Ethernet ports for system-wide monitoring and control of the frame, using Miranda’s
control solutions. This controller card is compatible with the TCP/IP protocol and can support
polling or report on error modes (unsolicited messaging).

3
Densité 3+ FR4
User Manual
Features
•Dual Ethernet RJ-45 ports (100Base-T and Gigabit Ethernet) - the two ports can be config-
ured independently for full network redundancy
•Provides ultra-robust Ethernet connectivity for LAN/WAN
•Accelerated data throughput: allows video thumbnail and audio level meter and line scope
streaming from all installed modular cards
•Linux-based operating system for robust, mission-critical operations
•Removable SD memory card for portable and quickly-recoverable device and frame configu-
ration
•User-configurable GPI alarm port
•Features front display panel and push-buttons for local configuration of cards and frame
•Can be remotely configured via iControl
•Provides card and frame health monitoring and status reporting
•Provides extensive frame monitoring:
-Ethernet port monitoring, with communication settings and overall bit rate
-detailed bitrate and communication thoughput from individual cards
-self-monitoring with CPU load, memory usage
-Power Supply and GPI status reporting
•Individual Card parameter storage for easy card swapping
•optional integrated frame refrence module
Description
Mechanical Layout
The Densité 3+ FR4 is a 4 RU frame.
•The upper section contains the power supplies and the controller card.
•The lower portion consists of 24 slots that accept Densité-3 cards.

4
Introduction
Front of the frame
When the frame door is closed, the controller card touch screen is exposed through an opening
in the top center of the door. All other front elements are concealed by the door.
Rear of the Frame
The rear of the Densité 3+ FR4 frame is divided into two sections.
•Upper section contains the controller rear panel in the center, flanked by a fan assembly on
each side, and by the power supply AC inputs at each end
•Lower section contains the rear panels for the Densité cards installed in the 24 available
slots.

5
Densité 3+ FR4
User Manual
Controller Rear Panel
The rear panel associated with the frame’s controller card is located at the top center of the
frame. All inputs and outputs to the controller from outside the frame are connected through
this panel.
CONTROL PORT ETH (100 Mbps / GigE)
The two Ethernet links are connected to these RJ45 connectors.
REF IN 1
External reference signal for the frame, with a loop-through, on DIN connectors.
LTC IN
External time codeis connected to this DIN connector.
GPI
Alarms generated on the controller card may be reported on the GPI connector on the rear
panel.

6
Introduction
Specifications
Users who wish to utilize this alarm reporting mech-
anism should be aware of the circuit driving the GPI
connector, in order to correctly interpret its
signalling.
Specifications
MECHANICAL
Dimensions 4RU x 19” W (485 mm) x 11.25” D (286 mm) with connectors
Weight: 7.16 lbs (3,25 kg) with 1 PSU and controller card installed
POWER
Input Range: AC 100-240V, 50-60 Hz
Frame Rating: 700 W
Operating Temp. Range: 0-40° C
COOLING
Fans: 6 on frame (2 assemblies of 3 fans each), serviceable
2 on each installed power supply
COMMUNICATION
Connectors: RJ45 (2)
Compliant to: Ethernet 100 Mbps / GigE
ALARM
Connectors: GPI
REFERENCE
IN 1 and loop-thru
Connectors DIN
TIME CODE
LTC IN
Connector DIN

7
Installation
Summary
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Opening the Front Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installing Cards in the Densité 3+ FR4 Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Using Densité 2 cards in the Densité 3+ FR4 Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installing the Power Cord Retaining Clips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installation
Unpacking
Make sure the following items have been shipped with your Densité 3+ FR4 frame:
• Densité 3+ FR4 frame, including 1 Power Supply unit (AC in) with power cord
• Frame controller (Densité 3+ CPU-ETH3)
• Power cord retaining clips (2)
• A second power supply and AC cord (optional)
• Densité-series cards (per order) with associated rear panels
Opening the Front Door
The front door of the Densité 3+ FR4 frame is hinged on the right-hand side, and latched by a
captive thumbscrew on the left-hand side. There are no electrical connections to the door.
To open the door
• Turn the thumbscrew clockwise until it releases, and pull the door open.
• The door can be removed completely after it is open by sliding it vertically off the hinge pins
on the right-hand side.
To install and close the door
• Slide the door down onto the hinge pins on the right-hand side
• Push the door into the closed position and turn the thumbscrew on the left-hand side coun-
terclockwise to latch the door in the closed position.

8
Installation
Mounting
Mounting
The Densité 3+ FR4 housing frame occupies 4RU in a standard 19” rack.
To mount the frame
• Remove the front door to expose the rack mounting flanges at the ends of the chassis.
• Install the frame in the rack using 8 standard rack-mounting screws (not supplied) through
the eight holes in the mounting flanges.
Installing Cards in the Densité 3+ FR4 Frame
All Densité-series cards can be installed with the frame power on. Each card has a connector
which plugs into the frame’s backplane for distribution of power and connection to the
controller card, and a second connector that plugs into the associated rear panel for inputs and
outputs.
IMPORTANT - the rear panel must be installed before the card is inserted into the frame.
Note: If you need to install a Densité 2 series card in this frame, which has Densité 3 slots, please
see Using Densité 2 cards in the Densité 3+ FR4 Frame, on page 9
To install the rear connector panel
1 If a card is installed in the slot whose rear panel is being changed, remove it as described
below.
2 Remove the existing panel (either blank or belonging to an existing card that is being
changed) by releasing the captive screw(s) on the bottom
3 Position the new panel and secure it in place with the captive screw(s) on the bottom.
This manual suits for next models
1
Table of contents
Other Belden Controllers manuals

Belden
Belden Hirschmann BAT-Controller WLC Series User manual

Belden
Belden Miranda DENSITE 3+ FR1 User manual

Belden
Belden Miranda DENSITE 3+ FR1 User manual

Belden
Belden Miranda NV915 User manual

Belden
Belden Hirschmann iVISOR DS85 User manual

Belden
Belden Grass Valley Densite 3 Frame Instruction Manual

Belden
Belden Grass Valley iTX Master Control User manual

Belden
Belden Miranda DENSITE Series Instruction Manual