www.blaubergventilatoren.de
3
Tower-V / Tower-H / Tower-V EC / Tower-H EC
BLAUBERG Ventilatoren GmbH is happy to oer your attention the Tower-
V(H) / Tower-V(H) EC centrifugal roof fan.
INTRODUCTION
The present operation manual contains a technical description, technical
data sheets, operation and mounting guidelines, safety precautions and
warnings for safe and correct operation of the fan.
Read carefully and understand the operation manual, especially the safety
requirements, before the unit mounting and start up.
Keep the operation manual available as long as you use the unit.
GENERAL
The Tower-V(H) / Tower-V(H) EC centrifugal roof fans are designed for
exhaust ventilation of various premises. The fan is suitable for vertical
mounting on the exhaust ventilation shaft of the air duct.
The fan is not a ready to use product but a component part of a ventilation
network.
The fan is allowed for operation only after nal mounting that includes
installation of protecting devices in compliance with DIN EN ISO 13875 (DIN
EN ISO 12100) as well as other construction safety equipment.
Design of the fans is regularly improved, so some models can slightly
dier from those ones described in this operation manual.
SAFETY REGULATIONS
All operations related to the unit electrical connections, servicing and repair
works are allowed only after the unit is disconnected from power supply.
The unit is rated as a Class I electrical appliance.
All mounting and servicing operations must be carried out only by qualied
personnel.
Please follow the safety regulations and working instructions (DIN EN 50
110, IEC 364).
Make sure the impeller and the casing are not damaged before connecting
the unit to power supply. The casing internals must be free of any foreign
objects which can damage the impeller blades or the motor.
The unit maintenance and repair are allowed only after power cut-o and
full stop of the rotating parts.
Misuse of the unit or any unauthorized modications are not allowed.
The unit is designed for connection to power supply in compliance with the
"Technical data" section.
The unit is rated for continuous operation.
Take steps to prevent ingress of smoke, carbon monoxide and other
combustion products into the room through open chimney ues or other
re-protection devices. Sucient air supply must be provided for proper
combustion and exhaust of gases through the chimney of fuel burning
equipment to prevent back drafting. The maximum permitted pressure
dierence per living units is 4 Pa.
The transported air must not contain any dust or other solid impurities,
sticky substances or brous materials.
The unit is not rated for operation in a ammable or explosive medium.
Full the operation manual requirements to ensure a trouble-free and long
service life of the unit.
TRANSPORTATION AND STORAGE REGULATIONS
Transportation of the unit is allowed by any vehicle provided the unit is
transported in the original package and is protected against weather and
mechanical damages.
Use hoist machinery for handling and transportation to prevent possible
mechanical damages of the unit. Full the requirements for transportation of
the specied cargo type.
Store the unit in a dry and cool place in the original packing.
The storage environment must not be subjected to any aggressive and/
or chemical evaporations, admixtures, foreign objects that may provoke
corrosion and damage connection tightness.
Store the unit in an environment with minimized risk of mechanical
damages, temperature and humidity uctuations.
Do not expose the unit to the temperatures below +5 °C and above +40 °C .
Connection of the unit to power supply is allowed after the appliance has
been kept indoors for minimum two hours.
MANUFACTURER'S WARRANTY
The unit complies with the requirements according to the EU norms
and directives, to the relevant EU-Low Voltage Equipment Directives, EU-
Directives on Electromagnetic Compatibility.
We hereby declare that the unit complies with the essential protection
requirements of Electromagnetic Council Directive 2004/108/EC, 89/336/EEC
and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive
93/68/EEC on the approximation of the laws of the Member States relating
to electromagnetic compatibility, which relate to electrical appliances used
in set voltage classes.
The manufacturer hereby warrants normal operation of the unit over
the period of two years from the retail purchase date provided observance
of the installation and operation regulations. In case of a failure due to a
manufacturing fault during the warranty period the consumer has the right
to exchange it.
The replacement is oered by the Seller.
In case of no conrmation of the purchase date, the warranty period is
calculated from the manufacture date.
The MANUFACTURER is not responsible for any damage resulting from
any misuse of or gross mechanical interference with the unit.
The MANUFACTURER is not responsible for the damages resulted due to
the use of third party equipment or to third party equipment.
WARNING
Do not dispose in domestic waste.
The unit contains in part materials
that can be recycled and in part substances that
should not end up as domestic waste.
Dispose of the unit once it has reached the end of
its working life according to the regulations valid in
your country.
WARNING
The unit may not be operated by chil-
dren or persons with reduced physical, mental
or sensory capacities, or lacking the appropriate
training, unless they are controlled or instructed
on the product operation by the person(s) respon-
sible for their safety.
Supervise the children and do not let them play
with the product.