manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bender
  6. •
  7. Measuring Instrument
  8. •
  9. Bender LINETRAXX RCM410R-2 User manual

Bender LINETRAXX RCM410R-2 User manual

Intended Use
For intended operation, the specifications in the Technical
Data and in the manual must be observed.
Any use other than that described in this manual is regar-
ded as improper.
Mounting
Schraubbefestigung / Screw mounting
100
M4
Nm
1.0
!
i
Part of the device documentation, in addition to this
quickstart, are the enclosed "Safety instructions for
Bender products" and the corresponding manual,
which can be downloaded from https://www.ben-
der.de/en/service-support/downloads.
Scope of delivery:
RCM410R-24/-2, Quickstart DE/EN, Safety instructions
Ordering details:
AC and pulsed DC sensitive residual current
monitor
i
Bestandteil der Gerätedokumentation sind neben
dieser Kurzanleitung die „Sicherheitshinweise für
Bender-Produkte“unddasdazugehörigeHandbuch,
das unter https://www.bender.de/service-support/
downloadbereich herunter geladen werden kann.
Lieferumfang:
RCM410R-24/-2, Kurzanleitung DE/EN, Sicherheitshinweise
Bestellangaben:
Typ / Type Versorgungsspannung Us/ Supply voltage UsArt.-Nr. / Art. No. Handbuch Nr. / Manual No.
RCM410R-24 DC 24V B74602000 D00403
RCM410R-2 AC/DC 100…240V (47…63 Hz) B74603000
Bestimmungsgemäße Verwendung
Zum bestimmungsgemäßen Betrieb sind die Spezifika-
tionen in den Technischen Daten und im Handbuch zu
beachten.
Eine andere oder darüber hinausgehende Benutzung gilt
als nicht bestimmungsgemäß.
Montage
Montage auf Hutschiene / DIN rail mounting
1.
2.
2.
1.
Click!
LINETRAXX® RCM410R-24/-2
Montage
Mounting
Demontage
Removal
RCM410R_D00403_02_Q_DEEN /07.2022
Wechsel- und pulsstromsensitives
Differenzstrom-Überwachungsgerät
Kurzanleitung / Quickstart-guide
18
8,8
100
109
93
64
48.5
45
1
65
35
2 x Ø 4,2
18
8,8
100
109
93
64
48.5
45
1
65
35
2 x Ø 4,2
ON
Bender
RCM410R
T / R
ton(s)
Ext 10 42
1
0,8
0,6
0,40,20
I∆n(A)
Ext 30 10 5
1
0,5
0,3
0,1,03,01
25
%
50
75
%
100
2
AL
1
S2S1
**
A2A2
A1A1
11 14 12
BA-+
Anschluss / Connection
Anschluss / Terminal Verbindung / Connection
A1, A2 Versorgungsspannung Us / Supply voltage Us
S1, S2 Messstromwandler / Current transformer
11, 14, 12 Alarmrelais K1 / Alarm relay K1
++24V
–Masse / Ground
ARS-485 A
BRS-485 B
S2
S1
A2
A1
US
CT
S2
S1
CT
A
B
+
–
14
12
11
24 V COM K1
Terminierung RS-485 erstes und letztes Gerät
Termination RS-485 first and last device
B
A
RS-485
120 Ω
> 0.25 W
i
Bei mehr als 16 Bus-Teilnehmern der Ge-
rätevariante RCM410R-2ist dieSchnittstelle
berührungssicher auszuführen, weil der
max. zulässige Gesamt-Arbeitsstrom von
0,5 mA überschritten werden kann.
i
If there are more than 16 bus devices of the
RCM410R-2 device variant, the interface
must be designed to be touchproof, becau-
se the maximum operating current of 0.5
mA could be exceeded.
S2
L1 L2 L3 N
Verbraucher
Load
S1
11
14
12
RS-485
B
A
–
+24 V
+
S1 (k)
S2 (l)
RCM410R-24
S2
L1 L2 L3 N
Verbraucher
Load
S1
A1
US
~/+ ~/–
A2
RS-485
B
A
–
(+24 V) optional
+
11
14
12
S1 (k)
S2 (l)
RCM410R-2
I Vorsicht! Kurzschluss. Bei direktem Einschub fein-
drähtiger Leitungen in die Push-In-Klemmen kön-
nen gespleißte Drähte einen Kurzschluss verursa-
chen. Verwenden Sie Aderendhülsen.
I caution! Short circuit. When finely stranded cables
are inserted directly into the push-in terminals,
spliced wires can cause a short circuit. Use ferrules.
i
Das Anschlussvermögen für die Push-In Klemmen ist in
den Technischen Daten und im Handbuch spezifiziert.
In UL-Anwendungen nur 60/75 °C-Kupferleitungen
verwenden!
i
The connection capacity for the push-in terminals is
specified in the technical data and in the manual.
In UL applications use 60/75 °C copper lines only!
RCM410R-2RCM410R-24
i
*
i
* Achtung! In UL-Anwendungen müssen Strom-
wandler vor dem Betrieb angeschlossen sein.
i
* Attention! In UL applications, current transfor-
mers must be connected before operation.
≠ 8 >1.5
81.5
81.5
≠ 8 >1.5
81.5
81.5
≠ 8
>1.5
81.5
81.5
i
Ab 0,75 mm² nur Crimpzange ähnlich CRIMPFOX 6
oder Weidmüller PZ6/PZ6/5 verwenden.
i
From 0.75 mm², use crimping pliers similar to
CRIMPFOX 6 or Weidmüller PZ6/PZ6/5 only.
RCM410R-24/-2
i
*
2 RCM410R_D00403_02_Q_DEEN /07.2022
LINETRAXX® RCM410R-24/-2
i
If no entry is made for a period of 5 minutes, the
Addr. mode is automatically exited. The device then
adopts the currently set Modbus address.
Betriebsmodus ON / operating mode ON (Standard)
ON
Bender
RCM410R
T / R
ton(s)
Ext 10 42
1
0,8
0,6
0,40,20
I∆n(A)
Ext 30 10 5
1
0,5
0,3
0,1,03,01
25
%
50
75
%
100
2
AL
1
S2S1
**
A2A2
A1A1
11 14 12
BA-+
1
2
3
4
5
6
7
9
8
Nr. No. Funktion / Function Bemerkung / Description
1 Kein Alarm / No alarm Gerät im Normalzustand / Device in normal condition
2IΔn ≥25% Fehlerstrom erkannt / Fault current detected
3IΔn ≥50% & AL1 (Vorwarnung / prewarning) Vorwarnung ausgelöst / Prewarning triggered
4IΔn ≥75% & AL1 (Vorwarnung / prewarning) Vorwarnung ausgelöst / Prewarning triggered
5IΔn ≥100% & AL1 & AL2
(Hauptalarm / main alarm)
Alarmrelais ist angezogen / Alarm relay is energised
6 Alarmhistorie / Alarm history Ein Fehler bestand / A fault existed
7 Anschlussfehler Messstromwandler/
Connection error CT
Fehlerbehebung bzw. Service erforderlich /
Troubleshooting or service required
8 Gerätefehler / Device error Das Gerät ist defekt /The device is defective.
9 NFC aktiv / NFC active NFC ist aktiviert ⁄ NFC is activated
i
Wenn für den Zeitraum von 5 Minuten keine Eingabe
erfolgt, wird der Addr.-Modus automatisch verlas-
sen. Das Gerät übernimmt dann die aktuell einge-
stellte Modbus-Adresse.
T/R Funktionen / T/R functions (Konfiguration / configuration)
Übersicht / Overview
Addr.-Modus: Adressierung / Addr. mode: address setting
Modbus Adressen Eingabe mittels BCD-Code / Modbus address input via BCD
ON Reset Test NFCactive/inactive Addr. ON
T / R
1 s 3 s 6 s 10 s 15 s
25%
50%
75%
100%
AL2
AL1
…
0 94321 …
25%
50%
75%
100%
AL2
AL1
…
090403020
10 …
25%
50%
75%
100%
AL2
AL1
0200
100
T / R
T / R
x [0…2]
T / R
2s
T / R
x [0…9]
T / R
2s
T / R
x [0…9]
T / R
2s
ONAddr.
LINETRAXX® RCM410R-24/-2
RCM410R_D00403_02_Q_DEEN /07.2022 3
Technical data
Supply voltage
RCM410R-24
Supply voltage Us....................................................................DC 24 V
Tolerance Us...................................................................-30…+25 %
Power consumption.................................................................. ≤ 2 W
RCM410R-2
Supply voltage Us............................AC/DC 100…240 V (47…63 Hz)
Tolerance Us.............................................................................±15 %
Power consumption.................................................≤ 2 W / ≤ 3.5 VA
Measuring circuit
Measuring current transf. type ...........................................................
..............................................CTAC…, W…, WF…*, WR…, WS…
* Can only be used when CT connection monitoring is disabled on the
RCM410R.
Load.............................................................................................33 Ω
Operating characteristics ..........................................................Type A
Rated voltage Un..........see datasheet measuring current transformer
Frequency range..............................................................42…70 Hz)
Measuring range RMS.....................................................2 mA…50 A
Residual operating current IΔn......................................10 mA…30 A
Operating uncertainty...................................±10 % (at 0.5…5 x IΔn)
Relative uncertainty.......................................................... 0…–20 %
Contact data acc. to IEC 60947-5-1:
Utilisation category..................AC 13 / AC 14 / DC-12 / DC-12 / DC-12
Rated op. voltage........................ 230 V / 230 V / 24 V / 110 V / 220 V
Rated op. current....................................5 A / 3 A / 1 A / 0.2 A / 0.1 A
Minimum contact rating................................1 mA at AC/DC ≥ 10 V *
* refers to relays that have not been operated with high contact currents.
Connection
Connection type...................................................................... push-in
Connection properties
rigid ................................................... 0.2…1.5 mm² (AWG 24…16)
flexible without ferrule...................... 0.2…1.5 mm² (AWG 24…16)
flexible with ferrule and plastic ferrule......................0.2…0.75 mm²
flexible with ferrule without plastic ferrule .............0.2…1.5 mm² *
* > 0.75 mm² use crimping pliers simlar CRIMPFOX 6 / Weidmüller PZ6/PZ6/5
only.
Technische Daten
Versorgungsspannung
RCM410R-24:
Versorgungsspannung Us........................................................DC 24 V
Toleranz von Us..............................................................-30…+25 %
Eigenverbrauch.........................................................................≤ 2 W
RCM410R-2:
Versorgungsspannung Us................AC/DC 100…240 V (47…63 Hz)
Toleranz von Us........................................................................±15 %
Eigenverbrauch....................................................... ≤ 2 W / ≤ 3,5 VA
Messkreis
Messstromwandlertyp........................................................................
..............................................CTAC…, W…, WF…*, WR…, WS…
* Einsatz nur bei deaktivierter Messstromwandler-Anschlussüberwachung am
RCM410R möglich.
Bürde...........................................................................................33 Ω
Ansprech-Charakteristik............................................................. Typ A
Bemessungsspannung Un...........siehe Datenblatt Messstromwandler
Frequenzbereich ............................................................... 42…70 Hz
Messbereich RMS............................................................2 mA…50 A
Ansprechdifferenzstrom IΔn...........................................10 mA…30 A
Betriebsmessabweichung...........................±10 % (bei 0,5…5 x IΔn)
Prozentuale Ansprechunsicherheit ................................... 0…–20 %
Kontaktdaten nach IEC 60947-5-1:
Gebrauchskategorie.................AC 13 / AC 14 / DC-12 / DC-12 / DC-12
Bem.betriebsspannung............... 230 V / 230 V / 24 V / 110 V / 220 V
Bem.betriebsstrom.................................5 A / 3 A / 1 A / 0,2 A / 0,1 A
Min. Kontaktbelastbarkeit ...........................1 mA bei AC/DC ≥ 10 V *
* bezieht sich auf Relais, die noch nicht mit hohen Kontaktströmen betrieben
wurden
Anschluss
Anschlussart............................................................................Push-In
Anschlussvermögen
starr .................................................. 0,2…1,5 mm² (AWG 24…16)
flexibel ohne Aderendhülse............... 0,2…1,5 mm² (AWG 24…16)
flexibel mit Aderendhülse und Plastikhülse...............0,2…0,75 mm²
flexibel mit Aderendhülse ohne Plastikhülse............0,2…1,5 mm² *
* > 0,75 mm² nur Crimpzange ähnlich CRIMPFOX 6 / Weidmüller PZ6/PZ6/5
verwenden.
LINETRAXX® RCM410R-24/-2
Alle Rechte vorbehalten.
Nachdruck und Vervielfältigung
nur mit Genehmigung des Herausgebers.
Bender GmbH & Co. KG
Postfach 1161 • 35301 Grünberg • Deutschland
Londorfer Str. 65 • 35305 Grünberg • Deutschland
Tel.: +49 6401 807-0 • Fax: +49 6401 807-259
E-Mail: [email protected] • www.bender.de
All rights reserved.
Reprinting and duplicating
only with permission of the publisher.
Bender GmbH & Co. KG
PO Box 1161 • 35301 Grünberg • Germany
Londorfer Str. 65 • 35305 Grünberg • Germany
Tel.: +49 6401 807-0 • Fax: +49 6401 807-259
E-Mail: [email protected] • www.bender.de

This manual suits for next models

1

Other Bender Measuring Instrument manuals

Bender PEM353 User manual

Bender

Bender PEM353 User manual

Bender LINETRAXX PEM555 User manual

Bender

Bender LINETRAXX PEM555 User manual

Bender MRCDB423 Series User manual

Bender

Bender MRCDB423 Series User manual

Bender LINETRAXX RCM410R-1 User manual

Bender

Bender LINETRAXX RCM410R-1 User manual

Bender EDS44-CN Series User manual

Bender

Bender EDS44-CN Series User manual

Bender VME420 User manual

Bender

Bender VME420 User manual

Bender grass valley KMX-4911 User manual

Bender

Bender grass valley KMX-4911 User manual

Bender NGRM700 User manual

Bender

Bender NGRM700 User manual

Bender ISOMETER isoCHA425HV User manual

Bender

Bender ISOMETER isoCHA425HV User manual

Bender VMD423-D-1 User manual

Bender

Bender VMD423-D-1 User manual

Bender RCMA426H User manual

Bender

Bender RCMA426H User manual

Bender ISOMETER IR420-D6 User manual

Bender

Bender ISOMETER IR420-D6 User manual

Bender ISOMETER isoPV with AGH-PV User manual

Bender

Bender ISOMETER isoPV with AGH-PV User manual

Bender ISOMETER isoCHA425HV User manual

Bender

Bender ISOMETER isoCHA425HV User manual

Bender ISOMETER isoGEN423-D4-4 User manual

Bender

Bender ISOMETER isoGEN423-D4-4 User manual

Bender COMTRAXX MK800 User manual

Bender

Bender COMTRAXX MK800 User manual

Bender Isometer IR420-D4 User manual

Bender

Bender Isometer IR420-D4 User manual

Bender RC48N-70-10 A User manual

Bender

Bender RC48N-70-10 A User manual

Bender RDC104-4 User manual

Bender

Bender RDC104-4 User manual

Bender LINETRAXX PEM575 Series User manual

Bender

Bender LINETRAXX PEM575 Series User manual

Bender A-ISOMETER IRDH275 User manual

Bender

Bender A-ISOMETER IRDH275 User manual

Bender ISOMETER iso685-D-P User manual

Bender

Bender ISOMETER iso685-D-P User manual

Bender ISOMETER isoPV425 with AGH420 User manual

Bender

Bender ISOMETER isoPV425 with AGH420 User manual

Bender ISOMETER isoHV525-M4-4 User manual

Bender

Bender ISOMETER isoHV525-M4-4 User manual

Popular Measuring Instrument manuals by other brands

ABB 4690 Series Upgrade Procedure

ABB

ABB 4690 Series Upgrade Procedure

Steradian Classic Series user guide

Steradian

Steradian Classic Series user guide

PCB Piezotronics IMI SENSORS 603M113/ICS-1 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 603M113/ICS-1 Installation and operating manual

GDS GasVac 311 Operating handbook

GDS

GDS GasVac 311 Operating handbook

Test Equipment Depot IDEAL 700 Series quick start guide

Test Equipment Depot

Test Equipment Depot IDEAL 700 Series quick start guide

Tenma 72-7935 operating manual

Tenma

Tenma 72-7935 operating manual

McCrometer Mc Mag3000 Installation, operation and maintenance manual

McCrometer

McCrometer Mc Mag3000 Installation, operation and maintenance manual

Hilti PD-I manual

Hilti

Hilti PD-I manual

Sensus PolluStat E Installation and operating instructions

Sensus

Sensus PolluStat E Installation and operating instructions

Phonic PAA3 user manual

Phonic

Phonic PAA3 user manual

IBR IMB-pc1 instruction manual

IBR

IBR IMB-pc1 instruction manual

Hanna Instruments HI 96759C instruction manual

Hanna Instruments

Hanna Instruments HI 96759C instruction manual

Endress+Hauser Micropilot FMR60 Safety instructions

Endress+Hauser

Endress+Hauser Micropilot FMR60 Safety instructions

Labgear SQ722 Setup instructions

Labgear

Labgear SQ722 Setup instructions

Measure-Quip AAVM-318 instruction manual

Measure-Quip

Measure-Quip AAVM-318 instruction manual

Kewtech KTD30 user manual

Kewtech

Kewtech KTD30 user manual

Victor VC60B+ instruction manual

Victor

Victor VC60B+ instruction manual

YOKOGAWA EXA TB TB400G user manual

YOKOGAWA

YOKOGAWA EXA TB TB400G user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.