This equipment is designed specifically for domestic purposes
and Belling Appliances Limited cannot accept responsibility if used in any
other type of installation.
This appliance must not be installed over any appliance that
generates heat.
Before you cook for the first time, we recommend that you switch on each
element in turn to burn off any odours remaining from manufacture.
Simply operate the grill on maximum for a few minutes, and the oven for
about 30 mins.
For your own safety, we recommend that your cooker is installed by a
qualified electrician. The cooker should be installed in accordance
with the latest Edition of the IEE Regulations.
WARNING:– THIS APPLIANCE MUST BE EARTHED.
THE INSTALLER MUST check that the voltage shown at the rating plate
corresponds with the house electricity supply.
The oven must be supplied via a suitable double pole isolating switch,
having a contact separation of at least 3mm in all poles placed in a readily
accessible position adjacent to the unit.
If the oven is to be wired into a connector unit this may be positioned
behind the oven provided the following requirements are met:
i) The connector unit must not project from the wall more than 25mm.
ii) The top of the connector must not be more than 130mm above floor
level.
Remove the terminal cover at the rear base of the oven. Pass the cable
through the cable clamp and connect to the appropriate
terminals provided. Allow sufficient cable so that the oven can be set
down on the floor whilst still connected up. Tighten the screws on the
cable clamp and replace the terminal cover. Make mains connections.
This appliance conforms to B.S. EN 55014 regarding suppression of Radio
and Television reception interference.
Where a double oven is used a 32 amp double pole control switch should
be used to feed the unit using a suitable rated cable. We recommend that
a minimum of 4mm2PVC insulated twin and earth cable conforming to
B.S. 6004. Where a hob is fitted adjacent to an oven then a 45 amp Double
Pole control switch should be used to feed both units via separate suitably
rated cables. We recommend that a minimum of 4mm2PVC insulated twin
and earth cable conforming to B.S. 6004.
In all cases adhere to routing details (see Fig.5).
Important
Before Cooking
Electrical
Requirements
Electrical
Connections
Installation Instructions
6
Note: Due to many different types of installation, a mains cable is
not supplied with this product. The installer will fit the correct type
and length of cable.