Tecnoalarm TP8-96 User guide

TP8-96 VIDEO
864 ZONES
CONTROL PANEL
8 TO 96 ZONES EXPANDIBLE
CONTROL PANEL
WITH INTEGRATED
ETHERNET SWITCH
EN60950
EN50130-4
EN50081-1
INSTALLER
MANUAL
Release: 1.0
Update: July2011
Language: English
FWversion: 0.7.05

II InstallerManual-TP8-96VIDEO
Theproductfeaturescanbesubjecttochangewithoutnotice.Unauthorizedreproductionordistributionofthis
manual, or any portion of it, on any device and in any form, is prohibited. The contents of this manual may be
subject to change without notice

III
TP8-96VIDEO-InstallerManual
CONFORMITY
Hereby,Tecnoalarm srl declaresthat the presentequipment is incompliance with theessential requirements and
otherrelevantprovisionsoftheR&TTE1999/05/ECdirective.
Thedeclarationofconformityisavailableonthewebsite:www.tecnoalarm.com.

IV InstallerManual-TP8-96VIDEO

TP8-96VIDEO-InstallerManual Index 1
INDEX
1. INTRODUCTION TO THE TP8-96 VIDEO SYSTEM
1.1 PROGRAMMINGMENU 1-1
1.2 HARDWARECONFIGURATION-AVAILABLEMODULES 1-7
2. PROGRAMMING OF ZONES AND PROGRAMS
2.1 ZONECONFIGURATION 2-1
2.1.1 Creationoflistandparameters 2-1
2.1.2 Zone-functionassociation 2-11
2.1.3 Zone-programassociation 2-13
2.1.4 Consoles 2-14
2.1.5 Keypoints 2-16
2.1.6 Options 2-17
2.1.7 Outputs 2-20
2.1.8 Bus sirens 2-22
3. PROGRAMMING OF TELEPHONE SECTION
3.1 TELEPHONEPARAMETERCONFIGURATION 3-1
3.1.1 Telephonechannelsandstandardtelephoneparameters 3-1
3.1.2 GSMmodule 3-4
3.1.3 Tecnocell 3-6
3.1.4 Ethernet 3-8
3.1.5 Teportcodes 3-10
3.1.6 Openingmessage-vocabulary 3-11
3.1.7 Remotecontrols 3-13
3.2 EXPLANATORYNOTES 3-14
3.2.1 Telephonenumbers 3-14
3.2.2 Protocols 3-15
3.2.3 Communicatorblock 3-17
3.2.4 Airtimerequest 3-17
3.2.5 Call-back 3-18
3.2.6 Ethernet 3-20
3.2.7 Remotecontrolmanagement by SMS 3-21
4. PROGRAMMING OF TIME PARAMETERS
4.1 TIMESETTINGS 4-1
4.2 TIMERS 4-3
4.3 ACCESSPERIODS 4-5
4.4 CUSTOMIZATIONOFTHECALENDAR 4-7
4.5 EXPLANATORYNOTES 4-9
5. POGRAMMING OF ACCESS CODES AND KEYS
5.1 PROGRAMMINGOFTHECODES 5-1
5.2 PROGRAMMINGOFTHEKEYS 5-4
5.3 PROGRAMMINGOFTHEWIRELESSKEYS 5-6
5.4 EXPLANATORYNOTES 5-8
6. PROGRAMMINNG OF WIRELESS DEVICES
6.1 PROGRAMMINGOFTHEWIRELESSSIRENS 6-1
6.2 PROGRAMMINGOFTHEWIRELESSCONSOLES 6-3

Index InstallerManual-TP8-96VIDEO
2
7. HARDWARE CONFIGURATION
7.1 ADDITIONORDELETIONOFMODULES 7-1
8. RS485 SERIAL BUS ANALYSIS
8.1 SERIALBUSANALYSIS 8-1
A. APPENDIX A - APPENDIX SPECIAL PROCEDURES
A.1 RESETOFTHEDEFAULTCODES A-3
A.2 COMPLETEDELETIONOFSYSTEMCONFIGURATION(RESETOFDEFAULTSETTINGS) A-4
A.3 BACKUP/RESTOREOFTHECONFIGURATIONOFTHEWIRELESSSECTION A-5
A.4 FIRMWAREUPGRADE A-7
Electronicboard A-11
Terminals A-12
System A-13
Cameraconnection A-14
Supply by terminals A-15
Supply by cables + splitter A-16

TP8-96VIDEO-Installermanual IntroductiontotheTP8-96VIDEOsystem 1-1
1.1 PROGRAMMING MENU
Descriptionoftheprogrammingmenus.
zAdvanced:Enablingordisablingofadvancedprogramminglevel.
N.B.It is possible to enable the advanced programming level only if you are in
possession ofthe corresponding license.
zAutomatic wiring:Enabling or disabling of the automatic wiring function.
N.B. All the other items of the option window are disabled.
zZones: Association of the logical zones to the physical zones, alphanumerical
description, enabling of voice message, zone type, alarm cycles, alarm counter,
contact type, configuration of the connected detector, enter filter and sensitivity
zZones-functions:Association of the followingfunctions to the zones:siren, PGM, by-
pass, coinciding zone, chime, non excludable zone, common zone
zZones-programs:Associationofthezonestotheprograms,alphanumerical
descriptionof theprograms, enabling of the voicemessage
zConsoles:Consoleconfiguration,association of the program statusLEDtothe
programs, quick arming/disarming, panic alarm, quick menu, chime, audio settings,
messagescheduling
zKeypoints:Associationoftheprograms
zOptions: Buzzer section, wireless section, voice report, key zone properties, single
armingmode,enabling/disablingtamper,antimasking control, association of the
siren and PGM outputs to the programs
zOutputs:Outputconfiguration,polarityprogramming
zBus sirens:Associationofthesirenstotheprograms,aftersoundblinking,volume
setting,siren mode, soundtype,functioningmode,enabling/disabling of theantifoam
andantidrillingprotection
PROGRAMMINGOPTIONS
ZONECONFIGURATION
1. INTRODUCTION
PROGRAMMINGOPTIONS

IntroductiontotheTP8-96 VIDEO system Installermanual-TP8-96VIDEO
1-2
TELEPHONE SECTIONCONFIGURATION
zTelephone interface:Programming of the channels from A to H, call back function,
commmunicatorblock,generalsettings
zGSM: Enabling of the GSM interface, answering mode, rings, airtime request, SMS
heading, GPRS settings, commands by SMS, password, white list
zTecnocell:Enablingofthe external GSM communicator, answering mode,emergency
phonenumber,associationofthe messages, emergency SMS, enabling oftheguided
menuandof the data channel
zEthernet:Configurationoftheintegrated 8 ports Ethernet switch,IPaddress, subnet
mask,gateway,programmingofthecommunicationportfortheLocalServer
Tecnoalarm,RemoteServerTecnoalarm,TecnoserverTecnoalarm,Tecno_Out
zReport codes:Programming ofthereportcodesofall8channelsfortheevent
transmission
zOpening message - Vocabulary:Test/recording/loading of the opening message,
loadingandupdateofthevocabulary
zRemotecontrol: Remotecontrolmessage, alphanumericaldescription,
programmingoftheactivationtime
zTime settings: Entry time 1 and 2, exit time, disarming confirmation time, delay of
channelandsirenactivation,antimaskingandpower failure,alarmtime,tamper,
technicalandhold-upalarmtime; duration of end of by-passandautomaticarming
warning,maximumdurationofby-pass,supervisioninterval
zTimers:Frequency and moment of activation, association of the function
zAccessperiods:Frequencyand moment ofactivation,associationoftheaccess
periodstothecodes,transponders/RFIDandremotecontrols
zCustomization 1st year:Programmingofthe working days, holidays andholiday
eves,winterandsummertime,viewingofthescheduledmessageontheconsole
zCustomization 2nd year: Same as for the first year
TIMEPARAMETERCONFIGURATION

TP8-96VIDEO-Installermanual IntroductiontotheTP8-96VIDEOsystem 1-3
ACCESSCONFIGURATION
zCodes:Programming ofthecodes,nameand lengthofthecode, arming/disarming
function and by-pass, association to the programs, attributes
zTransponders: Programmingofthetransponders,name, arming/disarmingfunction
and by-pass, association to the programs, attributes
zWireless keys: Programming of the wireless keys, name, association of the keys to
theprogramsor the functions, attributes
zWireless sirens:Alarmtime, siren delay, flashing time, volume setting,functioning
mode
zWireless consoles: Association of the program status LED to the programs, attributes
zEvents ->Operations:Whenaspecific event happens, the controlpanelexecutes a
specific operation associated to the event, e.g.:
• What kind of event? Arming
•Whicharming?Remotearming
• By whom? User 1
•Whichprogram?Program2
•How? By telephone
zOperations:Creationofanewoperation,operationmodification,operationdeleted
zTelephone directory: Association of specific telephone numbers to the operations
WIRELESSDEVICECONFIGURATION
ADVANCEDPROGRAMMING

IntroductiontotheTP8-96 VIDEO system Installermanual-TP8-96VIDEO
1-4
EVENTLOG
Viewing,printingandsavingasatextfile(TXT)ofthecontrolpaneleventlog.Thestoredeventsareviewedwith
indication of date and time. You can list the event log by date or type.
zN.:Event number. Click to list in chronological order (recordingsequence)
zDate and time: Click to view the events of a determined period of time
zDescription: Event description. Click to list the events by type and view the events of a
specific type
Hardwareconfigurationofthesystem.
Thismenu permits addition or deletion of thehardware modules ofthe system.
zAdd: Click on "add" to add the device selected in the list.
zDelete: Click on "delete" to delete the device selected in the list.
zModules available: List of the modules available for the system.
HARDWARECONFIGURATION
FLOORPLANCONFIGURATION
This menu allows to create and to manage the floor plans associated to the system.
Thismenuisonly enabled if you have thecorrespondingTecnoalarmlicenseand the automatic wiring option is
disabled.
zMenu which permits the selection of the useful elements to create the floor plan.
Forviewingspecificcommandsareavailable.
zSymbols available:For floor plan configuration

TP8-96VIDEO-Installermanual IntroductiontotheTP8-96VIDEOsystem 1-5
RFMONITOR
RF Monitor is a software instrument which permits the graphic presentation of the wireless data transmission.
It also permits measuring of the background noise in the place the control panel is installed.
This function is available only if the control panel is connected.
zRadio rx: Selection of the receiver to control.
zCh.: Selection of the frequency channel to control.
Itpermits viewing ofa virtual consoleto communicate withthe control panel.
You can view the console only if the control panel is connected.
Thismenu allowstobackupandrestorethewirelessdeviceconfiguration.
This function is available only if the control panel is connected.
zReceive (backup): Reception and storage in the PC of the data relating to the
wirelessdevicesfromthecontrolpanel.
Backup(saveacopy)
zSend (restore):Transmission of the data relating to the wireless devices which
havebeen savedbeforeinthePC tothecontrolpanel.
Restore(recoverthedata)
zLast backup: Date and time of the last backup
VIRTUALCONSOLE
BACKUP-RESTOREOFTHEWIRELESSCONFIGURATION

IntroductiontotheTP8-96 VIDEO system Installermanual-TP8-96VIDEO
1-6
OPENINGMESSAGE
Thismenu allows to sendthe opening message programmedin the telephone menuto the control panel.
This function is available only if the control panel is connected.
zSend:Transmission (and storage)of the opening message to the control panel.
zVerify:Reproduction(listening)oftherecordedopeningmessage.
Thismenu allows to upgrade the vocabulary of thesystem and the firmware only for those deviceswhich permit this.
This function is available only if the control panel is connected.
zControlpanel:Allowsto view and upgradethefirmwareversionofthecontrol panel.
zVocabulaire:Allowstoviewandupgradethe vocabulary.
zModule:Allowstoviewandupgrade thefirmwareversionoftheconnectedinput
expansions.
Permits the analysis of the RS485 serial bus communication.
This function is available only if the control panel is connected.
zDip:Logicaladdressof the device
zTOT:Totalnumberoftransmissions
zERROR:Numberofcommunicationerrors
Thismenu allowstocheckthecoherence betweentheprogrammeddevices andthehardwareactuallyinstalled. The
software automatically scans all the installed devices, it checks the coherence with programming and it signals any
possibleincoherence.
This function is available only if the control panel is connected.
FIRMWAREANDVOCABULARYUPDATE
RS485SERIALBUSANALYSIS
HARDWARECOHERENCECONTROL

TP8-96VIDEO-Installermanual IntroductiontotheTP8-96VIDEOsystem 1-7
1.1 TP8-96 VIDEO CONTROL PANEL
8zoneinputs, expandible via RS485bus until 96 (maximum64wireless zones), 6 programmable
outputs, 1 RS485 serial bus port (communication speed 38,4000 Baud), 1 Siren Bus port, GSM
module, 8 ports LAN Ethernet switch, 6.2A power supply
1.1.1 INPUT EXPANSIONS - MAX. 15
zSPEED ALM8 PLUS: Input expansions with power supply, 4 Sensor Bus inputs for 8 RSC
devices, 4 programmable outputs, 1 Siren Bus output for 8 sirens, 1.8A power supply
zSPEED 8 PLUS: Input expansions, 2 Sensor Bus inputs for 8 RSC devices, 2 programmable
outputs
zSPEED 4 PLUS: Input expansions, 1 Sensor Bus input for 4 RSC devices, 4 zone inputs,
1programmableoutput
zSPEED ALM8: Input expansions, 8 zone inputs, 4 programmable outputs, 1.8A power supply
zSPEED 8: Input expansions, 8 zone inputs, 2 programmable output
zSPEED 8 STD: Input expansions, 8 zone inputs
zSPEED 4: Input expansions, 4 zone inputs, 1 programmable output
1.1.2 CONSOLE- MAX.15
zLCD300/S
Console: LCD display with 2 lines of 16 characters, 32 signaling LED, 16 keys, integrated
speaker for voice synthesis
1.2 HARDWARE CONFIGURATION- AVAILABLE MODULES

IntroductiontotheTP8-96 VIDEO system Installermanual-TP8-96VIDEO
1-8
1.1.3 WIRELESSEXTENSION - MAX. 2
zRX300/433868:Dualfrequencywirelessreceiver(433MHz/868MHz),managementofthe
LCD300 WL wireless consoles and the SAEL 2000 WL wireless sirens
zRTX200/433868:Dualfrequencywirelessreceiver-transmitter(433MHz/868MHz),bidirectional
management of the LCD300 WL wireless consoles and the SAEL 2000 WL wireless sirens
zLCD300 WL: Wireless console, LCD display with 2 lines of 16 characters, 16 keys, 1 NC alarm
input
zSAEL2000 WL: Bidirectional dual frequency wireless siren
zTX240-3:Wirelesskey,3programmablefunctionkeys
1.1.4 CONTROLUNITS- MAX. 15
zTP SDN: Electronic keypad, 12 keys, 18 signaling LED, management of maximum 4 programs
zTPSK6N:Transponderreaderwithminikeypad,10signalingLED,managementofmaximum
6programs
zTPSKN:Interfaceforthemanagementoftransponderreaders.Eachtransponderreader
managesmaximum3programs
1.1.5 GSMCOMMUNICATOR-MAX.1
zTECNOCELLPRO-PL: external GSM communicator; transmission via GSM network,
transmissionof SMS messagesand of voice messages. The device has noaddress.
zSPEED RS485: Serial bus extension; allows to increase the length of the serial bus by 1km.
Thedevicehasnoaddress.
zSTAR RS485: Serial bus extension, permits star-shaped connections, 3 RS485 loops, 6 lines.
Thedevicehasnoaddress.
zSAEL2000PRO BUSL: Self-poweredoutdoor siren withRSC technology. Max.8 sirens can be
connected to the Siren Bus.

TP8-96VIDEO-Installermanual IntroductiontotheTP8-96VIDEOsystem 1-9
1.1.6 OUTPUTEXTENSIONS-MAX.16

IntroductiontotheTP8-96 VIDEO system Installermanual-TP8-96VIDEO
1-10

TP8-96VIDEO-Installermanual IntroductiontotheTP8-96VIDEOsystem 1-11

IntroductiontotheTP8-96 VIDEO system Installermanual-TP8-96VIDEO
1-12
N.B.:Thefree(i.e.undefined)outputsareavailableforadvancedprogramming.

TP8-96VIDEO-InstallerManual Programmingofzonesandprograms 2-1
2. PROGRAMMING OF ZONES AND PROGRAMS
Permits the zone input configuration. Click on the above icon. On the screen is viewed:
Thetablesoftheconfigurationzonepermittoprogramthefollowingparameters:
zListof zones controlled bythe control panel, freelyselectable among themodules connected and programmingof
thezoneparameters
zZone-functionassociation
zZone-program association
zAssociation of the programs to the consoles
zAssociation of the programs to the secondary control units (key points)
zSystem options
zLogicoutputparameters
zBussirenparameters
2.1 ZONE CONFIGURATION
2.1.1 CREATION OF ZONE LIST AND PARAMETERS
The TP8-96 VIDEO can control max. 96 zones. The zones can be associated to the zone inputs of the installed
hardware. The system configuration may provide more inputs than the control panel can control. It is for this raison, that
you have to choose the inputs to be controlled from those provided by the modules and draw up a zone list.
A Logic zone. Display the numerical list of the logic zones
managed by the control panel by clicking on the lateral arrow
and select the wished zone.
B Module. Display the device list with the zone inputs clicking
on the lateral arrow and select the wished device. The list is
composedof: Not associated(none device associated to the
logic zone), Control panel, Wireless exp. (espansion zone
radio),modulesfrom1to15(wiredzoneextension).
C Module input. Display the numerical progressive list of the
physicalzoneavailableonthedeviceprecedentlyselectedand
click on the wished zone input.
AB C

Programmingofzonesandprograms InstallerManual-TP8-96VIDEO
2-2
Once logic/physic zone association has been completed, the following items which caracterise the zones are viewed.
ASSOCIATION-COMPOSITIONOFTHEVOICEMESSAGE
It is possible to associate an individual description to the zone that will replace the zone number and identify the
programineveryprocess.The zone description will be viewedonthedisplayand announced by the speaker ofthe
console.
ACheck Voice message item A to enable it.
BThevoice message can becomposed of max. 4words selectable among thoseincluded in the vocabulary.
4items areviewed,onefor eachword.
Click on the arrow of each item to scroll the vocabulary and select the word.
CAt the end, click on the validation arrow C to memorize and play the message.
The words are automatically copied into the description line. It is possible to program the description manually
writing it directly in the description line.
Remember that the display of the console is able to view descriptions of maximum 16 characters. All further
characters will be cut off.
After the description association, programming of the zone continue according to the technology and type of
the selected detector. Each technology has specific programming parameters.
Repeattheprocedureforeveryzonetobeprogrammed(max.96).
Press:
zOK toconfirm and quit
zAbandon toquit withoutsaving
COPY
Permitstocopy the zone configurationifseveral zones must havethesame configuration.
PASTE
Permits to paste the zone configuration copied. This icon is viewed only after clicking on copy. Select the zone
(association of logic zone to physical input of the module) and click on paste. The paste key shows a number which
corresponds to the number of the copied zone. It is sufficient to modify the desired parameters (e.g. the description).
BC
A
Other manuals for TP8-96
2
Table of contents
Other Tecnoalarm Control Panel manuals
Popular Control Panel manuals by other brands

GFS
GFS Deluxe Operator's manual

Siemens
Siemens SINUMERIK 840D sl operating manual

HEIDENHAIN
HEIDENHAIN ND 1100 - V2.15.0 GUIDE Quick reference guide

GE
GE NetworX NX-6V2 installation instructions

Bentel Security
Bentel Security KYO 320 installation manual

NSI
NSI LUMA-NET 400CP Installation and operation guide