Caractéristiques techniques
Coordination de l´isolement selon IEC 60664-1 / IEC 60664-3
Tension assignée ...................................................................................................................... 250 V
Qualité diélectrique / degré de pollution ........................................................................... 4 kV / III
Séparation sûre (isolation renforcée) entre .......................................................................................
............................................................................ (L1, L2, E, KE, T1, T2, A, B, Z, Z/k, I) - (11, 12, 14)
Essai diélectrique selon IEC 61010-1 .................................................................................. 2,21 kV
Tension d´alimentation
Tension d´alimentation Us...................................................................................................... = Un
Consommation propre .......................................................................................................... ≤4 VA
Réseau IT surveillé selon IEC 60364-7-710:2002-11
Tension réseau Un....................................................................................................... AC 70...264 V
Fréquence nominale fn.................................................................................................... 47...63 Hz
Surveillance de l´isolement selon IEC 61557-8: 2007-01
Valeur de seuil Ran .................................................................................... 50…500 k
Ω
(50 k
Ω
)*
Erreur relative de la valeur de réponse ................................................................................. ±10 %
Hystérèse................................................................................................................................... 25 %
Temps de réponse tan pour RF= 0,5 x Ran et Ce= 0,5 μF ....................................................... ≤5 s
Capacité de fuite Ce.................................................................................................................... 5 μF
Circuit de mesure
Tension de mesure Um........................................................................................................... ±12 V
Courant de mesure Im(pour RF= 0
Ω
) .............................................................................. ≤50 μA
Résistance interne DC Ri................................................................................................... ≥240 k
Ω
Impédance Zipour 50 Hz ................................................................................................. ≥200 k
Ω
Tension DC maxi. étrangère Ufg ..................................................................................... ≤DC 300 V
Injecteur de courant de localisation selon IEC 61557-9 : 2009
Courant de localisation ........................................................................................................
≤1 mA
Durée impulsion/durée pause............................................................................................... 2 s / 4 s
Surveillance du courant de charge
Valeur de seuil paramétrable ................................................................................. 5…50 A (7 A)*
Erreur relative de la valeur de réponse .................................................................................. ± 5 %
Hystérèse..................................................................................................................................... 4 %
Valeurs de réglage mesure du courant de charge :
Transformateur..... 3150VA ...... 4000VA ...... 5000VA ...... 6300VA ......8000VA .... 10000 VA
Ialarm 1~ .......................14A ............ 18A ............. 22 A ............. 28 A ............ 35 A ............ 45 A
Surveillance de la température
Valeur de seuil (valeur fixe) ..................................................................................................... 4 k
Ω
Valeur de relâchement (valeur fixe) ..................................................................................... 1,6 k
Ω
Sonde selon DIN 44081............................................................................................. max. 6 en série
Erreur relative de la valeur de réponse ................................................................................ ± 10 %
Affichage, mémoire
Affichage écran à cristaux liquides............................................... multi fonctions, non rétroéclairé
Valeur mesurée résistance d´d´isolement ............................................................ 10 k
Ω
…1 M
Ω
Erreur de fonctionnement .................................................................................... ± 10 %, ± 2 k
Ω
Valeur mesurée courant de charge (en % de la valeur de seuil préréglée) ........... 10 %…199 %
Erreur de fonctionnement ....................................................................................... ± 5 %, ± 0,2 k
Mot de passe .......................................................................................... on, off / 0…999 (off, 0)*
Interface
Interface / protocole....................................................................................................RS-485 / BMS
Vitesse de transmission .................................................................................................... 9,6 kBit/s
Longueur du câble .......................................................................................................... 0...1200 m
Câble recommandé (blindé, blindage sur PE) .............................................. mini. J-Y(St)Y 2 x 0,6
Résistance terminale ......................................................... 120 Ω(0,25 W), interne, commutable
Adresse des appareils, bus BMS....................................................................................... 2...90 (3)*
Interfaces pour tore de détection STW2 et sonde de
température
Longueur du câble :
unifilaire > 0,5 mm² ............................................................................................................... ≤1 m
unifilaire, torsadé> 0,5 mm² ............................................................................................... ≤10 m
Technical data
Insulation coordination acc. to IEC 60664-1 / IEC 60664-3
Rated insulation voltage............................................................................................................250 V
Rated impulse voltage/pollution degree..............................................................................4 kV / III
Protective separation (reinforced insulation) between: ...................................................................
........................................................................... (L1, L2, E, KE, T1, T2, A, B, Z, Z/k, I) - (11, 12, 14)
Voltage test according to IEC 61010-1 ................................................................................ 2.21 kV
Supply voltage
Supply voltage US.......................................................................................................................= Un
Power consumption .............................................................................................................. ≤4 VA
IT system being monitored acc. IEC 60364-7-710:2002-11
Nominal system voltage Un.........................................................................................AC 70...264 V
Rated frequency fn.............................................................................................................47...63 Hz
Insulation monitoring acc. to IEC 61557-8: 2007-01
Response value Ran..................................................................................... 50…500 k
Ω
(50 k
Ω
)*
Relative uncertainty............................................................................................................... ±10 %
Hysteresis.................................................................................................................................... 25%
Response time tan at RF= 0.5 x Ran and Ce= 0.5 μF ............................................................... ≤5 s
Permissible system leakage capacitance Ce............................................................................... 5 μF
Measuring circuit
Measuring voltage Um........................................................................................................... ±12 V
Measuring current Im(at RF= 0
Ω
).................................................................................... ≤50 μA
Internal DC resistance Ri................................................................................................... ≥240 k
Ω
Impedance Zi, at 50 Hz...................................................................................................... ≥200 k
Ω
Permissible extraneous DC voltage Ufg ......................................................................... ≤DC 300 V
Locating current injector acc. to IEC 61557-9: 2009
Locating current ....................................................................................................................≤ 1 mA
Test cycle/idle time ............................................................................................................... 2 s / 4 s
Load current monitoring
Response value, adjustable.................................................................................... 5…50 A (7 A)*
Relative uncertainty................................................................................................................ ± 5 %
Hysteresis......................................................................................................................................4 %
Setting value load current measurement:
Transformer .......... 3150VA ...... 4000VA ...... 5000VA ....... 6300VA ...... 8000VA .... 10000 VA
Ialarm 1~ ....................... 14A ............. 18 A ............. 22 A............. 28A ............ 35 A ............. 45 A
Temperature monitoring
Response value (fixed value) .....................................................................................................4 k
Ω
Release value (fixed value).....................................................................................................1.6k
Ω
PTC resistors acc. to DIN 44081 ............................................................................... max. 6 in series
Relative uncertainty.............................................................................................................. ± 10 %
Displays, memory
LC display....................................................................................... multifunctional, not illuminated
Measured value insulation resistance..................................................................... 10 k
Ω
…1 M
Ω
Operating uncertainty ............................................................................................± 10 %, ± 2 k
Ω
Measured value load current (as % of the set response value) ............................. 10 %…199 %
Operating uncertainty ............................................................................................ ± 5 %, ± 0.2 A
Password.................................................................................................. on, off / 0…999 (off, 0)*
Interface
Interface/protocol........................................................................................................RS-485 / BMS
Baud rate .......................................................................................................................... 9.6 kbit / s
Cable length..................................................................................................................... 0...1200 m
Recommended cable (shielded, shield connected to PE at one end) ....... at least J-Y(St)Y 2 x 0.6
Terminating resistor ............................................................. 120 Ω(0.25 W), internal, switchable
Device address, BMS bus................................................................................................. 2...90 ( 3)*
Interfaces for measuring current transformer STW2 and tem-
perature sensor
Cable lengths:
Single wire > 0.5 mm² .......................................................................................................... ≤1 m
Single wire, twisted > 0.5 mm² ......................................................................≤ 10 m