Blankom AMB 307 User manual

Professional Headend Solutions
Operating instructions
Contents
1. Safety and operating instructions ...................................................................2
2. Device variants ................................................................................................2
3. General ............................................................................................................2
4. Front view ........................................................................................................3
5. Functional description......................................................................................3
6. Adjustments ........ ............................................................................................3
6.1 Adjustment with the Headend Controller ..................................................3
6.2 Adjustment with PC/ laptop.......................................................................3
6.3 Adjustment with SNMP..............................................................................4
7. Meaning of LED signals ...................................................................................4
7.1 LED‘s for the ASI ports ..............................................................................4
7.2 Status LED‘s .............................................................................................4
8. Programming by web server............................................................................5
8.1 Main menu ................................................................................................5
8.2 Extended settings .....................................................................................6
8.3 NIT entries ... .............................................................................................6
8.4 Program filter ............................................................................................6
8.5 Data rate overview ....................................................................................6
8.6 Table processing ......................................................................................7
8.7 Configuration channel list-LCN .................................................................7
8.8 Software overview .....................................................................................8
8.9 Device status ............................................................................................9
8.10 Factory settings ......................................................................................9
9. Manual menu control with Headend Controller ............................................. 10
10. SNMP Trap messages .................................................................................10
11. Block diagram .. ........................................................................................... 11
12. Head end bus structure ...............................................................................11
13. Application example ....................................................................................12
14. Technical data ... .......................................................................................... 12
15. Glossary ........... ...........................................................................................13
16. Bibliography ..... ...........................................................................................13
17. Document history ........................................................................................13
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)

2
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)
B
LINE
1. Safety and operating instructions
When assembling, starting-up and adjusting the modules, it is necessary to consider the system specific references in
the manual instruction.
The modules may only be installed and started up by authorized technical personnel.
When assembling the modules into the receiving points, the adherence of the EMC regulations is to be secured.
The assembly and wiring have to be done without voltage.
All active modules may only be operated with the Headend Controller HCB x00 or Bus Extender BEB x00.
The main voltage and the operating voltage of the modules working by DC have to be in complience to the operating
parameters described in the technical data.
With all work the defaults of the DIN EN 50083 have to be considered! Especially the safety
relevant execution of the DIN EN 60728-11[2] is necessary.
2. Device variants
AMB 307 9730.01 ASI-TS →DVB-T (COFDM)
Mininum software requirements for HCB x00:
9650.03: Version 2.34*
9650.04/.05: Version 3.18*
9652.01: Version 3.23*
9653.01: Version 3.27*
9653.02: Version 3.28*
*) Updates: www.blankom.de
3. General
The COFDM modulator AMB 307 is a module of the head end system B-LINE wich is conceived as a complete system for middle-
sized networks.The module converts one (or two, if hierarchical modulation selected) ASI stream(s) into the digital standard
DVB-T. The signal will be transcoded from the ASI transport stream into cable TV channels. All modules will be programmed via
a central control unit (HCB x00) and are working fully independent afterwards. The status of the modules are displayed via LED’s
(see chapter 7.2 “Status LED‘s“).
WEEE-Reg.-Nr. DE 50389067

3
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)
B
LINE
The manual instructions of the Headend Controller HCB x00 and the Bus Extender BEB x00 have to be considered!
4. Front view
5. Functional description
The data stream which results from the ASI input is passed to a FIFO. All services of the resulting transport stream which shall be pro-
cessed into the COFDM modulator will be choosen by controling software of the module. The SI and PSI tables affected (i.e. the PAT,
PMT, SDT, EIT) are automatically corrected. From the Headend Controller informations are provides to generate a complete NIT (Net-
work Information Table) into the transport stream. This is required to enable the receiver (such as set-top-box) to tune in automatically.
The changed SI an PSI tables are fed into the COFDM modulator and an IF signal is generated at the output channel. There is a free
choise of frequency in the output channel from 45 to 862 MHz. On the output side, the modulator does not leak to adjacent channels.
So that errors in level can be signalled if the load fluctuates (the red LED will flash and a trap message will be sent), a reference level
is generated. Every time the level for frequency figures are programmed, automatic measurement of the refence level takes place; this
function will, however, not start until 100 seconds have elapsed after start-up of the system. This function can be enabled or disabled
in the main menu.
6. Adjustments
6.1 Adjustment with the Headend Controller
· Adjustment of the addresses at the Bus Extender BEB x00 and at the modules
· Activation of the programming mode on each module by selecting the line (BEB x00) and the module position (01... 15) at the
Headend Controller(HCB x00)
→ yellow LED illuminates until the beginning of the parameter adjustment
· Adjustment of the AMB 307 parameters (see chapter 9) →green LED is switched on
· After the programming the AMB 307 will be automatically switched into the operating mode
→yellow LED flashes shortly/ green LED is switched on
6.2 Adjustment with PC/ laptop
· Prerequisite for the remote programming is an “online-connection” acording the IP standard and an ethernet connection at the
PC/ laptop
· Adjustment of the line/ position addresses at the Bus Extender BEB x00 as well as at the modules
· At the Headend Controller HCB x00 input IP address (default: 192.168.2.80)
· For “direct connection” between a PC and HCB x00 use crossover cable (RJ 45)
· For connection over a hub use a normal straight throught patch cable
· Start-up HTML browser and put in IP address as target address
· If connected correctly the web interface will be opened on the PC/ laptop and a blue LED (LINK) at the HCB x00 will be lit up.
· All adjustments of the modules are specified on the web interface.
COFDM MODULATOR
ASI-TS DVB-T(COFDM)
ASI/ TS-MODE burst,continuous 188,204
ASI/ TS-RATE 270/ 0.625...78 Mbps
INPUT LEVEL 200...880 mV
TV-RF OUT 45...862 MHz
OUTPUT LEVEL max. 155 dBµV
SUPPL CURRENT 0.65 A
Type: Part N :AMB 307 9730.01
o
pp
COFDM MODULATOR
AMB 307 9730.01
ASI-TS DVB-T(COFDM)
ASI/ TS-MODE burst,continuous 188,204
ASI/ TS-RATE 270/ 0.625...78 Mbps
INPUT LEVEL 200...880 mV
TV-RF OUT 45...862 MHz
OUTPUT LEVEL max. 155 dBµV
SUPPL CURRENT 0.65 A
Type: Part N :
o
pp
X1
ASI
IN/OUT
ASI TS input 1
LED input 1
ASI TS input 2/ output
LED input 2/ output
Operating voltage/
control bus
LED “STANDBY (red)
LED “READY“ (green)
LED “ADDR.“ (yellow)
Address selector
RF output

4
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)
B
LINE
6.3 Adjustment with SNMP
· Prerequisite for the SNMP functionality is the use of HCB x00 with enabled SNMP software option CKB 100.
· Supported is SNMP version 1.0 [2].
· Automatic creation of the MIB based on the current head end configuration by the HCB x00.
· For setting and reading out the parameters and is to receive traps from an SNMP management software required.
· Further notes on the SNMP functionality of BLANKOM modules are listed in the SNMP manual (download: www.blankom.de).
7. Meaning of LED signals
7.1 LED’s for the ASI ports
Colour Status Meaning of display
green permanently on ASI channel has been configured as input
flashing no ASI signal
yellow permanently on ASI channel has been configured as output
flashing no ASI signal
7.2 Status LED‘s
Designation (Colour) Status Meaning of display
STANDBY (red) permanently on Module is on standby
flashing Module faulty (hardware) or level error
READY (green) permanently on Module working, everything ok
flashing Dysfunction depending in signal:
ASI not sync (e.g. in case of missing input signal)
no input on the COFDM modulator
buffer overflow in the COFDM modulator
off RF output is deactivated
ADDR. (yellow) illuminated or flashing Remote control making contact/ data transmission

5
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)
B
LINE
8. Programming by web server *
8.1 Main menu
Name of device, item number, module address in head end
Description module name (max. 30 characters)
Transport stream displays the priority of both TS, if hierarchical
modulation was selected (menu 1)
Input
TS-Input displays ASI input respective selection of the
input of the second TS, if hierarch. modulation
was selected.
Status display wether SYNChronization or
noSYNChronisation with input
Data rate displays the data rate of the TS
Output
Channel channel selection : 2 ... 69, standard B/G,
2 ...134, standard M
Attenuation adjustment range 0 ... 31.5 dB
RF signal: selection: On/ Off
Transmission mode selection: 2k/ 8k
Constellation selection: 16 QAM, 64 QAM, QPSK
Bandwith: selection: 5, 6, 7, 8 MHz
Guard intervall: selection: 1/32, 1/16, 1/8, 1/4
Code rate: selection: 1/2, 2/3, 3/4, 5/6, 7/8
Status
Operating mode
COFDM-Modulator according adjustment menu 1
Hierarchical
modulation according adjustment menu 1
Mode TS-Processing DVB-Standard/ TNT-France according menu 1
NIT-Processing On/ Off according adjustment menu 5
CAT-Processing On/ Off according adjustment menu 5
Change TS-Identificat. On/ Off according adjustment menu 5
Program filter On/ Off according adjustment menu 3
Data rate overview see menu 4
Operating mode selection: On/ Off/ Reset
SNMP-Trap message selection: On/ Off, if SNMP option in HCBx00
enabled, otherwise “locked“ displays
Level monitoring selection: On/ Off
Factory settings setting the default values (see menu 9)
Routing to the appropriate adjustment menu
Extended settings see menu 1
NIT table see menu 2
Program filter see menu 3
Table processing see menu 5
Software overview see menu 7
Status see menu 8
* Further details on this are to be found in the HCB manual

6
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)
B
LINE
8.2 Extended settings (menu 1)
Name of device, item number, module address in head end
Output
Standard (channel
table) selection: B/G, M
Frequency adjustment range 45000 ... 862000 kHz
Operating mode selection: Transcoder, Test level,
COFDM-Modulator Test signal
Hierarchical selectionl: Off, On (Alpha=1), On (Alpha=2),
modulation On (Alpha=4)
Spectrum selection: normal/ invers
Mode TS-Processing selection: DVB-Standard, TNT-France
8.3 NIT entries (menu 2)
Name of device, item number, module address in head end
NIT entries with all information available
8.4 Program filter (menu 3)
Name of device, item number, module address in head end
Program filter configuration
Filter function selection: On/ Off
Other transporder
information pass or drop of additional informations
(e.g. electronic program guide), wich are
contained in data stream as “other“
Program selection
Operating mode pass or drop of the marked programs
Reserve selection all not marked programs are choosen
or vice versa
Select all all programs of the list are marked
Clear all no program of the list is marked
Data rate overview routing to menu 4
8.5 Data rate overview (menu 4)
Name of device, item number, module address in head end
Input data rate net data rate at the input
Data rate by filter net data rate by program filters
Available netto data rate max. possible net data rate
Reserve max. netto data rate minus
data rate by filter
FIFO-Memory utilisation displays in %

7
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)
B
LINE
8.6 Table processing (menu 5)
Name of device, item number, module address in head end
Transport stream displays the priority of both TS, if hierarchical
modulation was selected (menu 1)
NIT
NIT-Processing selection: On/ Off
Network name adjustment range: max. 30 characters
Network ID adjustment range: 0...65535
Channel number
insertion (LCN) selection: On/ Off
Standard SD-LCN IEC 62216, NorDig(V1)
Channel list see menu 6
CAT
CAT-Processing selection: On, On (CA Filter), Off
CA-System ID adjustment range: 0...65535
Operator ID adjustment range: 0...65535
Transport stream
Change TS-Identific. selection: On/ Off
Transport stream ID adjustment range: 0...65535
Network ID adjustment range: 0...65535
8.7 Configuration channel list-LCN (menu 6)
Name of device, item number, module address in head end
The allocation of a logical channel number (LCN) is a service that allocates
a serial number to each TV activated program. If the set-top box supports
this service at the subscriber, the TV programs are offered in the
order established by program numbers. It should be noted that the num-
bering is done separately for HD and SD programs for the respective type
of the box. The simultaneous activation and number allocation for SD pro-
grams in the HD column provides such programs to the appropriate
channel number in the program list for HD boxes.

8
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)
B
LINE
8.8 Software overview (menu 7)
Name of device, item number, module address in head end
Software version
Controller of terminals board
FPGA Bootcontroller
COFDM modulator, TS-Mux (FPGA)
TS manager
ASI Bootcontroller
ASI FPGA
Up Convertrer controller

9
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)
B
LINE
8.9 Device status (menu 8)
Name of device, item number, module address in head end
Input
TS-Input displays 1 or 2 inputs acc. selected configuration
Status SYNChroninsation or noSYNChronisation with
ASI input
Data rate displays data rate of TS
Packet size size of packets (188/ 204) in byte
FPGA Status status, transport stream input
FPGA-Error memory error memory TS Mux, COFDM Mod.
Up Converter error
memory error memory up converter
Original TS-ID’s display transport stream ID and network ID
Information
Temperature Temperature of terminals board
Device number display of the device number
Device index display of the device index (hardware)
8.10 Factory settings (menu 9)
When request this menu item at first a security query whether it really set
all parameters to the factory default settings pops up.
Affirming the query, all settings made on the EEPROM will be deleted and
replaced by the default settings. The modul will go back to these default
values. Once the setting process is over, there will be automatic return to
the main menu. It takes about one minute.

10
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)
B
LINE
9. Manual menu control with Headend Controller (HCB x00)
10. SNMP Trap messages
Item Message Message type Explanation
01 Power fail CRITICAL short circuit
02 System Reset WARNING reset by internal error
03 Input OK INFORMATION module works correctly
04 Input not sync WARNING no ASI input signal
05 IIC error CRITICAL IIC-Bus-error
06 TS-MUX not sync WARNING no transport stream at the FPGA
07 Internal controller reset WARNING error when accessing internal controller
08 FPGA: Program memory full WARNING overflow of program memory in the FPGA
09 FPGA: PID memory full WARNING overflow of PID memory in the FPGA
10 FPGA: Directory full WARNING overflow of Directory in the FPGA
11 FPGA: FAT memory full WARNING overflow of FAT memory in the FPGA
12 FPGA: TS-Packed buffer overflow WARNING overflow of TS packet buffer
13 Data overflow CRITICAL overflow of data
14 Sync error data FIFO CRITICAL data FIFO doesn’t work correctly
15 No response to OPEN command CRITICAL error internal port
16 FPGA ok INFORMATION data processing in FPGA is ok
AMB 307 start
Edit or End
Power Status On/ Off
Output
Output frequency 45000 ... 862000 kHz
Attenuation 0 ... 31.5 dB
RF output On/ Off
Level monitoring On/ Off
Modulator Mode Transcoder/ Test signal/ Test level
Spectrum normal/ invers
Hierarch. modulation Off/ On(Alpha=1)/
On(Alpha=2)/ On(Alpha=4)
Transmission 2k/ 8k
Constellation 16 QAM/ 64 QAM/ QPSK/
Bandwith 5/ 6/ 7/ 8 MHz
Guard interval 1/32, 1/16, 1/8, 1/4
PID program filtering
Program filter On/ Off
Mode Pass/ Drop
Other TS-Data Pass/ Drop
Table processing
NIT processing On/ Off
Network name max. 30 characters
Network ID 0...65535
CAT processing On/ On (CA Filter)/ Off
CA System ID 0...65535
Operator ID 0...65535
Change TS ID On/ Off
TS Network ID 0...65535
TS ID 0...65535
Channel name
AMB 307 end

11
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)
B
LINE
Item Message Message type Explanation
17 Up Converter: PLL1 not locked CRITICAL no funktion at the PLL 1 converter
18 Up Converter: PLL2 not locked CRITICAL no funktion at the PLL 2 converter
19 Up Converter: IF input too small WARNING IF input too small at the Up converter
20 Up Converter: IF input too large WARNING IF input too large at the Up converter
21 Up Converter: RF output too small WARNING RF output too small at the Up converter
22 Up Converter: RF output too large WARNING RF output too large at the Up converter
23 Up Converter ok INFORMATION Up converter works correctly
11. Block diagram
12. Head end bus structure
ASI
frontend
PID
filter
PID
filter
multiplexer
with
PCR correct.
multiplexer
with
PCR correct.
SI/ PSI
processor
flash
SDRAM
COFDM
modulator
BP
IF
RF
D
A
TS
TS
TS
TS
TS
TS
CTRL
CTRL
SI/ PSI
data
SI/ PSI
data
clock
RF
ASI
clock
HCB x00
Headend
Controller
BEB x00
Bus Extender
Module
signal processing
unit
HCB x00
Module
ADDR. 15
BEB x00
ADDR. 01
BEB x00
ADDR. 02
BEB x00
ADDR. 15
Module
ADDR. 01
Module
ADDR. 01
Module
ADDR. 01
Module
ADDR. 15
Module
ADDR. 15
The number of the possible module connections (01 ... 15) to a
BEB x00 depends on the total power consumption of this line!

12
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)
B
LINE
13. Application example
14. Technical data
ASI input
Level range 200 … 880 mVpp
System clock 270 Mbps
Connector BNC socket
Impedance 75 Ω
ASI polarity regular/ inverted
ASI output
Level 800 mVpp (± 10 %)
System clock 270 Mbps
Connector BNC socket
Impedance 75 Ω
ASI polarity regular
ASI signal processing
Data rate 0.625…213 Mbps
ASI transfer format
Input continuous, burst
Output burst
TS transfer format
Input 188, 204 Byte
Output 188, 204 Byte
Signal processing EN 50083-9 [1]
COFDM modulator
Transmission mode 2k, 8k
Guard interval 1/4, 1/8, 1/16, 1/32
Constellation 1/2, 2/3, 3/4, 5/6, 7/8
Hierarchical modulation QPSK, 16 QAM, 64 QAM
Hierarchical protect mode Alpha 1, 2, 4
Bandwith 5, 6, 7, 8 MHz
RF output
Output frequency range 45 ... 862 MHz
Tuning step 10 kHz
Max. output level 115 dBµV
Level adjustment range 0 ... 31.5 dB (0.5 dB steps)
Channel allocation adjacent channel ability
Connector F socket
Impedance 75 Ω
Return loss ≥ 18 dB 45 MHz
- 1.5 dB/ Octave
Signal quality
MER ≥ 43 dB
Shoulder attenuation ≥ 58 dB
Spurious 45...862 MHz ≥ 60 dB
C/N (> 25 MHz space from channel center)
BW = 5 MHz typ. 80 dB
BW = 8 MHz typ. 78 dB
Phase noise 1 kHz; typ. -92 dBc/ Hz
10 kHz; typ. -101 dBc/ Hz
100 kHz; typ. -108 dBc/ Hz
max. frequency stability ± 30 kHz
Output level stability ± 0.5 dB
Amplitude frequency
response channel (8 MHz) max. 1 dBpp
Operating parameters
Voltage/ current 12 V (0.2 V)/ max. 650 mA
Residual ripple of the supply
voltage ≤ 10 mVPP
Enviromental conditions
Temperature range -10 ... +55 °C
Temperature range
for data keeping 5 ... 45 °C
Relative humidity ≤ 80 % (non condensing)
Mounting method vertical
Mounting location splash-proof
and drip-proof
Physical information
Dimensions (w x h x d)
without 19” adapter 50 x 276 x 148 mm
with 19” adapter 50 x 301 x 148 mm
Weight 1,190 g
Delivery content 1x Bus connector

13
AMB 307
Part No: 9730.01
COFDM Modulator
ASI-TS →DVB-T (COFDM)
B
LINE
15. Glossary
ASI ......................................................... Asynchronous Serial Interface
AP .......................................................... Anschlussplatte (front circuit board)
BW ......................................................... Bandwidth
CA .......................................................... Conditional Access
CAT ........................................................ Conditional Access Table
COFDM ................................................. Coded Orthogonal Frequency Division Multiplex
DVB........................................................ Digital Video Broadcasting (-C Cable, -S Satellite, -S2 Satellite 2, -T Terrestrial)
EIT.......................................................... Event Information Table
ETSI ....................................................... European Telecommunications Standards Institute
FAT......................................................... File Allocation Table
FEC ........................................................ Forward Error Correction
FIFO ...................................................... First In–First Out
FPGA...................................................... Field Programmable Gate Array
HTML .................................................... Hypertext Markup Language
HTTP ..................................................... Hypertext Transfer Protocol
I/Q .......................................................... In-phase/Quadrature-phase
ID............................................................ Identifier
IF ............................................................ Intermediate Frequency
IIC........................................................... Inter-Integrated Circuit (I²C-Bus, data bus within device)
IP............................................................ Internet Protocol
LED ........................................................ Light Emitting Diode
MAC ....................................................... Media Access Control
MER ....................................................... Modulation Error Ratio
MIB......................................................... Management Information Base
MPEG..................................................... Moving Picture Experts Group
NIM ........................................................ Network Interface Module
Nios........................................................ product name for a processor
NIT ......................................................... Network Information Table
PAT......................................................... Program Association Table
PCR........................................................ Program Clock Reference
PID ......................................................... Program Identifier
PMT........................................................ Program Map Table
PSI ......................................................... Program Service Information
QAM ....................................................... Quadrature Amplitude Modulation
QPSK ..................................................... Quadrature Phase Shift Keying
RF .......................................................... Radio Frequency
SDT ........................................................ Service Description Table
SI............................................................ Service Information
SNMP..................................................... Single Network Management Protocol
TS........................................................... Transport stream
16. Bibliography
[1] EN 50083-9: Cabled distribution systems for television, sound and interactive multimedia signals, part 9: Interfaces
for CATV/ SMATV head ends and similar professional equipment for DVB/ MPEG-2 transport streams
[2] EN 60728-11: Cable networks for television signals, sound signals and interactive services Part 11: Safety
(IEC 60728-11:2005); German version EN 60728-11:2005
[3] RFC 1157 Request for Comments (RFC): RFC Database URL: http://www.rfc-editor.org/rfc.html
[4] EN 50083-2 : Cabled distribution systems for television and sound signals. Electromagnetic compatibility for equipment;
EN 50083-2:2001
17. Document history
Version Date Modification Author
1.00 25.07.2009 basic dokument Häußer
1.01 13.04.2011 revision Häußer
1.02 09.02.2012 revision web sites (LCN) Häußer
Options and other TV standards available upon request! Subjects to changes due to technical progress.
BLANKOM Antennentechnik GmbH
Hermann-Petersilge-Straße 1 • 07422 Bad Blankenburg • Germany • Phone +49 (0) 3 67 41 / 60-0 • Fax +49 (0) 3 67 41 / 60-100

14
Declaration of Conformity
The Manufacturer
BLANKOM Antennentechnik GmbH ∙ Hermann-Petersilge-Str. 1 ∙ 07422 Bad Blankenburg ∙ Germany
herewith declares the conformity of the product
Product name: COFDM Modulator
Type: AMB 307
Product number: 9730.01
according to the following regulations
EN 50083-2
EN 60728-11 (as far as relevant)
and additional device-specific regulations, enclosed above, which this product is subjected to.
Date: 25.07.2009
Signature:
(Managing Director)
Table of contents
Other Blankom Modulator manuals

Blankom
Blankom VMA 191 User manual

Blankom
Blankom 5105.82 User manual

Blankom
Blankom HDC 5016 User manual

Blankom
Blankom AMA 299 Application guide

Blankom
Blankom HDC 5016 User manual

Blankom
Blankom HDC 7016 Instruction Manual

Blankom
Blankom QAMOS-CT Application guide

Blankom
Blankom A-QAMOS-4CI Application guide

Blankom
Blankom A-PALIOS-IPM4 User manual

Blankom
Blankom HDC 6012 User manual

Blankom
Blankom STR 821 User manual

Blankom
Blankom HDC 6008CI User manual

Blankom
Blankom ATB 19 series User manual

Blankom
Blankom VMB 195 User manual

Blankom
Blankom PALIOS-IPM4 5105.10 User manual

Blankom
Blankom SAT-TV User manual

Blankom
Blankom PALIOS-IPM2 User manual

Blankom
Blankom A-PALIOS-IPM4CI 5113.81 User manual