English | 15
Bosch Power Tools 2 609 141 148 | (24.1.14)
Measure the room height Aas for a length measurement. The
measured value (“cst”) is displayed in the top measured-val-
ue line a. The laser remains switched on.
Afterwards, measure length B1of the first
wall. The surface is automatically calcu-
lated and displayed in the result line c.
The length measurement value is dis-
played in the centre measured-value line
a. The laser remains switched on.
Now, measure length B2of the second
wall. The individually measured value dis-
playedinthe centremeasured-valuelinea
is added to the length B1. The sum of both
lengths (“sum”, displayed in the bottom
measured-value line a) is multiplied with
the stored height A. The total surface val-
ue is displayed in the result line c.
In this manner, you can measure any number of further
lengthsBX, which are automatically addedand multipliedwith
height A.
The condition for a correct area/surface calculation is that the
first measured length (in the example the room height A) is
identical for all partial surfaces.
Grade Measurement (see figure G)
After pressing the grade measurement button 3, the indica-
tion for grade measurement appears on the display . The
backside of the measuring tool is used as the reference plane.
By pressing the grade measurement button 3again, the side
surfaces of the measuring tool are used as reference plane
and the display view is shown turned by 90°.
Press the measuring button 2to lock the measuring value and
accept it in the measured values memory. Pressing the meas-
uring button 2again continues the measurement.
When the indication flashes during the measuring procedure,
then the measuring tool was tilted too much in lateral direc-
tion.
If the “digital vial” function is activated in the basic settings,
the grade value is also displayed in the other measuring func-
tions in line dof display 1.
Timer Function
The timer function is helpful, when, for example, movements
of the measuring tool during measuring are to be prevented.
To activate the timer function, press and hold button 6until
the indicator appears in the display.
The time period from the actuation until the measurement
takes place is displayed in the measured-value linea. The time
period can be adjusted between 1 s and 60 s by pressing the
plus button 11 or the minus button 5.
The measurement takes place automati-
cally after the set time period has
elapsed.
The timer function can also be used for
distance measurements within other
measuring modes (e.g. area/surface
measurement). Adding and subtracting measuring results as
well as continuous measurements are not possible.
List of the last Measuring Values
The measuring tool stores the last 50 measuring values and
their calculations, and displays them in reverse order (last
measured value first).
To recall the stored measurements, press
button 7. The result of the last measure-
ment is indicated on the display, along
with the indicator for the measured-value
list eand the memory location of the dis-
played measurements.
When no further measurements are stored after pressing but-
ton 7again, the measuring tool switches back to the last
measuring function. To exit the measured-value list, press
one of the measuring-mode buttons.
To continuously save the currently displayed length measure-
ment value as a constant, press and hold the measured-value
list button 7until “CST” is indicated on thedisplay. A measured-
value list entry cannot be subsequently saved as a constant.
To use a length measurement value in a measuring mode (e. g.
area/surface measurement), press the measured-value list
button 7, select thedesired entry and confirm by pressing the
result button 6.
Deleting Measured Values
Briefly pressing button 4deletes the last individual measuring
value determined in any measuring function. Briefly pressing
the button repeatedly deletes the individual measuring values
in reverse order.
To delete the currently displayed measured-value list entry,
briefly press button 4. To delete the complete measured-val-
ue list and the constant “CST”, press and hold the measured-
value list button 7and at the same time briefly press button 4.
In wall surface measurement mode, briefly pressing button 4
the first time deletes the last individually measured value;
pressing the button a second time deletes all lengths BX, and
pressing the button a third time deletes the room height A.
Adding Measured Values
To add measured values, firstly carry out any measurement or
select an entry from the measured-value list. Then press the
plus button 11. For confirmation, “+” appears on the display.
Then carry out a second measurement or select another entry
from the measured-value list.
To call up the sum of both measurements,
press the result button 6. The calculation
is indicated in the measured-value lines a,
and the sum in the result line c.
After calculation of the sum, further
measured values or measured-value list
entries can be added to this result when
pressing the plus button 11 prior to each measurement.
Pressing the result button 6ends the addition.
Notes on the addition:
– Mixed length, area and volume values cannot be added to-
gether. For example, when a length and area value are add-
ed, “ERROR” briefly appears on the display after pressing
the result button 6. Afterwards,the measuring toolswitch-
es back to the last active measuring mode.
OBJ_BUCH-2007-002.book Page 15 Friday, January 24, 2014 10:46 AM