2. Mounting
1. Parts
3. Set up Mode
1. & 2. Menu Function Display: Displays various Set-Up menu
functions and information.
2. Edit: Use the Battery button to edit.
3. Back: Use the Settings button go back.
4. & 6. Scroll Arrows: Use the Backlight and Water Pump buttons
to scroll.
To exit Set-up mode, repeatedly press the Back button.
1. AC Connected
2. Battery Off
3. Battery Low
4. Battery Button
5. Settings Button
6. Backlight Button
7. Water Pump Button
8. Input Amps
9. Water Pump Status Indicator
10. Volts
11. Amps
12. Tank Level Indicators
13. Time Remaining
14. Battery Capacity Bar Graph
To mount the JControl:
1. Drill holes in the wall for the connectors.
2. Use flat head screws with a maximum diameter of 4.0mm to
mount the JControl to the wall.
3. Connect the JControl to the wall using the provided
connectors.
4. Attach the provided fascia cover to the JControl.
DOC PART 039106
REV 1.0
JControl Install Guide
The 12V digital battery monitor JControl is a display and control unit that connects to a J35 and displays a range of battery
and water tank information. It acts as a fuel gauge by monitoring the current going in and out of the battery. It also displays
information such as battery volts, solar and AUX input current, charge and discharge status, remaining battery capacity and
water tank levels. JControl can be mounted on any internal wall of your caravan.
Set-up mode allows you to configure the JControl.
To enter Set-up mode, hold down the Settings Button until SET UP is
seen on the Amps and Volts display.
MANUAL DATASHEET PRODUCT PAGE
6. Configuring Water Tanks
4. Configuring Battery Capacity
7. Configuring the Clock
TEAM
BMPRO
.COM
To configure the battery capacity:
1. Enter Set-Up mode.
2. Navigate to the batCaP menu function.
3. Press Edit.
4. Use the Scroll Arrow buttons to set the correct battery capacity.
To enable water tank monitoring:
1. Enter Set-Up mode.
2. Navigate to the tAnKS menu function.
3. Press Edit.
4. Use the Scroll Arrow buttons to select the desired tank.
5. Press Edit.
6. Use the Scroll Arrow buttons to enable or disable the selected tank.
To configure the water tank type:
1. Enter Set-Up mode.
2. Navigate to the tAnKS menu function.
3. Press Edit.
4. Use the Scroll Arrow buttons to select the desired tank.
5. Press Edit.
6. Use the scroll arrows to change to tYP.
7. Press Edit.
8. Use the Scroll Arrow buttons to set the tank to CLn or dtY.
To configure the clock for 12-hour time:
1. Enter Set-Up mode.
2. Navigate to the CLOCK menu function.
3. Press Edit.
4. Press Edit again.
5. Use the scroll arrows to set the hour.
6. Press Edit.
7. Use the scroll arrows to set the minute.
To configure the clock for 24-hour time:
1. Enter Set-Up mode.
2. Navigate to the CLOCK menu function.
3. Press Edit.
4. Use the scroll arrows to change to 24hrS.
5. Press Edit.
6. Use the scroll arrows to set the hour.
7. Press Edit.
8. Use the scroll arrows to set the minute.
DOC PART 039106
REV 1.0

Other manuals for JControl

1

Other BM PRO Measuring Instrument manuals

BM PRO BATTERYCHECK Series User manual

BM PRO

BM PRO BATTERYCHECK Series User manual

BM PRO Drifter User manual

BM PRO

BM PRO Drifter User manual

BM PRO ProSmart User manual

BM PRO

BM PRO ProSmart User manual

Popular Measuring Instrument manuals by other brands

TOTALINE MultiRef User and service manual

TOTALINE

TOTALINE MultiRef User and service manual

Dickson PW8 Series quick guide

Dickson

Dickson PW8 Series quick guide

Kobold Heinrichs BGN Series Installation and operating instructions

Kobold

Kobold Heinrichs BGN Series Installation and operating instructions

Scarlet Tech WL-410 user guide

Scarlet Tech

Scarlet Tech WL-410 user guide

Ametek Thermox CEM/O2 user manual

Ametek

Ametek Thermox CEM/O2 user manual

YATO YT-73140 manual

YATO

YATO YT-73140 manual

HP ESA-E Series Programmer's guide

HP

HP ESA-E Series Programmer's guide

Vzor MAPK-902 Operation manual

Vzor

Vzor MAPK-902 Operation manual

Simex SRT-94 user manual

Simex

Simex SRT-94 user manual

Avisoft UltraSoundGate Series user guide

Avisoft

Avisoft UltraSoundGate Series user guide

CEM DT-9881 user manual

CEM

CEM DT-9881 user manual

National Instruments PXIe-5668R Getting started guide

National Instruments

National Instruments PXIe-5668R Getting started guide

Ista Ultego III Smart Installation instruction

Ista

Ista Ultego III Smart Installation instruction

Burkert 8077 operating instructions

Burkert

Burkert 8077 operating instructions

FLIR EXTECH INSTRUMENTS PQ3450 user guide

FLIR

FLIR EXTECH INSTRUMENTS PQ3450 user guide

Thermo Scientific Polysonics SX30 user guide

Thermo Scientific

Thermo Scientific Polysonics SX30 user guide

Campbell Wind Monitor Series product manual

Campbell

Campbell Wind Monitor Series product manual

Cannon Densi-H Operator's manual

Cannon

Cannon Densi-H Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.